OEM Sensors for HVAC manufacturers Pool water

Similar documents
Flow Switches. Series VHS, VKS, VH

OEM Sensors for HVAC manufacturers Heat recovery Chiller

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

SIKA VK300 OR VK325 SERIES FLOW SWITCH Operating Manual

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

FSW300 Series Flow Switch

1592P01. for liquids in piping DN

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

RA 2000 Series RA 15/6T & TB Conversion Valve

A.YITE GROUP (Hongkong & Shanghai)

RA15/6T & TB Conversion Valve

A.YITE GROUP (Hongkong & Shanghai)

Paddle Flow Switch. Pressure Control Flow Switch

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

Balancing & Control. Frese OPTIMIZER 6-way. Pressure Independent Control Group

Brawa-Mix Thermostatic mixing valves

Safety vacuum drying oven for flammable solvents


GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

AUTOMATIC FILTERS. AG series HECTRON

SPRINKLER SYSTEM SOLUTIONS. Water-based Fire-Fighting Sprinkler System PROVEN TECHNOLOGY

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

FLOW SWITCHES AND LEVEL SWITCHES CATALOG CATALOGUE DES DÉTECTEURS DE DÉBIT ET DE NIVEAU

PORTABLE DEW POINT MONITOR

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Calio-Therm S NC/NCV Type Series Booklet

FCHM Hydromatic Pump Control Module

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Mikrotherm. Manual Radiator Valves With presetting

Fan speed controller Type Saginomiya XGE

Differential pressure gauge with electrical contact type Model: P650 series

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

VST Series. INAIL approved and calibrated safety valves. Technical Data Sheet. WattsIndustries.com

OO Measuring range from bar rel. OO Large selection of pressure sensors. OO Automatic sensor recognition

product overview ProControl

Instructions for CO 2 Cold Trap System. Part No

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Vacuum drying oven for non-flammable solvents

13.2 Component Illustrations, Parts Lists, and Part Numbers

SOLARLOK Interconnection System Installation Manual

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

EN: This Datasheet is presented by the m anufacturer. Please v isit our website for pricing and availability at ore.hu.

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

Pool & Spa The Duratech Heat Pumps

caleffi hydronic valves page 1 of 12

Pool & Spa The Duratech Heat Pumps

Instructions for installation and use RE/I. Industrial electric heater for swimming pool

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

OWNER S MANUAL LOW-POWER SCREW-IN AND FLANGE-MOUNTED IMMERSION HEATERS (MAXIMUM 3 PINS)

Bulletin , March Electric Hot Gas Bypass Valves

Installation, commissioning and servicing instructions

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

M7100 Pressure Transducer

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

VD 53 - Vacuum drying oven for non-flammable solvents

HERZ Regulating valve 4002

GREEN BOY LED Specifications as of 8/2012 Please see separate spreadsheet for full part number listing

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Dräger Polytron 8310 Stationary gas detector (DSIR)

manifold, for radiators

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

Zettler Magnetics, Inc. By Anthon Vermaerke

Series F61. Liquid Flow Switches. Feature and Benefits. T-body and Pipe-insert types available

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

mlc-kit mini Liquid Cooling Kit

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10

Worldwide Contacts.

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

INSTRUCTION MANUAL FLOAT TYPE LEVEL SWITCHES HITROL CO., LTD.

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

KOBOLD PSR/PS FLOW SWITCH

Pressure Measurement Solutions HVAC AND REFRIGERATION SYSTEMS.

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated

The heart of electric appliances ELECTRIC WATER HEATING MADE IN ITALY

DESCRIPTION FEATURES WARNINGS APPLICATIONS

M5200 Industrial Pressure Transducer

Advanced Water Cooling Systems for Power Electronics High performance at heat source High reliability in cooling solutions

ProRadiant Controls, Valves and Actuators

November 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES

WAL-RICH CORPORATION SINCE 1950

Mounting and Operating Instructions EB 2231 EN

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

INSTALLATION INSTRUCTIONS

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

CII FCAC-150 Series Relay

HERZ Differential Pressure Control Valve 4002

SMALL PRESSURE CONTROLS (DISC TYPE)

Yoshikazu Tanabe On behalf of Mr.Shigeo AIBA

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

SECTION METERS AND GAGES FOR HVAC PIPING

Transcription:

