Single Gas Monitor 777

Similar documents
PGM100 Carbon Monoxide

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

Digital Salt / TDS Meter. 390a. The Value Leader TM

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

SENSIT HXG-2d Combustible Gas Detector

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Combustible Gas Leak Detector Instruction Manual

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

GasAlertMicroClip X3 Specifications

Combustible Gas Leak Detector Instruction Manual

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

IMR IX176 Portable Gas Detector User Manual

For the Safety of Your

ALTAIR 5X Multigas Detector Product Specification

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Fixed Life Single Gas Monitor

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

Single Gas Clip and SGC Plus User s Manual Rev 2.1 READ FIRST BEFORE OPERATION WARNING STATEMENTS / AVERTISSEMENT Activating tthe detector for the

Clip SGD. Portable single Gas Detector. User manual

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

Single Gas Clip and SGC Plus User s Manual Rev 2.3

multi-gas detector Go the distance, and save Wear yellow. Work safe.

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

Personal Single Gas Monitor. Activation Operation Troubleshooting

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Activation Operation Troubleshooting Part Number: Edition: Release Date:

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

Operate the Mutli-Gas Monitor PID

MODEL: SP2nd (Portable Single Gas Detector) Operating Manual

MODEL OX-07 Type A INSTRUCTION MANUAL FOR RIKEN PORTABLE OXYGEN MONITOR PT0E-0860

UNI 321. User s Guide

Safe Operation Manual. Honeywell IQ Force Gas Detector

MST MODEL S1 AIRLINE "CO" MONITORING AND LOW PRESSURE WARNING SYSTEM MANUAL

MULTI-GAS MONITOR. Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand

GAS-Mate. Combustible Gas Leak Detector

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

OWNERS MANUAL MODEL 451 (-101 & -201)

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

SC-01 Operator s Manual

G450. Multi-gas Detector. Field Operation Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

Monitores Personales. Personal Monitor

Product Manual. The Essential Guide for Safety Teams and Instrument Operators

03 Series: OX-03, CO-03, HS-03 Versions Operator s Manual

Model:AS8900 MULTI-GAS MONITOR O 2 %VOL H 2S PPM LEL%VOL CO PPM. Version number:as

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

T82. Instruction Manual. Single Gas Monitor GUARANTEED. FOR LIFE. P/N REV 0 PRINTED ,000 Specifications Subject to Change

Document No

RECON/4a Portable Multi-Gas Detector Operation and Maintenance Manual

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

G450. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Wireless Humidity/ Temperature Monitor Remote Wireless Sensor

Dual Laser InfraRed (IR) Thermometer

Vanguard. Toxic & combustible gas detector

SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG


Using the QRAE Plus personal multigas monitor

Warranty Registration

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

E1000 Portable gas detector

Portable Oxygen Monitor OX-07. (Type A) Operating Manual

RAE Systems Systems. User Presentation. October Protection Through Detection

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

Dräger Pac 8500 Single-Gas Detector

T.ex Single Gas Detector VISA

Sirius MultiGas Detector

Operator s Manual. 1, 2, 3, and 4-Gas Detector

Operating Instructions Compur Monitox plus

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

LD-5000 REFRIGERANT LEAK DETECTOR

SENSIT GOLD G2 INSTRUCTION MANUAL For use with combustible gases and optionally available oxygen and toxic gases.

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

ALTAIR 4 Four Gas Multigas Detector

TEK-Mate. Refrigerant Leak Detector

USER MANUAL Digital CO Monitor Model CO30

Quick Touch Pendant User Guide

This instruction manual explains the use of three models listed on the left.

Mold Alert... Operation Manual P0270

Bacharach Bodyguard 4 User's Guide

Polytector III G999 for Ex zone 0

Neotronics Impact & Impact Pro

Dräger Pac 7000 Single-Gas Detection Device

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

IMR EX610. Portable Gas Detector. Operation Manual

MGC Dock User s Manual

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

RK/ RK Carbon Monoxide Detector Operator s Manual

QUICK REFERENCE GUIDE

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

The GasWatch 2 will operate for over 3,000 hours on one battery (about 1 year normal use). And yes, the GasWatch 2 even tells the time!

