EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE

Similar documents
Installation & Maintenance Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION AND MAINTENANCE INSTRUCTIONS. 1700ºF Air-Cooled and Insulated ECO-STEEL Chimney Size 13

EXCELPellet FACTORY BUILT PELLET CHIMNEY INSTALLATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

CHIMNEYS AND VENTS CHAPTER 8

Installation and Maintenance Instructions. Model Saf-T Pipe. Heavy Duty Black Stove Pipe. (Also known as a Connector Pipe)

INSTALLATION INSTRUCTIONS

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

DuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.

Pellet Vent INSTALLATION INSTRUCTIONS

CHAPTER 8 CHIMNEYS AND VENTS

Pellet Vent INSTALLATION INSTRUCTIONS

CHAPTER 8 CHIMNEYS AND VENTS

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

PelletVent Multi-fuel venting system. UL 641.

PelletVent. Factory-Built Chimney Relining. Installation Instructions. PelletVent Pro (PVP)

Venting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

VENT SYSTEM COMPONENTS

BDM Direct Vent systems are for use with direct vent gas fired appliances.

X-593 SOLID FUEL HEATING QUESTIONNAIRE

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

Fire Chief Wood/Coal Burning Furnaces

MODEL CF CEILING SUPPORTED CHIMNEY

The intelligent alternative for flue gas venting systems

CHIMNEY INSTALLATION. Technical Bulletin #1

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

OPERATION MAINTENANCE SAFETY SAFETY NOTICE

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

P P Gas Fireplace. P See Thru

Corn Flame Energy Corn Stove Model 3000

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address

St. Croix Greenfield Installation Manual

Owner's Manual Residential Factory Built Fireplace Operation Maintenance Installation ORACLE2

INSTALLATION AND OPERATING MANUAL

Model IVSI Positive Pressure Venting Systems

tççç= ÜÉ~íáåÖ çéíáçåë

Ventis Direct Vent. Installation Instructions

2012 INTERNATIONAL FUEL GAS CODE VENTS

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

Malm Fireplaces, Inc. 368 Yolanda Avenue, Santa Rosa, CA (707) Fax: (707)

napoleonfireplaces.com WOOD BURNING WOOD BURNING FIREPLACES

PelletVent Pro. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Shasta Vent Inc All-Fuel HT Chimney Installation Instructions

INSTALLATION INSTRUCTIONS FOR WHOLE HOUSE FANS

Operating and Installation Instruction Manual

EXHAUST SYSTEMS COMMERCIAL CHIMNEY LINING SYSTEMS.

VP Pellet Pipe. For pellet burning stoves. FEATURES

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

Before selecting your wood heater, it is very important that you clearly identify what your needs are:

Owner's Manual Residential Factory Built Fireplace. Operation Maintenance Installation FOCUS 250

FIREPLACE INSERT, MODEL VOLCANO PLUS OWNER S MANUAL - INSTALLATION - OPERATION. Save These Instructions for Future Reference.

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS

Section 1 - Safety Information Section 2 - Installation: Wall Mount Hoods Section 3 - Installation: Island Mount Hoods

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Advanced Venting Systems

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

Owner's Manual Residential Factory Built Fireplace Operation Maintenance Installation DELTA FUSION Keep these instructions for future use.

HOMEOWNER'S GUIDE FOR YOUR CONTEMPO FIREPLACE TABLE OF CONTENTS

INFRARED RADIANT HEATERS

SL-VENT (oil and gas vent) For use with oil or gas fired appliances. Listed to ULC-609 and UL-641. Available in 5, 6, 7 and 8 I. D.

Contents. Gas Fireplace Types. Wood Fireplace. Electric & Ethanol Fireplaces. Pellet Fueled Appliances. The Original Flame

FACTORY-BUILT FIREPLACE MODEL OWNER S MANUAL - INSTALLATION - OPERATION

Wood Heater Flue Installation Guide Download

Model X-96 (E.P.A. Phase II Approved)

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.

