ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower

Similar documents
MERIT SERIES Downflow

MERIT SERIES Downflow

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

ELITE SERIES Downflow - High Efficiency Blower Motor

MERIT SERIES Downflow

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

MERIT SERIES Upflow / Horizontal

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

8+* Bulletin No November 1997

13 GEP A L P - 1 A

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

RGE 13 A T - 1 A

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

ML 1 93 UH 070 x P 36 B

ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B

AFUE 95% Heating Input 50,000 to 200,000 Btuh

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

ML 1 80 UH 070 X E 36 B

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

CB X 32 mv

MERIT SERIES Up Flow / Horizontal

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

GSR21Q PULSE21 SERIES

MERIT SERIES Upflow / Horizontal

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

ELITE SERIES Upflow / Horizontal - Two-Stage Heat

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

MERIT SERIES Upflow / Horizontal

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

MERIT SERIES Upflow / Horizontal

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications

RG7D 1-Stage Heat Series

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

G34M Bulletin #69/ August 2003

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

EL195UH WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. EL195UH SERIES UNITS

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling to 5 Tons GAS FURNACES ML180UHE

FG7T (C and L Series)

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

ML180UHT (ce) MERIT SERIES Upflow / Horizontal 50HZ. Net Input to 34.8 kw Nominal Add-on Cooling to 17.

TECHNICAL SPECIFICATIONS

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

GHR32Q/V SERIES UNITS

Heavy Duty Transformer. Low Voltage Circuit Breaker. Visit us at For the latest technical information,

CONTROLS WI-FI THERMOSTAT. icomfort Wi-Fi Flex Thermostat PRODUCT SPECIFICATIONS

Wt. Lbs Model Number (BTUH) Hz

TECHNICAL SPECIFICATIONS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

G41UF WARNING. Service Literature G41UF SERIES UNITS. Table of Contents

G32V. Service Literature G32V SERIES UNITS

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

TECHNICAL SPECIFICATIONS

Cooling Capacity CFM range

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

Cooling Capacity CFM in. w.c. (125 Pa)

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Cooling Capacity CFM in. w.c. (125 Pa)

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

G6RC Series TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TSTAT0201CW Recommended (sold separately)

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

TECHNICAL SPECIFICATIONS

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

TSTAT0101SC Recommended (order separately)

ELITE Series Variable Capacity

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Transcription:

PRODUCT SPECIFICATIONS GAS FURNACES EL96DFV ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower Bulletin No. 060 March 09 Supersedes September 08 MODEL NUMBER IDENTIFICATION EL 96 DF 070 X V 48 B AFUE - 96% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling - to 5 Tons Unit Type EL = Elite Series Stages = Two-Stage AFUE 96 = 96% Configuration DF = Downflow Nominal Gas Heat Input 045 = 44,000 Btuh 070 = 66,000 Btuh 090 = 88,000 Btuh 0 = 0,000 Btuh Cabinet Width B = 7-/ in. C = in. Nominal Add-On Cooling Capacity 6 = tons 48 = 4 tons 60 = 5 tons Blower V = Variable Speed Blower Motor Low NO x X = Units meet California Nitrogen Oxides Standard (40 ng/j) Downflow indoor coils with the same letter designation will physically match the furnace supply air opening.

FEATURES CONTENTS Blower Data... 0 J I Dimensions... 4 Features... Gas Heat Accessories... H Installation Clearances... 9 Model Number Identification... G Optional Accessories - Order Separately... 0 Optional Accessory Dimensions... 5 Specifications... 9 Duralok Plus Aluminized Steel Heat Exchanger Limited Lifetime warranty in residential applications (twenty year transferable), ten years in non-residential applications. All other covered components - Limited Five Year warranty in residential applications, one year in nonresidential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details. APPROVALS Units are Certified by AHRI. Units are Certified by CSA International. Units tested and rated according to US DOE test procedures and FTC labeling regulations. Blower data from unit tests conducted in Lennox Laboratory air test chamber. Approved by the California Energy Commission and meets California Nitrogen Oxides Standard (NOx) limits of 40 ng/j. Energy Star certified units are designed to use less energy, help save money on utility bills, and help protect the environment. ISO 900 Registered Manufacturing Quality System. California Only If installed in South Coast Air Quality Management District (SCAQMD) only: This furnace does not meet the SCAQMD Rule NOx emission limit (4 ng/j), and thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.cleanairfurnacerebate.com. If installed in San Joaquin Valley Air Pollution Control District (SJVAPCD) only: This furnace does not meet the SJVAPCD Rule 4905 NOx emission limit (4 ng/j), and thus is subject to a mitigation fee of up to $450. EL96DFV / Page F B E K D APPLICATIONS Input capacities of 44,000, 66,000, 88,000 and 0,000 Btuh. Energy efficiency (AFUE) of 96%. Compact cabinet for downflow applications without any internal modifications to the unit. Lennox add-on indoor coils, high-efficiency air cleaners and humidifiers can easily be added to furnace. Shipped factory assembled with controls installed and wired. Each unit factory test operated to ensure proper operation. NOTE - FURNACES CANNOT BE TWINNED! Zoning Applications The EL96DFV furnace can be used with the Lennox iharmony Zoning System with the icomfort Communicating Thermostat. The iharmony Zoning System provides direct feedback to the furnace, controlling both airflow and heat output to match the comfort requirements for up to four zones. HEATING SYSTEM B Lennox Duralok Plus Heat Exchanger Assembly I H LO ON WARRANTY C OFF Vent Lengths - Uninsulated Exhaust Pipe In Unconditioned Space... C C I I HI Lennox developed heat exchanger assembly consists of primary heat exchanger and secondary condenser coil assembly. Main multi-pass crimped seam design clamshell type heat exchanger.

