Samsung EHS, XL Range of Commercial Air to water heat pumps

Similar documents
Increase your flexibility.

GOODBYE SQUARE AIR SAMSUNG AIR CONDITIONING. VRF SPECIFIERS DESIGN GUIDE 4 th EDITION

3 rd Generation of VRV. The professional solution for your professional project

Learn more about Samsung air conditioner at:

PAC (FLOOR STANDING) 2016 Samsung

Samsung Air Conditioning CASSETTE SPLIT SYSTEM AIR CONDITIONING. Samsung Air Conditioning 1

The ultimate fresh air solution.

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

Samsung Air Conditioning SURFACE MOUNTED SPLIT SYSTEM AIR CONDITIONING. Samsung Surface Mounted A/C TO PRINT.indd 1 07/10/ :25

Product Line Introduction. Karl Zhang Technical support engineer

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

VRV IV heat recovery Best efficiency and comfort solution

A single answer for multiple zones.

Heat Pump Air Conditioning Systems

A single answer for multiple zones.

History List. Version Date Update Information New EHS SPLIT TDB Released. (Modify the Spec Note)

2008 SAMSUNG SYSTEM AIR CONDITIONERS Version.2

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

DVM S Universal Communication Kit (UCK) Design Guide

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

DC Inverter Smart VRF Products(R410A)

Integrated VarIable refrigerant flow ahu/pau (r410a)

VENTILATION. Effective heat exchange and fresh air ventilation

Main Feature. Silent Mode Indoor units operate quietly with the least possible noise.

Submitted to Reference Approval Construction Unit Designation Schedule #

Submitted to Reference Approval Construction Unit Designation Schedule #

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

Ducted inverter reverse cycle air conditioning

LG HVAC SOLUTION. LG Electronics Distributed by. Copyright 2016 LG Electronics. All rights reserved.

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Samsung Free Joint Multi Air Conditioning System

Modular Air Cooled Scroll Chillers

Ducted Air Conditioning

VRF Outdoor Units. YMGI Group 601 Arrow Ln, O Fallon, MO ymgigroup.com Solar Series Mini & Modular

LG AIR CONDITIONERS Ducted Split System. Quiet & Comfortable with LG HVAC.

SAC Technical Data Book

Samsung System Air Conditioner Eco Heating System

Ducted Air Conditioning

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

LG VRF Systems. Air Conditioning Technologies

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply

LG Electronics AE Company, Commercial Air Conditioning

SINGLE. Technical Data Book. PAC for Europe (R410A, 50Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU

Samsung System Air Conditioner Eco Heating System

Do you want a versatile solution

G Series Inverter Split Systems

Air Conditioning System

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

ELECTRICAL QUANTITY WEIGHT (LB)

Samsung Air Conditioning

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

LG Electronics AE Company, Commercial Air Conditioning

CHILLER Technical Data Book DVM CHILLER for Europe (R410A, 50/60Hz, HP)

. Creating Maximum Comfort

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

PANASONIC INDUSTRIAL VRF SYSTEMS

2008 Midea Commercial A/C

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

Residential and Light Commercial Ductless Systems Catalog

Call or visit solarshop.com.au

Samsung 360 Cassette, Single Zone, Split System

Water cooled VRV IV W-series

Variable Refrigerant Flow

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

NFZP Variable Refrigerant Flow Guide Specification

Product Launch SHRMi

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

Product Brochure Smart Power. Low Profile Ducted

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Emad Chen. Head of Qatar Office Midea Commercial Air Conditioner

Blending Commercial and Residential. MiNi VRF

EHS. EHS (Mono, LT, 50Hz)

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

VRF 50Hz. Commercial Air Conditioners V1510. V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF. Commercial Air Conditioner Division Midea Group

HVS, Hydro Variable System

Product Brochure 2017

Engineering Data Book

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

Q Series. Inverter Split Systems

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Flexible & Innovative. Cooling Solutions

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

TECHNICAL NOTICE: Supplemental External Heat Control/Reduce Fan Operation Indoor Unit Firmware Version: (14/06/13) or newer

Transcription:

Samsung EHS, XL Range of Commercial Air to water heat pumps 2018 Freedom Heat Pumps Spec and price Guide

