NOVEMBER 2012 THE EUROPEAN EXPERIENCE

Similar documents
Chilled Beams. Getting a Warmer Reception

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active.

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

Chilled Beam and Radiant Cooling Basics. Salt Lake City, UT ASHRAE Chapter December 2013 Nick Searle

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

APPLICATION GUIDE BEAMS

Modular Active. Chilled. Beams

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Chilled Beams in Labs Eliminating Reheat & Saving Energy on a Budget

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

Do All DOAS Configurations Provide the Same Benefits?

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

Senior Thesis Centre Community Hospital East Wing Addition - Proposal Keith Beidel Mechanical Option 12/05/02 1

Chilled Ceiling Condensation Control Experience In A Movable Sash Building

HVAC 101. H V A C S y s t e m s

By Thomas H. Durkin, P.E., Member ASHRAE, and James B. (Burt) Rishel, P.E., Fellow/Life Member ASHRAE

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Dream Big, Think Small: Innovative System Has All

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

Chilled Ceilings / Beams Working Principles & Applications

A REASONABLE ALTERNATIVE TO CHILLED BEAMS Dan Int-Hout Chief Engineer

Best Practices for Condensing Boilers

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

PRODUCTS TAO TAO PRODUCT: ADVANCING THE SCIENCE OF AIR DISTRIBUTION. temperature ambient optimizer. Redefine your comfort zone.

HVAC: The Next. Variable-air-volume systems. Outside-the-box thinking suggests the integration of dedicated

ASHRAE JOURNAL ON REHEAT

Don t Turn Active Beams Into Expensive Diffusers

Product Data. Features/Benefits. 36CBAC,AE,AF,AH,AQ,AN, PB,PD,PS Series Active and Passive Chilled Beams. 11 to 190 cfm

High-Performance VAV Systems

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

7. MECHANICAL SYSTEM DESIGN

NEW AR-L AR-C AND HIGH-CAPACITY LINEAR COOLING PANELS. Higher energy efficiency. Increased thermal comfort

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.80

RADIANT COOLING RESEARCH SCOPING STUDY

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

KLIMA Active Chilled Beams

CONTROLLED CHILLED BEAM PUMP MODULE

Temperature Control and Zoning of UFAD Systems

SEMCO CHILLED BEAMS INDOOR AIR QUALITY AND ENERGY SAVINGS FANLESS FILTERLESS SPACE CONDITIONING

Dehumidifying with Dedicated Outdoor Air

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

Questions??????? Thank you

Executive Summary. OA/person (cfm/p) Private and open offices, Classrooms, Building as designed

IDL20e (2 way discharge) IDS60e (4 way discharge) Inffusers. UDI (vertical discharge) Frequently Asked Questions

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

Summary Comparison of Simulation Program Features

Radiant Heating & Cooling for Commercial Buildings

terminal units only provide sensible cooling, a separate dehumidification system is usually needed.

HONORABLE MENTION: COMMERCIAL BUILDINGS, EXISTING

DADANCO Technical Paper

Mechanical Redesign, Proposal Elizabeth C. Krauss Mechanical Option September 18, 2013

Standards and Guidelines. Presented by: Aric Murray December 12, 2014

4-Pipe VAV vs. Active Chilled Beams for Labs

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK

b.) Technical Information:

Comfort and health-indoor air quality

Achieving Dry Outside Air in an Energy-Efficient Manner

Inffusers. idl20 (2 WAY) ids60 (4 WAY)

Active & Passive Beams

HVAC DISTRIBUTION and DELIVERY SYSTEMS

COMcheck Software Version Review Mechanical Compliance Certificate

CONTROLLED CHILLED BEAM PUMP MODULE

Richard Hiles ClimateMaster

COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units

Passive building in Hot and Humid Climates

Optimizing the use of Chilled Beams for health and comfort GUNNAR SVENSSON

chilled beams Redefine your comfort zone.