C D E FEATURES HEATING SYSTEM (continued) Constructed of heavy-gauge, aluminized steel. Designed for normal expansion and contraction with maximum efficiency and minimum resistance to air flow. Secondary heat exchanger condenser coil constructed of aluminum fins fitted to stainless steel tubes. Coil is factory tested for leaks. Condensate drain header box assembly located on front of coil. Compact size of complete heat exchanger assembly permits low overall design of furnace cabinet. Heat exchanger assembly has been laboratory life cycle tested in excess of industry standards. Lennox Designed Header Box Header box on end of condenser coil collects flue condensate for disposal through condensate drains. The drains are located on each side of the cabinet for easy field installation of condensate drain trap. Only one drain is used, the other drain is sealed. Condensate drain trap is included with unit for field installation. Lennox Designed Flue Condensate Trap Assembly Condensate trap assembly is mounted outside the conditioned air stream. Assembly can be mounted on either side of cabinet. See Installation Instructions. 90 street elbow furnished for ease of drain trap installation. Drain connection can be made with field provided PVC pipe, PVC coupling, or vinyl tubing with hose clamp. Drain cap on trap allows easy cleaning and winterizing. Inshot Burners Aluminized steel inshot burners provide efficient, trouble-free operation. Burner venturi mixes air and gas in correct proportion for proper combustion. Burner assembly is removable from the unit as a single component for ease of service. SureLight Hot Surface Ignitor Tough, reliable, long-life, trouble-free performance. Silicon nitride ignitor. Cemented to steatite block for protection against current leakage. Ignition leads are constructed of nickel plated copper and are enclosed in high temperature Teflon insulation for dependable operation. Two-Stage Gas Control Valve 4 volt redundant combination two-stage gas control valve combines manual shut off switch (On-Off), automatic electric valve (dual) and gas pressure regulation into a compact combination control. F Two-Speed Combustion Air Inducer Permanent split capacitor (PSC), heavy duty blower prepurges heat exchanger and safely vents flue products. Dual pressure switches (low fire/high fire) prove blower operation before allowing gas valve to open. Operates only during heating cycle. Direct access allows inducer assembly to be rotated 90 clockwise or counterclockwise to facilitate easy vent attachment in horizontal applications. Flame Rollout Switches () Manual reset switches are factory installed on burner box. Switch provides protection from abnormal operating conditions. Limit Control Automatic reset, primary limit is accurately located on vestibule panel on all units. Optional Accessories High Altitude Orifice Kits Required on all units for proper unit operation at altitudes from 750 to 0,000 ft. Kits are available for natural gas and LPG/propane. High Altitude Pressure Switch Kit Required for proper unit operation on installations above 4500 ft. Natural Gas to LPG/Propane Conversion Kit Required for field changeover from natural gas to LPG/ Propane. LPG/Propane to Natural Gas Conversion Kit Required for field changeover from LPG/Propane to natural gas. Muffler (US Only) Significantly reduces outdoor operating sound levels. Two-inch diameter muffler is optional for 045 through 0 input models. NOTE - Two-inch muffler is optional for the 0 input model with a maximum vent pipe length of up to 9 ft. Three-inch diameter muffler is optional for 0 input models. NOTE - Three-inch muffler is optional for the 0 input model with a minimum vent pipe length of 0 ft. Installed vertically in the exhaust piping. See Optional Accessory Dimension Drawing. EL96DFV / Page

FEATURES DIRECT VENT / NON-DIRECT VENT SEALED COMBUSTION SYSTEM Furnace features a sealed combustion system and can be installed in either Direct Vent or Non-Direct applications. In Direct Vent applications, combustion air is supplied from outdoors and flue gases are discharged outdoors. In Non-Direct Vent applications, combustion air is supplied from indoors and flue gases are discharged outdoors. NOTE - Lennox has approved the use of DuraVent PolyPro and Centrotherm InnoFlue manufactured vent pipe and terminations as an alternative to PVC vent pipe. Must be ordered separately. Tested and listed to the ULC S66 standard in Canada. The polypropylene venting system must follow the uninsulated and unconditioned space vent lengths listed in the table on Page. Refer to the Installation Instructions for additional details. Optional Accessories Flue Coupling Assists with exhaust flue piping connection and servicing. Includes flexible one inch rubber coupling and two adjustable bands. Approved for all Lennox 90% furnaces. Termination Kits Facilitates installation of combustion air intake pipe and flue exhaust pipe. Refer to venting table in this bulletin to determine pipe size needed and proper termination kit required. Certain Termination Kits are certified to ULC S66 standard for use in Canada only. See Optional Accessories table and dimension drawings. Termination Kit - Concentric - Direct Vent Applications or inch kit contains concentric termination assembly, reducer bushing and 45 degree elbow. inch kit for -045-070 models contains an outdoor exhaust accelerator. Kit requires single hole penetration of roof or wall for installation. Roof Termination Flashing Kit is available for use with inch Kits. CSA certified. Termination Kit - Flush-Mount Kit contains flush-mount termination, accelerator, mounting template and hardware. Kit may be used with, -/ or in. pipe. G Termination Kits - Wall Assembly Close Couple (US Only) - Direct Vent Applications or inch kit consists of close-couple, side-by-side PVC piping with galvanized steel wall cover plate for sealing and isolating piping penetration of the wall. Piping spacing and length is sized for proper wall installations. CSA certified. Close Couple WTK (Canada Only) - Direct Vent Applications or inch kit contains one insulated faceplate, one insulated exhaust pipe, elbow and fittings. Certified to ULC S66 standard. Wall Ring - Direct Vent or Non-Direct Vent Applications inch kit contains stainless steel outside seal caps, galvanized steel inside seal caps, 4 seal rings for the caps and 8 inch insulation sleeve for sealing and isolating intake and exhaust piping penetration of wall. Maintain a maximum of 6 inches between the inlet and outlet openings in the installation of the pipes. Roof Termination Flashing Kit - Direct Vent or Non-Direct Vent Applications inch kit contains two neoprene rubber roof flashings for vertical venting through a roof. Vent pipe and insulation not furnished. Flashing Kit can also be used with inch Concentric Vent Termination Kits used in vertical venting rooftop applications. Left Side Vent Kit Allows venting out the left side of the cabinet. Kit contains left vent tube and seal plate. CONTROLS SureLight Control (icomfort Communicating) Advanced control communicates information about various operating parameters in the furnace to the optional icomfort Communicating Thermostat to constantly maintain the highest level of comfort and performance available. Auto Configuration - On startup the control automatically sends a description of the unit to the optional icomfort Communicating Thermostat to automatically configure the number of stages and features available. Connections for connecting a conventional heating/ cooling thermostat are also provided on the control. Control also features Innovative AirFlex technology which allows custom blower settings based on the application. EL96DFV / Page 4