Samsung is moving with, and ahead of, our customers Put simply, our differentiation is centered on producing innovative technology that brings genuine change to people s lives. We do this by bringing a relentless focus on consumer experience and product innovation to everything we do. Sue Shim CMO (Chief Marketing Officer), Samsung Samsung understands the hugely positive impact a perfect environment can have on the workplace. We ve made it our mission to design innovative and efficient heating and cooling products that give everyone more good days at work. 2009 Best Global Brand Rank. 19 17,518 $m 2008 Best Global Brand Rank. 21 17,689 $m 2010 Best Global Brand Rank. 19 19,491 $m Why Samsung? As one of the world s largest technology companies, Samsung are delivering a complete and connected set of products and solutions for commercial properties and enterprises. Samsung will work with you to provide your customers with leading edge total building propositions utilising the latest innovative technologies. Hotel TV solutions Professional displays Smart signage Security systems Mobile devices and apps Printing solutions Telephone systems Wireless networks Air conditioning

Why Samsung is leading the way Class Leading Efficiencies (ESEER 8.00) The system adopts a dual inverter compressor that upgrades refrigerant flow and the motor's operating performance. The new flash injection technology provides high heating performance at low temperatures achieving weather dependent efficiencies of up to 5.49 (COP). High-pressure refrigerant discharge 84kW Single Outdoor Unit The single outdoor unit provides 84kW cooling from a footprint of just 0.99m 2. The 40kW outdoor unit has been innovativelypackaged to provide 40kW cooling which weighs just 162kg. Despite its size, efficiencies of 3.78 (EER) and 4.55 (COP) have been achieved. Low-pressure refrigerant suction Piping Separation 200m The 200m piping separation between outdoor and indoor units, the height difference of 110m, and first branch to furthest indoor unit distance of up to 90m all lead the industry. 110m Level differences between Indoor and Outdoor Units The longest piping length 200m Programmable Mini BMS The DMS 2 web server incorporates programmable logic and ability to connect and control third-party equipment via 8 inputs and 6 outputs providing a mini-bms capability, plus Power Monitoring function, via associated interface. 50m** Level differences between Indoor Units ** For heat pump system Smart Management Samsung provides an easy to use, smart management system that makes life simpler. With this web-based system, you can immediately access data and easily manage it for unsurpassed convenience. Wi-Fi Monitoring System With S-Checker, DVM S can be monitored by smart devices such as smart phone or tablet PC.

EHS Mono XL LT Specifications Model Name AG042KSVANH AG056KSVANH AG070KSVANH Power Supply Ф, #, V, Hz 3,4,380-415,50 Mode - HEAT PUMP HP 15 20 25 USRT Ton 12 16 20 Performance Capacity (Nominal) Cooling 42 56 65 kw Heating 42 56 69.5 ESEER 5.70 5.40 5.00 EER 3.40 3.00 2.50 COP 3.60 3.20 2.85 Power Power Input (Nominal) Cooling 12.35 18.67 26 kw Heating 11.83 17.50 24.39 Max. Current 32 46 58 Fuse Rating 40 60 75 Air Flow Rate CMM 364 364 392 Fan External Static Max. mmaq 8 8 8 Pressure PA 78.45 78.45 78.45 Water Pipe inlet/outlet mm 40 40 50 Water Connections Type Flow Rate Cooling/Heating LPM 120/120 160/160 186/200 Flange Pressure Drop Nominal kpa 60 100 120 Refrigerant Sound External Dimension R410A (GWP=2088) (tco2e) 37.58 Factory Charging kg 18 Sound Pressure 60 62 63 db(a) Sound Power 80 83 85 Net Weight kg 446 446 465 Net Dimensions (WxHxD) mm 1795 x 1695 x 765 Operating Temp. Range Cooling 5~25 C Heating 25~55 Operating Water Flow range Water Flow Rate 60~240 80~320 93~400 Minin Water stored 29 392 490 These products contain Fluorinated greenhouse gas R410A (GWP=2088). Simply expand capacity on demand A modular design provides a wide choice of configurations. You can simply and flexibly combine modules and expand capacity from 42 to 240kW in various ways to optimise energy or space savings or a balance of both. Easily increase performance & save space Its compatibility, large capacity and high space efficiency make it perfect for replacing chillers as it cuts down maintenance costs and frees-up valuable space, while expanding overall capacity. Easy to move and install modular design Its modular design and compact size reduces the time, cost and effort to transport, move and install it on site. With a small footprint it s easy to fit and combine multiple units even when there s limited space.