OEM Sensors for HVAC manufacturers Pool water

2 Pool water Typical flow switch application Product features Pump monitoring For pool heaters or water disinfection Protection against overheating, dry-running and gas formation Installation with union nut or push-in Paddle reset with magnetic force More than 1 000 000 switching cycles (load-dependent) Metal-free for seawater pools Proven in the market leader s pool heaters VKL05 for pool heat pumps The flow switches are typically utilised in pool heaters or pool water disinfection units. They can prevent overheating (heaters) or overdosing (disinfectors). The flow switch monitors the flow rate and can easily detect pump breakdowns. The inexpensive insertion installation into DN50 or DN65 plastic pipes is the most common kind of installation. Metal free versions are suitable for sea water pools. Application & Information 03/2018

3 The pump monitoring is not affected by different vertical hights of pool and heater. Outside air VKL05 Compression Evaporator Condenser Pump Expansion Application & Information 03/2018

4 Flow monitoring Flow switches VKL05 // for insertion installation VKL05 Your advantages Series VKL05 / VKL05 Push-In Direct installation into pipe lines DN 50 150 Optional: Push-In installation Sealed with integrated O-ring Technical data VKL05 / VKL05 Push-In Switching function Contact closes at increasing flow Nominal diameter range Applicable in DN 50...150 Pressure rating PN 10 Temperature ranges Medium -20...70 C Ambient -20...70 C Electrical data Electrical connection Degree of protection EN 60529 Max. Switching current Max. Rating Max. Switching voltage Protection class EN 60730-1 1.5 m PVC jacket cable IP65 1 A 26 VA, 20 W 230 VAC, 48 VDC Class II Technical datasheet 03/2019

Flow monitoring Flow switches 5 VKL05 VKL05 Push-In Female socket design Materials in contact with fluid Type VKL05 VKL05 Push-In Body Paddle Pin Magnet Hard ferrite O-ring EPDM Soldering adapter Brass CW614N Process connection Brass CW614N or stainless steel 1.4571 Order code Type VKL05 VKL05M1P2BP Process connection Union nut G¾ Threaded adapter G½ brass Threaded adapter G½ stainless steel Soldering adapter Push-In for manifold mounting U10 R21 R23 D11 H20 Example order number VKL05M1P2BP U10 Technical datasheet 03/2019

6 Flow monitoring Flow switches // for insertion installation Your advantages Series Direct installation into pipe lines DN 50 150 Sealed with integrated O-ring Technical data Switching function Contact closes at increasing flow Nominal diameter range Applicable in DN 50...150 Pressure rating PN 10 Temperature ranges Medium -20...100 C Ambient -20...70 C Electrical data Electrical connection 1.5 m PVC jacket cable Degree of protection EN 60529 IP65 Max. Switching current Max. 1 A Max. Rating Max. 26 VA, 20 W Max. Switching voltage 230 VAC, 48 VDC or 24 VAC, 42 VDC Protection class EN 60730-1 Class II or Class III Approvals Technical datasheet 03/2019

Flow monitoring Flow switches 7 Materials in contact with fluid Type Body Paddle Pin Stainless steel 1.4571 or titanium Magnet Hard ferrite O-ring EPDM Soldering adapter Brass CW614N Process connection Brass CW614N or stainless steel 1.4571 Order code Type with titanium pin M2P2 M2B2 Switching voltage 230 VAC, 48 VDC 24 VAC, 42 VDC AP BP Process connection Union nut G¾ Threaded adapter G½ brass Threaded adapter G½ stainless steel Soldering adapter U10 R21 R23 D11 Example order number M2P2 AP U10 Technical datasheet 03/2019

SIKA Headquater Struthweg 7-9 34260 Kaufungen / Germany Phone +49 5605 803-0 Fax +49 5605 803-555 email: info@sika.net SIKA Worldwide SIKA Austria Phone +43 1865 2627 Fax +43 1865 2627 email: holzer@sika.net www.sika-messtechnik.at SIKA Instruments Ltd. UK Phone +44 1908 320265 email: thomas@sika-instruments.co.uk SIKA France s.a.r.l. Phone +33 140 3808-08 Fax +33 140 3423-90 email: sika.fr@wanadoo.fr SIKA USA Inc. Phone +1 262 886-2695 Fax +1 262 898-0101 email: info@sika-usa.com www.sika-usa.com SIKA Greater China Phone +86 10 6417 6123 Fax +86 10 6416 5123 email: info@sika-china.com.cn www.sika-china.com.cn SIKA Korea Ltd. Phone +82 31 243 1035 Fax +82 31 243 1066 email: peter@sika-korea.com www.sika-korea.com SIKA Indonesia Phone +62 21 829-4230 Fax +62 21 829-8464 email: sika.ind@gmail.com SIKA Philippines Phone +63 998 8288722 email: sika@rwkc.de SIKA Nordics Phone +46 70 5605-862 email: per@sika-instruments.se Edition 02/2019 KAT600HVAC0ENG