Off-Cycle Condensate Drainage Behavior of Compact Heat Exchangers: Assessment and Enhancement

Similar documents
Assessing the Condensate-Drainage Behavior of Dehumidifying Heat Exchangers

The Effects of Hydrophilicity on Water Drainage and Condensate Retention on Air-Conditioning Evaporators

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Effect of Inclination Angle on the Air-Side Performance of Aluminum Parallel Flow Heat Exchangers Under Wet Conditions

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Purdue e-pubs. Purdue University

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Open-Cell Metal Foams for Use in Dehumidifying Heat Exchangers

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Efficiency of Non-Azeotropic Refrigerant Cycle

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

Energy Transfer Based Test Method Development and Evaluation of Horizontal Air Flow Re- Circulatory Air Curtain Efficiencies

2.2. General view of Microchannel Heat Exchangers

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

Evaluation The Effect Of Washing On The Heat Transfer Capacity And Air-Side Flow Resistance Of Air Cooled Condensers

Mini Vapour Cycle System For High Density Electronic Cooling Applications

Effects of Oil on atranscritical Carbon Dioxide Air Conditioning Systems some experiences -

Experimental and Numerical Study on the Performance of R410A Liquid Recirculation Cycles with and without Ejectors

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

Compression of Fins pipe and simple Heat pipe Using CFD

Effect of the Use Pattern on Performance of Heat Pump Water Heater

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Performance of CO2 Cycles with a Two-Stage Compressor

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Simultaneous Heat and Mass Transfer in a Wetted Heat Exchanger, Part I: Experiments

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Dae-Hyun Jin. 8/2018-Present Assistant Professor of Mechanical Engineering, Taylor University, USA

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Design Optimization of Variable Geometry Microchannel Heat Exchangers

Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

Perspectives of Aluminum As A Construction Material for Stationary Refrigeration and Air Conditioning Systems

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Effect of Heat Exchanger Configuration on the Performance of Joule-Thomson Refrigerators

Compressor Capacity Control

Low GWP Refrigerants for Air Conditioning Applications

Numerical Simulation of a New Cooling System for Commercial Aircrafts

Air-Cooled Heat Exchanger Performance for R410A

Global Journal of Engineering Science and Research Management

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Development of Performance Test Facility of Positive Displacement CO2 Refrigerant Compressor

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube

Heat sinks for electronic cooling applications

Extremely Low Refrigerant Charge Beverage Display Cooler Technology Using Propane

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Real Time Upright Freezer Evaporator Performance Under Frosted Conditions

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

Enhancement of Heat Exchanger Performance by the Extended Surfaces-Fins

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

Low Global Warming Refrigerants For Commercial Refrigeration Systems

2. HEAT EXCHANGERS MESA

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Evaluation of Mechanical Dehumidification Concepts (Part 2)

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Optimizing Chemistry and Coater Settings for Faster Drying

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

Heat Transfer of R-22 and Alternatives in a Plate- Type Evaporator

Exercise 2-4. Heat Exchangers (Optional Exercise) EXERCISE OBJECTIVE DISCUSSION OUTLINE. Description of a brazed plate heat exchanger DISCUSSION

Experimental Study on the Thermal Behavior of a Domestic Refrigeration Compressor during Transient Operation in a Small Capacity Cooling System

Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array

FLIGHT UNLOADING IN ROTARY SUGAR DRYERS. P.F. BRITTON, P.A. SCHNEIDER and M.E. SHEEHAN. James Cook University

A2L Refrigerants Leaks and Ignitions Testing under Whole Room Scale

EXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

International Journal of Advance Research in Engineering, Science & Technology SOLAR HUMIDIFIER

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Off-Cycle Condensate Drainage Behavior of Compact Heat Exchangers: Assessment and Enhancement Aridom Joardar University of Illinois at Urbana-Champaign Zhongping Gu University of Illinois at Urbana-Champaign Anthony M. Jacobi University of Illinois at Urbana-Champaign Follow this and additional works at: http://docs.lib.purdue.edu/iracc Joardar, Aridom; Gu, Zhongping; and Jacobi, Anthony M., "Off-Cycle Condensate Drainage Behavior of Compact Heat Exchangers: Assessment and Enhancement" (2006). International Refrigeration and Air Conditioning Conference. Paper 846. http://docs.lib.purdue.edu/iracc/846 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

