INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Similar documents
CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual

cod. Doc rev. 2 12/ ACI PLUS EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL

CONNECT SOLAR MR - 7,5m

USER MANUAL ACQUAHOME 32 B BLU

INSTRUCTION FOR THE USER THC V E OIL BLU

Light oil burners. One stage operation

Installation Manual STOR C. Solar combination storage cylinder. Installation Manual

Light oil / kerosene burner

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

INSTALLATION AND MAINTENANCE MANUAL

Light oil - kerosene burner

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

cod rev. 4 08/ Kombisolar 2S EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL

cod rev. 2 06/2016 GITRÈ LN EN INSTALLATION AND MAINTENANCE MANUAL

EUROFLAT SERIES TYPES C... S... M...

Forced draught gas burner

USE AND INSTALLATION HANDBOOK

solar storage cylinder

cod rev. 0 03/ Kombisolar 3S EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL

EUROBOX SERIES TYPES CM...N SM...N MM...N

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

NOVELLA RAI RAI PV BOILERS CAST IRON BASE INSTALLATION MANUAL

Stainless Steel T-Box Extractor

CONDENSING BOILERS 45 B - 55 B INSTALLATION AND MAINTENANCE MANUAL GENERAL 1

Stainless Steel Chimney Extractor

60cm Integrated Turbo Extractor

IST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE

Stainless Steel Chimney Extractor

The guarantee on this appliance is valid for 12 months from the first day of installation.

INSTALLATION, OPERATION, MAINTENANCE AND SYSTEM MANAGEMENT MANUAL THE/TG

USE AND INSTALLATION HANDBOOK

CONDENSING BOILERS TAU UNIT OIL 35 G OIL 55 G INSTALLATION, MAINTENANCE AND SYSTEM MANAGEMENT MANUAL

WARNINGS FOR THE USER: Connect BASE conforms to: Low Voltage Directive 73/23/EEC. Electromagnetic Compatibility Directive 89/336/EEC

MHG201 Gas Hob Manual for Installation, Use and Maintenance

HYBRID STOR

BENSON LINEAR RADIANT TUBE

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

USERS MANUAL FOR GAS BOILERS

90cm Chimney Extractor

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

Installation and Operation Manual IDRA N DS. Solar solar storage cylinder. Installation and Operation Manual

COnDEnSInG BOIlERS TAU UNIT OIL USER parameters manual

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

CAST IRON ATMOSPHERIC BOILERS

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

RODI DUAL RODI DUAL HR

ST1. Mod. USE AND MAINTENANCE MANUAL

EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..

INSTALLATION GUIDE NZ AU GB IE

I/O logger box. User manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT!

PROGRAMMABLE 7-DAY THERMOSTAT

Forced draught gas burner

Instruction manual. Speedy Chef Touch

CONTROL CABINET for cascade boiler systems

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

CONDENSING BOILERS TAU UNIT OIL 28 B FLEX INSTALLATION AND MAINTENANCE MANUAL

User Manual for model

TWO STAGE HEAVY OIL BURNERS

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Oil burners Brûleurs fioul Stookoliebranders

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

2-ZONE EASYFIT INTRUDER ALARM

60cm Canopy Extractor

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

INSTALLATION, TECHNICAL ASSISTANCE CENTRE AND SYSTEM MANAGEMENT MANUAL THC V E OIL BLU

Instructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

14 Bottle Wine Chiller with Digital Display CZ51186

INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PIE CABINET

2. General information Page Warnings Page Technical characteristics Page Installation Page Front panel Page 7

INDEX WARNINGS AND RECOMMENDATIONS 2 COMPLIANCE DECLARATIONS 3 RANGE AND SIZES 3 ELECTRICITY SUPPLY 3 INSTALLATION 4 INSTRUCTIONS FOR UNINSTALLING

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

MODULAR AUTOMATIC GRANULAR ICE FLAKER

Installation and Operation Manual IDRA MS 150. Solar solar storage cylinder. Installation and Operation Manual

