CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

Similar documents
PREEVA air handling unit

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

RHC GAS FIRED HEATING COILS

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

SolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc.

Gas-fired unit heaters for indoor installation

DF-IDF air handling units

... DF / IDF Gas fired combined heating and ventilation ...

... UDSA - UDSBD Gas fired unit heaters...

RHC & RHCE gas fired heating coils

BENSON.... Variante3 Fired Unit Heaters...

VPC Gas Cabinet Heater Range

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG

CP+ Gas & Oil Cabinet Heater Range

AMBIRAD.... Vision Radiant Tube Heating Systems...

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

VSX models 15% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances.

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

COOLflow 4E PRODUCT RANGE

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Indirect Gas-Fired Make-Up Air

Modular Supply Make-Up Air Unit

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

INDOOR/ OUTDOOR SPLIT SYSTEM HVAC CATALOG

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

PACKAGED HVAC EQUIPMENT CATALOG

Direct Gas-Fired Make-Up Air

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Halton Rex for Vario R6O - Variable air volume chilled beam

Gas-Fired Indoor and Outdoor Duct Furnaces

V-Line. Nozzle-mix line burner

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

DOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR

CITY OPEN - CITY BOX from 25 to 35 kw

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

The ultimate in air handling units: directly and indirectly fired


AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

FEATURES AND BENEFITS

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

The ultimate in air handling units: directly and indirectly fired

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

Direct Gas-Fired Make-Up Air Models DG and DGX

LARGE CAPACITY HEATERS

1 VICTRIX ZEUS Superior kw I features

Halton Rex 600 Basic R6B - Active chilled beam

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

ROOFTOP PACKAGED AIR CONDITIONERS

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Centeral Station Air Handling Unit

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

Energy Recovery with Cooling and Heating Model ERCH

May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

Gas heaters and convectors ROBUR

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

The ultimate in air handling units: directly and indirectly fired

RoofVent Design Handbook

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Exhaust Duct Design Page 1 of (C)

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Products and prices. CLIMATE TECHNOLOGY feels better, works better.

Commercial Evaporative Cooling

RGE 13 A T - 1 A

Küba SG commercial

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

CONTROL OPTIONS SPACE HEATING APPLICATIONS MAKEUP AIR HEATING APPLICATIONS PEH, PXH, RDH, REH, RXH, SDH & SHH. Horizontal Split System- Models PDH,

Ceiling air diffuser INDULTHERM INDULTHERM-e

SPECIFICATIONS - NIKE

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Fan Coil Unit CULTRA

Domestic & Commercial Fans

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Application instructions

Transcription:

CI/SfB 56.83 X EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS

EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS Introduction The Reznor EnviroPak is a new generation of gas fired air heaters to provide combined heating and ventilation with optional cooling. The units are available as either indoor or outdoor models with a wide range of heat outputs and cooling capacities. The units are available as non-condensing heaters with thermal efficiencies above % or fully condensing heaters with thermal efficiencies of 102% (ncv). EnviroPak units have been developed utilising the proven engineering expertise gained by Reznor, with over 125 years experience of gas appliance manufacture. The design combines high thermal efficiency, quality components and ease of maintenance for enhanced life expectancy and reduced life cycle costs. The new range provides higher thermal efficiencies and reduced emissions with the addition of optional cooling and improved air filtration. To reduce on site installation time units are supplied to site pre-assembled on a heavy gauge galvanised base and are fully wired complete with all motor starters. Where site access is restricted the units can also be supplied (at additional cost) in sections for on site assembly. Features EnviroPak gas-fired units incorporate patented 4-pass heat exchanger technology for optimum efficiency and enhanced life expectancy SHH and RHH models also incorporate a patented MacroChannel heat exchanger to provide 8-pass heat exchanger design with full load efficiency of 102% Choice of titanium stabilised aluminised steel or stainless steel heat exchangers to suit application Single burner with multi-try ignition provides enhanced reliability Patented self-aligning burner eliminates possible flame impingement and premature heat exchanger failure Quality and Standards CE EN1020 IS 9001 Model Range EnviroPak units are available as indoor models (SDH / SHH) or outdoor weatherproof models (RDH / RHH) suitable for rooftop or low level installation. 7 non-condensing models with heat output ranging from 24-97kW 3 fully condensing models with heat output ranging from 54-99kW Cooling 18-65kW Air volumes 1700-14100 External static pressure up to 400Pa Heat recovery unit SHH Gas fired condensing unit 102% Thermal Efficiency SDH Standard efficiency unit

