Advantages of R290 (Propane) and other hydrocarbons

Similar documents
Aircooled Units. AirPLUS Aircooled scroll chiller. Freecooling options: liquid control. Freecooling options: fans control. Noise \\ Efficiency options

Select watercooled scroll chiller or remote condenser scroll chiller. and build up a chilled water station adding modules.

The natural solution for domestic refrigeration

Process glycol chillers

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

Be sustainable while protecting your business

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Brazed Plate Heat Exchanger for CO Applications

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.

Hydrocarbons as refrigerants

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

AMONUM chillers. Eco-friendly cooling in compact packaging, easy maintenance and safe. Optimal use of energies. engie-refrigeration.

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

DC Inverter Smart VRF Products(R410A)

PRODUCT GUIDE

ENVIRONMENT-FRIENDLY HEATING WITH R290 HEAT PUMPS. Dr. Joachim Maul - Brussels, 15th of October 2013

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

Chapter 2. Alternatives to HCFCs and their Characteristics

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

HITACHI PRODUCT NEWS. Summary

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

GP SERIES Packaged Chillers

Aquaflair TRAC-TRAF-TRAH

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

WATE R -C OOLE D WATE R C H ILLE R S

AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

3 rd Generation of VRV. The professional solution for your professional project

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Go Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

All Chiller Products. Water Cooled and Air Cooled Modular Chillers Available in 208, 230, 460 & 575 Volts Application Ranges from 30 to 1,000 Tons

Neosys Product catalogue

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

The lowest energy consumption when using R290 LBP fixed speed compressors in a plug in ice cream conservator

EN aquatech.piovan.com

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Water-cooled chillers with High Speed Centrifugal Compressors

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

Emerson R290 Solutions for Commercial Refrigeration Applications

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

This presentation is posted for public use. ACEEE does not endorse any product or service.

Water (R718) The Safe & Natural Refrigerant. echiller Future Proof Refrigeration

YORK Close Control units

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed.

Innovation for a Better & Greener Future

SyScroll 40 to 75 Air NEW

Integrated VarIable refrigerant flow ahu/pau (r410a)

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Natural Refrigerants.

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

THE BIG FIVE NATURAL REFRIGERANTS IN DIFFERENT INDUSTRIAL APPLICATIONS. MAYEKAWA EUROPE S.A.,Leuvensesteenweg 605, 1930 Zaventem, Belgium

ARV.

Natural Refrigeration with Hydrocarbons Emerson s R290 Solutions

Environmentally friendly refrigeration systems for industrial use

Air-cooled Screw Chillers Model RTAF G Process

The refrigerant circuit was studied in detail. Each step is verified, ensuring that each unit is perfectly leak-tight.

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over

50A KP 70A KP 90A KP 120A KP 150A KP 210A

Product Line Introduction. Karl Zhang Technical support engineer

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

LG Electronics AE Company, Commercial Air Conditioning

Emerson Superheat Control. The smart solution for your application

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

ACMVTECH HIGH EFFICIENCY UNITARY AHU

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

H4T R410A. refrigerant

Index Features and advantages... 3 General characteristics... 5 Nomenclature... 9 Technical Specifications Sound levels...

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

LG Electronics AE Company, Commercial Air Conditioning

Air Cooled Scroll Chiller

Air-cooled modular Chiller. Nick Technical Engineer

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

NECS-W. Climaveneta Technical Bulletin NECS_W 0152_0612_200907_GB. Water-cooled liquid chillers and water-to-water heat pumps ,4-186 kw

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation


Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series)

Blue Box Epsilon Echos +

XStream Water-cooled screw chillers and Water/Water Heat pumps

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

Transcription:

R290 Propane 2017

Why R290 (Propane)? F-Gas regulation 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% HFC refrigerants placement on EU market (% to average 2009-2012) 2015 2016 2017 2018 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 HFC refrigerants traditionally used in chillers and heat pumps are subject to phase down in EU, US, China and other countries due to high GWP (Global warming potential) value. The goal is to decrease CO2 equivalent. The total HFC placement on the EU market will be gradually reduced to 31% of the baseline (average placement in 2009-2012) in 2024. The owners of HFC charged chillers will face: \\ Higher taxes for refrigerant charge \\ Higher fees for leakages \\ Higher refrigerant prices \\ Higher components cost HFC refrigerants with high GWP will be prohibited following R22. Advantages of R290 (Propane) and other hydrocarbons GWP=3 Global warming potential ODP=0 Ozone deplition potential R290 (Propane) - is the best alternative to HFC refrigerants for air conditioning and heat pump application. The units have traditional design. Thermodynamical properties are very close to HFC refrigerants. Felzer also manufactures units on other hydrocarbons - R1270 (propylene) and R600a (Isobutane). They are better suit for industrial low and high liquid temperature applications. R290 (Propane) has lower operating pressure and lower oil temperature compare to commonly used HFCs. That means that your piping and compressors will work longer. R290 - is a high purity (99,97%) grade of propane. Do not use low purity Propane grades as a refrigerant.

Our products // Aircooled chillers AirGREEN \\ Reciprocating compressors \\ Microchannel condensers \\ Brazed plate evaporators and superheaters // Watercooled chillers WaterGREEN \\ Reciprocating compressors \\ Brazed plate evaporators, condensers and superheaters // Water-to-water heatpumps WaterGREEN HP \\ Reciprocating compressors \\ Brazed plate evaporators, condensers and superheaters // Custom units // High and low chilled liquid temperatures. // Air-to-water and high temperature heatpumps. // R1270 (Propylene) and R600a (Isobutane). // Screw compressor units upto 2000 kw.

Design features High efficiency reciprocating compressors. 2-6 capacity steps in basic version. Possible to repair in case of failure. Automatic oil level control. Brazed plate heat exchangers (BPHE). Stainless steel and copper from the water side. Possible to use with stainless steel piping. Electronic expansion valve. Specially ajusted for R290 application. RS485 modbus in basic version. All units are supplied with compressor area enclosures. All the necessary safety features are included in the basic version. Factory packed water-to-water units can be easily moved with hydraulic pallet jack. Size with wooden pack is only 880x1900 mm, so the units fit standard doorways. For fast movement and location inside the buildings.

Safety features Propane - is it safe? Yes. Propane under pressure is widely used in a variety of residential and commercial applications. Now hydrocarbons are used in residential freezers as refrigerant. So it s safe to use propane chiller or heatpump. But some additional safety measures shall be considered based on local requirements. We have made risk assement of all of our products and as a result a group of safety features were realised in our units. Propane is not explosive if concentration is too low or too high. The goal is to prevent explosive concentration in case of leakage, to prevent sparks and openfire near leackage and to ventilate the leaked gas to the safe, well ventilated space. Refrigerant leak detector in the unit to detect the leakage ATEX sensors, switches and other critical equipment to prevent sparks Fan (ATEX on indoor) for ventilation of the leaked gas from the unit to the duct Safety valve piping to evaquate refrigerant in case of overpressure

Superheaters // PB & PF lines PB unit with integrated superheater heat exchanger PF unit with superheat only in evaporator R290 systems require higher superheat compare to HFC systems. We have two product lines. In PF units all superheat is achieved in evaporator. In PB units the superheat in evaporator is lower. And the final superheat on compressor suction line is produced in special heat exchanger. That allows to rise the evaporation pressure and efficiency of the unit. So if you would like to receive more efficeint unit choose PB product line. If you look for cost effective solution choose PF. // Inverter option All Felzer R290 units are available with inverter option. In basic version the capacity of the units is controled in steps using cylinder cuttoff. System may be improved by frequncy control of compressors from 30 to 70Hz (25 to 87Hz on some models). Remote frequency drive will be integrated in electrical cabinet outside the compressor compartment. The following advantages may be received by final customer: \\ Infinite capacity control \\ Higher part load energy efficiency // Operation without additional pressure fluctuation // Steady suction pressure and superheat // Smaller temperature difference at heat exchanger (higher suction and lower discharge pressure) \\ Higher capacity -> smaller unit sizes // Operation with frequency higher than 50Hz in extreme temperature or extreme capacity request periods \\ Soft start function // Reduced starting current with full motor torque // Reduced mechanical load // Minimised danger of liquid slugging during start-up