Stainless Steel and Glass Angled Extractor

E-COMBI EVO E-SYSTEM EVO

NATURAL CIRCULATION SYSTEMS NS-SOL SOLAR INSTALLER, TECHNICAL ASSISTANCE CENTRE AND USER MANUAL

Installation, operating and servicing instructions

AUTOMATIC SLICING MACHINE

MOD. 605 E. Made in Italy INSTRUCTION MANUAL

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

KV20, 25, 30, 45, 50, 65 & 110 Dry Pick Up

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Frost Protection Thermostat

/04.14_00. De Longhi Appliances via Seitz, Treviso Italia

Room thermostat with 24-hour time switch and large LCD

NOVELLA RAI BOILERS CAST IRON BASE INSTALLATION MANUAL

Alpha CombiMax 350 and 600

0KITMGSM00 KIT FOR BOILER CONTROL THROUGH GSM FOR ITACA - FORMENTERA INSTALLATION USE AND MAINTENANCE

POWER. Installation, user and maintenance manual. Cast-iron wood gasification boiler. The section for the user is at the end of the manual

MICROFLAT SERIES TYPES C.../U T X

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

TH100 Three in One Instant Hot Water Tap

Transcription:

CONTROL PANEL RIELLOtech PRIME INSTALLATION, OPERATION AND MAINTENANCE MANUAL

CONFORMITY RIELLOtech control panels conform to: Low Voltage Directive 06/95/EC (ex-directive 73/23/EEC) Electromagnetic Compatibility Directive 04/108/EEC (ex-directive 89/336/EEC) EN 60-6 : 07 parts 1-2-3-4 EN 730-1: 02 EN 730-2-9: 03 RANGE MODEL CODE RIELLOtech PRIME 0108 2

Dear heating engineer, Congratulations on having chosen a RIELLOtech control panel. You have selected a quality product that is designed to give dependable, efficient and safe service and to provide comfort in the home for many years to come. This manual provides information that is essential to the installation of the appliance. Used in conjunction with your own knowledge and expertise it will enable you to install the appliance quickly, easily, and correctly. Once again, please accept our thanks and our congratulations on your choice of product. Riello S.p.A. 3

CONTENTS General Safety Information 5 Precautions 5 Product description 6 Identification 6 Technical specifications 7 Accessories 7 Unpacking the product 8 Dimensions and weight 8 Installation 9 Accessing internal components 11 Electrical connections 12 Positioning the sensors 13 Wiring diagrams 14 Layout 15 Description of functions 16 Useful information 17 The following symbols are used in this manual: b = Identifies actions that require caution and adequate preparation a = Identifies actions that you MUST NOT do This manual, Code 0611 Rev. 1 (09/10) is made up of pages. 4

GENERAL SAFETY INFORMATION b Check that the product is complete and undamaged as soon as you remove it from its packaging. Contact the reseller from whom you purchased the product if you notice any problems. b This product must be installed by a legally qualified heating engineer. (In Italy heating engineers are regulated by law 37 of the 22/01/08.) On completion of the installation, the installer must issue the owner with a declaration of conformity confirming that the installation has been completed to the highest standards in compliance with the instructions provided by RIELLO in this instruction manual, and that it conforms to all applicable laws and standards. b The manufacturer declines all responsibility, contractual or other, for damage to property or injury to persons or animals caused by improper installation, adjustment, maintenance or use. b This instruction manual is an integral part of the product. It must be kept safe and must ALWAYS accompany the product, even if it is sold to another owner or transferred to another user or to another installation. If you damage or lose this manual, order a replacement immediately from your local Technical Assistance Centre. b This control panel is designed and made for use with boilers generating hot water up to 110 C, and must be used exclusively for this purpose and within its specified performance limits. PRECAUTIONS The operation of any appliance that uses electrical power demands that a number of fundamental safety precautions be respected. In particular: a Always turn the electrical power supply OFF at the main switch before commencing any cleaning or maintenance. a Do not tamper with or adjust the safety or control devices without prior authorisation and instructions from the boiler s manufacturer. a Never pull, disconnect, or twist the electrical cables coming from the appliance even if it is disconnected from the mains electricity supply. a Dispose of packaging materials in compliance with applicable standards and legislation governing the disposal of urban, domestic and industrial waste. a Never switch the control panel on even for a short period if the safety devices are not functioning correctly or have been tampered with. a All maintenance and repairs must be carried out by a legally qualified heating engineer. a Do not use water to extinguish fire in the control panel. Switch power OFF at the mains power switch to isolate the control panel electrically first. Then use a class E fire extinguisher (marked SUITABLE FOR LIVE ELECTRICAL ITEMS ) to extinguish the flames. 5