AG042/56/70KSVANH 5 Units: mm/inches

EHS XL MONO Prices EHS XL Split HT Indoor unit - 50C flow at -2C amb AG042KSVANH/EU AG056KSVANH/EU AG070KSVANH/EU 26.0KW 35.0kW 44.0kW All capacities allow for defrost

Split Indoor Unit Specifications 50 o C or 80 o C Hot Water Supply Model Name EHS XL LT AM160FNBDEH EHS XL LT AM320FNBDEH EHS XL LT AM500FNBDEH EHS XL HT AM160FNBFEB EHS XL HT AM250FNBFEB Type HE (50 o C) HE (50 o C) HE (50 o C) HT (80 o C) HT (80 o C) Performance Nominal Capacity Heating *1) 16.0 31.5 50.4 16.0 25.0 kw Cooling *2) 14.0 28.0 44.8 - VRF INTDOOR UNITS Refrigerant Side Required Flow Rate (Min~Max) 48 92 150 23 36 LPM Flow Switch 20 30 50 12 12 Piping Connections In/Out Ø,.inch 1 11/4 1 1 Piping Connections Liquid 3/8 1/2 3/8 Ø,.inch Gas 5/8 7/8 1.1/8 5/8 Sound Sound Pressure *3) Heating 26. 27. 30. 42. db(a) Cooling 27. 28. 31. - External. Dimension Compressor Electric Specification Weight Net kg 29 33 40 104 Dimensions. (WxHxD) Refrigerant Net mm 518 x 627 x 330 518 x 1,210 x 330 Type - - R-134a R-134a Factory Charging kg - 2.15 (3.07 tco2e) 2.15 (3.07 tco2e) MCA 2.2 24.15 32.15 A Fuse Rating 5 30 40 Operating Range Leaving Water Heating 20~50 25~80 C Cooling 5~30 - These products contain Fluorinated greenhouse gas R410A (GWP=2088) Hydro HT R134a (GWP=1430). EHS XL LT Hydro Unit hot water up to 50 o C Heat pump and Heat recovery (simultaneous cooling and heating) system Air-to-water heating and cooling Consist of DVM outdoor units and hydro unit Cassette-type indoor units are compatible for air-to-air solution Compatible with under floor heating and fan coil units Water temperature up to 50 C Integrated control system EHS XL HT Hydro Unit - hot water up to 80 o C Heat pump and Heat recovery (simultaneous cooling and heating) system Air-to-water heating Consist of DVM outdoor units, hydro unit and DHW tank Cassette type indoor units are compatible for air-to-air solution Compatible with under floor heating and fan coil units Water temperature up to 80 C Integrated control system Outdoor Indoor Outdoor Indoor Ref Piping Warm Water Water Piping Under Floor Heating Radiator Ref Piping Hot Water Water Piping Under Floor Heating Radiator Hot Water *Specifications may be subject to change without prior notice for product improvement. *1) Nominal heating capacities are based on; - Water inlet/outlet temperature : 30 C / 35 C; - Outdoor temperature : 7 C DB, 6 C WB *2) Nominal cooling capacities are based on; - Water inlet/outlet temperature : 23 C / 18 C; - Outdoor temperature : 35 C DB *3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.

EHS SPLIT XL Hydro Units Dimensional Drawing AM160/320/500FNBDEH, AM160/250FBNF*B Units: mm 330 365 Model AM160FNBDEH AM320FNBDEH AM500FNBDEH 340 518 Liquid pipe 3/8'' (ø9.52) 1/2'' (ø12.7) Refrigerant side Gas pipe 5/8'' (ø15.88) 7/8'' (ø22.23) 1-1/8'' (ø28.58) Water side Water inlet/outlet pipe PT 1 (25 A) PT 1-1/4 (32 A) Water outlet pipe 446 599 113 627 45 205 100 60 External contact Gas pipe Communication cable Liquid pipe Power cable Water inlet pipe 73.5 65 90 518 330 42 73 106 246 366 466 1210 365 Power / Communication cable Gas pipe Liquid pipe Water outlet pipe Water inlet pipe 115 333 Model AM160/250FBNF*B Liquid pipe 3/8'' (ø9.52) Refrigerant side Gas pipe 5/8'' (ø15.88) Water side Water inlet/outlet pipe PT 1 (25 A) 340