FEATURES CONTROLS (continued) Thermostat Control - For optimal performance, the use of a high-quality, digital two-stage thermostat with adjustable settings for first stage/second stage, on/off differentials and adjustable stage timers is recommended. Furnace Input Staging Options Thermostat Type Input Staging Available icomfort Communicating Thermostat Two-Stage (Conventional) Single-Stage (Conventional) Two-Stage (65 and 00%) Safety Controls - Flame sensor utilizes flame rectification for safe and reliable operation. Should flame fail to ignite, control will initiate 4 reattempts at ignition before locking out unit operation for 60 minutes. Watchguard type circuit automatically resets ignition control after one hour of continuous thermostat demand after unit lockout, eliminating nuisance calls for service. Display LED - Seven segment LED displays alphanumeric information related to diagnostics as well as system operation and status. Diagnostic codes are held in non-volatile memory, immune from power interruptions. Holds up to ten diagnostic codes in order of occurrence for recall on demand. Port on blower door allows for easy viewing. DIP Switch Settings Select Thermostat used - Single-Stage or Two-Stage. Two selectable second stage recognition times (7 and minutes) are available on the control when the furnace is used with a single-stage thermostat. When used with a two-stage thermostat, furnace will only initiate second stage operation with a second stage thermostat demand. Heating Speeds - A combination of DIP switch settings allow the following motor speed selection settings within the heating speed selected for fine tuning air volume: Factory default 6%, %, 8% or 4% increase 6%, % or 8% decrease See Blower Performance tables. Cooling Speeds - A combination of DIP switch settings allow the following motor speed selection settings within the cooling speed selected for fine tuning air volume: Factory default 0% increase 0% decrease See Blower Performance tables. Blower Speed Ramping (Cooling Mode) - DIP switch settings allow one of four blower speed profiles during cooling operation. Profile A (factory setting) - Motor runs at 50% for 0 seconds, then at 8% for 7-/ minutes, then at 00% (if needed) until demand is satisfied. Once demand is met, motor runs at 50% for 0 seconds, then ramps down to stop. Profile B - Motor runs at 8% for 7-/ minutes and then at 00% (if needed) until demand is satisfied. Once demand is met,motor ramps down to stop. Profile C - Motor runs at 00% until demand is satisfied. Once demand is met, motor runs at 00% for 60 seconds, then ramps down to stop. Profile D - Motor runs at 00% until demand is satisfied. Once demand is met, motor ramps down to stop. Dehumidification (Active or Humiditrol Option) - A jumper on the control control must be clipped to enable active dehumidification and/or operation with a Humiditrol Whole-Home Dehumidification System. A humidity controlling thermostat or device is also required. During a call for cooling, air volume is automatically reduced, forcing humidity removal by the air conditioner or heat pump system (single stage units or two-stage units running at nd stage). After the humidity has reached the desired set-point the cooling air volume returns to its designed rate. A dehumidification signal from the thermostat reduces the cooling cfm to 70% of the requested cooling cfm. Dual-Fuel Operation - A jumper on the control must be clipped to enable operation with a single or two-stage heat pump. The indoor blower is started without delay when a call for heat is received. Two-Stage Compressor Operation - A jumper on the control must be clipped to enable operation with a two-stage compressor. The cooling blower speeds for first and second stage cooling will be dictated by the applicable DIP switch settings. Lennox System Operations Monitor Connection - Monitors outdoor unit operation (communicating mode). Blower On/Off Time (Heating) - Blower on time is fixed at 0 seconds, blower off time is adjustable from 60, 90, 0 and 80 seconds (factory setting - 90 seconds). Blower On/Off Time (Cooling) - For air-conditioning applications, blower on time is seconds following thermostat demand for cooling. See Blower Speed Ramping (Cooling Mode) profiles for various blower off details. Controls evaporator humidity by controlling blower and compressor speed on two-stage outdoor units when used with the icomfort Communicating Thermostat or the ComfortSense 7500 Thermostat. EL96DFV / Page 5

FEATURES CONTROLS (continued) Continuous Blower Speed - Adjustable continuous blower speed is a percentage of the high cooling speed selection. There are four selectable options (via DIP switch settings) of 8%, 8% (default setting), 70% and 00%. Accessory Terminal - One accessory terminal furnished for additional power supply requirements for 0 volt (less than amp) powered air cleaners. One unpowered pair of contacts are provided for humidifier connections and may be connected to 4V or 0V. Control is factory installed in the unit control box. 4 Volt Transformer Furnished and factory installed in control box. 40VA transformer has circuit breaker wired in series. Field Wiring Make-Up Box Furnished for line voltage wiring. Factory installed internally on left side of furnace. Box may be installed internally or externally on either side of furnace. Optional Accessories icomfort S0 Ultra-Smart Thermostat (part of the icomfort Residential Communicating Control System) The icomfort S0 Thermostat recognizes and connects to all icomfort Communicating products to automatically configure and control the heating/cooling system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for icomfort Communicating products to simplify system setup. Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Also displays service alerts and reminders. Apple HomeKit compatible. Control the S0 thermostat from an iphone, ipad or ipod device and use Siri voice commands. Amazon Alexa-enabled, smart-home-compatible. Works with Amazon Echo, Echo Dot and Tap devices. Dealer Dashboard features online real-time monitoring of installed icomfort Communicating systems. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen. Easy to read 7 in. high definition color display (measured diagonally). Conventional outdoor units (not icomfort Communicating) can easily be added and controlled by the icomfort S0 Thermostat. Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 8-gauge standard thermostat wiring. High Definition Color Display, Mag-Mount, Smart Hub Controller, wallplate (for retrofit installations) furnished for easy installation. See the icomfort S0 Thermostat Product Specifications bulletin in the Controls section for more information. EL96DFV / Page 6

FEATURES CONTROLS (continued) Optional Accessories (continued) icomfort E0 Smart Wi-Fi Thermostat Wi-Fi enabled, electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. Heat/ Cool. Auto-changeover. Controls dehumidification during cooling mode and humidification during heating mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol control, and equipment maintenance reminders. Easy to read 7 in. color touchscreen (measured diagonally). LCD display with backlight shows the current and set temperature, time, inside relative humidity, system status (operating mode and schedules) and outside temperature (optional outdoor sensor required). Smooth Setback Recovery starts system early to achieve setpoint at start of program period. Compressor short-cycle protection (5 minutes). Up to four separate schedules are available plus Schedule IQ. One-Touch Away Mode - A quick and easy way to set the cooling and heating setpoints while away. Smart Away - Uses geo-fencing technology to determine when the homeowner is within a predetermined distance from the home to operate the system when leaving, away and arriving. Apple HomeKit enabled, making it easy to control the E0 thermostat from an iphone, ipad or ipod device. Use Siri voice commands to control the E0 thermostat. Amazon Alexa-enabled, smart-home compatible. It works with Amazon Echo, Echo Dot and Tap devices. Wi-Fi remote monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. High Definition Color Display, Mag-Mount, Smart Hub Controller, wallplate (for retrofit installations) furnished for easy installation. Additional indoor air quality comfort products (PureAir Air Purification System, Healthy Climate Humidifiers, Humiditrol Enhanced Dehumidification Accessory, Healthy Climate Energy/Heat Recovery Ventilators, Healthy Climate Germicidal Lights) can be added to the system for a complete total-comfort system. See the icomfort E0 Smart Wi-Fi Thermostat Product Specifications bulletin in the Controls section for more information. Remote Outdoor Temperature Sensor Used with the icomfort E0 Smart Thermostat. When installed outdoors, sensor allows thermostat to display outdoor temperature. Sensor is auto-detected when connected to thermostat. NOTE - Sensor is required for Enhanced Dehumidification Control (EDA) applications. NOTE - The outdoor sensor is furnished as standard with icomfort Communicating outdoor units, optional for conventional units. Thermostat Thermostat (icomfort Communicating Thermostat or programmable/non-programmable) is not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book for selection. Night Service Kit Contains most commonly used service parts: Furnace control Igniter Flame sensor Gas valve Transformer Service Manual EL96DFV / Page 7