R029, Page 1 OFF-CYCLE CONDENSATE DRAINAGE BEHAVIOR OF COMPACT HEAT EXCHANGERS: ASSESSMENT AND ENHANCEMENT Arindom. Joardar 1, Zhongping Gu 2 and Anthony. M. Jacobi 2, * 1 Graduate Research Assistant; 2 Visiting Scholar, 3, *Professor, Author for correspondence Department of Mechanical and Industrial Engineering, University of Illinois at Urbana-Champaign, 158 Mechanical Engineering Bldg, MC-244 1206 West Green Street Urbana, IL, 61802, USA Tele: (2170 649-3162 Fax: (217) 244-6534 E-mail: a-jacobi@ uiuc.edu ABSTRACT In many HVAC&R applications, fast and efficient drainage of either retained condensate or melted water after a defrosting cycle is highly desirable. Applications where off-cycle drainage is important, the so-called dynamic dip test has been demonstrated (Zhong et al., 2005) to be a fast and efficient method for comparative and screening studies. In this work, refrigeration evaporators and air-conditioning condensers were dip-tested to study the effect of heat exchanger orientation, surface coating (hydrophilic and hydrophobic) and fin-surface enhancement (louver vs. lanced) on condensate drainage and retention. From the experiments it is found that surface tension effects in interfin and louver gaps play a key role in the retention of condensate in high-fin-density compact heat exchangers. Experiments were also conducted to seek passive methods to counter surface-tension effects for drainage enhancement. Results with so called Drainage Enhancing Strips (DES) in conjunction with hot-water soaking were found to be very effective in reducing water retention. 1. INTRODUCTION In the recent past, the issue of condensate retention and drainage has gained significant importance in many HAVAC&R applications, including air-conditioning, automotive cooling, refrigeration and heat pump systems which often employ high fin density heat exchangers. For example, in refrigeration applications, retained melted water post defrosting re-freezes on fin surfaces, causing degradation in thermal-hydraulic performance and necessitating more frequent defrost cycles. Fast and efficient drainage is also important in air-conditioning heat exchangers operating under dehumidifying conditions. Retained condensate not only affects the thermal-hydraulic performance of heat exchangers used in such applications, but it also has adverse effects on the quality of conditioned air. It has been observed that the amount of condensate retained on the air-side surface significantly increases with increased fin density. Hence strategies for enhancing the condensate drainage, especially the drainage under off-cycle conditions also gain importance. Conventional wind tunnel tests to assess the retention performance are expensive, both in terms of time and equipment costs. The so called dynamic dip-testing is an attractive approach for drainage specific studies. While there has been some research on condensate retention and its thermal-hydraulic effects under steadystate conditions, there is very little work available in the open literature addressing condensate drainage in off cycle operation. 1.1 Literature Review In 1999, Osada and co-workers performed heat transfer and visualization experiments on single fin columns of flat tube evaporators. They investigated the effects of surface wettability, louver geometry, and inclination angle on condensate drainage. They concluded that fin geometry near the exit face of the heat exchanger is important, due to the accumulation of water which is driven to the exit face by the air flow and must drain through louver slits or down the face of the heat exchanger. The louver length was also found to influence drainage behaviour increasing the distance from the tube to beginning of louver cut can increase condensate retention effects. Mclaughlin and Webb (2000) studied the impact of fin geometry on drainage using a table-top test cell for experiments with singlefin column. Their results suggest louver pitch to be the single most important parameter determining drainage

