Operating Manual MSF220V(VU)

Similar documents
Operating Manual MS220KA and MSR220KA

Operating Manual TR600

Operating Manual MS220DA

Operating Manual MS220Vi and MSR220Vi

Operating Manual MS220VA and MSR220VA

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

1.7. Insulation fault evaluators EDS460/490 EDS461/491

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

1.7. Insulation fault evaluators EDS460/490 EDS461/491

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

Insulation fault evaluator EDS460-DG

DTA. Motor thermistor relay. Benefits. Description

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

DTA04. Motor thermistor relay. Benefits. Description

SCHMIDT LED Measured Value Display MD Instructions for Use

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating Manual RCM420

User Manual 120/240/300 Outdoor Motion Detector

Monitoring Relays. 3RN1 Thermistor Motor Protection. For PTC sensors. 7/120 Siemens LV 1 T 2008

Monitoring Devices 11/1

CMD420 / CMD421 Series

Key-Operated Switch GMA 41 / GMA 44 SW. Operation Manual

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

ACS-30-EU-EMDR- 10-MOD

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Operating Manual VMD420

5, SE GÅNGHESTER,

Overload Relay EMT6 Overload monitoring system for machines operating in the EEx e area

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

QFM21... Duct sensors. Symaro. for relative humidity and temperature

RCMA423. Residual current monitor for monitoring AC-, DC- and pulsed DC currents in TN- and TT systems Software-Version: D330 V1.0x.

Interface and EOL Modules 8

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

Line Isolation Monitor (LIM) LIM2000plus

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

PROTECT SRB 200EXi-1A

Remote alarm indicator and test combination MK2430

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Retroreflective sensor with polarization filter

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Ordering Key. Dielectric strength

Wind Alarm Instrument x.x0x

Temperature-Relay TR210

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Thermal Management Products & Accessories for Enclosures

Universal-Relay TR 800 Web

Retro-reflective Sensing range: 0mm to 2000mm

PHOTOELECTRIC AMPLIFIER SERIES

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

RE-PR3-E-27 3-Phase Panel Mount 27kW

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

ISIS SAFETY SYSTEM Installation guide

Multi-Gas-Controller MGC2

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Emotron M10 Shaft Power Monitor. Instruction manual English

RCMA423-DM1C Residual current monitor

Instruction VIBROCONTROL 850. Single channel vibration monitor. Keep it accessible for future reference.

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

InductIve SenSorS 2018

PolyGard 2-channel Gas Controller MGC-03

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

BES M30EP-PFC12F-S04G-D12 BES Q40ZU-PFC15B-S04G-D12 BES Q40ZU-PFC20F-S04G-D12 Inductive Safety Sensors User's Manual

Installation / Monitoring Technique

LC3000 Level Controller Installation and Maintenance Instructions

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Operating Instructions. For. Alarm Control Module. Model SSR 500

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

FlowJam Bulk Flow Detection

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Manual CME420. Multi-functional current relay, AC, overcurrent/undercurrent/ window discriminator function CME420_D00034_02_M_XXEN/05.

LINETRAXX RCMS460-D/-L RCMS490-D/-L

Lyovapor L-300 Technical data sheet

General Specifications

Process Alarm Module RTA 421

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Heating controller Lago

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

Transcription:

ZIEHL industrie elektronik GmbH + Co KG Daimlerstr.13, 74523 Schwäbisch Hall, Germany + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperaturrelais und MINIKA Strom- und Spannungsrelais Messgeräte MINIPAN Schaltrelais und Steuerungen Messumformer Netz- und Anlagenschutz Operating Manual MSF220V(VU) updated: 2016-10-13/Fu/sm - PTC-resistor relay MSF220V(VU) 11720-0702-01 Page 1 / 8 www.ziehl.de