Chimney Renovation Kit

HYBRID-FYRE FLUSH WOOD INSERTS

Pellet Stove. Flex Pipe. Appliance Connector

CONVENIENCES FEATURES ADVANTAGES APPLICATIONS

LDVPV58 Linear Power Vent System

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

Installation and Maintenance Instructions

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

Chimney Fire Prevention

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

FOR EASY, FAST INSTALLATION AND FOR RESULTS

Woodburning Zero clearance

MODEL VC120 SOLID FUEL FURNACE. For use as an add-on to electric, gas, or oil furnaces or an independent wood furnace when equipped with a blower.

CHAMELEON. Owner's Manual Residential Factory Built Fireplace. The. Operation Maintenance Installation. Keep these instructions for future use.

INSTALLATION INSTRUCTIONS

The Estate & The Esteem Direct Vent Fireplaces

LIMITED LIFETIME WARRANTY

Dual Function SMART VENT. Superior Flood Protection and Natural Air Ventilation SMART VENT - Model:

Before selecting your stove, it is very important that you clearly identify what your needs are:

Installation and service must be provided by a qualified installer, service agency or the gas supplier.

Transcription:

THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY ULTRABlack NEVER EVER BUY ANOTHER STOVE PIPE

Chimney To determine what parts you need for your woodstove installation, try the ICC Chimney Configurator which can be found on our website at www.icc-rsf.com OFFSET EXTERIOR RAIN CAP WITH SPARK SCREEN FLASHING ROOF SUPPORT RAIN CAP FLASHING STORM COLLAR RADIATION SHIELD OFFSET SUPPORT WALL SUPPORT ENCLOSED RADIATION SHIELD RADIATION SHIELD TUBE (CANADA ONLY) SQUARE SUPPORT WALL SUPPORT WALL RADIATION SHIELD FLUE EXTENSION FLUE EXTENSION CATHEDRAL CEILING DELUXE RAIN CAP ROOF BRACE FINISH TRIM DELUXE RAIN CAP FINISH TRIM SINGLE STORY FLASHING FINISH TRIM SQUARE SUPPORT FLASHING ROUND SUPPORT FLUE EXTENSION FINISH TRIM FLUE EXTENSION

Chimney is Certified to Withstand Chimney Fires is tested and listed to the ULC S-629 chimney standard. The ULC standard is generally considered the toughest residential chimney standard in the world. The USA standard requires the chimney to withstand three 10-minute 2100 F chimney fires. The Canadian standard requires the chimney to withstand three 30-minute chimney fires, three times longer than the USA. was the first 1 inch wall chimney to pass the ULC standard. You have less chance of a chimney fire with s unique thermoplus insulation has an extremely high insulating value that helps to keep flue gasses hot. Creosote won t condense in a hot flue. is the lightest weight chimney of its kind on the market. This low thermal mass enables it to heat up quickly, reducing creosote formation. And s light weight helps make it the easiest chimney to install. incorporates continuous blanket insulation into a design which eliminates couplings between sections. This means there are no hot spots on the outside, or cool spots on the inside. If you ever have a chimney fire, you ll be glad you have Chimney When a chimney fire erupts, the chimney liner goes from cool to hot in less than a minute. If the chimney design prevents the hot liner from expanding easily (a red hot stainless steel liner is extremely soft and flexible) the liner will buckle permanently. s unique design allows it to undergo repeated chimney fires without damage. That s why we are able to warrant against damage from chminey fires. Innovative Engineering does not have end caps. Eliminating end caps solves two major chimney design problems. End caps make the chimney more rigid at the joints, and can inhibit the ability of the flue to expand and contract. A hot flue needs to be able to expand without resistance to survive a chimney fire without damage. End caps conduct heat from the flue to the outside casing resulting in a cooler flue and a hotter outer casing, exactly the opposite of how a chimney is supposed to work. Premium Materials is made with soft flexible Thermoplus blanket insulation. Thermoplus stays soft even after years of use and multiple chimney fires. This allows the flue to expand easily during a chimney fire. The insulation used by the packed chimney manufacturers is forced in under pressure and can inhibit the ability of the flue to expand during a chimney fire resulting in a destroyed chimney. Blanket insulation cannot settle like packed insulation. s flue is.016, stainless steel. s casing is.016, stainless steel. Superior Construction s continuous seam welded construction eliminates the weakest link in chimney design - the lock seam. Continuous welding is slower and more expensive than conventional methods but it pays off by reducing mechanical stress under chimney fire conditions. Seam welding insures that the chimney is completely gas and water tight too, eliminating the possibility of moisture entering the chimney through the seams.