R029, Page 2 characteristics of louvered fin evaporators. They state that a critical louver pitch between 1.1 and 1.3 exists for a louver angle of 30 o at which condensate retention increased by 26%. Kaiser et al., (2003) studied the condensate drainage behavior in automotive heat exchangers. They compared the dip test method to real-time retention results obtained from wind tunnel experiments. The heat exchangers retaining the most and least condensate in a steadystate wind tunnel experiment, likewise held the most and least in a dip test. They concluded that dynamic dip testing could be powerful tool for assessing the condensate retention behaviour of heat exchangers. Zhong and Jacobi (2003) presented an improved experimental technique for dynamic dip-testing and a preliminary model to predict off-cycle drainage behaviour. They found that gravity dominates drainage in the round-tube geometry, but viscous effects become important in the flat-tube heat exchangers. Joardar et al. (2004) presented dip-test data for more than 30 automotive-type heat exchangers and investigated the influence of the effect of increased fin density, surface coating, heat exchanger geometry at drainage exit region and fin corrugation shape on water retention for flat tube exchangers. They found that rectangular serpentine louver fin held dramatically less (52%) water as compared to the triangular serpentine fin design. Zhong et al. (2005) developed a mathematical model based on gravity, surface tension and viscosity effects to predict the drainage behavior of round-tube-and-fin heat exchangers and the results compared favorably with experiments. 1.2 Objectives The research presented now provides new experimental results characterizing the off-cycle drainage behaviour of compact heat exchangers for refrigeration and air-conditioning systems. The effect of fin design, heat exchanger orientation and inclination and surface coating on drainage performance is studied. A passive method for enhancing drainage from compact automotive-type louvered-fin heat exchangers is investigated. 2. EXPERIMENTAL APPARATUS AND PROCEDURE A schematic diagram of the dynamic dip-test apparatus is shown in Figure 1. The setup consisted of a large water reservoir, a smaller submerged air tank to control the water level using pressurized air, and a supporting structure for mounting and weighing the heat exchanger. The volume of the large reservoir was about 1 m 3 and the smaller displacement tank was 0.4 m 3. A pipe of 50mm diameter was used as an air passage. The heat exchanger was suspended from an electronic balance using a fixed acrylic frame and simple mounting hardware. The mounting arrangement depended on the particular orientation to be tested. For testing in vertical orientation, heavy wire was looped under the top tank or manifold and interlocked with the frame to provide a stable rigid support that did not interfere with drainage. In the case of testing in an inclined orientation, a special mounting bracket was used to provide rigid, nonintrusive support for the specimen. A computer-based data acquisition system with a recording interval of 1 second was used for monitoring and recording data. The system was comprised of a Sartorius precision balance with a built in serial RS232 port and a personal computer. Winwedge TM software was used for data recording in a text file. The balance was calibrated to an accuracy of ±0.1 grams. The procedure involves immersing PRESSURIZED AIR LINE IBM Compatible ELECTRONIC SCALE AIR VENT Tape drive WATER AIR PUMP HEAT EXCHANGER WATER Figure 1: Schematic diagram of dip-test apparatus.

R029, Page 3 the specimen in a tank of water, dropping the water level quickly, and measuring the mass of retained water as a function of time. The mass retained after 15 minutes was deemed as steady-state retention. This parameter was used to characterize drainage performance and assess drainage enhancing methods. More detail on the experimental conditions and procedures can be found in the literature (Zhong et al., 2005). 3. DYNAMIC DIP TESTING RESULTS In this section results from dip testing will be presented for all the heat exchangers used in this research. Multiple experiments were conducted, starting with dry and wet surfaces to assess the repeatability of the data. In general, for the same specimen the experimental results were found to be highly repeatable. A geometrical description of various test specimens is given in Table 1. The various specimens will be referred to by their numbers as appearing in the table. Table 1 Specimen geometrical data Specimen External Dimensions (mm) (H x W x D) Fin Type Fin Dimensions Height (mm) Fin Pitch (mm) Tube Type Tube Dimensions (mm) Width or Vertical Spacing Depth or Horizontal Spacing Tube Nos. #1 203 x 310 x 25.4 Plain 12.5 3.63 Flat 21 1.844 25.4 #2 203 x 310 x 25.4 Plain 12.5 2.12 Flat 21 1.885 25.4 #3 304.8 x 304.8 x 14.3 Louver NA 1.155 Round 12 25.4 14.3 #4 304.8 x 304.8 x 14.3 Slit NA 1.155 Round 12 25.4 14.3 #5 205 x 215 x 80 Louver 0.0889 2.31 Flat 17 2.79 80 3.1 Drainage Performance Dip-tests were performed on specimens #1 and #2 which were of identical geometry except the fin pitch. These heat exchangers were of double header construction, with a so-called flat-top wavy fin design. The heat exchangers were not symmetrical with respect to the fin orientation in their vertical direction. Hence they were dip-tested in both vertical orientations of the heat exchanger and the results are presented for up-wave and down-wave configurations (detailed later). The water retention is strongly dependent on the orientation. The meaning of the two configurations is explained diagrammatically below in Figure 2(a), where the fin cross-section along the flow depth is shown. It can be seen that the up-wave orientation of the heat exchanger has the leading and trailing edges pointing upward and thus forming two troughs for condensate retention. In contrast, the down-wave orientation forms only one trough with its both inlet and outlet edges pointing downwards. The dip-test results presented in Figure 2(b) show the effect of fin density on retention for both up- and down-wave orientations. In the down-wave configuration the retention increases with increasing fin density which is understandable, because the water is held by mid-wave troughs and their number also increases with increasing fin density. However, in the up-wave configuration it is interesting to note that both the specimens held almost same amount of water, and it appears that both drainage pattern and retention were relatively insensitive to fin density. The reason for such a behavior can be explained by noting that in up-wave configuration, due to the wavy geometry, fin spaces are filled in entirety with water for both specimens. Since both have same finned volume the retention is the same. In general, the drainage for down-wave orientation is better for obvious geometrical reasons. In order to study the effect of surface wettability on the drainage, dip-tests were performed on specimens #1 and #2 with three surface coatings, viz., hydrophobic, hydrophilic and another referred as propriety coat in this paper. The dip tests were performed at three different inclination angles of 10 o, 20 o and 30 o. Vertical tests with surface coatings yielded results identical to the uncoated specimen. A summary of retention results is presented in Table 2. The drainage characteristics for the hydrophobic surface is very different from those of the hydrophilic surface. The hydrophobic surface tends to reach a steady state quickly. The hydrophilic surface does not attain a steady state. This general behavior is however influenced by the inclination. The smaller the inclination, the more pronounced is the trend. Hydrophobic coatings consistently held more water than others.