40 80 PRODUCT DESCRIPTION RIELLOtech PRIME control panels are thermostatic control panels for use with dedicated central heating boilers equipped with single stage jet burners. All thermostatic control devices comply with applicable technical and safety standards, and are housed in an ABS box. All the electrical control and safety devices in RIELLOtech PRIME control panels are factory tested in compliance with applicable technical standards. Control panels may be installed on top of the boiler or on one of its side panels, using the optional side panel mounting kit. APPLICATION CHART Burner Cascaded boilers Cascaded boilers Solar water heating systems DHW storage cylinders Direct zone 1st mixed zone 2nd mixed zone 1 RIELLOtech PRIME 2 1 2-stage with kit b To make the electrical connections to the various system components and to the burner, refer to the instructions on page 12 and to the specific instructions supplied with each item and with the burner. IDENTIFICATION RIELLOtech PRIME control panels are identified by: PANNELLO DI CONTROLLO SCHALTTAFEL CUADRO DE MANDO CONTROL PANEL - the il N code di codice number riportato on the sull'imballo box TABLEAU DE CONTROLE Kg max - the l'etichetta technical Caratteristiche data label Tecniche 0 1 Cod. : 0108 Mod. : RIELLO TECH PRIME Made in Italy 230 V AC - 50 Hz - 6.3 (A) T 011290_E1 6

TECHNICAL SPECIFICATIONS Description RIELLOtech PRIME Power supply 230 (+/-10%) ~ 50 V ~ Hz Maximum current draw 6,3 A Main power switch (two pole) 250 ~ 10(4) V ~ A Fuse 250 ~ 6,3 T V ~ A Power consumption - W Function indicators 230 V Manual reset safety thermostat (TS) (*) 110 (+0/-6) C Control thermostat (TR) field of adjustment 30 82 (+/-3) C Minimum temperature thermostat (Tm) control range 30 90 (+/-3) C working setting 40 C Boiler temperature gauge (TeC) 0 1 C Index of protection X4D IP Cable length 3 m (*) Homologated ACCESSORIES The following accessories are available, to be ordered separately: ACCESSORY CODE Two-stage burner control kit 4031067 Wall mounting kit 056 7

40 80 0 1 UNPACKING THE PRODUCT RIELLOtech PRIME control panels come in a cardboard box that also contains the instruction manual. PANNELLO DI CONTROLLO SCHALTTAFEL CUADRO DE MANDO CONTROL PANEL TABLEAU DE CONTROLE Kg max DIMENSIONS AND WEIGHT C A B D Description E F A 348 mm B 353 mm C 1 mm D 170 mm E 236 mm F 75 mm G 8 mm H 218 mm Weight 2,7 kg G H 8

ASSEMBLY RIELLOtech PRIME control panels can be installed either on the top of the boiler or on one of its side panels. Before commencing installation, check the arrangement of the holes on the top panel or side panel of the boiler. SIDE Pannellatura panels LATERALE Lato SUPERIORE TOP of boiler della CALDAIA Lato SUPERIORE TOP of boiler della CALDAIA 311 41 75 8 218 170 Lato ANTERIORE FRONT of della boiler CALDAIA Lato ANTERIORE FRONT of della boiler CALDAIA TOP Pannellatura panels SUPERIORE LATERALE SIDE della of boiler CALDAIA LATERALE SIDE della of boiler CALDAIA Lato FRONTALE of della boiler CALDAIA Lato FRONTALE of della boiler CALDAIA Once you have identified the right holes for the type of installation required, proceed as follows: - Push out the pre-formed slots on the boiler casing corresponding to the oval cable grommets in the control panel - Perforate the membranes of the control panel cable grommets. Pull out the thermostat cable and route it through the slot in the top panel - Secure the control panel to the boiler casing. 9