Improve the performance & appearance of your chimney with specialty flashings & rain caps. DELUXE RAIN CAP The only cap in the industry covered by a lifetime warranty REVOLVING RAIN CAP Perfect for a high wind areas FLEXIBLE BASE FLASHING Customizable to any roof shape METAL ROOF FLASHING The easiest flashing to install on a metal roof ever made Patents US7114301, CAN2460044 ADJUSTABLE PEAK FLASHING Fits any peak from 2/12 to 12/12 RAIN/WIND SHIELD Additional protection for regular or deluxe caps

Technical Information Certification Excel is tested and listed by Warnock Hersey - Intertek Testing Services to two safety standards: UL 103HT - The standard for solid and liquid fuel chimneys installed in the USA. Along with many other tests, the UL 103HT Standard requires the chimney to withstand three 10 minute chimney fires at 2100 F. Listing #5965 ULC S-629 - The standard for solid and liquid fuel chimneys installed in the USA. Along with many other tests, the ULC S-629 Standard requires the chimney to withstand three 30 minute chimney fires at 2100 F. Listing #5965 Applications Excel chimney is suitable for use on appliances that burn: Wood Oil Coal Gas Charcoal It is specifically engineered for wood burning stoves, fireplaces and residential furnaces. Allowable Flue Gas Temperatures Max continuous Brief Forced Firing Tested To 650 C (1200 F) 925 C (1700 F) 1150 C (2100 F) Clearance to Combustible Materials 2 clearance except in areas protected by factory-built supports certified for reduced clearance. Excel round and square supports permit the chimney to be installed with approximately 1 of clearance - in the area shielded by the support. Construction Flue:.016 stainless steel Casing:.016 stainless steel Seam: Interior and exterior seams are continuous seam welded Insulation: Thermoplus continuous blanket Wall thickness: 1 Paint: All black components are painted with Forrest Stove Bright flat black paint Dimensions and Support Capacities Chimney size 5 6 7 8 Rough opening required (INCHES) Round support (ERDS) 10 x 10 10 x 10 11 x 11 12 x 12 Square support (ESS) N/A 10 x 10 11 x 11 12 x 12 Roof support (ESR) 11 x 11 12 x 12 13 x 13 14 x 14 Offset support (EOS) 11 x 11 12 x 12 13 x 13 14 x 14 Radiation shield (ERS & ERSA) 11 x 11 12 x 12 13 x 13 14 x 14 Wall radiation shield (EWRS) 10 x 10 10 x 10 11 x 11 12 x 12 Maximum height per support (FEET) Round support (ERDS) 65 55 50 45 Square support (ESS) N/A 55 50 45 Roof support (ESR) 65 55 50 45 Wall support (EWS) 50 44 37 35 Offset support (EOS) 35 30 27 25 Radiation shields must be used at all floor joist and ceiling areas has been tested and listed to the UL 103HT and ULC S-629 chimney standards by INTERTEK. Listing# 5965

ULTRABlack ULTRABlack DOUBLE WALL STOVE PIPE Hi-tech Performance Double Wall Construction with a 3/8" air space between inner and outer pipes provides superior insulating value to single wall pipe. Better insulating value keeps flue gas temperatures higher. This helps your wood stove perform with an enhanced draft, which provides: less chance for moisture or soot build up within the vent reduced smoking of the stove at start up increased efficiency ULTRABlack not only keeps the flue temperatures higher, it keeps the outer pipe temperatures cooler. This allows ULTRABlack to be installed with only 6" clearance to combustible materials. Single wall stove pipe requires an 18" clearance, which typically means your wood stove sits further away from the wall and takes up valuable space within the room. Most attractive double wall product on the market; no unsightly slots or vents. The outer casing is constructed of satin coat steel. Satin coat is attractive and durable when painted. ULTRABlack is painted with Forrest Stove Bright premium quality, high temperature paint to provide a rich appearance that complements your woodstove.