H I J K FEATURES BLOWER Variable Speed Direct Drive Blower Each blower assembly statically and dynamically balanced. Change in blower speed is easily accomplished by simple DIP switch change on furnace control. See Blower Data tables. Blower assembly easily removed for servicing. Variable Speed Blower Motor Variable speed motor maintains specified air volume from 0 though 0.8 in. w.g. (heating) and 0 through.0 in. w.g. (Cooling) static range. Variable speed operation is achieved by the use of an ECM (Electronically Commutated Motor) motor. Motor is controlled by furnace control. Motor is resiliently mounted. When furnaces are used with the iharmony Zoning System and the icomfort Communicating Thermostat, the blower motor operates from predetermined minimum - maximum air volumes to satisfy zone requirements. CABINET Low-profile, narrow width cabinet allows easy installation in downflow applications. Heavy-gauge, cold rolled steel construction. Pre-painted cabinet finish. Flanges provided on supply air opening for ease of plenum connection or alignment with indoor coil. Cabinet is insulated with foil faced insulation on sides and back of heating compartment and mat faced insulation in blower compartment. Sealed blower compartment. Inner blower compartment access panel seals blower compartment from air leakage. Cabinet door can be removed without any tools. Complete service access. Safety interlock switch automatically shuts off power to unit when blower compartment access door is removed. Gas piping and electrical inlets are provided in both sides of cabinet. Coil Match-Up All Lennox downflow indoor coils will physically match the furnace supply air opening with the same letter designation (A, B, C, D) as in the furnace model number. Optional Accessories Condensate Drain Heat Cable Kits Self-limiting wattage heat cable prevents condensate drain from freezing in unconditioned areas. Available in 6 or 4 ft. lengths. Crawl Space Vent Drain Kit Allows venting through a crawl space for downflow applications. Includes or in. sanitary tee, in. PVC assembly, PCV boot and clamp. Kit for Canada is certified to ULC S66. Downflow Combustible Flooring Base Required for heating only units installed on combustible floors. Not required in add-on cooling applications. See Dimension Drawing. High Performance Economizer (Commercial Applications Only) Designed for applications requiring outdoor air to be utilized in a commercial HVAC system. Allows the entry of fresh outdoor air for free cooling, reducing the requirement for mechanical cooling. Heavy gauge galvanized steel cabinet lined with thick fiberglass insulation. Mixed air sensor, outdoor air sensor and 4VAC transformer furnished. Approved for California Title 4 building standards. ASHRAE 90.-00 compliant. See separate Product Specifications bulletin for additional information and available control and sensor options. NOTE - Economizer is not icomfort Communicating compatible. FILTER (not furnished) Filter and provisions for external mounting must be field provided. Optional Accessories Downflow Filter Cabinet Filter cabinet mounts directly on top of furnace. B and C width cabinets have two filters. Filter rails are furnished. Front access for servicing. Cleanble filter(s) are furnished. Low Leakage Cabinet All models have less than % air leakage and meet ANSI/ASHRAE Standard 9-00 Method of Test for Determining the Air Tightness of HVAC Equipment. EL96DFV / Page 8

SPECIFICATIONS Gas Heating Performance Model No. EL96DF045XV6BEL96DF070XV48BEL96DF090XV60CEL96DF0XV60C AHRI Ref. No. 49887 49888 56546 49880 AFUE 96% 96% 96% 96% High static - in. w.g. Connections in. Indoor Blower Electrical Data High Fire Input - Btuh 44,000 66,000 88,000 0,000 Output - Btuh 4,000 64,000 85,000 06,000 Temperature rise range - F 5-65 5-65 40-70 45-75 Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane Low Fire.5 / 0.0.5 / 0.0.5 / 0.0.5 / 0.0 Input - Btuh 9,000 4,000 57,000 7,000 Output - Btuh 8,000 4,000 56,000 70,000 Temperature rise range - F 0-50 5-55 0-60 5-65 Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane.7 / 4.9.7 / 4.9.7 / 4.9.7 / 4.9 Heating 0.8 0.8 0.8 0.8 Cooling.0.0.0.0 Intake / Exhaust Pipe (PVC) / / / / Gas pipe size IPS / / / / Condensate Drain Trap (PVC pipe) - i.d. /4 /4 /4 /4 with furnished 90 street elbow /4 slip x /4 Mipt /4 slip x /4 Mipt /4 slip x /4 Mipt /4 slip x /4 Mipt with field supplied (PVC coupling) - o.d. /4 slip x /4 MPT /4 slip x /4 MPT /4 slip x /4 MPT /4 slip x /4 MPT Wheel nom. diameter x width - in. 0 x 9 x 0 x x Motor output - hp / /4 Tons of add-on cooling -.5-4 - 5-5 Air Volume Range - cfm 545-60 575-800 890-0 860-80 Voltage 0 volts - 60 hertz - phase Blower motor full load amps 7.7 0..8.8 Maximum overcurrent protection 5 0 0 0 Shipping Data lbs. - package 6 64 76 NOTE - Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. INSTALLATION CLEARANCES Sides Rear Top/Plenum Front Front (service/alcove) Floor 0 inches (0 mm) 0 inches (0 mm) inch (5 mm) 0 inches (0 mm) 4 inches (60 mm) Combustible NOTE - Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ ANSI-Z.) or the National Standard of Canada CAN/CSA-B49. Natural Gas and Propane Installation Code. NOTE - In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/ANSI-Z.) or applicable provisions of local building codes. In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/CSA-B49.. Allow proper clearances to accommodate condensate trap and vent pipe installation. Clearance for installation on combustible floor if Optional Downflow Combustible Flooring Base is installed between furnace and combustible floor. Not required in add-on cooling applications if installed in accordance with local codes or National Fuel Gas Code ANSI-Z. or CAN/CGA-49.,.. Do not install the furnace directly on carpeting, tile, or other combustible materials other than wood flooring. EL96DFV / Page 9

OPTIONAL ACCESSORIES - ORDER SEPARATELY NOTE - FURNACES CANNOT BE TWINNED! CABINET ACCESSORIES B Width Models C Width Models Downflow Combustible Flooring Base M60 M6 High Performance Economizer (Commercial Only) 0U5 0U5 CONDENSATE DRAIN KITS Condensate Drain Heat Cable 6 ft. 6K68 6K68 4 ft. 6K69 6K69 Crawl Space Vent Drain Kit US 5W8 5W8 CONTROLS Canada 5Z70 5Z70 icomfort S0 Thermostat U67 U67 Discharge Air Temperature Sensor 88K8 88K8 icomfort E0 Smart Thermostat 5S6 5S6 Remote Outdoor Temperature Sensor (for dual fuel and EDA) X658 X658 Night Service Kit 4C99 4C99 FILTERS Downflow Filter Cabinet 5W07 5W08 TERMINATION KITS See Installation Instructions for specific venting information. Termination Kits - Direct Vent Applications Only Termination Kits - Direct or Non-Direct vent No. and Size of filter - in. () 6 x 0 x () 6 x 0 x Concentric US - in. 7M80 69M9 in. - - - 60L46 Canada - in. 44W9 44W9 in. - - - 44W9 Flush-Mount US -, -/ or in. 5W 5W Wall - Close Couple Wall - Close Couple WTK 4 Roof Termination Flashing Kit - Direct or Non-Direct Vent ( flashings) VENTING Canada -, -/ or in. 5W 5W US - in. G44 - - - in. 44J40 44J40 Canada - in. 0G8 - - - in. 8J0 8J0 Roof in. 5F75 5F75 Wall Ring Kit in. 5F74 5 5F74 in. 44J4 44J4 Flue Coupling in. 7H9 7H9 Left Side Vent Kit or in. 87W7 87W7 Optional for service diagnostics. Remote Outdoor Temperature Sensor is used with conventional (non-icomfort Communicating) outdoor units (sensor is furnished with icomfort Communicating outdoor units). Allows the thermostat to display outdoor temperature. Required in dual-fuel and EDA applications. Cleanable polyurethane, frame-type filter. 4 Kits contain enough parts for two, non-direct vent installations. 5 Non-direct vent only. NOTE - The curved exhaust pipe furnished with the Left Side Vent Kit counts as one additional in. diameter 90 elbow. When using in. diameter pipe, the furnished curved exhaust pipe and field provided fittings to transition from in. to in. count as 0 feet of equivalent pipe on all units. NOTE - Termination Kits (44W9, 44W9, 0G8, 5W, 5W9, 8J0) and Crawl Space Vent Drain Kit (5Z70) are certified to ULC S66 standard for use in Canada only. EL96DFV / Page 0

