Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Anti freeze heater (optional) W Expansion vessel Volume l 6 6 6

Similar documents
Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

Air Conditioning. Technical Data EEDEN RXS-F8

Air Conditioning. Technical Data EEDEN AZQS-BV1

DESIGN & TECHNICAL MANUAL

EEDEN technical data ERHQ AA

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Air Conditioning Technical Data AZAS-MY1

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

Air Conditioning. Technical Data. Low temperature hydrobox for VRV EEDEN HXY-A

WPL 23 E 55 C 35 C A ++ A + A B C D E F G A + A kw kw. 58 db. 65 db

Daikin Altherma hybrid heat pump. The natural combination

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

WPL C 35 C A ++ A + A B C D E F G A + A kw kw. 69 db

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

WPL 17 IKCS classic 55 C 35 C A ++ A ++ A ++ A + A B C D E F G kw kw. 50 db. 44 db

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

TABLE OF CONTENTS ERHQ BAV3

Heating. Technical Data EEDEN ERRQ-AY1

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ. Air cooled chiller

EEDEN technical data ERHQ AA. Altherma. Altherma

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Air Conditioners. Technical Data RZQG-L

Air Conditioners Technical Data

DESIGN & TECHNICAL MANUAL

103776HV1241 NOVELAN LAV 8-HV kw kw db 50 db

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Daikin Altherma Low Temperature monobloc heat pump

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1

Chillers. Technical Data. EWYD-BZ 250~580 kw

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

EWAD-TZB. Screw inverter chiller. High efficiency chiller for comfort and process cooling

DACA-EEDEN technical data. Engineering Data. DaikinAltherma

Air Conditioners Technical Data

where innovation meets creativity

General Outline: Altherma

SG79V571H02_print outline.pdf 2012/10/23 17:32:06 CMY

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

Daikin air conditioners for your home, shops, restaurants and offices

BH79B928H01_print_outline.pdf 2013/09/30 14:10:38 CMY

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Air Conditioners Heating & Cooling

Chillers. Technical Data. Air Cooled Chiller ECDEN10-403A EUWA*-KBZW1 EUWY*-KBZW1

TABLE OF CONTENTS ERSQ-AAY1

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

Air conditioners, heating & cooling for the retailmarket and offices

The natural fit, all-in-one. Daikin Altherma monobloc heat pump for the installer

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

All-in-one comfort for residential applications. Product catalogue Heating

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

Teknik Data NIBE F2120 8, 12, 16, 20

Air Conditioning Technical Data RZAG-MV1

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Daikin air conditioners for shops, restaurant and offices

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW

Heating. Why choose a Daikin heating system? 20. Products overview 24. Combination tables 26. Options & accessories 74

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H)

PRODUCT INFORMATION (*) Y cooling Y Warmer (if designated) N heating Y Colder (if designated)

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

Air / Water Heat Pump - Compact Design Modulating 8 18 kw

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Air Conditioners Heating & Cooling

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

The natural ombination

Air Conditioners Heating & Cooling

Air conditioners Cooling only

The natural. hoice installer leaflet. DAikin Altherma low temperature heat pump

APPLIED SYSTEMS. Water cooled centrifugal chillers 307 EWWD-FZXS 307 DWSC / DWDC 308 DWME 310

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

Water cooled VRV IV W-series

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

Commercial and Technical Data

Air Conditioning Technical Data RZASG-MV1

Air Conditioning. Technical Data. VRV IV S-series heat pump EEDEN16-200_2 RXYSQ-TV1

Prices and technical information for Applied Systems. Pricelist Applied Systems

EWAT-B. Multi scroll chiller with R-32 refrigerant. First air cooled chiller with environmental friendly R-32 refrigerant

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

Daikin leads the way:

EWWD MBYN EWLD MBYN Applied systems

PRODUCT INFORMATION (*) Y cooling Y Warmer (if designated) N heating Y Colder (if designated)

Water-cooled chillers Remote condenser chillers NEW

DRAFT ECODESIGN REGULATION FOR ENER LOT21 PRODUCTS

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Advance Split

2. HYDRAULIC UNIT. COMFORT SERIES_Single phase type: WG A050DG WG A100DG HIGH POWER SERIES: WG G140DG WGYK160DG9

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

Transcription:

EWYQ005ADVP EWYQ006ADVP EWYQ007ADVP Sound pressure level Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Hydraulic components Anti freeze heater (optional) W 75 75 75 Expansion vessel Volume l 6 6 6 Pre pressure bar 1 1 1 Safety valve bar 3 3 3 Water filter Diameter inch 1" 1" 1" Unit water volume l 5.50 (4) 5.50 (4) 5.50 (4) Operation range Air side Cooling Min. CDB 10 10 10 Max. CDB 43 43 43 Heating Max. CDB 25 25 25 Min. CDB 15 15 15 Water side Heating Min. CDB 30 30 30 Max. CDB 50 50 50 Cooling Max. CDB 20 20 20 Min. CDB 5.00 5.00 5.00 Refrigerant charge Per circuit kg 1.70 1.70 1.70 Per circuit TCO2Eq 3.55 3.55 3.55 Compressor Output W 1,920 1,920 1,920 Quantity 1 1 1 Starting method Inverter driven Inverter driven Inverter driven Compressor = Type Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Model 2YC63BXD#C 2YC63BXD#C 2YC63BXD#C Space general Air to water unit Rated airflow (outdoor) m³/h 2,820 2,820 2,820 Other Psb (Standby mode) kw 0.011 0.011 0.011 Poff (Off mode) kw 0.011 0.011 0.011 Pto (Thermostat off) kw 0.054 0.054 0.054 Pck (Crankcase heater mode) kw 0.032 0.032 0.032 Capacity control Inverter Inverter Inverter Space general = Other = Cdh degradation Integrated supplementary heater Psup kw 0.00 0.00 0.00 NOx emission mg/kwh 0.00 0.00 0.00

Type of input Electrical Electrical Electrical Weight Packed unit kg 108 108 108 Operation weight kg 104 104 104 Unit kg 100 100 100 Air heat exchanger Stages Quantity 32 32 32 Fin pitch mm 1,8 1,8 1,8 Rows Quantity 2 2 2 Type Tube type Tube type Tube type Refrigerant oil Charged volume l 0.750 0.750 0.750 Type FVC50K FVC50K FVC50K General Supplier/Manufacturer details Name and address Daikin Europe N.V. Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. Zandvoordestraat 300, 8400 Oostende, Belgium Name or trademark Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Product description description = Low temperature heat pump Supplementary heater integrated description = Air to water heat pump description = Water to water heat pump description = Brine to water heat pump Heat pump combination heater Yes Yes Yes Yes Yes Yes Yes Yes Yes no no no no no no no no no Pump Standard Power input W 130 130 130 Nominal ESP unit Cooling kpa 51.8 49.3 45.2 Heating kpa 48.9 46.4 40.6 Quantity 1 1 1 Type Water cooled Water cooled Water cooled Model YONOS PARA GT25/7.5 RKC130 YONOS PARA GT25/7.5 RKC130 YONOS PARA GT25/7.5 RKC130 LW(A) Sound power level (according to EN14825) db(a) 62.0 62.0 63.0 Refrigerant Circuits Quantity Refrigerant = Refrigerant control Inverter Inverter Inverter Refrigerant = Refrigerant type R 410A R 410A R 410A Refrigerant = Refrigerant gwp 2,087.5 2,087.5 2,087.5 Fan motor Output W 53 53 53 Cooling capacity Nom. kw 5.28 (1) 6.08 (1) 7.18 (1) Min. kw 4.09 (1) 4.09 (1) 4.09 (1) Max. kw 5.28 (1) 6.08 (1) 7.18 (1) Piping connections Water heat exchanger drain 5/16 SAE flare 5/16 SAE flare 5/16 SAE flare

Water heat exchanger Minimum water volume in the system l 10 10 10 Model Quantity 1 1 1 Type ACH30 48 ACH30 48 ACH30 48 Filter Diameter perforations mm Type Brass Y strainer Brass Y strainer Brass Y strainer Water flow rate Heating Nom. l/min 17.5 19.5 23.5 Min. l/min 12 12 12 Insulation material Polyethylene foam Polyethylene foam Polyethylene foam Type Brazed plate Brazed plate Brazed plate Power input Cooling Nom. kw 1.94 (1) 2.40 (1) 3.00 (1) Heating Nom. kw 1.65 (2), 2.02 (3) 1.89 (2), 2.29 (3) 2.41 (2), 2.88 (3) Sound power level Cooling Nom. dba 62.0 62.0 63.0 Safety devices Item 01 Fan motor thermal protection Fan motor thermal protection Fan motor thermal protection 02 Fuse Fuse Fuse 03 Safety valve Safety valve Safety valve 04 Flowswitch Flowswitch Flowswitch Dimensions Packed unit Width mm 1,265 1,265 1,265 Height mm 915 915 915 Depth mm 442 442 442 Unit Width mm 1,190 1,190 1,190 Depth mm 360 360 360 Height mm 805 805 805 Capacity control Method Inverter controlled Inverter controlled Inverter controlled Casing Colour Ivory white Ivory white Ivory white Material Polyester painted galvanised steel plate Polyester painted galvanised steel plate Polyester painted galvanised steel plate Space Average climate water outlet 35 C A Condition ( 7 CDB/ 8 CWB) PERd % 92.8 91.2 88.4 Pdh kw 4.50 5.20 6.00 Space = = A Condition ( 7 CDB/ 8 CWB) = 2.32 2.28 2.21 C Condition (7 CDB/6 CWB) Pdh kw 2.20 2.30 2.90 PERd % 178 183 190 Space = = C Condition (7 CDB/6 CWB) = Space = = C Condition (7 CDB/6 CWB) = Cdh degradation 4.44 4.58 4.74 D Condition Pdh kw 2.60 2.60 2.60