Benefits Offered by Passive Dehumidification Wheel Speed Control

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Halton Vario Design Guide

Technical Criteria for District Energy Ready Buildings Master Requirement ENG 108 Building Department: ,

COMcheck Software Version Mechanical Compliance Certificate

HVAC Optimization with Cold Air Distribution

Making UFAD Systems Work BY STEVEN T. TAYLOR, P.E., FELLOW ASHRAE

Active Chilled Beams. Technical Data Bulkhead-Mounted Concealed Model With Horizontal Coil and Auxiliary Drain Pan

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

2. CURRICULUM. Sl. No.

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

80-6-ISD A Better Solution for Proper Space Air Distribution

THERMAL ICE STORAGE: Application & Design Guide

Ball State Architecture ENVIRONMENTAL SYSTEMS 2 Grondzik 1. Contextual Reminder

Appendices. Included in this section are

Radiant Exchange in Stratified Environments: Considerations and Challenges for Hourly Energy Simulation of UFAD, DV, and Radiant Cooling Systems

CHAPTER 4. HVAC DELIVERY SYSTEMS

Challenges and Methods of Estimating a Conceptual HVAC Design

ASHRAE S DOAS WEBCAST: A DEEPER EXAMINATION OF THE ROLE OF HEAT PIPES

Ventilation and Humidity Control in Army Barracks Using DOAS for Better Indoor Air Quality and Energy Conservation

RADIANT COOLING SYSTEMS OPPORTUNITIES FOR RADIANT COOLING IN NORTH AMERICAN CONSTRUCTION DALE HANSCOMB, REHAU Sales Manager Building Technology

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop

The new ASHRAE-REHVA Active and Passive Beam Application Design Guide

1. Packaged Variable Air Volume (VAV) Rooftop Units (RTU) with Hot Water Reheat. 2. Geothermal Heat Pump VAV Rooftop Units with Hot Water Reheat

Architectural Engineering Senior Thesis Mechanical System Redesign

Underfloor Air Distribution:

August 15, 2013 Page 1 of 19

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

DIVISION 15 MECHANICAL

Transcription:

Radiant-cooling systems have progressed in the last few decades, garnering attention as a comfortable and energy- and material-efficient option. 1 Compared with air radiant-cooling hydronic systems use approximately half the horsepower and materials to move heating and cooling energy within a building. Although radiant cooling systems have been used in Europe for years, they are starting to be examined and installed in the United States. Low-flow injection-pumping systems can help make radiant-cooling systems even more efficient. Injectionpumping systems deliver heating and cooling energy to a variety of terminal units, including chilled ceiling panels, chilled beams, fan coils, and heat pumps, in the same piping-distribution system, even if each unit requires a different temperature. THE EUROPEAN EXPERIENCE Like many hydronic-based-system developments, commercial radiant-cooling HVAC systems originated in Western Europe during the 1980s. Traditionally, European commercial buildings were supplied only with heating systems. With the introduction of personal computers, these buildings began to require sensible cooling. Europeans then developed radiant chilled ceilings to satisfy the need for indoor cooling. Radiant chilled ceilings consist of metal panels with hydronic tubing attached. Chilled water is circulated through the panels to produce radiant and convective cooling. 2 Although many European commercial buildings have limited ceiling space, these systems require only a minimum amount of room because small pipes, rather than large ducts, are used to transport cooling energy. Newer chilled panels use plastic pipes embedded in ceilings, walls, or floors. Approximately 50 to 60 percent of the heat transfer from a radiant chilled panel is radiant, while 40 to 50 percent is convective. Chilled water temperature must be above dew point between 55 F and 60 F to prevent condensation from forming on the bottom of the panels. An application-engineering manager for Taco Inc., Greg Cunniff, PE, was instrumental in the development of the company's high-efficiency radiant-cooling system. He also co-authored the article "Single-Pipe Systems for Commer cial Applications," published in the October 2006 issue of HPAC Engineering. 1