R029, Page 4 2800 2400 2000 Vertical Down Wave, Coil 1 Up Wave, Coil 1 Down Wave, Coil 2 Up Wave, Coil 2 Mass (g) 1600 1200 1499 g 1244 g 800 896 g 400 (b) 0 0 200 400 600 800 1000 1200 1400 1600 1800 Time (Secs) Figure 2: (a) The top figure is up-wave orientation and bottom is down-wave orientation of heat exchangers 1and 2. (b) The drainage performance for specimens 1 and 2 for both orientations. 1800 1200 1600 1400 Inclination Angle - 10 o Hydrophobic, Coil #1 Hydrophilic, Coil #1 Propriety Coat, Coil #1 Hydrophobic, Coil #2 Hydrophilic, Coil #2 Propriety Coat, Coil #2 1100 1000 900 800 Inclination Angle - 20 o Hydrophobic, Coil #1 Hydrophilic, Coil #1 Propriety Coat, Coil #1 Hydrophobic, Coil #2 Hydrophilic, Coil #2 Propriety Coat, Coil #2 Mass (g) 1200 1000 Mass (g) 700 600 500 800 400 300 600 200 100 400 0 150 300 450 600 750 900 (a) Time (s) 0 0 100 200 300 400 500 600 700 800 900 (b) Time (s) 800 700 600 500 Inclination Angle - 30 o Hydrophobic, Coil #1 Hydrophilic, Coil #1 Propriety Coat, Coil #1 Hydrophobic, Coil #2 Hydrophilic, Coil #2 Propriety Coat, Coil #2 Mass (g) 400 300 200 100 0 0 150 300 450 600 750 900 (c) Time (s) Figure 3: Effect of surface coating on drainage performance of specimens 1 and 2 at different inclination angles of (a) 10 o (b) 20 o and (c) 30 o.