EHS XL Split Front Outdoor Units Specifications Model Name AM040FXMDEH (DGH) AM050FXMDEH (DGH) AM060FXMDEH (DGH) Power Supply Ф, #, V, Hz 1,2,220-240,50 (3,4,380-415,50) Mode - HEAT PUMP Performance HP HP 4.00 5.00 6.00 Capacity (Nominal) Cooling 12.10 14.00 15.50 kw Heating 13.50 16.00 18.00 ESEER 7.57 6.91 6.45 EER 4.19 3.79 3.60 COP 4.47 4.43 4.10 Power Power Input (Nominal) Cooling 1) 2.89 3.69 4.31 kw Heating 2) 3.02 3.60 4.40 Max. Current 22.00 (MCA) (10/ph) 24.00 (MCA) (12/ph) 32.00 (MCA) (12/ph) A Fuse Rating 32 (16/ph) 40 (25/ph) Fan Piping Connections Air Flow Rate Liquid Pipe Gas Pipe Installation Limitation CMM 110 100 I/s 1,833 1,666 Ф, mm - - - Ф, inch 3/8" Ф, mm - - - Ф, inch 5/8" 3/4" Max. Length 150 (175) m Max. Height 50.0 (40.0) Refrigerant Sound 3) External Dimension R410A (GWP=2088) (tco2e) 6.68 6.89 Factory Charging kg 3.20 3.30 Sound Pressure 50.0 51.0 53.0 db(a) Sound Power 66.0 67.0 69.0 Net Weight kg 100.0 103.0 Net Dimensions (WxHxD) mm 940 x 1,210 x 330 Operating Temp. Range Cooling -5.0 ~ 48.0 C Heating -20.0 ~ 26.0 These products contain Fluorinated greenhouse gas R410A (GWP=2088). Specifications may be subject to change without prior notice for product improvement. 1) Nominal cooling capacities are based on; Indoor temperature : 27 C DB, 19 C WB / Outdoor temperature : 35 C DB, Equivalent refrigerant piping : 7.5m, Level differences : 0m 2) Nominal heating capacities are based on; Indoor temperature : 20 C DB, 15 C WB / Outdoor temperature : 7 C DB, 6 C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m 3) Sound level was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.

AM080FXMDGH AM100KXMDGH AM120KXMDGH AM140KXMDGH 3,4,380-415,50 HEAT PUMP 8.00 10.00 12.00 14.00 22.40 28.00 33.50 40.00 25.00 31.50 37.50 45.00 7.22 7.09 6.94 6.83 3.92 3.84 3.82 3.78 5.12 4.67 4.79 4.55 5.72 7.29 8.77 10.59 4.88 6.74 7.83 9.88 18.00 (MCA) 21.50 23.50 32 25 30 30 40 135 165 166 180 2,250 2750 2767 3000 - - - - 3/8" 3/8" 1/2 - - - - 3/4" 7/8 1 1/8 100 (100) 160 (185) 30.0 (30.0) 50 (40) 6.89 7.73 8.98 10.02 3.3 3.70 4.30 4.80 56.0 58.0 59.0 62.0 74.0 74.0 76.0 79.0 VRF OUTDOOR UNIT 135.0 145.0 155.0 162.0 940 x 1420 x 330 940 x 1630 x 460-5.0~48.0-20.0 ~ 24.0 '-25.0~24.0 Small in Size and Weight. Big on Choice and Efficiency The DVM S Eco air conditioning system is a compact and efficient outdoor unit that s suitable for a wide range of homes and small businesses. It s available in a wide choice of capacities and also features a compact and lightweight design, making it very easy and economical to install and use. And it s also extremely quiet, so whatever your needs, you can enjoy optimum efficiency and comfort anywhere. DVM S Eco Conventional

EHS Split XL Top Outdoor Units Specifications Model Name AM080JXVHGH AM100JXVHGH AM120JXVHGH AM140KXVGGH AM160KXVGGH Power Supply Ф, #, V, Hz 3,4,380-415,50 Mode - HEAT PUMP HP HP 8.00 10.00 12.00 14.00 16.00 Cooling 22.40 28.00 33.60 40.00 45.00 Capacity (Nominal) kw Heating 25.20 31.50 37.80 45.00 50.40 Performance ESEER 8.00 7.43 7.23 7.78 7.38 EER 4.88 4.50 4.44 4.50 4.12 COP 5.49 5.35 5.00 4.68 4.69 Power Power Input (Nominal) Cooling 1) 4.59 6.22 7.57 8.89 10.92 kw Heating 2) 4.59 5.89 4.56 15.40 17.20 Max. Current 22.5 29.9 31.3 25.0 32.0 A Fuse Rating 25 32 40 Fan Air Flow Rate External Static Pressure Max. CMM 170 220 255 255 I/s 2,833 3,667 4,250 4,250 mmaq 8.00 Pa 78.45 Piping Connections Liquid Pipe 3/8 1/2 Ф, inch Gas Pipe 3/4 7/8 1 1/8 Installation Limitation Max. Length 200 (220) m Max. Height 110 (40) Refrigerant Sound 3) External Dimension R410A (GWP=2088) (tco2e) 13.57 19.63 17.54 Factory Charging kg 6.5 6.5 6.5 9.4 8.4 Sound Pressure 57 58 62 61 63 db(a) Sound Power 77 79 81 83 Net Weight kg 206 241 255 Net Dimensions (WxHxD) mm 880 x 1,695 x 765 1295 x 1695 x 765 Operating Temp. Range Cooling -5.0 ~ 48.0 C Heating -25.0 ~ 24.0 These products contain Fluorinated greenhouse gas R410A (GWP=2088). Optimised Refrigerant Distribution Control Since piping distance can be considerable between outdoor and indoor units, the individual indoor units perform capacity connection control and automatic refrigerant balancing to secure balanced performance between the units. P Auto pressure correction h P P (Pipe (pipe pressure loss) loss) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (If the level difference is higher than 50m, make a decision simulating by PDM kit installation Guide software whether the PDM kit should be installed or not.) *PDM kit: Pressure Drop Modulation kit 1) Nominal cooling capacities are based on; Indoor temperature : 27 C DB, 19 C WB / Outdoor temperature : 35 C DB, Equivalent refrigerant piping : 7.5m, Level differences : 0m 2) Nominal heating capacities are based on; Indoor temperature : 20 C DB, 15 C WB / Outdoor temperature : 7 C DB, 6 C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m 3) Sound level was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.