Never, Ever Buy Another Stove Pipe Only ULTRABlack is covered by a true, no questions asked, 100% full replacement, LIFETIME WARRANTY ULTRABlack Construction Flue:.016" stainless steel Casing:.019" satin coat steel. Satin coat is specifically designed to be painted. Seam: Interior and exterior seams are seam welded. Wall thickness: Approximately 3/8" Paint: Forrest Stove Bright flat black. Fits all brands of type A chimney. Fits almost all makes & models of wood stoves. Fits oval to round. ROUND SUPPORT CLEARANCE BETWEEN CEILING & TOP OFF ELBOW 6" MINIMUM 90 ELBOW (UB90) FIXED OR ADJUSTABLE LENGTH ADJUSTABLE LENGTH (UBAF) 6" ADJUSTABLE LENGTH (UBAF) 6" DAMPER UBD FIXED LENGTH 60" min. STRAIGHT UP INSTALLATION For most straight up installations, the only part required is an adjustable length (UBAF). The UBAF adjusts to allow any overall length from 40" to 68". 90 ELBOW INSTALLATION For most 90 elbow installations, you will only require an elbow (UB90) and an adjustable length (UBAF). If the height from the top of the stove to the top of the elbow is less than 48", you will require a short length plus a slip length (UBSF) for the vertical section of connector instead of the UBAF. DAMPER INSTALLATION (UBD) The damper (UBD) allows you to control the air drawn through your chimney. As such, it controls your stove s combustion. When the handle is in the horizontal position, the damper is closed, creating a restriction in the chimney as far as combustion gases are concerned, and reducing the combustion process inside the stove. (In the close position, the damper is still 20% open so as not to completely block the chimney).

We Build It Better, So We Back It Longer Lifetime Limited Warranty Industrial Chimney Company (ICC) warrants its chimney systems to be free from functional failure due to defects in material or workmanship for as long as the original consumer owns the chimney system. This warranty provides for replacement of any components which fail as a result of normal use on a residential fireplace, wood burning stove, furnace or boiler and includes replacement of any components damaged as a result of a chimney fire. (Note: chimney fires are dangerous and preventable. We strongly encourage you to have your chimney cleaned regularly.) ICC warrants all stainless steel chimney components against perforation as a result of corrosion. This warranty does not cover damage caused to the building by chimney fires or misuse of the product. No claims under this warranty will be honored unless ICC is notified of the potential claim and is given the opportunity to have one of its agents examine the chimney prior to replacement. ICC will only be responsible for repair or replacement of any components found to be defective under this warranty. In no event shall ICC be responsible for any incidental or consequential damage caused by defects in the chimney system. During the first ten years of the warranty, ICC will provide replacement chimney components at no charge. During the balance of the warranty, ICC will provide replacement chimney components at 50% of the current retail price at the time of the warranty claim. ICC will not be responsible for labor of any kind required in the removal or replacement of an system replaced under this warranty. These chimneys are designed to vent residential heating oil, untreated wood, low sulphur coal, and natural or LP gas. They are designed to operate at a continuous temperature of 650 C (1200 F) or less. They are not designed to vent condensing oil or gas appliances. This warranty is void if the chimney is used in an application for which it is not designed. The systems must be installed according to the installation instructions included with every system at the time of purchase. If you do not have a set of installation instructions, they are available free upon request. This warranty is void if the chimney is not installed according to the installation instructions. This warranty may not be extended or modified by our agents or representatives. This warranty is in lieu of all other express warranties or guarantees, of any kind. This warranty is effective as of January 1, 2001. ULTRABlack No Hassle Lifetime Warranty We warranty the ULTRABlack chimney connector against burn out when it is used to vent a wood burning stove or free standing fireplace. If any component of your ULTRABlack stove pipe system ever burns out (develops a perforation as a result of use or corrosion), simply return it to any dealer for a replacement part at no charge. Sorry, we won t pay any labor to remove or replace the ULTRABlack, and we won t pay the freight between you and the dealer. The fine print: You don t need your original bill of sale. You don t need the date of installation. You don t need to show us that the chimney was cleaned regularly (but we do recommend it). You don t need to fill out a warranty card. You don t even need to know our toll-free number. Just bring the ULTRABlack to your local dealer and they will give you a new one. Period. Industrial Chimney Company Inc. Visit our website at www.icc-rsf.com 400 J.F. Kennedy St. Jerome, Quebec, Canada, J7Y 4B7 Tel.: (450) 565-6336 Fax: (450) 565-6519 XLH_2015-04