R029, Page 5 Table 2 Summary of results showing effect of surface coating on steady-state retention for specimens 1 and 2 Inclination Angle Hydrophobic Specimen #1 (all entries are in grams) Hydrophilic Propriety Coat Hydrophobic Specimen #2 (all entries are in grams) Hydrophilic Propriety Coat 10 o 776.6 585.1 831.5 1136.7 1009.3 617.2 20 o 293.3 209.0 344.8 655.0 415.6 327.7 30 o 193.0 160.1 183.0 435.3 345.9 234.8 Dip-tests were performed on two heat exchangers of louvered and slit-fin designs in two configurations of single slab and double slab respectively. The aim of this part of the study was to investigate the effect of fin surface enhancement on the dynamic drainage behavior. All specimens were of same fin density. A summary of retained mass of water during dip-testing is presented in Table 3. The drainage characteristics for the surfaces were approximately of flat type i.e., the retained mass tends to reach a steady state quickly and the drainage curve is flat in shape. The slit fin design consistently held more water than the louvered type. It is interesting to note that the due to high fin density, surface tension forces dominate compete with gravity in the drainage process. Hence the vertical and inclined positions held almost same amount of water. Table 3 Drainage performance for specimens 3 and 4: Louver vs. Slit fin Inclination Angle Specimen #3 (all entries in grams) Double Single Slab Slab Specimen #4 (all entries in grams) Double Single Slab Slab Vertical 43.7 82.9 50.4 97.0 25 o 42.6 78.0 47.6 91.9 3.2 Drainage Enhancing Strips (DES) For highly compact heat exchangers, surface tension causes form bridges to form between inter-fin and inter-louver gaps, impeding drainage. An important distinction in these exchangers is whether they are a single-header or a double-header construction, with a header at the top, or one at the top and one at the bottom, respectively. The single-header construction generally employs strips or plates at tube ends, shrouding the fins to protect them and provide structural support. The end-plates could block the passage of condensate and cause increased retention. In order to investigate such a possibility, dip-testing experiments were conducted on specimen 5 with and without these shrouds. A 15% reduction in retained water was observed without the bottom plates. It then was logical to seek methods which could help reduce surface tension effects in this region, where water tends to accumulate. On the conjecture that if the air-water interface is broken at the bottom of the heat exchanger, then drainage could be promoted, a preliminary quantitative assessment of the concept was undertaken. A plain aluminium strip, as shown in Figure 4, was designed to be placed in contact with the bottom louvers of each fin. The drainage enhancement strips (DES) were mounted on the bottom of the heat exchanger with a simple fixture for holding them in place while their blades made contact with the fin louvers. The standard dip test was performed and the results indicated a 14% improvement in drainage behaviour as compared to the baseline heat exchanger. This preliminary result was very encouraging; however, this first design and the fixing arrangement were not satisfactory. Due to unevenness of the fins and lack of flexibility in the fixture, the DES were not in contact with all louvers. Further refinement was achieved by accurately measuring the fin depth with respect to the tubes and preparing tailor-made DES for each fin using copper strips. The array of DES was accurately held in position and brazed together with two guiding copper strips on either side as shown in Figure 5. This procedure ensured excellent contact of DES with louvers. However, the dip-test results yielded only 7% improvement with respect to baseline. This figure is about half that obtained

R029, Page 6 using aluminium DES. Copper is prone to contamination by organics and is then less wettable than aluminium, and wettability was then explored for its impact on DES performance. Louvers Drainage Enhancing Strip Figure 4: The first figure shows an simple DES with a pilot hole for fastening purposes. The second schematic shows DES blade in line-contact with louvers. The contact angle is useful tool for characterizing the wettability of a surface, and it generally expected that copper will manifest a higher contact angle than aluminum. It is expected that the wettability of the DES is important in its function of breaking the air-water interface as the bottom of the heat exchanger. In order to quantitatively evaluate the impact of surface wettability on DES performance, the copper and aluminium DES were subjected to hot-water treatment. A recent study of Min et al. (2002) demonstrated that a cyclic hot water soak is an effective means to reduce the contact angle and improve the wettability of copper and aluminium surfaces. The procedure involved subjecting the DES specimens to wet/dry cycling consisting of alternately immersing the samples into distilled hot water for 5 minutes followed by air drying with a fan for 25 minutes. The hot water was maintained at temperature of 98 o C to 100 o C and drying air was at ambient conditions. This cycle was repeated for 6 hours for each DES. Figure 5: (a) Tailor-made copper DES for each fin row brazed together with two holding strips on either side. (b) Entire DES assembly mounted on the heat exchanger. The treated copper DES reduced retention by 11.2% as compared to 7% when used without treatment. The treated aluminium DES reduced retention by 16.4% as compared to 14% achieved with untreated aluminium DES. Further efforts to refine DES design were directed towards improving the contact between the DES and the louvered fin. The refinement culminated in an introduction of a saw-tooth profile on the contact blade of the DES. The sawtooth pitch was so maintained so that it matched up with the corresponding louver pitch as shown schematically in Figure 6(b). The treated saw toothed aluminium DES improved the drainage performance by 19.6% as compared to the plain treated performance of 16.4%.