Options // Freecooling on aircooled and watercooled chillers Cooling load FREE COOLING Return water Temperature MECHANICAL COOLING Freecooling allows to chill water or brine by the air without using compressors. Significant power savings can be achieved if the unit is in operation in the midseason and wintertime. Available on watercooled chillers in separate modules (controlled from chiller controller) with inverter condenser pump. And on aircooled chillers integrated in the unit. Total FC Temperature Ambient temperature // EC fans and high-efficiency diffusers on aircooled chillers // Touchscreen, BACnet, LONworks - Smart features Number of smart features can be optionally installed to connect the unit to BMS (building management system), control it from the WEB, or make human control more user friendly. // Operation down to -35 C with condenser bypass If your unit shall work in the wintertime but freecooling is not aplicalable (cold brine, icebanks, etc.) condenser bypass and electrically heated receiver with a set of control valves may be integrated. With EC fans these units will work even in -35 C. // Hydraulic modules and other useful options (see selection soft)

Air-to-water units PB // Reciprocating product line AirGREEN PB 0120.1 0150.1 0200.1 0250.1 0300.1 0240.2 0300.2 0350.1 0400.2 0400.1 0500.2 Aircooled chillers capacities. User water 12/7 C, air 35 C Cooling capacity, kw 34,2 37,4 42,7 54,0 64,5 68,4 74,8 85,5 85,4 95,6 108,0 Power input, kw 10,4 11,7 13,5 18,0 19,8 20,7 23,4 27,2 27,0 31,1 36,0 EER 3,30 3,20 3,16 3,00 3,26 3,30 3,20 3,14 3,16 3,07 3,00 Number of compressors 1 1 1 1 1 2 2 1 2 1 2 Number of circuits 1 1 1 1 1 2 2 1 2 1 2 Sound power, dba 84 84 84 84 85 85 85 85 85 85 85 Sound pressure, dba 52 52 52 52 53 53 53 53 53 53 53 Length, m 2,52 2,52 2,52 2,52 2,52 2,52 2,52 2,52 2,52 2,52 2,52 Width, m 1,21 1,21 1,21 1,21 1,21 1,21 1,21 1,21 1,21 1,21 1,21 Hight, m 2,30 2,30 2,30 2,30 2,30 2,30 2,30 2,30 2,30 2,30 2,30 Weight, kg 860 870 880 900 980 1050 1090 1000 1200 1250 1300 AirGREEN PB 0500.1 0600.2 0700.2 0800.2 1000.2 Aircooled chillers capacities. User water 12/7 C, air 35 C Cooling capacity, kw 117,0 129,0 171,0 191,2 234,0 Power input, kw 37,6 39,5 54,4 62,2 75,2 EER 3,11 3,26 3,14 3,07 3,11 Number of compressors 1 2 2 2 2 Number of circuits 1 2 2 2 2 Sound power, dba 86 86 86 86 88 Sound pressure, dba 54 54 54 54 56 Length, m 2,72 2,72 2,72 2,72 3,93 Width, m 2,22 2,22 2,22 2,22 2,22 Hight, m 2,30 2,30 2,30 2,30 2,30 Weight, kg 2050 2100 2350 2400 2650