GAS HEAT ACCESSORIES Input High Altitude Pressure Switch Kit Natural Gas to LPG/Propane Kit LPG/Propane to Natural Gas Kit Natural Gas High Altitude Orifice Kit LPG/Propane High Altitude Orifice Kit Muffler (US Only) 450-7500 ft. 750-0,000 ft. 0-7500 ft. 0-7500 ft. 750-0,000 ft. 750-0,000 ft. 045 4A47 4A50 K5 77W09 7W7 K46 5Y66 (-inch) 070 4A55 4A56 K5 77W09 7W7 K46 5Y66 (-inch) 090 4A54 4A5 K5 77W09 7W7 K46 5Y66 (-inch) 0 4A46 4A5 K5 77W09 7W7 K46 5Y66 (-inch) 6A56 (-inch) Two-inch diameter muffler (5Y66) is optional for 0 input model with a maximum vent pipe length of up to 9 ft. Three-inch diameter muffler (6A56) is optional for 0 input model with a minimum vent pipe length of 0 ft. OUTDOOR TERMINATION KIT USAGE Input Size 045 070 090 0 Vent Pipe Diameter (in.) Flush Mount Kit 5W (US) 4 5W (CA) Standard Terminations Wall Kit Wall Ring Kit inch inch inch G44 (US) 4 0G8 (CA) 44J40 (US) 4 8J0 (CA) 5F74 Field Fabricated Exhaust Accelerator Size Required Concentric Terminations Concentric Kit -/ inch inch inch 7M80 (US) 4 44W9 (CA) 69M9 (US) 4 44W9 (CA) 60L46 (US) 4 44W9 (CA) YES YES YES YES -/ in. YES - - - - - - -/ YES YES YES YES -/ in. YES - - - - - - YES YES YES YES -/ in. YES - - - - - - YES YES YES YES -/ in. YES - - - - - - -/ YES YES YES YES -/ in. YES - - - - - - YES YES YES YES -/ in. YES - - - - - - YES - - - YES YES in. - - - YES YES -/ YES - - - YES YES in. - - - YES YES YES - - - YES YES in. - - - YES YES YES - - - YES YES in. - - - YES YES -/ YES - - - YES - - - in. - - - YES YES YES - - - YES - - - in. - - - YES YES NOTE - Standard Terminations do not include any vent pipe or elbows external to the structure. Any vent pipe or elbows external to the structure must be included in total vent length calculations. See Vent Length Tables. Requires field provided -/ in. outdoor exhaust accelerator. Concentric Kits 7M80 and 44W9 include -/ in. outdoor exhaust accelerator, required when used with 045 and 070 input models. Accelerator is not used with 090, 0, 5 input models. Flush Mount Kit 5W and 5W includes -/ in. outdoor exhaust accelerator, required when used with 045, 070 and 090 input models. Accelerator is not used with 0 or 5 input models. 4 Termination Kits 0G8, 44W9, 44W9, 5W and 8J0 are certified to ULC S66 standard for use in Canada only. VENT LENGTHS - UNINSULATED EXHAUST PIPE IN UNCONDITIONED SPACE Winter Design Temperatures to F 0 to F 0 to 0 F Vent Pipe Diameter PVC Unit Input Size 045 070 090 0 PolyPro InnoFlue Maximum Un-Insulated Exhaust Vent Length (ft.) PVC PolyPro InnoFlue PVC PolyPro InnoFlue PVC PolyPro InnoFlue in. 8 0 46 4 0 0 -/ in. 6 N/A 6 N/A 7 N/A 6 N/A in. 0 0 9 9 in. 9 9 7 8 5 7 4 -/ in. 7 N/A 4 N/A N/A 0 N/A in. N/A N/A 9 9 6 6 4 4 in. 6 4 0 9 6 8 5 -/ in. N/A N/A 7 N/A N/A N/A in. N/A N/A N/A N/A 8 8 7 7 NOTE - Concentric terminations are equivalent to 5 ft. of straight pipe and should be included when measuring total pipe length. Refer to 99% Minimum Design Temperature table provided in the current edition of ASHRAE Handbook-Fundamentals. PolyPro poly-propylene vent pipe is a registered trademark of DuraVent. Innoflue is a registered trademark of Centrotherm Eco Systems. EL96DFV / Page

VENT LENGTHS STANDARD TERMINATION AT ELEVATION 0-4500 ft. Pipe Size in. -/ in. in. Input 045 070 090 0 045 070 090 0 045 070 090 0 No. of 90 ELL 7 56 4 4 05 05 8 48 8 7 08 08 66 5 9 9 00 00 78 4 0 0 6 46 4 4 95 95 7 8 8 7 98 98 4 56 4 9 N/A 90 90 68 9 9 5 5 6 4 N/A 85 85 6 8 08 07 88 88 6 46 9 N/A 80 80 58 0 0 8 8 7 4 6 4 N/A 75 75 5 8 98 97 78 78 8 6 N/A N/A 70 70 48 9 9 7 7 9 6 N/A N/A 65 65 4 8 88 87 68 68 0 6 N/A N/A 60 60 8 8 8 6 6 STANDARD TERMINATION ELEVATION 450-0,000 ft. Pipe Size in. -/ in. in. Input 045 070 090 0 045 070 090 0 045 070 090 0 No. of 90 ELL 7 56 4 N/A 05 05 8 48 8 7 08 08 66 5 9 N/A 00 00 78 4 0 0 6 46 4 N/A 95 95 7 8 8 7 98 98 4 56 4 9 N/A 90 90 68 9 9 5 5 6 4 N/A 85 85 6 8 08 07 88 88 6 46 9 N/A 80 80 58 0 0 8 8 7 4 6 4 N/A 75 75 5 8 98 97 78 78 8 6 N/A N/A 70 70 48 9 9 7 7 9 6 N/A N/A 65 65 4 8 88 87 68 68 0 6 N/A N/A 60 60 8 8 8 6 6 CONCENTRIC TERMINATION AT ELEVATION 0-4500 ft. Pipe Size in. -/ in. in. Input 045 070 090 0 045 070 090 0 045 070 090 0 No. of 90 ELL 6 48 95 95 79 44 04 04 58 4 7 7 90 90 74 9 06 06 99 99 5 8 85 85 69 4 0 9 94 94 4 48 7 N/A 80 80 64 9 96 96 89 89 5 4 8 N/A 75 75 59 4 9 9 84 84 6 8 7 N/A 70 70 54 9 96 86 79 79 7 8 N/A 65 65 49 4 8 8 74 74 8 8 N/A N/A 60 60 44 9 76 76 69 69 9 8 N/A N/A 55 55 9 4 7 7 64 64 0 8 N/A N/A 50 50 4 N/A 66 66 59 59 CONCENTRIC TERMINATION ELEVATION 450-0,000 ft. Pipe Size in. -/ in. in. Input 045 070 090 0 045 070 090 0 045 070 090 0 No. of 90 ELL 6 48 N/A 95 95 79 44 04 94 58 4 7 N/A 90 90 74 9 06 06 99 99 5 8 N/A 85 85 69 4 0 0 94 94 4 48 7 N/A 80 80 64 9 96 96 89 89 5 4 8 N/A 75 75 59 4 9 9 84 84 6 8 7 N/A 70 70 54 9 86 86 79 79 7 8 N/A 65 65 49 4 8 8 74 74 8 8 N/A N/A 60 60 44 9 76 76 69 69 9 8 N/A N/A 55 55 9 4 7 7 64 64 0 8 N/A N/A 50 50 4 N/A 66 66 59 59 EL96DFV / Page