Air Distribution The units are ideal for ducted installations with a choice of motor size and drives to provide external static pressures up to 400 pascals (dependent on options fitted). An adjustable pulley is fitted to the motor to simplify on site airflow adjustment for final balancing. The units may also be used for free-blowing applications with a choice of optional outlet louvres, induction nozzles and 30 or 60 degree downflow heads. Units may also be supplied with purpose designed air distribution systems. ECA This symbol verifies that the product has been independently assessed and currently qualifies for the ECA scheme, an upfront tax relief enabling businesses that invest in energy-saving equipment to claim 100% first-year capital allowances against their taxable profits. Air-Mixing Air-Mixing distribution ducts provide a viable alternative to traditional metal ductwork distribution for applications where ductwork is exposed. Each duct is individually designed and manufactured to suit distribution, mounting height and application requirements. Computer designed ducts are perforated precisely to suit each application and act as induction nozzles to promote very high volume turnovers, providing evenly diffused air distribution both horizontally and vertically. Rapid installation reduces on site costs Range of colours provides aesthetic appearance without the additional cost and ongoing maintenance of on site painting Induction effect provides automatic high level air recirculation and eliminates requirement for additional installation of high level fans Evenly diffused air distribution without draughts ow noise Air Distribution Nozzles For large open areas, air induction nozzles provide even air distribution with automatic high level air recirculation. The nozzles are capable of an air throw of up to 60 metres and the high volume turnover induced eliminates the requirement to install additional high level recirculation fans. Nozzles may be grouped on a distribution plenum to provide controlled terminal velocities on both heating and cooling modes or may be supplied complete with mounting plates for fitting to conventional grille shoes. The rubber nozzles provide excellent acoustic reduction at high outlet velocities and may be adjusted through 60 for controlled air direction. Service Access All motor and burner controls are accessed from a single side. Units can be supplied with the controls access on either the right hand or left hand side, this must be clearly specified at order stage and cannot be changed once the units are manufactured. eft Hand Access Ri h h d Ri h h Right Hand Access d

EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS SDH and SHH Indoor Models Chassis Units are supplied factory assembled on a galvanised frame. Standard units are supplied with powder coat finish RA 9010 (white). ther colours available on request. All service access panels are hinged for ease of access with lift off hinges allowing for access where space is restricted. ptional insulation provides thermal and acoustic insulation. Heat exchanger Patented 4-pass vertical heat exchanger provides high thermal efficiency combined with extended life expectancy. Integral condensate drain between third and fourth pass removes the risk of condensate build up when units operate on fresh air during winter periods. SHH model consists of the above heat exchanger with aluminium MacroChannel section to provide increased thermal efficiency up to 102%. Burner Single burner with multi-try ignition provides enhanced reliability. Patented self-aligning burner eliminates risk of flame impingement and premature heat exchanger failure. Burners may be specified for on/off, high/low or fully modulating control. A microprocessor burner control provides full safety monitoring. Flue Fan assisted flue with venter fan mounted on top of stainless steel collection chamber. For SHH units an epoxy coated aluminium venter fan is fitted. Balanced flue operation eliminates the requirement for additional plant room ventilation. The balanced flue terminal provides both the flue outlet and combustion air inlet and requires only a single building penetration. ptional balanced flue wall outlet or roof outlet terminals are available. Units are also CE certified for fan assisted flue installations where combustion air is drawn from within the heated space or ventilated plant room. Air handling Belt driven DIDW forward curved fans, with a choice of single or three phase motors. Three phase motor 0.75kW and above are energy efficient class IE2. Fans are selected for low noise operation with external static pressure up to 400 pascals. Adjustable drive pulley allows for on-site system balancing. Mixing box Aluminium aerofoil section dampers complete with edge seals for precise control of fresh air and recirculation air. A comprehensive range of damper actuators may be factory fitted and wired to provide occupancy ventilation or fresh air free cooling. A wide range of filters are available with optional manometer or pressure switch to provide dirty filter indication. ptional Cooling ptional DX or chilled water cooling coils may be added where comfort cooling is required. Controls Units are supplied fully wired complete with all motor starters, an optional external isolator may also be fitted. Unit electrical protection IP20. A wide variety of control options is available to provide fully integrated control.