AM180KXVGGH AM200KXVGGH AM220KXVGGH AM240KXVGGH AM260KXVGGH AM280KXVGGH AM300KXVAGH 3,4,380-415,50 HEAT PUMP 18.00 20.00 22.00 24.00 26.00 28.00 30.00 50.40 56.00 61.60 67.20 72.80 78.60 84.00 56.70 63.00 69.30 75.60 81.90 88.20 94.50 7.25 6.82 6.43 7.18 7.17 6.86 6.65 4.72 4.48 3.91 4.20 4.20 4.00 3.70 5.39 4.94 4.37 4.90 4.80 4.70 4.59 10.68 12.50 15.75 16.00 17.33 19.65 22.70 16.9 12.75 15.86 15.43 17.06 18.77 20.59 39.2 42.0 44.6 55.0 60.0 67.0 73.0 50 63 63 63 75 290 340 4,833 8.00 78.45 5/8 3/4 1 1/8 1 3/8 200 (220) 110 (40) 17.54 29.23 8.40 14.0 65 65 65 69 69 69 69 89 89 89 90 90 90 90 VRF OUTDOOR UNIT 285 342 350 350 350 1295 x 1695 x 765 1295 x 1795 x 765-5.0 ~ 48.0-25.0~ 24.0 Refrigerant Pump-down and Pump-out DVM S provides the refrigerant pump-down/ out functions to facilitate easy and convenient replacement of the product, as well as additional installations and maintenance. In case of outdoor unit maintenance, it is possible for the refrigerant to recover into indoor units and pipes. It is also possible to recover refrigerant into outdoor units when moving indoor units or performing maintenance on pipes. Refrigerant Pump-out Function High External Static Pressure To properly deal with unexpected and varying installation conditions, DVM S is designed to manage high external static pressures up to 78.45 Pa. 78.45 Pa Refrigerant Pump-down Function

EHS Split XL Outdoor Units Dimensional Drawings AM080/100/120 Units: mm Any beam supporting the outdoor unit should be mounted along the feet in this direction only No. Name Description 1 Gas ref. pipe - Single Installation Over 100 (S2) Front side Front Over 100 side Over 100 Over 100 Over 500 (S1) Over 300 <Case 1> <Case 2> Height of the wall in unlimited 2 Liquid ref. pipe - 3 Power wiring conduit 2 - Ø43.7 4 Communication wiring conduit 2 - Ø34.5 5 Power wiring conduit 4 - Ø43.7 6 Communication wiring conduit 8 - Ø22.0 7 Knock-out hole for ref. piping 178 x 76 8 Anchor bolt hole 4 - Ø12

AM140/160/180/200/220 Units: mm VRF OUTDOOR UNIT Any beam supporting the outdoor unit should be mounted along the feet in this direction only No. Name Description 1 Gas ref. pipe - Module Installation 2 Liquid ref. pipe - 3 Power wiring conduit 2 - Ø43.7 Over 100 Over 100 Front side Over 100 Over 100 Over 300 (S2) Over 500 (S1) Over 200 Over 300 Over 400 Front side Over 400 Height of the wall in unlimited 4 Communication wiring conduit 2 - Ø34.5 5 Power wiring conduit 4 - Ø43.7 6 Communication wiring conduit 8 - Ø22.0 7 Knock-out hole for ref. piping 178 x 76 8 Anchor bolt hole 4 - Ø12 <Case 1> <Case 2>