VENT LENGTHS (EXHAUST) - VENTILATED ATTIC OR CRAWLSPACE INTAKE - FEET STANDARD TERMINATION AT ELEVATION 0-0,000 ft. Pipe Size in. -/ in. in. Input 045 070 090 0 045 070 090 0 045 070 090 0 No. of 90 ELL 6 46 4 4 90 90 68 08 07 88 88 56 4 9 N/A 85 85 6 8 0 0 8 8 5 6 4 N/A 80 80 58 98 97 78 78 4 46 9 N/A 85 75 6 8 9 9 7 7 5 4 6 4 N/A 70 70 48 88 87 68 68 6 6 N/A N/A 65 65 4 8 8 8 6 6 7 6 N/A N/A 60 60 8 78 77 58 58 8 6 N/A N/A 55 55 N/A 7 7 5 5 9 6 N/A N/A 50 50 8 N/A 68 67 48 48 0 6 N/A N/A 45 45 N/A 6 6 4 4 EL96DFV / Page

DIMENSIONS 9/6 (4) Flue Condensate Trap Assembly Furnished for external field installation on either side of unit. (See installation instructions for additional information.) 7 (78) COMBUSTION INTAKE EXHAUST OUTLET -/6 (5) B RETURN OPENING 5 (7) -/4 (57) 9/6 (4) TOP VIEW A B FLOW 9/6 (4) 4-/ (4) -/ (8) Front Panel (5) 6-/4 (57) 7-/4 (705) 9-7/6 (494) 9/6 (4) 5 (8) -7/8 (48) 5-/6 () OPTIONAL LEFT SIDE VENT LOCATION (Kit Required) ELECTRICAL INLET (Either Side) -/6 (5) ALTERNATE RIGHT SIDE VENT LOCATION (Parts Furnished) (88) (5) Either Side GAS PIPING INLET (Either Side) ELECTRICAL INLET (Either Side) CONDENSATE TRAP CONNECTION (Either Side) 9-/8 () Right 6-9/6 (67) Left 6-7/6 (6) Either Side 9 (9) Either Side /4 (9) C Supply Air /4 (9) 9-/4 (489) Supply Air /4 (9) FRONT VIEW SIDE VIEW Model No. A B C EL96DF045XV6B EL96DF070XV48B EL96DF090XV60C EL96DF0XV60C in. mm in. mm in. mm 7-/ 446 6-/8 46 6 406 5 9-7/8 505 9-/ 495 EL96DFV / Page 4

OPTIONAL ACCESSORY DIMENSIONS DOWNFLOW FILTER CABINET B AND C WIDTH FURNACES (Two Filters) 0-/ (5) 7-/ (445) B Box (5) C Box FILTERS () 7-/ (445) 50-/ (8 ) (88) FURNACE FILTER ACCESS DOOR NOTE: Return Air Opening (W x D) B Box 6-/ x 9-5/8 (49 x 498) C Box 0 x 9-5/8 (508 x 498) DOWNFLOW COMBUSTIBLE FLOORING BASE -/ (8) SUPPLY OPENING DOWN FLOW FURNACE -/ (8) B 9-/6 (50) -/ (8) 7-/4 (69) -/6 (554) Front Of Furnace A -/ (8) TOP VIEW SIDE VIEW DOWNFLOW COMBUSTIBLE FLOORING BASE FLOOR OPENING Cabinet Width Catalog Number A B C in. mm in. mm in. mm B M60 9-9/6 497 6-9/6 4 8-/4 476 C M6 -/6 586 0-/6 50 -/4 565 (559) C EL96DFV / Page 5

DIMENSIONS - FURNACE/COIL COMBINED DIMENSIONS Furnace Width (88) Coil Height Overall Height Model Number Coil Width Furnace Width Coil Height Overall Height in. mm in. mm in. mm in. mm CR-4B-F 7-/ 446 7-/ 446 -/4 7 46-/4 75 CR-0/6B-F 7-/ 446 7-/ 446 6-/8 40 49-/8 48 CR-0/6C-F 5 5 6-/8 40 49-/8 48 CR-48B-F 5 7-/ 446 0 508 5 46 CR-48C-F 5 5 0 508 5 46 CR-50/60C-F 4-/ 6 5-5/8 600 56-5/8 76 Coil Width EL96DFV / Page 6

OPTIONAL ACCESSORY DIMENSIONS FLUSH-MOUNT VENT TERMINATION KIT 5W (US) or 5W (CANADA) With or -/ in. (5 or 64 mm) PVC pipe Exhaust Intake (Behind Plate) Seal all openings (typical) With in. (76 mm) PVC pipe Exhaust Intake (Behind Plate) -/8 (60) (05) minimum (recommended) (5) PVC pipe (76) PVC pipe NOTE - PVC pipe and fittings are not furnished When required Use and must be field furnished. Field Provided -/ to in. (64 to 5 mm) Coupling -/ (64) PVC pipe MUFFLERS 5Y66 - -inch 6A56 - -inch -Inch - 8-/4 (476) -Inch - 5 (65) 4-/ (4) (Installed Vertically in the Exhaust Pipe) NOTE - Two-inch mufflers do not have reducers at each end. EL96DFV / Page 7

OPTIONAL ACCESSORY DIMENSIONS CONCENTRIC WALL TERMINATION APPLICATIONS CONCENTRIC ROOF TERMINATION APPLICATIONS EXHAUST OUTSIDE WALL INTAKE EXHAUST (05) Minimum Above Average Snow Accumulation FLASHING (Not Furnished) INTAKE CLAMP (Not Furnished) INTAKE (05) Minimum Above Grade or Average Snow Accumulation CLAMP SHEET METAL STRAP (Clamp and sheet metal strap must be field installed to support the weight of the termination kit.) GRADE ELBOW (Field Supplied) 7M80 / 69M9 / 44W9 inch kits 60L46 / 44W9 inch kits See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. A B / (89) in. kits 4 / (4) in. kits TERMINATION ASSEMBLY (Furnished) 6 / (65) INTAKE 6 (5) EXHAUST Outdoor Exhaust Accelerator included with 7M80/44W9 Cat. No. 7M80 69M9 44W9 (Canada) A B in. mm in. mm /8 848 6 /4 45 9 77 5 / 94 60L46 8 7/8 987 /6 58 44W9 (Canada) 6 /8 98 9 / 495 NOTE Typical illustration for dimensions only. Design may vary depending on kit ordered. WALL ASSEMBLY TERMINATION KIT RING KIT 5F74 inch (5 mm) See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. DIRECT VENT APPLICATION NON-DIRECT VENT APPLICATION NOTE - EXHAUST PIPE SHOWN Kit Contains Enough Parts For Two Installations in. (05 mm) - in. (5 mm) dia. exhaust pipe 0 in. (508 mm) - in. (76 mm) dia. exhaust pipe maximum length without support in. (05 mm) - in. (5 mm) dia. exhaust pipe 0 in. (508 mm) - in. (76 mm) dia. exhaust pipe maximum length without support 8 in. (0 mm) minimum 6 in. (5 mm) maximum NOTE in. (05 mm) minimum height above average snow accumulation (from bottom of vent pipe). NOTE in. (05 mm) minimum height above average snow accumulation (from bottom of vent pipe). EL96DFV / Page 8