Therefore, the driving force or temperature difference between chilled water and a room is reduced to 15 F to 20 F, while a conventional chilled-water system using 40 F to 45 F chilled water reaches temperature differences of 30 F to 35 F. As a result, higher chilled-water flow rates are required to achieve reasonable capacities. With chilled-water temperature differences or delta-ts of 4 F to 5 F, flow rates range from 4.5 to 6 gpm per ton. Conventional chilled-water systems have flow rates of 2 to 3 gpm per ton and chilled-water delta-ts of 8 F to 12 F. Chilled -water flow rates for chilled panels and ceilings are approximately double those of conventional chilled-water systems (Figure 1). Even with higher flow rates, radiant-chilled panels and ceilings have relatively low capacities, ranging from 20 to 40 Btuh per square foot of panel area. While this is adequate for cooling loads of interior spaces, it may not be adequate for exterior spaces. Exterior spaces with larger glass areas can approach 60 Btuh per square foot of floor area. For full sensible cooling in exterior spaces, the cooling load must be reduced or the ceiling panels supplemented with other cooling sources. Solar load can be reduced by using window-shading devices, such as interior blinds or exterior sun shades, that close when windows are exposed to direct sunlight. Additional cooling sources include chilled walls or floor panels. 3 Chilled-water supply T Hydronic tubing 55F to 60F AT = 4'F to 5 F 59F to 64F Chilledwater return Lay-in ceiling 50 to 60 percent radiant 40 to 50 percent convective Radient chilled panel FIGURE 1. Chilled-water flow rates for chilled panels and ceilings. 2

Because the chilled water temperature supplied to a radiant chilled ceiling is above dew point, radiant chilled panels cannot: provide latent cooling capacity? However, providing a 100 percent dedicated outside air system (DOAS) that can accomplish latent cooling allows the combination decoupled system to provide sensible and latent capacity. 4 The biggest advantage to decoupling sensible and latent loads is substantial airflow reduction. A typical air -based cooling system will require 7 to 10 air changes per hour (ACH) of recirculated and outside air. A radiant-cooling system employing a DOAS will require 1 to 2 changes of outside air per hour only. This substantially reduces the horsepower and materials required to move cooling energy. PASSIVE AND ACTIVE CHILLED BEAMS Europeans discovered that, by lowering chilled panels below a ceiling, an individual panel's convectioncooling component could be increased. This satisfied the need for increased cooling loads caused by the expanded use of computers. In addition, higher cooling capacities were needed for exterior zones to deliver better overall comfort. By lowering the panels, chilled-panel capacity can be increased to approx imately 120 to 150 Btuh per square foot of the beam or beam coil area. Also known as a passive chilled beam, this configuration resembles a beam when mounted below a ceiling and is passive because natural convection is the convectivecooling component. The higher cooling capacity of a passive chilled beam can help satisfy increased equipment loads in interior spaces and solar loads in exterior spaces. To further increase a passive chilled beam's cooling capacity, conditioned ventilation air from a DOAS can be used to flow air through a chilled coil, further increasing the beam's convective component. This configuration is referred to as an active chilled beam. Ventilation air is introduced to a chilled beam through a venturi, generating a higher velocity and, subsequently, a lowerpressure region inside of the chilled beam. This low-pressure region induces room air to flow up through the chilled coil and mix with primary air from the DOAS (Figure 2). The air flow over the chilled coil is reversed for an active chilled beam, and the induced room air flows up through the coil. Active chilled beams sometimes are referred to as "induction diffusers." Air from an active chilled beam is introduced into a space through a slot diffuser, creating a Coanda effect. Inducing warm room air to blow through a chilled coil substantially increases chilled-beam capacity. Active-chilled-beam capacities range from 350 to 600 Btuh per square foot of beam or beam-coil area. Depending on the tempera ture and quantity of primary supply air from a DOAS, this can add up to 300 Btuh per square foot of beam or beam-coil area. An active chilled beam can deliver from 500 to 900 Btuh per square foot of beam or beam-coil area between the chilled coil and primary air. 3