Air-to-water units PF AirGREEN PF 0120.1 0150.1 0200.1 0250.1 0300.1 0240.2 0350.1 0300.2 0400.1 0400.2 0500.1 Aircooled chillers capacities. User water 12/7 C, air 35 C Cooling capacity, kw 29,7 35,6 40,2 49,4 59,8 59,3 71,1 71,2 83,7 80,4 95,7 Power input, kw 10,1 12,1 13,6 16,6 18,1 20,6 23,8 24,6 28,4 27,5 34,0 EER 2,94 2,95 2,97 2,98 3,31 2,88 2,99 2,90 2,94 2,92 2,81 Number of compressors 1 1 1 1 1 2 1 2 1 2 1 Number of circuits 1 1 1 1 1 2 1 2 1 2 1 Sound power, dba 84 84 84 84 84 85 85 85 85 85 85 Sound pressure, dba 52 52 52 52 52 53 53 53 53 53 53 Length, m 2,52 2,52 2,52 2,52 2,52 2,52 2,52 2,52 2,52 2,52 2,52 Width, m 1,21 1,21 1,21 1,21 1,21 1,21 1,21 1,21 1,21 1,21 1,21 Hight, m 2,30 2,30 2,30 2,30 2,30 2,30 2,30 2,30 2,30 2,30 2,30 Weight, kg 840 850 860 880 960 1030 1140 950 1160 1180 1200 AirGREEN PF 0500.2 0600.1 0600.2 0700.1 0700.2 0800.1 0800.2 1000.2 1200.2 1400.2 1600.2 Aircooled chillers capacities. User water 12/7 C, air 35 C Cooling capacity, kw 98,9 118,7 119,6 137,7 144,2 142,2 167,3 191,4 237,4 275,4 288,5 Power input, kw 33,6 44,3 36,6 52,1 54,7 48,3 57,6 68,9 89,7 105,5 110,5 EER 2,94 2,68 3,27 2,64 2,64 2,94 2,90 2,78 2,65 2,61 2,61 Number of compressors 2 1 2 1 2 1 2 2 2 2 2 Number of circuits 2 1 2 1 2 1 2 2 2 2 2 Sound power, dba 85 86 85 86 86 86 86 86 88 88 88 Sound pressure, dba 53 54 53 54 54 54 54 54 56 56 56 Length, m 2,52 2,72 2,72 2,72 2,72 2,72 2,72 2,72 3,93 3,93 3,93 Width, m 1,21 2,22 2,22 2,22 2,22 2,22 2,22 2,22 2,22 2,22 2,22 Hight, m 2,30 2,30 2,30 2,30 2,30 2,30 2,30 2,30 2,30 2,30 2,30 Weight, kg 1250 1950 1980 2050 2100 2350 2400 2450 2650 2700 2800

Water-to-water units PB // Reciprocating product line WaterGREEN PB 0120.1 0150.1 0200.1 0250.1 0300.1 0240.2 0300.2 0350.1 0400.2 0400.1 0500.2 Watercooled chillers capacities. User water 12/7 C, condenser water 30/35 C Cooling capacity, kw 36,2 40,2 47,0 61,8 71,3 72,4 80,4 92,4 94,0 104,1 123,6 Power input, kw 7,6 8,7 10,2 13,5 15,5 15,1 17,4 20,2 20,4 23,6 26,9 EER 4,79 4,62 4,60 4,59 4,61 4,79 4,62 4,57 4,60 4,41 4,59 Water-to-water heatpump. User water 40/45 C, source brine 5/0 C Cooling capacity, kw 33,8 37,9 44,4 58,4 67,3 67,7 75,9 87,4 88,8 99,4 116,8 Power input, kw 8,3 9,5 11,2 14,7 16,9 16,5 19,1 22,1 22,4 25,8 29,5 EER 4,09 3,98 3,97 3,96 3,98 4,09 3,98 3,95 3,97 3,85 3,96 Number of compressors 1 1 1 1 1 2 2 1 2 1 2 Number of circuits 1 1 1 1 1 2 2 1 2 1 2 Sound power, dba 82 82 82 82 83 83 83 83 83 83 83 Sound pressure, dba 50 50 50 50 51 51 51 51 51 51 51 Length, m 1,50 1,50 1,50 1,50 1,50 2,00 2,00 1,50 2,00 1,50 2,00 Width, m 0,88 0,88 0,88 0,88 0,88 0,88 0,88 0,88 0,88 0,88 0,88 Hight, m 1,88 1,88 1,88 1,88 1,88 1,88 1,88 1,88 1,88 1,88 1,88 Weight, kg 850 860 870 890 970 1040 1080 990 1190 1240 1290 WaterGREEN PB 0500.1 0600.2 0700.2 0800.2 1000.2 Watercooled chillers capacities. User water 12/7 C, condenser water 30/35 C Cooling capacity, kw 125,3 142,6 184,8 208,2 250,6 Power input, kw 28,2 30,9 40,4 47,2 56,4 EER 4,44 4,61 4,57 4,41 4,44 Water-to-water heatpump. User water 40/45 C, source brine 5/0 C Cooling capacity, kw 119,4 134,6 174,8 198,8 238,8 Power input, kw 30,9 33,8 44,2 51,7 61,7 EER 3,87 3,98 3,95 3,85 3,87 Number of compressors 1 2 2 2 2 Number of circuits 1 2 2 2 2 Sound power, dba 84 84 84 84 86 Sound pressure, dba 52 52 52 52 54 Length, m 1,50 2,00 2,00 2,00 2,00 Width, m 0,88 0,88 0,88 0,88 0,88 Hight, m 1,88 1,88 1,88 1,88 1,88 Weight, kg 2040 2090 2340 2390 2640