EHS XL SPLIT Outdoor units EHS XL Split outdoor unit 1 phase front discharge Heat CoP SINGLE FAN AM040KXMDEH/EU 10kW 4.17 EHS XL Split outdoor unit 3 phase front discharge Heat CoP AM040FXMDGH/EU 10kW 4.46 AM080FXMDGH/EU 19kW 5.12 AM100KXMDGH/EU 25kW 4.67 AM140KXMDGH/EU 30kW 4.55 EHS XL Split outdoor unit 3 phase top discharge Heat CoP AM080JXVHGH/EU AM100JXVHGH/EU AM140JXVHGH/ET 19kW 5.49 25kW 5.35 30kW 4.68 EHS XL SPLIT LT Prices EHS XL Split LT Indoor unit - 50 o C flow at -2C amb AM160FNBDEH/EU 10kW AM320FNBDEH/EU 19kW AM500FNBDEH/EU 30kW EHS XL SPLIT HT Prices EHS XL Split HT Indoor unit - 65C flow at -2C amb AM160FNBFEB/EU~ 16.0kW AM250FNBFEB/EU~ 25.0kW All capacities allow for defrost and 50 m pipe runs between indoor and outdoor units

Building Management Server DMS 2.5 (Data Management Server) MIM-D01AN The improved Data Management Server has become smarter: it can manage a variety of different air conditioning units, and the newly upgraded functions can automatically manage the air conditioning system for you. Built-in web server for PC-independent management and remote access control Multiple upper-level control access (S-NET 3, S-NET Mini, Web-client) Central management of up to 256 indoor units including ERV, ERV PLUS and AHU User-editable control logic Accessible level management Dynamic security management Operation and error history management Weekly/Daily schedule control Power distribution function Current time management even during power failure (for 24 hours) Data storage in non-volatile memory and SD memory Emergency stop function with simple contact interface 8 External inputs and 6 outputs provide control and monitoring for third-party devices Enhanced Graphical display User-friendly icon-based unit control Color indication and icons make it easy to recognise indoor unit status Convenient and stylish controller Zoom in and Zoom out icon display

Building Management Power Monitoring Power Distribution System Power distribution to a maximum of 256 indoor units Data query for watt-hour, usage time and usage ratio Files are saved in Microsoft Excel format 1-year power distribution data is saved in storage Current actual power consumption monitoring Current-type electricity meter support (CT ratio input) 1. Operation Data Accumulation and Power Distribution 2. Data Extract Excel Format Indoor Unit Operation State 5 th Floor 140kWh 4 th Floor 610kWh 3 rd Floor 460kWh 2 nd Floor 360kWh 1 st Floor 180kWh Watt-hour Meter Interface Module MIM-B16 PIM (Pulse Input Module) Watt-hour Meter Interface Module can be exclusively used for DMS 2 power distribution, displaying power consumption for each watt-hour meter. Exclusive use for DMS 2 power distribution Connection with up to 8 watt-hour meters Pulse interface with watt-hour meters Power consumption display for each watt-hour meter Connection Supports Max.8 PIM Centralised Control DMS 2 Supports Max.8 watt-hour meters Outdoor Unit Indoor Unit

Building Management Gateways A DMS 2.5 with built-in BACnet or LonWorks gateways (all the features of a DMS2, plus interface to your chosen BMS). BACnet Gateway MIM-B17BN (DMS-Bnet) With the BMS control and monitoring function, BACnet gateway makes it easy to control the air conditioning network in various ways. It can control up to 256 indoor units, used in combination with S-NET 3 and MCM-A300N. Interface for BACnet management system Maximum 256 indoor units plus ERVs support with a maximum of 80 interface modules Includes DMS 2 functions Features for BACnet and LonWorks Gateways Control On/Off control Filter alarm reset Operation mode User control restriction Temperature setting Operation mode lock Fan speed/direction Set temperature limit ERV operation mode Emergency stop ERV fan speed Output contact control LonWorks Gateway MIM-B18BN (DMS-Lnet) LonWorks gateway is an interface for Lon-Connection to LonWorks management system, providing a more convenient way to manage your air conditioning system. It can control a maximum of 128 indoor units, used in combination with S-NET 3 and MCM-A300N. Monitoring On/Off control Operation mode Set/Room temperature Fan speed/direction ERV operation mode ERV fan speed Thermo On/Off Power distribution Operation mode lock Set temperature limit In/Out contact state Emergency stop Interface for Lon-Connection to LonWorks management system Maximum 128 indoor units plus ERVs support with a maximum of 80 interface modules Includes DMS 2 functions Filter alarm User control restriction Error code Connections BACnet BMS LonWork BMS RS485 Ethernet FTT-10A

Web Server External Contact Interface Web Server, S-NET 3 MST-P3P A PC programme designed to manage an estate of air conditioning systems via DMS2 Data Management Servers. Fully integrated PC management software Up to 16 DMS 2 connection through the ethernet Central management of up to 4,096 indoor units including ERV, ERV PLUS and AHU Schedule/Zone control Error/Operation history management Power distribution management and analysis External Contact Interface MIM-B14 Direct indoor unit control by external contact signal Window-synchronised indoor unit control Emergency control with simple contact input Indoor unit operation/error state output through relay contacts Guestroom Management Module Guest Room Management system saves you energy and money on cooling an unoccupied room: The air conditioner is activated when Key-Tag is in place and turns off when Key-Tag is removed. Example (Wall-mounted type Indoor Units: only models that include EEV support state output function) On/Off On/Off Error On/Off Key-Tag Window Open Sensor Malfunction Alarm External Device Control