40 80 0 1 40 80 40 80 40 80 0 1 40 80 HORIZONTAL installation FRONT OF BOILER FRONT OF BOILER to sensor socket in boiler to sensor socket in boiler VERTICAL installation A B 0 1 0 1 0 1 A C to sensor socket in boiler Before you can install the control panel on a boiler side panel, proceed as follows: - Remove the 4 screws (A). - Remove the front trim (B), turn it through 180, and fit it back on the body of the control panel (C). - Install the control panel as instructed above. A dedicated wall mounting kit is available. Refer to the instructions provided with the kit for details on installation. 10

b Carefully unwind the thermostat cables and route them through the relevant grommets. Insert the thermostat sensors in the corresponding sockets in the boiler. Fix the sensors securely in place. Use the cable straps provided to secure the sensor cables. Cable Sensor socket Spring clip Radius mm r Sensor ACCESSING INTERNAL COMPONENTS Only personnel from Riello s Technical Assistance Service or professionally qualified heating engineers are allowed to access components inside the control panel. 1 Proceed as follows if you need to access components inside the control panel: - Turn the system OFF at the mains power switch - Remove the top panel (1) by pulling it outwards. 11

ELECTRICAL CONNECTIONS All electrical connections must be made by a legally qualified heating engineer according to the following instructions. (In Italy heating engineers are regulated by law 37 of the 22/01/08.) b The following instructions are mandatory: 1 - Use a single pole magnetic thermal trip switch and disconnector conforming to IEC-EN standards (with a contact gap of at least 3 mm); 2 - Respect the L (Phase) - N (Neutral) polarity. Keep the ground wire about 2 cm longer than the power wires. 3 - Use cables with a cross section of 1.5 mm 2 or more, complete with end terminals; 4 - Always refer to the electrical wiring diagrams in this manual when performing any electrical work. 5 - Make sure the appliance is connected to an effective ground. - Proceed as instructed in the ACCESSING INTERNAL COMPONENTS section above to access the terminals inside the control panel. - Route the connection cables through the cable grommets in the casing of the boiler or secured by the side mounting bracket. Alternatively, use the holes provided for cable glands or spiral sleeving. To use these holes, push out the pre-formed hole covers in the corresponding positions on the control panel. - Tighten the screws on the cable clamps and screw up the cable glands to secure the cables against pulling. Secure the cables to the casing of the boiler as necessary. b Use the terminals provided to connect all 230 V power users to ground. a It is strictly forbidden to use gas and/or water pipes to ground the appliance. a Do not route the power cable or room thermostat cables near hot surfaces (like heating circuit flow pipes). Use a suitable class of cable if there is any possibility of contact with parts at temperatures above 50 C. The manufacturer declines all responsibility for damage caused by failing to ground the appliance adequately or by failure to respect the wiring diagrams provided in this manual. - See the WIRING DIAGRAMS section for information on how to connect up the individual devices. L1 N PE T1 T2 S3 L1 N PE1 BURNER CH PUMP Cable glands A Cable glands B TA L N PE Power supply Boiler temperature gauge sensor TeC TR TS Tm Control thermostat sensor Safety thermostat sensor Minimum temperature thermostat sensor 12

40 80 0 1 POSITIONING THE SENSORS RIELLOtech PRIME TA AE RI MI TeC TR TS Tm - Minimum temperature thermostat sensor TS - Safety thermostat sensor TR - Control thermostat sensor TeC - Boiler temperature gauge sensor Tm PI TA - Room thermostat AE - 230V~50Hz electrical power supply MI - CH flow RI - CH return PI - CH pump Caldaia Boiler b Refer to the manual supplied with the boiler to identify the sensor sockets correctly. b Insert the thermostat sensors in the corresponding sockets and fix them securely in place. Use the cable straps provided to secure the sensor cables. 13