(12 CDB/11 CWB) PERd % 244 250 262 Space = = D Condition (12 CDB/11 CWB) = Space = = D Condition (12 CDB/11 CWB) = Cdh degradation 6.11 6.24 6.55 Rated heat output supplementary capacity General Psup (at Tdesign 10 C) (GCV) Ƞs (Seasonal space efficiency) Prated at 10 C kw 2.10 2.10 2.80 kwh 3,710 4,120 4,950 Gj 13.3 14.8 17.8 % 133 133 134 kw 6.10 6.80 8.20 Space = = General = Seasonal space eff class Space = = General = Scop A+ A+ A+ 3.39 3.40 3.41 B Condition (2 CDB/1 CWB) Pdh kw 3.40 3.60 4.40 PERd % 134 132 131 Space = = B Condition (2 CDB/1 CWB) = Space = = B Condition (2 CDB/1 CWB) = Cdh degradation 3.36 3.29 3.28 Tbiv (bivalent temperature) Pdh kw 4.80 5.50 6.40 PERd % 98.8 97.6 94.0 Tbiv C 5.00 5.00 5.00 Space = = Tbiv (bivalent temperature) = 2.47 2.44 2.35 Tol (temperature operating limit) PERd % 84.0 83.6 81.2 WTOL C 35.0 35.0 35.0 Pdh kw 4.00 4.70 5.50

TOL C 10.0 10.0 10.0 Space = = Tol (temperature operating limit) = 2.10 2.09 2.03 Cold climate water outlet 35 C General Space = Cold climate water outlet 35 C = General = Qhe (GCV) = Gj Gj 17.5 21.5 24.6 kwh 4,850 5,980 6,850 Ƞs (Seasonal space efficiency) % 113 109 108 Prated at 22 C kw 5.70 6.80 7.70 Warm climate water outlet 35 C General Prated at 2 C kw 6.20 7.40 8.00 Ƞs (Seasonal space efficiency) % 177 173 173 kwh 1,770 2,190 2,370 (GCV) Gj 6.37 7.89 8.52 Fan Quantity 1 1 1 Type Propeller fan Propeller fan Propeller fan Discharge direction Horizontal Horizontal Horizontal Heating capacity Nom. kw 6.02 (2), 5.57 (3) 6.72 (2), 6.27 (3) 8.18 (2), 7.67 (3) Min. kw 4.42 (2), 4.01 (3) 4.42 (2), 4.01 (3) 4.42 (2), 4.01 (3) Max. kw 7.19 (2), 6.75 (3) 8.50 (2), 8.05 (3) 9.10 (2), 8.65 (3) Water circuit Piping connections diameter inch 1" MBSP 1" MBSP 1" MBSP Template Chillers air cooled Chillers air cooled Chillers air cooled Sound condition ecodesign and label Sound power in mode, measured according to the EN12102 under conditions of the EN14825 Sound power in mode, measured according to the EN12102 under conditions of the EN14825 Sound power in mode, measured according to the EN12102 under conditions of the EN14825 Cop 3.65 (2), 2.76 (3) 3.58 (2), 2.74 (3) 3.39 (2), 2.66 (3) Eer 2.72 (1) 2.53 (1) 2.39 (1) Fans Voltage V 230 230 230 Quantity 1 1 1 Phase 1~ 1~ 1~ Power supply Voltage range Max. % 10 10 10 Min. % 10 10 10

Frequency Hz 50 50 50 Voltage V 230 230 230 Phase 1~ 1~ 1~ Unit Starting current Nom. A 11.0 11.0 11.0 Running current Max A 19.0 19.0 19.0 Unit = Minimum ssc value Equipment complying with EN/IEC 61000 3 12 Equipment complying with EN/IEC 61000 3 12 Equipment complying with EN/IEC 61000 3 12 Unit = Recommended fuses according to iec standard 269 2 20 20 20 Evaporator heater tape Capacity W 75 75 75 Voltage range Min. % 10 10 10 Max. % 10 10 10 Supply voltage V 230 230 230 Recommended fuses 25A 25A 25A Pump Standard Power input kw 0.130 0.130 0.130 Speed Max. rpm 2,450 2,450 2,450 Min. rpm 1,050 1,050 1,050 Nom. rpm 2,250 2,250 2,250 Voltage V 230 230 230 Maximum running current A 0.580 0.580 0.580 Pump Standard = Pump standard phase 1~ 1~ 1~ Notes Tamb 35 C LWE 7 C (DT=5 C) Tamb 35 C LWE 7 C (DT=5 C) Tamb 35 C LWE 7 C (DT=5 C) LWC 35 C (DT=5 C) LWC 35 C (DT=5 C) LWC 35 C (DT=5 C) LWC 45 C (Dt=5 C) LWC 45 C (Dt=5 C) LWC 45 C (Dt=5 C) Including piping + PHE; excluding expansion vessel Including piping + PHE; excluding expansion vessel Including piping + PHE; excluding expansion vessel The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases Contains fluorinated greenhouse gases