And now the perfect guide has the perfect App New DVM-Pro is an advanced design automation tool that can be used in AutoCAD-based CAD mode or Windows-based Sales mode. This new programme helps you select system air conditioner equipment so you can easily and precisely design your air conditioning system. COMMERCIAL SPLIT SYSTEMS Sales Mode Indoor Unit and Outdoor Unit: Indoor unit and outdoor unit connection with accessory Piping: Basic or manual selection with system check and capacity simulation Wiring: Automatic diagram with communication wiring of indoor/outdoor/control units and electric power meters Control system: Automatic control unit selection Report: Specifications, diagrams with DWG and BMP format, quotation CAD Mode Quick, Easy, Precise Design AutoCAD add-on software (not included in new DVM-Pro) Automatic Calculation: Refrigerant and drain pipe size Automatic Selection: Refnet joint, header and distributor kit System Check: Installation regulation and refrigerant addition Easy Control System Selection Automatic Report: Piping installation diagram, equipment list and quotation Visit samsung.com/uk/dvms and download a copy from any DVM outdoor unit technical section.

Air-to-Air Heat Exchangers ERV Model Name AN026JSKLKN AN035JSKLKN AN050JSKLKN AN080JSKLKN AN100JSKLKN Air Volume (m 3 /hr) 260 350 500 800 1000 Air Flow Rate (l/s) high/low 72 / 50 97 / 71 139 / 100 222 / 156 278 / 192 Temperature exchange efficiency 70% Static Pressure (Pa) turbo/high/low 100 / 65 / 55 155 / 100 / 83 165 / 100 / 85 155 / 90 / 80 155 / 90 / 75 Sound Pressure (db(a)) high/low 31 / 22 32 / 23 35 / 24 36 / 25 37 / 26 Dimensions WxHxD mm 600 x 350 x 660 1012 x 270 x 1000 1220 x 340 x 1135 Weight kg 28.5 42.5 67 Spigot dimensions (mm - diameter) 150 200 200 250 250 *All models: 1ph 220-240V power supply (5A). Controls Control options include: MWR-VH12N Standard Individual control MWR-WE11N Combined a/c indoor/erv controller The ERV can also be interfaced with touch central controller, DMS2 and BMS gateways, using MIM-N10 interface. MWR-VH12N Automatic Energy Saving Operations ERV automatically changes its operation mode depending on the temperature difference between your indoor and outdoor environment to save energy. (Manual selection also available) Exhaust Air Outdoor Air Damper Return Air Supply Air Exhaust Air Outdoor Air Damper Return Air Supply Air Smart CO2 Sensor (Option) ERV is automatically operated to give fresh air into room by sensing CO 2 level. When the CO 2 level increases, the fan will automatically increase speed. Only the amount of air required to keep the CO 2 level on an acceptable level will be ventilated. Heat recovery mode (summer/winter) Ventilation mode (spring/autumn) CO 2 level 950ppm 700ppm Turbo High Low Heat Exchange/Temperature Exchange Efficiency, Comply with regulations to promote high efficiency energy devices, [Cooling], Indoor(24 C DB/17 C WB), Outdoor(35 C DB/24 C WB) [Heating], Indoor(22 C DB/13.9 C WB), Outdoor(2 C DB/0.44 C WB) Sound level was acquired in an anechoic room.