One thing radiant and chilled-beam systems have in common is lower air volumes (1 to 2 ACH vs. 7 to 10 ACH). Lower horsepower and fewer materials are needed to achieve the same or better levels of comfort than with air such as variable air volume (VAV), rooftop, variable volume and temperature, and constant air volume systems. Figure 3 shows the reduction in horsepower for a typical all air VAV system vs. a radiant -chilled-ceiling or chilled-beam system. Primary air nozzles Primary cold air Primary air plenum Cooling coil Cooling Suspended ceiling Mixed supply air (Coanda effect) FIGURE2. Active chilled beam. The total peak power demand of a radiant-cooling system, including transport and generation is almost 25-percent less than that of an all-air system. This decrease which includes a 50 percent reduction in transport energy is caused by the reduction of air quantities needed to cool the building. However, a radiantcooling system requires approximately twice as much chilled water flow as a conventional system, causing an increase in pump horsepower. LOWERING PEAK POWER DEMAND If the chilled-water flow of a radiant-cooling system can be reduced to that of a conventional system, peak power demand can be reduced even further. Injection pumping can achieve this goal. It has been used in radiant-heating systems for a number of years, lowering 180 F boiler water to the 100 F to 120 F needed for a radiant floor panel. The same principal can be applied to a radi ant-cooling system in reverse by raising 40 F to 45 F chilled water to the 55 F to 60 F required by a chilled ceiling panel or beam. Figure 4 shows a piping layout for a radiant-cooling low-flow/low-temperature injection-piping system. 4

45 percent Peak power (cooling), 100 percent P u m p s Fans Air-transport Other chiller loads 33 percent loads 55 percent 67 percent Air system Radiant-cooling system FIGURE 3. Reduction in horsepower from an air system to a radiant-cooling system. The primary chiller flow in an injection piping system is lower than that in a conventional system. Primary chilled U w RE a t 3 e. r temperature in an injection-piping system is 16 F, or 1.5 gpm per ton, while a conventional system ranges from 8 F to 12 F, or 2 to 3 gpm per ton. An injection piping system's flow rate is 50 percent less than that of a conventional system and 75 percent less than that of a typical radiant cooling system, resulting in a corresponding decrease in pump horsepower and materials for smaller pipe. An injection piping system keeps the transport horsepower used to move a building's heating and cooling energy to a minimum. The use of low temperature chilled water also allows spot dehumidification. A 100 percent DOAS pressurizes a building, negating infiltration of outside air. Natural infiltration temporarily can overwhelm the amount of outside conditioned air delivered by a DOAS when a building's outside door is opened, especially in humid climates. Local dehumidification is needed to overcome temporary infiltration over loads and typically is provided by fan coils installed at building entrances. A fan coil requires chilled water (50 F maximum) to achieve adequate dehumidification, which cannot be supplied by a distribution system using 55 F to 60 F chilled water for radiant panels and chilled beams. With a proper low flow piping layout, an injection-pumping system can deliver chilled water to building entrances for adequate dehumidification. Additionally, lower chiller operating temperatures (e.g., 40 F to 45 F) allow a DOAS, rather than a direct expansion unit, to use chilled water. 5

Peak power (cooling), 100 percent Figure 5 shows a comparison of peal; power demand for a low flow injection pumping system. The peak power demand of a low-flow injection pumping system. The peak demand of a low-flow injection pimping r U dean t-cooling system is 33-percent less phan that of an all air system. The transport energy for this type of radiantcooling is only 20 percent of the total energy of an HVAC system and one third of the energy of an air system. It combines hydronic heating and cooling energy transport with injection radiant heating and cooling energy delivery in a conditioned space. 45 percent 55 percent Air system Radiant-cooling system Peak power 67 percent Low-flow/low-temperature radiant-cooling system 20 percent 80 percent FIGURE 5. A comparison of peak power demand for a low-flow injection-pumping system. REFERENCES: 1) Posko, T. (2008, October). Chilled Beams in Chicago. Engineered Systems. 2) Conroy, C., & Mumma, S. (2001). Ceiling radiant cooling panels as a viable distributed parallel sensible cooling technology integrated with dedicated outdoor air systems. ASHRAE Transactions, 107, 578-585. 3) Conroy, C., & Mumma, S. (2001). Ceiling radiant cooling panels as a viable distributed parallel sensible cooling technology integrated with ded icated outdoor air systems. ASHRAE Transactions, 107, 578-585. 4) Mumma, S. (2001). Designing dedicated outdoor air systems. ASHRAE journal,43,28-31 6