RDH and RHH utdoor Models The RDH and RHH outdoor units are supplied fully weatherproof complete with galvanised base frame, integral gutters and integrated flue terminal. ptional roof curbs also available. Cabinet Zinc plated pre-painted panels are insulated to provide thermal and acoustic insulation. All service access panels are hinged for ease of access with lift off hinges allowing for access where space is restricted. Heat exchanger Patented 4-pass vertical heat exchanger provides high thermal efficiency combined with extended life expectancy. Integral condensate drain between third and fourth pass removes the risk of condensate build up when units operate on fresh air during winter periods. RHH model consists of the above heat exchanger with aluminium MacroChannel section to provide increased thermal efficiency up to 102%. Burner Single burner with multi-try ignition provides enhanced reliability. Patented self-aligning burner eliminates risk of flame impingement and premature heat exchanger failure. Burners may be specified for on/off, high/low or fully modulating control. A microprocessor burner control provides full safety monitoring. Flue Fan assisted flue with venter fan mounted on top of stainless steel collection chamber. For RHH units an epoxy coated aluminium venter fan is fitted. Air handling Belt driven DIDW forward curved fans, with a choice of single or three phase motors. Three phase motor 0.75kW and above are energy efficient class IE2. Fans are selected for low noise operation with external static pressure up to 400 pascals. Adjustable drive pulley allows for on-site system balancing. Mixing box Aluminium aerofoil section dampers complete with edge seals for precise control of fresh air and recirculation air. A comprehensive range of damper actuators may be factory fitted and wired to provide occupancy ventilation or fresh air free cooling. A wide range of filters are available with optional manometer or pressure switch to provide dirty filter indication. ptional Cooling ptional DX or chilled water cooling coils may be added where comfort cooling is required. Controls Units are supplied fully wired complete with all motor starters, an optional external isolator may also be fitted. Unit electrical protection IPX4D. A wide variety of control options is available to provide fully integrated control. *Air intake hood illustrated is supplied as an optional item

EnviroPak Heat Recovery GAS FIRED HEATING, VENTIATIN AND CING UNITS Introduction Heat recovery module is an option on the EnviroPak units. The pre-insulated module contains a cross flow heat exchanger with an incorporated summer bypass and a return air fan. Filters of different qualities are available to filter the fresh air and the returned air. peration The fresh air, taken in by the EnviroPak unit is preheated by return / exhaust air passing through the cross flow heat exchanger. In this way, less energy is needed to heat the ventilation air. The efficiency of the heat exchanger runs up from 52 to 68% according the application. Model Range The units contain a module for heat recovery by means of a cross flow heat exchanger. EnviroPak Heat Recovery is available in 4 different versions. RDH - HRS: outdoor installation with standard efficiency. - HRH: outdoor installation with high efficiency. 9 o C 0 o C 11 o C SDH - HRS: indoor installation with standard efficiency. - HRH: indoor installation with high efficiency. 30 o C 20 o C

Ri h h d Ri h h d Ri h h d Flue Installation For internal applications the balanced flue terminal provides both the combustion air inlet and flue outlet from a single building penetration. The terminals are ordered separately from the heaters to suit either a wall outlet or roof outlet. Additional flue and combustion air pipes may be added, up to a maximum of nine metres of flue pipe, plus nine metres* of combustion air pipe. (This reduces by 1.5 metres for every 90 bend fitted). A differential pressure switch shuts down the unit in the event of inadequate combustion air, blocked flue or flue fan failure. To comply with CE approvals, balanced flue appliances must be used with the manufacturer s balanced flue system. Balanced flue roof outlet (type C32) Balanced flue wall outlet (type C12) eliminates expensive roof opening and flashing The units are also certified for fan assisted flue installations, where the combustion air is to be drawn from inside the building; an alternative wall or roof terminal is required for this application. Maximum flue length 14 metres (12 metres on model 100). *up to 7.5 metres for model 100 Combustion air through wall, flue outlet through the roof (C52) Heater positions and flue arrangements are indicative. For heater and flue clearances please refer to the manufacturer's guidelines. Separate combustion air and flue pipes (type C12) for applications where wall thickness exceeds maximum length shown in flue dimension table A A D C E D G B G F B FUE DIMENSINS (mm) Model Vertical concentric flue terminal Horizontal concentric flue terminal Ø100mm Ø130mm Ø100mm Ø130mm A 1361 1973 775 940 B 140 225 140 225 C n/a n/a 100 130 D 150 200 150 200 E n/a n/a 170 180 F (maximum wall thickness) n/a n/a 370 370 G 253 355 225 355

EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS 46 SDH Indoor Model A G C E F M M H B N I J K 100 D Front View Side View Rear View 1. Combustion air inlet 2. Flue outlet 3. Electrical connections 4. Gas connections 5. Access door P Q Plan View DIMENSINS Model SDH25 SDH30 SDH35 SDH43 SDH55 SDH73 SDH100 A mm 840 1094 1094 840 840 1268 1468 B mm 753 753 753 988 988 988 988 C mm 1860 1860 1860 2300 2300 2300 2300 D mm 2060 2060 2060 2500 2500 2500 2500 E mm 574 574 574 842 757 765 765 F mm 140 140 140 140 225 225 225 G mm 190 190 190 190 190 240 240 H mm 451 451 451 686 686 686 686 I mm 28 28 28 28 28 234 235 J mm 583 837 837 583 583 710 901 K mm 229 229 229 229 229 324 332 mm 600 700 700 600 600 1000 1200 M mm 120 197 197 120 120 134 134 N mm 212 212 212 229 229 229 229 mm 300 300 300 500 500 500 500 P mm 806 1060 1060 806 806 1234 1434 Q mm 1990 1990 1990 2430 2430 2430 2430 Flue and combustion collars (1,2) mm 100 100 100 100 130 130 130 Typical configuration shown above for SDH complete with mixing box. For alternative configurations please consult Reznor. Unit shown with left hand access, units can also be supplied right hand access. eft hand access or right hand access must be specified on ordering as this cannot be changed once the units are manufactured. All dimensions have a tolerance of +/- 3mm

RDH utoor Model A C R M M H B N J 100 D Front View Side View Rear View Q 1. Combustion air inlet 2. Flue outlet 3. Electrical connections 4. Gas connections 5. Access door P Plan View DIMENSINS Model RDH25 RDH30 RDH35 RDH43 RDH55 RDH73 RDH100 A mm 840 1094 1094 840 840 1268 1468 B mm 753 753 753 988 988 988 988 C mm 1860 1860 1860 2300 2300 2300 2300 D mm 2060 2060 2060 2500 2500 2500 2500 H mm 451 451 451 686 686 686 686 I mm 28 28 28 28 28 234 235 J mm 583 837 837 583 583 710 901 K mm 229 229 229 229 229 324 332 mm 600 700 700 600 600 1000 1000 M mm 120 197 197 120 1200 134 134 N mm 212 212 212 229 229 229 229 mm 300 300 300 500 500 500 500 P mm 806 1060 1060 806 806 1234 1434 Q mm 1990 1990 1990 2430 2430 2430 2430 R mm 649 649 649 816 816 816 816 Typical configuration shown for RDH complete with inlet weatherhood. For alternative configurations please consult Reznor. Unit shown with left hand access, units can also be supplied right hand access. eft hand access or right hand access must be specified on ordering as this cannot be changed once the units are manufactured. All dimensions have a tolerance of +/- 3mm

EnviroPak Series GAS FIRED HEATING, VENTIATIN AND CING UNITS 46 SHH Indoor Model A (Condensing heaters with optional filters and mixing dampers) C M M N H B G I J K 100 E 6 6 Front View 6 D Rear View Side View Q 1. Combustion air inlet 2. Flue outlet 3. Electrical connections 4. Gas connections 5. Access door 6. Condense Drain P Plan View DIMENSINS Model SHH55 SHH83 SHH102 A 840 1468 1468 B 988 988 988 C 2737 2737 2737 D 2937 2937 2937 E 940 940 940 G 458 458 458 H 686 686 686 I 28 235 235 J 583 901 901 K 229 332 332 600 1200 1200 M 120 134 134 N 231 231 231 500 500 500 P 806 1434 1434 Q 2867 2867 2867 Flue and combustion collars (1,2) 100 130 130 Typical configuration shown above for SHH complete with mixing box. For alternative configurations please consult Reznor. Unit shown with left hand access, units can also be supplied right hand access. eft hand access or right hand access must be specified on ordering as this cannot be changed once the units are manufactured. All dimensions have a tolerance of +/- 3mm