HRV Systems Specifications Note: Standalone ERV Air to Air Heat exchangers can be found on page 91. *Refer to the following capacities when using the product with outdoor unit: AM050FNKDEH: 3.6kW, AM100FNKDEH: 7.1 kw Model Name AM050FNKDEH AM100FNKDEH Power Supply Ø, #, V, Hz 1, 2, 220~240, 50 Turbo - 70 Cooling High - 70 VRF INTDOOR UNITS Performance Temperature Exchange Efficiency Effective Enthalpy Exchange Efficiency Heating Cooling Heating Low - 74 Turbo - 75 High - 75 Low - 79 Turbo - 60 62 High - 60 62 Low - 66 68 Turbo - 73 75 High - 73 75 Low - 79 81 Fan Outside Air Processing Capacity Air Flow Rate External Static Pressure Turbo/High/Low (UL) Turbo/High/Low Cooling *1) (DX Coil/ Element) Heating *2) (DX Coil/ Element) - 5.1(3.6/1.5) 11.5(7.1/3.4) - 6.5(4.0/2.5) 13.2(8.0/5.2) CMH 500 / 500 / 360 1000 / 1000 / 690 l/s 139 / 139/ 100 278 / 278 / 192 mmaq 16.3 / 10.2 / 8.7 15.3 / 9.2 / 7.6 Pa 160 / 100 / 85 150 / 90/ 75 Piping Connections Fuse Rating Sound Pressure Dimensions Additional Accessories Ambient Condition Liquid Pipe 1/4 Ø, inch Gas Pipe 1/2 5A Sound LeveL *3) Turbo/Mid/Low dba 36 / 32 / 28 36 / 33 / 31 Net Weight kg 61.0 90.0 Net Dimensions (WxHxD) 1,553 x 270 x 1,000 1,763 x 340 x 1,135 mm Supply/Return/Exhaust/Outside Duct Flange (Ø) 200 250 Air Filter - High Efficiency Filter (PP) Natural Evaporating Type CO 2 Sensor MOS-C1 Virus Doctor MSD-EAN1 OA *4) - 0~40 C DB, 80%RH or less RA *4) - -15~40 C DB, 80%RH or less These products contain Fluorinated greenhouse gas R410A (GWP=2088). Get Fresh Air without Temperature Loss ERV Plus is equipped with a direct expansion coil to pre-condition the outdoor air that enters your indoor environment. Outdoor air will pass through the DX coil to produce fresh air without temperature loss. Smart CO 2 Sensor ERV automatically operates to give fresh air into the room by detecting CO 2 with the CO 2 sensor (optional). *Specifications may be subject to change without prior notice for product improvement. *1) Nominal cooling capacities are based on; - Indoor temperature : 27 C DB, 19 C WB - Outdoor temperature : 35 C DB, 24 C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m *2) Nominal heating capacities are based on;,- Indoor temperature : 20 C DB, 15 C WB ; - Outdoor temperature : 7 C DB, 6 C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m *3) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions. *4) OA: fresh air from outdoor. RA: return air from room.

HRV systems Dimensional Drawing Units: mm Model A B C D E F G H I RHF050KHEA 1036 1000 987 1553 270 99 130 253 135 RHF100KHEA 1183 1135 1189 1763 340 84 160 362 170 Description No. Name 500CMH 1000CMH 1 Liquid pipe connection Ø6.35 Flare 2 Gas pipe connection Ø12.70 Flare 3 Drain pipe connection VP25 (OD32, ID25) 4 Nominal diameter for duct AM050FNKDEH AM100FNKDEH Ø200 Ø250

CONTROLS INTERFACES & CONTROLS Model INDIVIDUAL CONTROLLERS MWR-WOON Multi Function Wired Remote Controller CENTRAL CONTROLLERS MCM-A300N MCM-A202DN BMS CONTROLLERS MIM-D01AN MIM-B16N MIM-B17BN MIM-B18BN MST-R5D Touch Screen Controller (Centralised management of up to 128 indoor units) Centralised On/Off Controller (maximum of 16 Group controls (maximum of 256 indoor units)) Data Management Server (central management of up to 256 indoor units, web server Pulse Input Module (PIM) - Watt Hour Meter Interface Module (connect up to 8 watt hour meters) BACnet DMS 2 (Data Management Server with Built in BACnet Gateway - maximum 256 indoor units) LONWorks DMS 2 (Data Management Server with Built in LONWorks Gateway - maximum 128 indoor units) ZenManager Remote Management System (RMS) HEAT RECOVERY VENT HEAT RECOVERY VENTILATION UNITS Air Volume ESP Duct Dia price AN026JSKLKN/EU AN035JSKLKN/EU AN050JSKLKN/EU AN080JSKLKN/EU AN100JSKLKN/EU 260m³/h 350m³/h 500m³/h 800m³/h 1000m³/h 110Pa 155Pa 165Pa 155Pa 155Pa 150mm 926 200mm 1108 200mm 1253 250mm 1715 250mm 2 023

Learn more about Samsung heatpumps at: www.freedomhp.co.uk Copyright 2017 Samsung Electronics Air Conditioner B.V. All rights reserved. Samsung is a Registered trademark of Samsung Electronics Co., Ltd. Specifications and designs are subject to change without notice. Nonmetric weights and measurements are approximate. All data were deemed correct at time of creation. Samsung is not liable for errors or omissions. All brand, product, service names and logos are trademarks and/or registered trademarks of their respective owners and are hereby recognized and acknowledged. Samsung Electronics (UK) Ltd. Samsung House 1000 Hillswood Drive Chertsey, Surrey, KT16 0PS