909e Series 2/4 Zone Panel. Operating and Configuration. Manual Version V01

Similar documents
Intelligent Security & Fire Ltd

User Operation Manual

Excel-EN Conventional Fire Control Panel

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Installation, Operating and Maintenance Manual

Intelligent Security & Fire Ltd

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Intelligent Security & Fire Ltd

Conventional & Twin-wire Fire System

Application, Installation, Operation & Maintenance Manual

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Control Panel Engineering and Commissioning Instructions

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

Conventional Fire Alarm System 2014 V1.2

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Operating instructions Vigilon panel and Network node Fire detection and alarm system

Sigma XT. Extinguishant Control Panel. User Manual Man-1091 Issue 03 October 2009 (K11031M2, K11031F2)

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

USER MANUAL & MAINTENANCE GUIDE OG OO

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

The EN54 Part 2 and 4 Fire System

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

OPERATION AND INSTALLATION MANUAL

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Fire Alarm Control Panel. System Maintenance and Log Book

Fire detection and alarm system Operating instructions

Control Panel User Guide

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

SOLO Single Loop Addressable Fire Control Panel

Installation, Commissioning & Operating Manual

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

FIRE ALARM CONTROL PANEL FVC01-08

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

SECURIT 700L PLUS ENGINEERING MANUAL

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

Conventional Fire Control Panel

SECURIT 703 USER MANUAL

EUROFIRE Fire Control Panel

Doc. No.: OMPII.DOC Rev. 2 Written By: Raj Patel Checked By: AJC Approved By: JBJ Date: 03/05/05

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

SECURIT 700L USER MANUAL

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012

Surveyor Envoy-MINI 4

ID2000. operating manual

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

Installation and Operating Instructions

ZP3 Operator & Maintenance Manual Version 1

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

Control Panel User Guide

Premier Hazard STC Instructions

ORION Mini-Rep INSTALLATION MANUAL

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

FIRE CONTROL PANEL. Revision 1.1 January 1997 USER MANUAL. Emergi-Lite Safety Systems Ltd Bruntcliffe Lane Morley Leeds LS27 9LL

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

PROFYRE C8 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

Door Release Power Supply

ZoneSense PLUS. Fire Alarm Control Panel (AS4428.1) Operation & Programming MAN

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

Fire Alarm Control Panel EN54 2 & Operation & Programming MAN

Intelligent Security & Fire Ltd

SYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

Installation Manual (version 4-2 )

SERIES 3000 INTELLIGENT FIRE ALARM CONTROL PANEL ENGINEERING PROGRAMING MANUAL TABLE OF CONTENTS.. 1 INTRODUCTION.. 3 SYSTEM POWER UP.

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

BSR Addressable Fire Detection control panel. Installation operation manual

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax:

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

Menvier Fire System MF9300

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

user manual Document No , Revision 03 November 2015

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

Fire Alarm Control Panel Installation, Commissioning & Operation MAN

SALES SUPPORT DOCUMENT

Precept Marine Control Panel Application Guide

EX8. Instruction Manual: COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 AND EN54 PARTS 2 & 4

Technical Data Sheet

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

Transcription:

909e eries 2/4 Zone Panel Operating and Configuration Manual Version V01

CONTROL & INDICATION FIRE indication per zone. The zone led will flash on non-silenced zones and be continuously lit on silenced zones. FAULT indication per zone. Pulses once to show detector removed, twice for open circuit and three times for short circuit. Also when lit continuously indicates zone disabled. UPPLY HEALTHY led. Extinguished for a supply fault, (internal normal/standby supply fault green/red LED's). upply faults include, 1. Main supply failure Green & Red led's OFF 2. Battery open circuit Red led OFF-Green led ON 3. Battery volts low Red led OFF-Green led ON 4. Earth fault to -ve (upply Healthy led pulses twice.) 5. Earth fault to +ve (upply Healthy led pulses three times.) MON FAULT led. Lights for any fault, pulses twice for supply fault. FAULT led. Pulses twice for open circuit and three times for short circuit faults on the common sounder circuits (if fitted). Continuously lit indicates disablement of all common and sav-wire sounders, (this can only be done in test mode). For fault indications this nonlatching in normal conditions, but latches when there is a fire. In test mode the led pulses to show which circuit is faulty. Once for circuit 1, twice for circuit 2 and three times if both circuits are faulty. INTERNAL FAULT led. (Latching fault indication if the microprocessor is reset due to power failure, fails a watchdog test or fails a memory check). The processor will try to restart after a fault, but if it fails a memory check twice in a row then it will TOP in it's safe state, and the panel will be inoperable. AUXILIARY IOLATED. Indication that auxiliary relays have been disabled in the event of a fire or fault. ILENCE-REOUND ALARM. Push button that silences sounders or resounds them, when in fire. MUTE BUZZER. Push button that silences fault buzzer when in fault condition. Pressing and holding this button performs a lamp test. This button is also used to scroll zones for isolate mode. May also be used to silence the buzzer when in fire after the sounders have been silenced. EVACUATE. Push button control. Operation is exactly the same as if it was a fire zone and the push button initiated a fire. Remote evacuate is identical except it is non-latching and doesn t operate the aux. relay or the fire led. REET. This resets the panel and detectors, unless the panel is in fire condition and the sounders have not yet been silenced. During the reset sequence the panel lights all the LED's and sounds the internal buzzer. This has a timed 5 second reset pulse to ensure proper resetting of heads even for short blips of the button. This reset procedure may also occur for INTERNAL faults, POWER UP and when in test mode. Holding down the reset button will display the panel configuration data. TET MODE. Internal push button (with external led). In test mode, zones will now autoreset after 3 seconds, and on receipt of alarm will only operate sounders for 1* second, unless the sounders have been isolated. ounders in savwire zones not being tested do not sound. Pressing the test button once sets the panel into test mode and also automatically isolates the auxiliary relays. Pressing the test mode button a second time isolates the sounders as well to enable silent testing. Pressing the button a third time clears test mode and re-instates the auxiliaries and sounders. Test mode (+ outputs automatically isolated for test) will automatically clear after about 20 minutes, if no zones are tested. Note! Outputs isolated using isolate mode will not be cleared. *(Note! some beacons take time to charge up and may not operate in test mode.) IOLATE MODE. Led. Illuminated if any zone, and or auxiliaries / sounders have been isolated. IOLATE MODE. Push button switch that enables an engineer to select circuits to be isolated or de-isolated. The isolated zones are indicated by the zonal fault LED's. ounder and auxiliary circuits have their own leds. PAGE 2

IOLATE MODE Circuits that may be isolated are, zones, auxiliaries and sounders. (N.B. sounders may only be isolated in test mode, and can remain disabled when test mode is de-activated. ounders may be re-enabled when not in test mode if required). To select isolate mode follow this procedure. 1) Enable the controls. 2) Press the isolate mode button. Buzzer will beep, isolate mode led will flash. The zone 1 fault led will flash. (Flashing will be 3/4 on 1/4 if circuit was previously isolated, 1/4 on 1/4 off if not.) 3) Press isolate mode button to select / deselect circuit. elected isolated circuits will be lit continuously, panel will then scroll to the next circuit. 4) Press the mute buzzer button to scroll to next zone / circuit. It will scroll automatically after a second or so anyway. Repeat action 3 as necessary. 5) After all isolatable circuits are scrolled through, if any circuits have been disabled the isolate mode led will be illuminated continuously as will led s denoting the isolated circuit. 6) Pressing REET at any time between steps 3&5 will clear all disablements and revert to normal operation. This is the preferred way of re-enabling zones as it will reset any detectors that may be in alarm on a disabled zone. CONFIGURATION OF ZONE To change a sav-wire zone to conventional operation remove the relevant zone link 1,2,3 or 4. Important! If common sounder circuits are not used, at least 2 zones MUT be AV- WIRE. Note! Internal "TOP CHARGE" led pulses on every few seconds to test for supply fault. It can take up to 20s to register a supply fault. Also, as batteries are not charged during a fire condition the led is on continuously. PAGE 3