RHH utdoor Model 46 A C R M M N H B I J K 100 6 6 6 D Front View Side View Rear View Q 1. Combustion air inlet 2. Flue outlet 3. Electrical connections 4. Gas connections 5. Access door 6. Condense Drain P Plan View DIMENSINS Model RHH55 RHH83 RHH102 A mm 840 1468 1468 B mm 988 988 988 C mm 2737 2737 2737 D mm 2937 2937 2937 H mm 686 686 686 I mm 28 235 235 J mm 583 901 901 K mm 229 332 332 mm 600 1200 1200 M mm 120 134 134 N mm 231 231 231 mm 500 500 500 P mm 806 1434 1434 Q mm 2867 2867 2867 R mm 816 816 816 Typical configuration shown for RHH complete with mixing box plus inlet weatherhood. For alternative configurations please consult Reznor. Unit shown with left hand access, units can also be supplied right hand access. eft hand access or right hand access must be specified on ordering as this cannot be changed once the units are manufactured. All dimensions have a tolerance of +/- 3mm

SDH & RDH TECHNICA DATA Model SDH25 RDH25 SDH30 RDH30 SDH35 RDH35 SDH43 RDH43 SDH55 RDH55 SDH73 RDH73 SDH100 RDH100 Nominal heat output Minimum thermal efficiency (H 1 ) kw kw 24 29 35 42 55 73 97 Gas Consumption 1 Natural gas G20 Propane G31 Gas connection 2 kg/h Rc 2.77 2.04 3.35 2.47 4.02 2.96 ¾ 4.85 4.00 6.30 6.64 8.39 6.18 11.19 8.24 Airflow Minimum @ 15 o C Maximum @ 15 o C Maximum @nom. cooling capacity 1700 3500 3500 2100 4200 4200 2500 5100 5100 3000 6100 5750 3900 8000 5750 5300 10600 9800 7000 14100 11800 utput cooling capacity Maximum with DX Coil Maximum with cooling water coil kw kw 17.6 20.9 20.9 24.3 29.0 27.6 36.0 31.2 36.0 31.2 50.7 52.5 65.4 63.7 Motor power Minimum Maximum m m 0.25 1.10 0.25 1.50 0.25 2.20 0.25 3.00 0.37 4.00 0.55 5.50 0.56 5.50 Maximum external static pressure Pa 400 Electrical supply 0.25-0.75 kw : 230/240V 1N - 50Hz 0.55-5.5 kw : 380/400V 3N - 50Hz Net weight kg 212 244 246 287 289 360 430 1 Natural gas G20 Calorific value 10.48 kw/m3 GCV, inlet gas pressure maximum 50 mbar, minimum 17.5 mbar. Propane G31 Calorific value 14.0kW/kg GCV, inlet gas pressure maximum 50 mbar, minimum 37 mbar. 2 Not supply line size. SHH & RHH TECHNICA DATA Model SHH55 RHH55 SHH83 RHH83 SHH102 RHH102 Nominal heat output kw 54 80 99 Gas Consumption 1 Natural gas G20 Propane G31 Gas connection 2 Airflow Minimum @ 15 o C Maximum @ 15 o C Motor power Minimum Maximum kg/h Rc m m 5.59 4.12 5500 8500 0.37 4.00 8.36 6.16 8500 10000 0.55 5.50 Maximum external static pressure Pa 400 10.26 7.57 10000 14000 Electrical supply 0.25-0.75 kw : 230/240V 1N - 50Hz 0.55-5.5 kw : 380/400V 3N - 50Hz Net weight kg 280 445 457 0.56 5.50 1 Natural gas G20 Calorific value 10.48 kw/m3 GCV, inlet gas pressure maximum 50 mbar, minimum 17.5 mbar. Propane G31 Calorific value 14.0kW/kg GCV, inlet gas pressure maximum 50 mbar, minimum 37 mbar. 2 Not supply line size. Document reference number: GB/REZ/010/0213 Reznor UK imited Park Farm Road Folkestone Kent CT19 5DR United Kingdom Telephone: Facsimile: Email: Website: 01303 2541 01303 850002 reznorsales@nordyne.com www.reznor.co.uk Because of continuous product innovation, Reznor reserves the right to change product specification without due notice.