OPTIONAL ACCESSORY DIMENSIONS WALL TERMINATION KITS (CLOSE-COUPLE) EXTENDED VENT FOR GRADE CLEARANCE inch (5 mm) G44 (US) inch (76 mm) 44J40 (US) See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. If Intake and Exhaust Pipe is less than in. (05 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. WALL SUPPORT 8 (0) MIN. Between Ends of Exhaust and Intake Pipe (05) MAX. for (5) Dia. Exhaust 0 (508) MAX. for (76) Dia. Exhaust (05) INTAKE 6 (5) Maximum EXHAUST INTAKE 5 (7) / () FOAM INSULATION (Field Furnished) EXHAUST 8 (0) MIN. (05) Minimum Above Grade or Average Snow Accumulation GRADE 5-/ (40) (05) Minimum Above Grade or Average Snow Accumulation GRADE (05) MAX. for (5) Dia. Exhaust 0 (508) MAX. for (76) Dia. Exhaust WALL TERMINATION KITS (CLOSE-COUPLE) EXTENDED VENT FOR GRADE CLEARANCE inch (5 mm) 0G8 (WTK Canada) inch (76 mm) 8J0 (WTK Canada) See Installation Instructions for additional information. Note - Field provided reducer may be required to adapt larger vent pipe size to termination. If Intake and Exhaust Pipe is less than in. (05 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. WALL SUPPORT INTAKE 6 (5) Maximum (05) MAX. for (5) Dia. Exhaust 0 (508) MAX. for (76) Dia. Exhaust 6 (5) MIN. EXHAUST INTAKE 5 (7) (05) / () FOAM INSULATION (Field Furnished) EXHAUST 6 (5) MIN. (05) MAX. for (5) Dia. Exhaust 0 (508) MAX. for (76) Dia. Exhaust (05) Minimum Above Grade or Average Snow Accumulation GRADE 5-/ (40) (05) Minimum Above Grade or Average Snow Accumulation GRADE EL96DFV / Page 9

BLOWER DATA EL96DF045XV6B BLOWER PERFORMANCE (less filter) BOTTOM RETURN 0 through 0.8 in. w.g. (Heating) and 0 through.0 in. w.g. (Cooling) External Static Pressure Range Heating Speed DIP Switch Settings First Stage Heating Speed - cfm HEATING Second Stage Heating Speed - cfm +4% 90 50 +8% 855 095 +% 80 040 +6% 770 990 Factory Default 745 95 6% 700 880 % 665 80 8% 65 755 Cooling Speed DIP Switch Settings First Stage Cooling Speed - cfm COOLING Second Stage Cooling Speed - cfm Low Medium-Low Medium-High High Low Medium-Low Medium-High High + 640 755 850 975 895 050 0 60 Factory Default 580 695 780 880 805 965 05 50 545 645 70 795 75 865 000 0 Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings. Factory default setting. NOTES - The effect of static pressure is included in air volumes shown. First stage HEAT is approximately 9% of the same second stage HEAT. First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is selectable at 8%, 8%, 70% and 00% of the selected second stage cooling speed - minimum 50 cfm. Lennox iharmony Zoning System Applications - Minimum blower speed is 50 cfm. EL96DF045XV6B BLOWER MOTOR WATTS (COOLING) Cooling Speed DIP Switch Settings + Setting Cooling Speed Factory Default Cooling Speed Setting Cooling Speed First Stage Motor Watts @ Various External Static Pressures - in. wg. Second Stage 0 0. 0. 0. 0.4 0.5 0.6 0.7 0.8 0 0. 0. 0. 0.4 0.5 0.6 0.7 0.8 0.9.0 Low 8 44 60 77 9 8 44 58 59 77 97 8 60 8 97 6 4 56 Med-low 47 67 88 05 8 6 79 0 54 77 0 8 50 77 99 0 44 70 Med-High 69 9 60 8 04 0 46 99 5 48 75 08 40 60 90 407 4 445 High 00 7 5 7 9 5 40 60 86 9 6 79 49 45 488 5 56 5 54 Low 7 4 5 65 8 97 48 6 79 98 5 4 64 85 0 9 46 59 Med-low 5 50 70 85 05 5 40 55 75 99 5 48 67 88 6 56 79 0 7 Med-High 54 7 95 48 7 89 0 47 70 97 5 78 0 0 55 7 98 High 74 96 8 4 68 90 5 6 9 58 0 5 56 90 40 46 448 465 Low 7 49 6 75 9 07 6 46 64 8 0 5 4 55 74 96 05 Med-low 8 45 6 77 9 9 44 59 7 9 4 60 84 04 47 6 8 Med-High 40 57 77 9 0 48 65 86 0 6 8 05 6 5 7 94 9 4 High 57 76 97 9 6 56 79 95 4 55 74 07 5 65 9 4 70 86 44 EL96DFV / Page 0

BLOWER DATA EL96DF070XV48B BLOWER PERFORMANCE (less filter) BOTTOM RETURN 0 through 0.8 in. w.g. (Heating) and 0 through.0 in. w.g. (Cooling) External Static Pressure Range Heating Speed DIP Switch Settings First Stage Heating Speed - cfm HEATING Second Stage Heating Speed - cfm +4% 085 65 +8% 00 55 +% 950 450 +6% 90 65 Factory Default 850 0 6% 790 5 % 740 5 8% 680 060 Cooling Speed DIP Switch Settings First Stage Cooling Speed - cfm COOLING Second Stage Cooling Speed - cfm Low Medium-Low Medium-High High Low Medium-Low Medium-High High + 740 95 055 55 0 40 575 800 Factory Default 660 80 940 0 995 0 40 650 575 75 850 995 880 085 90 460 Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings. Factory default setting. NOTES - The effect of static pressure is included in air volumes shown. First stage HEAT is approximately 9% of the same second stage HEAT. First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is selectable at 8%, 8%, 70% and 00% of the selected second stage cooling speed - minimum 80 cfm. Lennox iharmony Zoning System Applications - Minimum blower speed is 80 cfm. EL96DF070XV48B BLOWER MOTOR WATTS (COOLING) Cooling Speed DIP Switch Settings + Setting Cooling Speed Factory Default Cooling Speed Setting Cooling Speed First Stage Motor Watts @ Various External Static Pressures - in. wg. Second Stage 0 0. 0. 0. 0.4 0.5 0.6 0.7 0.8 0 0. 0. 0. 0.4 0.5 0.6 0.7 0.8 0.9.0 Low 68 88 09 54 78 99 8 44 69 08 44 70 0 4 78 40 4 457 Med-low 9 0 47 7 98 0 54 74 04 57 76 6 70 98 47 470 49 5 558 598 Med-High 0 5 80 0 54 8 8 44 80 90 48 47 56 574 6 659 706 745 788 80 High 4 7 84 4 5 90 44 456 474 67 604 66 7 775 85 869 908 95 88 864 Low 5 54 74 9 09 9 47 6 9 04 7 6 89 9 54 78 4 69 400 Med-low 75 00 5 40 65 90 0 0 55 88 0 50 97 7 74 99 4 454 486 5 Med-High 99 9 59 79 09 6 70 9 9 04 40 76 48 450 495 5 567 6 67 674 High 57 84 64 85 5 65 406 49 454 469 57 589 64 669 74 770 88 8 840 Low 7 49 6 7 98 6 5 55 68 86 5 6 86 06 6 57 8 06 9 Med-low 67 87 09 54 77 99 8 9 56 87 6 58 88 5 5 85 409 44 Med-High 8 05 7 5 76 96 4 69 6 44 90 5 64 40 45 465 485 56 556 High 07 4 64 95 4 6 8 47 9 75 40 444 48 56 570 6 656 680 78 EL96DFV / Page