Table of contents 1 Application and short description... 2 2 Overview of functions and connection plan... 2 3 Connection Plan... 3 3.1 Application with fan:... 3 3.2 Application without fan:... 3 4 Detailed description... 4 5 Assembly... 5 6 Putting into operation... 5 7 Trouble shooting... 6 8 Technical data... 7 9 Form V4... 8 1 Application and short description The MSF220V is particularly suitable for the temperature monitoring at dry transformers. 3 PTC-circuits with different nominal response temperatures (NRT) can be connected to this unit, one for controlling a fan (forced cooling) and two for alarms. Each PTC-circuit is monitored for break and short circuit. This reduces the probability of false alarms. Approvals: UL Recognized Component 2 Overview of functions and connection plan 3 PTC-circuits MSF220VU for universal supply voltage AC/DC 24-240 V intelligent control of fan (relay K0, 1 normally-open contact) ALARM 1 in closed-circuit current mode (relay K1, 1 change-over contact) for pre alarm. Signals also error in any sensor and interruption of supply voltage. ALARM 2 in operation current mode (relay K2, 1 changeover contact). No signal when switching on and off the supply voltage. all output relays potentially separated from each other. monitoring of sensor lines TEST-button (stop possible before ALARM 2) Simply test function, sensor monitoring can be disengaged (for 10 minutes) LEDs for ON, sensor error, Fan, ALARM 1 and ALARM 2 plug-in terminals housing for mounting on DIN-rail or wall-mount mounting height 55 mm MSF220V(VU) 11720-0702-01 Page 2 / 8 www.ziehl.de

PTC Alarm 2 PTC Alarm 1 R Alarm 2 Alarm 1 Fan/Al 1 PTC Alarm 2 PTC Alarm 1 PTC Fan Alarm 2 Alarm 1 Fan/Al 1 3 Connection Plan 3.1 Application with fan: N L1 AC: L1 N DC: L+ L- M Lüfter / Fan A1 A2 24 21 22 14 11 12 08 05 K2 T T2 T1 T0 T K1 K0 3.2 Application without fan: AC: L1 N DC: L+ L- A1 A2 24 21 22 14 11 12 08 05 K2 T T2 T1 T0 T K1 K0 MSF220V(VU) 11720-0702-01 Page 3 / 8 www.ziehl.de

4 Detailed description The PTC-relay MSF220V has been designed for monitoring the temperature of dry-transformers. 3 PTC-circuits with different nominal-response-temperatures (NRT) can be connected to this unit, one for controlling a fan (forced cooling) and two for alarms. Each PTC-circuit is monitored for break and short circuit. This reduces the probability of false alarms. Table of functions: IN OUT LED FAN / Alarm 1 Alarm 1 Alarm 2 FAN Alarm 1 Alarm 2 Sensor ON contact 05-08 11-12 21-24 Power OFF 0 1 0 0 0 0 0 0 Power ON 2 s 2 s 2 s 2 s 1 Sensor 0 normal 0 0/ 0 1 Flash* ( T / T0 ) overload 1* 1 0 1 0 / 1 Flash 1 1 Sensor 1 normal 0 0 0 1 ( T / T1 ) overload 1 1 1 1 0 1 0 / 1 Flash 1 1 Sensor 2 normal 0 0 0 1 ( T / T2 ) overload 1 1 0 1 0 / 1 0 ( 1 ) Flash 1 1 * = delayed switch back 20-60 min. ( rückschaltverzögert 20-60 min. ) LEDs Alarm 1 and Alarm 2 flash until Reset ( blinken bis zu einem Reset oder Spannungsunterbrechung ) Test: LED "ON" -flash -> +2 s -> FAN -> +3 s -> Alarm 1 -> +3s -> Alarm 2 -> +7 s -> Test 2 (0 / ) Interrupt on release ( Abbruch bei Loslassening ) MSF220V(VU) 11720-0702-01 Page 4 / 8 www.ziehl.de

5 Assembly Mount on 35 mm mounting rail EN 60715 or Wall mounting with screws M4 6 Putting into operation Connect wires as per connection plan DANGER! Hazardous voltage! Will cause death or serious injury. Turn off and lock out all power supplying this device before working on this device. When installing the device into the switch-gear cabinet, please observe the max. admissible temperature. Care for both, sufficient clearance to other devices or sources of heat or enough forced draught.! Attention! Before switching on make sure that the supply voltage Us of the type plate and the mains voltage are the same! Apply mains voltage to terminals, AC to A1 and A2 (DC A1=+, A2=-). When device is ready for operation, relays K1 picks up (contact 11-14 closes), the green LED "ON" is alight.! In case of failure of supply voltage, the monitored unit is not protected any more. The operator must ensure, that a failure is detected, e.g. by monitoring Alarm 1 (K1) or by testing the unit regularly. Even if no temperature warning is monitored with alarm 1, the function of the relay K1 has to be evaluated, otherwise the monitoring can fail unnoticed (missing supply- voltage, equipment failure etc.). When no sensor is connected to T/T1, a resistor (100Ω 1000Ω) must be mounted. MSF220V(VU) 11720-0702-01 Page 5 / 8 www.ziehl.de