R029, Page 7 Figure 6: (a) The aluminium saw tooth DES designed for enhanced contact with louver. (b) The schematic showing saw tooth of DES meshed with louver spaces. The saw tooth pitch was of the same magnitude as the louver pitch Figure 7: Picture shows the saw toothed DES mounted on the heat exchanger. Finally, treatment of the entire heat exchanger was carried out for 6 hours in an attempt to improve the surface wettability. After treatment the specimen was subjected to dip testing with treated aluminium saw tooth DES. The result improved by only 0.4%. This outcome is not too surprising, the specimens undergo a surface treatment during manufacturing, and they may not be amenable to further treatment in such a simplified way. A chart summarizing the results obtained by implementing DES on a bottom of the heat exchanger is provided in Figure 8. 110.0% 100.0% 90.0% 80.0% The comparison of condensate drainage behaviors 100.0% 92.9% 88.8% 86.0%83.4% 80.4% 80.0% Without DES Copper DES Treatment Copper DES Aluminum DES Treatment Aluminum DES Treatment Aluminum DES (Saw) Treatment Heat Exchanger 70.0% 60.0% Figure 8: Bar chart showing the impact of DES and Bhoemite treatment on drainage performance.

R029, Page 8 4. CONCLUSIONS In this work, dynamic dip-testing was performed on compact heat exchangers for refrigeration and air-conditioning systems. The effects of heat exchanger orientation, inclination with respect to vertical, surface wettability and fin surface design were experimentally explored. An attempt to enhance the drainage performance of a single-header compact heat exchanger using so called DES in conjunction with surface treatment was undertaken. Some major conclusions are: For the flat-top wavy fin design, water retention is strongly dependent on the orientation of the heat exchanger. In the absence of any other passage for drainage, inclination augments drainage and reduces steady-state retention. Heat exchangers with hydrophilic surface coatings consistently held less water compared to the hydrophobic surfaces, suggesting that hydrophilic surfaces are more conducive for efficient drainage. This result remained valid at for both vertical and the three inclined conditions (10 o, 20 o, 30 o ) of the heat exchangers. Louvered-fin surfaces retained less water compared to the slit-fin surfaces for the round tube heat exchangers. For these high-fin-density specimens, the impact of inclination on drainage was found to be insignificant, suggesting that surface tension forces compete with gravity in the drainage process. For the single header specimen #5, about a 15% improvement in drainage could be effected by cutting out the bottom plates. However, it is impossible to isolate this performance improvement to removing the bottom plates; it might be related to other geometry changes (damaged fins). Using new approach, called drainage enhancing strips (DES) to break surface tension, and surface treatment, roughly a 20% improvement is achieved in the drainage performance of an automotive-type louvered-fin heat exchanger. REFERENCES Joardar, A., Gu, Z. and Jacobi, A.M., 2004, Assessing the condensate-drainage behaviour of dehumidifying heat exchangers, Proc. International Refrigeration and Air conditioning Conference at Purdue, paper R087, July 10-15. Kaiser, J., Y. Zhong, A. M. Jacobi, C. Zhang and H. Hu, 2003, Condensate Retention and Dynamic Drainage from the Air-Side Surface of Automotive-Style Heat Exchanger, Proc.Int. Conf. Compact Heat Exchangers and Enhancement Tech. for the Process Industries 2003, p. 361-366. McLaughlin, W.J. and Webb, R.L., 2000, Condensate Drainage and Retention in Louver Fin Automotive Evaporator, Proc. SAE Int. Cong., Detroit, MI: SAE paper 00HX-34. Min, J. and R. L. Webb, 2002, Long-Term Wetting and Corrosion Characteristics of Hot Water Treated Aluminum and Copper Fin Stocks, Int. J. Refrig., vol. 25: p. 1054-1061. Osada, H., Aoki, H., Ohara, T. and Kuroyanagi, I., 1999, Experimental Analysis for Enhancing Automotive Evaporator Fin Performance, Proc. Int. Conf. Compact Heat Exchangers and Enhancement Tech. for the Process Industries-1999, p. 439-445. Zhong, Y. and Jacobi., A.M., 2003, Dynamic Dip-Testing to Assess the Condensate-Drainage Behaviour of De- Humidifying Heat Exchangers. Proc. 2 nd Int. Conf. on Heat Trans., Fluid Mech. and Thermodynamics, vol. 1, p. 560-567. Zhong, Y., Joardar, A., Gu, Z., Park, Y.G., and Jacobi, A.M, 2005, Dynamic Dip Testing as a method to assess the condensate drainage behavior from the air-side surface of compact heat exchangers, Experimental Thermal Fluid Science 29, p. 957 970. ACKNOWLEDGEMENT The authors thank Juergen Voss and Mike Heidenreich of Advanced Heat Transfer, LLC, USA and Chao Zhang of Visteon Inc., for their financial support of this work and for many animated conference calls, in which their technical expertise and sense of humor were invaluable.