BLOWER DATA EL96DF090XV60C BLOWER PERFORMANCE (less filter) BOTTOM RETURN 0 through 0.8 in. w.g. (Heating) and 0 through.0 in. w.g. (Cooling) External Static Pressure Range Heating Speed DIP Switch Settings First Stage Heating Speed - cfm HEATING Second Stage Heating Speed - cfm +4% 45 895 +8% 55 85 +% 80 740 +6% 5 660 Factory Default 60 575 6% 055 455 % 00 65 8% 950 65 Cooling Speed DIP Switch Settings First Stage Cooling Speed - cfm COOLING Second Stage Cooling Speed - cfm Low Medium-Low Medium-High High Low Medium-Low Medium-High High + 5 65 400 600 600 750 970 0 Factory Default 005 50 75 450 450 60 80 975 890 065 50 70 70 450 645 80 Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings. Factory default setting. NOTES - The effect of static pressure is included in air volumes shown. First stage HEAT is approximately 9% of the same second stage HEAT. First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is selectable at 8%, 8%, 70% and 00% of the selected second stage cooling speed - minimum 450 cfm. Lennox iharmony Zoning System Applications - Minimum blower speed is 450 cfm. EL96DF090XV60C BLOWER MOTOR WATTS (COOLING) Cooling Speed DIP Switch Settings + Setting Cooling Speed Factory Default Cooling Speed Setting Cooling Speed First Stage Motor Watts @ Various External Static Pressures - in. wg. Second Stage 0 0. 0. 0. 0.4 0.5 0.6 0.7 0.8 0 0. 0. 0. 0.4 0.5 0.6 0.7 0.8 0.9.0 Low 79 08 44 6 07 4 6 9 75 99 66 99 449 48 5 584 605 644 680 Med-low 0 56 87 6 79 9 68 40 87 409 47 5 56 606 650 688 76 76 800 Med-High 55 0 5 9 7 69 407 45 50 547 577 6 667 744 795 85 87 90 950 96 High 68 99 66 99 449 48 5 584 605 780 775 8 898 94 994 048 07 08 080 07 Low 56 86 40 70 00 59 8 86 9 70 08 6 90 4 489 57 555 590 Med-low 9 8 5 95 54 8 06 44 78 04 65 40 450 50 544 59 640 665 698 Med-High 6 0 8 60 0 4 8 46 446 475 58 58 66 66 686 747 780 8 855 High 8 9 70 08 6 90 4 489 57 576 60 654 704 756 809 87 90 99 97 975 Low 48 69 0 0 5 75 0 8 49 8 55 8 59 99 40 76 40 48 476 Med-low 65 94 50 85 0 50 78 96 77 05 67 04 5 90 40 486 55 56 587 Med-High 9 8 5 95 54 8 06 44 0 9 49 468 5 568 599 647 678 7 High 6 55 8 59 99 40 76 40 446 475 58 58 66 66 686 747 780 8 855 EL96DFV / Page

BLOWER DATA EL96DF0XV60C BLOWER PERFORMANCE (less filter) BOTTOM RETURN 0 through 0.8 in. w.g. (Heating) and 0 through.0 in. w.g. (Cooling) External Static Pressure Range Heating Speed DIP Switch Settings First Stage Heating Speed - cfm HEATING Second Stage Heating Speed - cfm +4% 55 05 +8% 445 95 +% 70 855 +6% 00 760 Factory Default 0 645 6% 5 545 % 070 40 8% 000 5 Cooling Speed DIP Switch Settings First Stage Cooling Speed - cfm COOLING Second Stage Cooling Speed - cfm Low Medium-Low Medium-High High Low Medium-Low Medium-High High + 095 65 95 585 585 790 990 80 Factory Default 965 0 85 440 440 60 845 005 860 05 0 75 75 475 655 845 Cooling and heating speeds are based on a combination of DIP switch settings on the furnace control. Refer to Installation Instructions for specific DIP Switch Settings. Factory default setting. NOTES - The effect of static pressure is included in air volumes shown. First stage HEAT is approximately 9% of the same second stage HEAT. First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is selectable at 8%, 8%, 70% and 00% of the selected second stage cooling speed - minimum 450 cfm. Lennox iharmony Zoning System Applications - Minimum blower speed is 450 cfm. EL96DF0XV60C BLOWER MOTOR WATTS (COOLING) Cooling Speed DIP Switch Settings + Setting Cooling Speed Factory Default Cooling Speed Setting Cooling Speed First Stage Motor Watts @ Various External Static Pressures - in. wg. Second Stage 0 0. 0. 0. 0.4 0.5 0.6 0.7 0.8 0 0. 0. 0. 0.4 0.5 0.6 0.7 0.8 0.9.0 Low 7 99 47 66 0 40 7 0 7 48 80 74 49 469 5 548 594 69 677 Med-low 7 59 98 5 56 0 5 65 90 409 47 496 5 587 6 665 7 74 78 805 Med-High 6 04 4 87 6 7 408 446 487 56 589 65 70 755 808 860 888 9 970 007 High 4 80 74 49 469 5 548 594 866 850 95 96 00 056 09 7 4 6 Low 57 88 7 40 65 96 59 8 67 4 44 9 80 405 467 497 59 58 Med-low 77 47 7 09 50 8 7 45 75 48 48 447 505 546 597 6 668 76 Med-High 54 99 0 68 00 7 4 46 49 547 57 68 666 70 745 777 89 860 High 67 4 44 9 80 405 467 497 60 66 688 70 787 8 880 94 96 994 0 Low 44 67 99 5 44 67 97 5 45 6 65 0 6 05 4 7 47 45 479 Med-low 66 97 5 86 6 47 75 0 87 9 7 08 60 9 4 479 54 559 588 Med-High 77 47 7 09 50 8 7 45 08 4 90 40 490 58 569 67 640 69 74 High 7 65 0 6 05 4 7 47 46 49 547 57 68 666 70 745 777 89 860 EL96DFV / Page