WIRING DIAGRAMS L1 MO1-1 FU IP TS 110 C KA1 MO1-4 MO1-5 TA TR 30-82 C MO2-5 MO2-4 MO2-1 MO2-6 L1 T1 T2 MO2-7 H2 PE H1 BA1 PI N S3 B4 BR N PE MO1-2 MO1-3 IP MO2-2 MO2-3 Tm 30-90/R40 C MO2-8 MO2-9 L1-N-PE FU IP TS TR Tm KA1 BA1 BR H1 H2 230V~50Hz power supply Fuse 6.3 A-T Main switch Manual reset safety thermostat (110 C) Control thermostat (30-82 C) Minimum temperature thermostat (30-90/R40 C) Relay contacts Relay coil Burner Burner lockout indicator Overtemperature indicator Connections to be made by the installer: TA Room thermostat PI CH pump 14

LAYOUT 1 2 3 4 5 6 7 40 80 0 1 11 10 9 8 1 - Overtemperature indicator 2 - Manual reset safety thermostat (110 C) 3 - Control thermostat (30-82 C) 4 - Boiler temperature gauge 5 - Fuse 6 - Burner lockout indicator 7 - Two pole ON/OFF switch 8 - Minimum temperature thermostat sensor (Tm) (accessible from inside) 9 - Safety thermostat sensor (TS) 10 - Control thermostat sensor (TR) 11- Boiler temperature gauge sensor (TeC) b The cables for the TS, TR, TeC and Tm sensors must be routed out of the electric control panel and through the cable grommets in the boiler during installation. 15

DESCRIPTION OF FUNCTIONS RIELLOtech PRIME control panels are equipped with 3 homologated electromechanical thermostats, a temperature gauge, a main power ON/OFF switch, function indicators and a protective fuse. Main control panel ON/OFF switch (b) This switch connects power to all controlled devices and appliances. 40 80 0 1 b A delayed action 6.3 A fuse is installed inside the control panel upstream from this switch (see wiring diagram). Control thermostat (r) The control thermostat lets you adjust boiler temperature between and 82 C The recommended setting is around 70 C. 0 1 Safety thermostat (TS) The safety thermostat shuts down the burner if boiler temperature exceeds 110 C. To restore normal functioning, remove the protective cover and press the button. Use a suitable tool if necessary. 40 80 0 1 b If the safety thermostat (TS) shuts down the burner, the red warning light comes on and any burner error signals on the burner controller are lost. Minimum temperature thermostat (Tm) This thermostat prevents cold water from circulating and causing condensation inside the boiler. It is located inside the control panel, and is preset to 40 C. Adjustment requires a suitable tool and is reserved for personnel from r s Technical Assistance Service. 16

USEFUL INFORMATION SELLER: INSTALLER: Mr.... Mr.... Address... Address... tel.... tel.... TECHNICAL ASSISTANCE SERVICE: Mr.... Address... tel.... BOILER DETAILS (From Data label): CONTROL PANEL DETAILS (From product label): Make... Serial number... Type... Lot... Serial number... Date of initial start-up.............................. 17

18

Cod. 0611 Instructions for the correct disposal of the product pursuant to European Directive 02/96/EC At the end of its working life, the product cannot be disposed of as municipal waste. It can be delivered to separate waste collection centres operated by local councils, if such exist, or to the resellers that provide this service. Separate disposal of appliances avoids possible negative consequences for the environment and the health due to unsuitable disposal and allows the recovery of the components, with significant savings in terms of energy and resources. The symbol (crossed-out wheeled bin) shown on the product indicates that the appliance must be disposed of separately. RIELLO S.p.A. - 37045 Legnago (VR) Tel. 0442630111 - Fax 044222378 - www.riello.it The manufacturer strives to continuously improve all products. Appearance, dimensions, technical specifications, standard equipment and accessories are therefore liable to modification without notice.