TYPICAL AV-WIRE ZONE 230 V a.c. N E L 0.5A a/s REPEAT UPPLY 24v 250mA R+ 0V HORT FOR CLA CHANGE FIRE FAULT EV HI1 LO1 HI2 LO2 HI3 LO3 HI4 LO4 ZONE CIRCUIT 1 ZONE CIRCUIT 2 ZONE CIRCUIT 3 ZONE CIRCUIT 4 NOTE! 1. DEVICE MAY BE FITTED IN ANY ORDER. 2. WIRING MUT BE IN TRICT PARALLEL. 3. FOR AV-WIRE WHEN ARE OPERATING HI= -VE LO= +VE HI= +VE LO= -VE 24v 1A max. TRANFORMER 1.5A q/b BATT + 0V IUE 1 25/7/08 IUE DATE Alt No. 909-AN-034 2 14/11/12 PROTECTOR ALARM (UK) LTD. Title 909e 4 ZONE TYPICAL TERMINAL ARRANGEMENT. AVWIRE VERION DRAWN APPROVED KC DRAWING NUMBER CALE PA909-A18

47uF 40v D D C D 47uF 40v D D C D 230 V a.c. N E L 0.5A a/s REPEAT UPPLY 24v 250mA R+ 0V HORT FOR CLA CHANGE FIRE FAULT ZONE CIRCUIT 1 EV HI1 LO1 HI2 LO2 HI3 LO3 HI4 LO4 A1 B1 A2 B2 ZONE CIRCUIT 2 ZONE CIRCUIT 3 ZONE CIRCUIT 4 CIRCUIT 1 CIRCUIT 2 NOTE! 1. DEVICE MAY BE FITTED IN ANY ORDER. 2. WIRING MUT BE IN TRICT PARALLEL. 3. POITIVE CHOTTKY DIODE BAE HOWN. NEGATIVE BAE MAY ALO BE UED. 4. CIRCUIT WHEN OUNDING, A= -VE B= +VE A= +VE B= -VE 24v 1A max. TRANFORMER 1.5A q/b BATT + 0V IUE 1 25/7/08 IUE DATE Alt No. 909-AN-034 2 14/11/12 PROTECTOR ALARM (UK) LTD. Title 909e 4 ZONE TYPICAL TERMINAL ARRANGEMENT. CHOTTKY DIODE VERION DRAWN APPROVED KC DRAWING NUMBER CALE PA909-A18 (A)

TYPICAL AV-WIRE ZONE 230 V a.c. N E L 0.5A a/s REPEAT UPPLY 24v 250mA R+ 0V HORT FOR CLA CHANGE FIRE FAULT ZONE CIRCUIT 1 EV HI1 LO1 HI2 LO2 HI3 LO3 HI4 LO4 A1 B1 A2 B2 ZONE CIRCUIT 2 ZONE CIRCUIT 3 ZONE CIRCUIT 4 CIRCUIT 1 CIRCUIT 2 NOTE! 1. DEVICE MAY BE FITTED IN ANY ORDER. 2. WIRING MUT BE IN TRICT PARALLEL. 3. FOR AV-WIRE WHEN ARE OPERATING HI= -VE LO= +VE HI= +VE LO= -VE 4. CIRCUIT WHEN OUNDING, A= -VE B= +VE A= +VE B= -VE 24v 1A max. TRANFORMER 1.5A q/b BATT + 0V IUE 1 25/7/08 IUE DATE Alt No. 909-AN-034 2 14/11/12 PROTECTOR ALARM (UK) LTD. Title 909e 4 ZONE TYPICAL TERMINAL ARRANGEMENT. AVWIRE VERION + MON CIRCUIT DRAWN APPROVED KC DRAWING NUMBER CALE PA909-A18 (B)