Water-to-water units PF WaterGREEN PF 0120.1 0150.1 0200.1 0250.1 0300.1 0240.2 0350.1 0300.2 0400.1 0400.2 0500.1 Watercooled chillers capacities. User water 12/7 C, condenser water 30/35 C Cooling capacity, kw 32,3 39,2 45,1 56,5 64,6 64,6 76,0 78,3 90,6 90,2 106,4 Power input, kw 7,5 9,1 10,5 12,7 14,5 15,0 18,0 18,3 21,4 20,9 25,8 EER 4,31 4,29 4,32 4,44 4,47 4,31 4,22 4,29 4,23 4,32 4,13 Water-to-water heatpump. User water 40/45 C, source brine 5/0 C Heating capacity, kw 30,4 36,9 42,4 52,7 60,2 60,8 71,9 73,8 85,7 84,8 101,2 Power input, kw 7,8 9,5 10,8 13,2 15,0 15,5 18,7 18,9 22,2 21,7 26,7 COP 3,91 3,90 3,92 4,00 4,02 3,91 3,85 3,90 3,86 3,92 3,79 Number of compressors 1 1 1 1 1 2 1 2 1 2 1 Number of circuits 1 1 1 1 1 2 1 2 1 2 1 Sound power, dba 82 82 82 82 82 83 83 83 83 83 83 Sound pressure, dba 50 50 50 50 50 51 51 51 51 51 51 Length, m 1,50 1,50 1,50 1,50 1,50 2,00 1,50 2,00 1,50 2,00 1,50 Width, m 0,88 0,88 0,88 0,88 0,88 0,88 0,88 0,88 0,88 0,88 0,88 Hight, m 1,88 1,88 1,88 1,88 1,88 1,88 1,88 1,88 1,88 1,88 1,88 Weight, kg 830 840 850 870 950 1020 1130 940 1150 1170 1190 WaterGREEN PF 0500.2 0600.1 0600.2 0700.1 0700.2 0800.1 0800.2 1000.2 1200.2 1400.2 1600.2 Watercooled chillers capacities. User water 12/7 C, condenser water 30/35 C Cooling capacity, kw 112,9 126,5 129,2 136,9 152,0 155,6 181,3 212,8 252,9 273,8 311,2 Power input, kw 25,4 34,4 28,9 37,9 36,0 44,4 42,9 51,5 68,7 75,8 88,8 EER 4,44 3,68 4,47 3,61 4,22 3,50 4,23 4,13 3,68 3,61 3,50 Water-to-water heatpump. User water 40/45 C, source brine 5/0 C Heating capacity, kw 105,4 124,2 120,4 135,2 143,8 155,0 171,4 202,4 248,4 270,3 310,0 Power input, kw 26,3 35,6 29,9 39,3 37,3 46,0 44,4 53,4 71,2 78,6 92,0 COP 4,00 3,49 4,02 3,44 3,85 3,37 3,86 3,79 3,49 3,44 3,37 Number of compressors 2 1 2 1 2 1 2 2 2 2 2 Number of circuits 2 1 2 1 2 1 2 2 2 2 2 Sound power, dba 83 84 83 84 84 84 84 84 86 86 86 Sound pressure, dba 51 52 51 52 52 52 52 52 54 54 54 Length, m 2,00 1,50 2,00 1,50 2,00 1,50 2,00 2,00 2,15 2,15 2,15 Width, m 0,88 0,88 0,88 0,88 0,88 0,88 0,88 0,88 0,88 0,88 0,88 Hight, m 1,88 1,88 1,88 1,88 1,88 1,88 1,88 1,88 1,88 1,88 1,88 Weight, kg 1240 1940 1970 2040 2090 2340 2390 2440 2640 2690 2790

Felzer SIA Brivibas gatve, 201 Riga, Latvia, LV-1039 tel: +371 6788 2102 mail@felzer.lv www.felzer.lv Felzer is continuously improving its products. We therefore reserve the right to change the design and specifications without prior notification. Rights reserved. Felzer and the Felzer logo are registered trademarks of Felzer SIA. All trademarks to which reference is made herein are the property of their owners. Felzer SIA 2017. Printed in Latvia