7 Trouble shooting LED "ON" is not alight Make sure that supply voltage is connected correctly (+/-) to terminals A1/A2 and is the same as on the type plate LEDs FAN, ALARM 1 or ALARM 2 flash, LED SENSOR light up and relay K1 doesn t pick up: Check the PTC-sensors. Make sure they are connected correctly to T0, T1 and T2. All PTC must have a low resistance (pay attention to monitoring sensor-break and short-circuit; when using without fan a resistor 100... 1000 ohm in T/T0 is required) Testing the outputs can easily be realized by using the test-button (keep pressed). If no PTC resistors are connected, the relay K1 always signals an alarm For testing the PTC-input, the resistance has to be increased slowly, i.e. by means of a potentiometer (app. 10 kω). Rapid changes may be detected as sensor-error. During normal operation testing the function with a short circuit in the sensor-input and/or by disconnecting the sensors (interrupt) is not possible. Any manipulation will result in detecting a sensor-error (K1 releases and a sensor-error is displayed, K0 and K2 do not switch) Test with interrupt and short circuit at the sensor-inputs is possible in test function 2. Press Reset/Test-button until LED "ON" flashes rhythmically (approx. 15 s). The device will return to normal operation when pressing Set/Reset or automatically after 15 minutes. Attention! Check PTC s only with measuring voltages < 2.5 V. In case of any other malfunctions, replace device and send it in together with a description of the occurred problem. MSF220V(VU) 11720-0702-01 Page 6 / 8 www.ziehl.de

8 Technical data Type MSF220V MSF220VU Order number T 221738 T 221737 Supply voltage/frequency Us AC 220-240V 50/60 Hz AC/DC 24 240 V Power consumption P < 3 VA P < 5 VA < 2 W Tolerance voltage Us AC 0.9...1.1 Us AC/DC 20 270 V Tolerance frequency Us 48...62Hz 40 70 Hz PTC-resistor connection Cut-out point Reclosing point Collective resistance of cold sensors Short-circuit monitoring Terminal voltage (sensors) Terminal current (sensor) 3 x 1...6 PTC in series 3.3...4.0 kω, typ. 3.65 kω 1.5...1.65 kω, typ. 1.6 kω 1.5 kω R min > 40 Ω, R k = 20 40 Ω 2.5 V at 250 Ω 5 V at 4 kω 2 ma Relay output K1 and K2 = 1co potential free K0 = 1no potential free Switching voltage max. AC 415 V Switching current max. AC 6 A Switching power max. AC 2000 VA 120 W at DC 24 V Rated operational current Ie AC-15: I e = 2A, U e = 400 V I e = 3 A, U e = 250 V DC-13: I e = 2A, U e = 24 V Mechanical contact life 3 x 10 7 operations Electrical contact life 1 x 10 5 operations (at 230 V / 6 A) Factor of reduction at cos 0.3 0.5 x max. switching capacity Fuse for device and contacts 4 A, time-lag (gl) UL electrical ratings 250 V ac, 3 A, general use 240 V ac, 1/4 hp, 2.9 FLA 120 V ac, 1/10 hp, 3.0 FLA C 300 Testing conditions EN 50178 / EN 60947 Rated insulation voltage AC 300 V Pollution degree 2 Overvoltage category III Rated impulse voltage 4000 V EMC EN 61000-6-2 / EN 61000-6-3 On period 100 % max. ambient temperature -20... +60 C / -20 +70 C Housing: design V4 Material Polyamid PA66, UL 94 V-2 Mounting height / Width 55 mm / 4 TE Dimensions (H x W x D) 90 x 70 x 58 mm Protection housing/contacts IP 30 / IP 20 Tightening torque 0,5 Nm Line connection solid wire 1 x 0.5... 1.5 mm2 Stranded wire with insulated ferrules 1 x 0.14 mm2 1 mm2 Mounting snap able on 35 mm standard rail according to EN 60715 or assembly with screws M 4 Weight app. 250 g Subject to technical modifications MSF220V(VU) 11720-0702-01 Page 7 / 8 www.ziehl.de

3 61,8 45 (90) 116 98 9 Form V4 dimensions in mm 58 48 16,5 70 Option 5 4 1 2 3 6 7 1 Upper part 2 Lower part 3 Bar for snap mounting 4 Latch for sealing 5 Front panel 6 Position downward 7 Bar for fixing to wall with screws, Ø 4.2 mm MSF220V(VU) 11720-0702-01 Page 8 / 8 www.ziehl.de