Transcription:

Single Gas Monitor 777 Carbon Monoxide The Value Leader TM www.tpi-thevalueleader.com

Contents Agency Listings... 1 Safety Information... 2 General Description & Physical Specifications... 3 Product Features...4 Sensor Specifications, Alarm Setting, Bump Testing..5 Alarm Adjustment...6 Operation and Use...7 Battery, Sensor, Calibration... 8 Warranty and Repair Policy... 9

TPI 777 SINGLE GAS MONITOR INSTRUCTION MANUAL For use with Carbon Monoxide (CO) Read and understand instructions before use. Warning: To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing. Warning: To reduce the risk of ignition of a flammable atmosphere, batteries must only be changed in an area known to be nonflammable. EMC Directive (2004/108/EC) EN 61000-4-2:1995, EN 61000-4-3:2002, EN 55011:2007 1

Safety Information 1. IMPORTANT: Read and understand this manual prior to use. 2. IMPORTANT: CO instruments may show high readings for up to 30 minutes if taken from warm air to cold temperatures and vice-versa. For best results let them "soak" in the ambient conditions prior to use. 3. WARNING: Substitution of components may impair operation. 4. WARNING: This instrument contains a lithium battery which may leak or explode if improperly used. DO NOT DISPOSE OF IN A FIRE. 5. WARNING: Only service in an area known to be free of combustible gases. 6. WARNING: Instruments are not certified intrinsically safe. 7. WARNING: To verify operation prior to each day's use a function test (bump test) should be performed. If the instrument does not pass this test, full calibration should be performed. 8. WARNING: Keep all openings free from dirt, debris and foreign objects. 9. WARNING: Do not use a damaged or improperly operating instrument. Contact a service representative immediately. ONLY zero instrument in a gas free environment 2

General Description The TPI 777 is a rugged personal gas monitor. Preset alarms provide visual, audible and vibration alerts for low and high alarm conditions. Built-in "Time Weighted Average" (TWA) and "Short Term Exposure Limit" (STEL) alarms provide a greater margin of safety for the user. A custom display provides easy to read information including gas concentration and low battery indication. (See Figure 1) FUNCTION INDICATORS blinking = Low Battery High/Low Alarm Set Points: TWA/STEL Alarms: Figure 1: Custom Display PHYSICAL SPECIFICATIONS Operational Temp: -4 to 104 F (-20 to 40 C) Humidity: 15-90% RH (Non-condensing) Response Time: T90 < 30 seconds Alarms: Sound: 80 Db @ 12" (30cm) Sight: Display Alerts via LEDs Touch: Vibration Power Source: 3.6V Lithium Battery Size: 3.81" x 2.31" x 0.8" (9.67 x 5.87 x 2 cm) Weight: 3.6 oz. (105 g) Battery Life: 2+ Years Sensor: Electrochemical Construction: Impact resistant housing Belt clip and hanging loop 3

PRODUCT FEATURES The 777 is made of durable plastic. The housing is protected with a rubberized material. The front of the instrument houses the sensor and sounder. Two buttons are used to operate the instrument. The left button is used for power and to select the unit of measure for temperature. The right button is used for zeroing and adjusting the alarm level. LED's beneath the frosted areas provide visual alarm. The instrument can be worn using the belt clip on the back. The 777 cannot be turned off when it is in an alarm state. The sensor and battery are designed for 2 years of continuous normal use. 4

SENSOR SPECIFICATIONS TYPE RESOLUTION CO 1ppm Temp 0.1⁰ RANGE ACCURACY 0-999 +/- 5ppm or 5% of rdg whichever is greater 32 to 104⁰F +/- (2⁰F + 5 digits) 0 to 40⁰C +/- (1⁰C + 5 digits) ALARMS The 777 has two types of alarm. Low Alarm activates at two second intervals. The High Alarm activates at one second intervals. The sound, LEDs and vibration activate during an alarm. The alarm settings can be changed in set-up of the 777. The 777 is preset for the most common levels required. The preset alarm levels are shown below. PRESET ALARM LEVELS Type Low High TWA STEL CO 50 200 50 75 See page 6 for Alarm Adjustment instructions FUNCTION (BUMP) TEST Turn the instrument on and wait until the warm up period is over and the main display is shown. Apply 100ppm of CO gas to the sensor area at a flow rate of 200-400 cc/min. The alarm should activate within approximately 20 seconds. This test can be performed to ensure proper function prior to each day's use. Failure to pass could indicate a failure or need for calibration. SWITCHING BETWEEN ⁰F and ⁰C With the 777 on press and release the On/Off key to switch between ⁰F and ⁰C. 5

ALARM ADJUSTMENT 1. Turn the 777 on by pressing and holding the power button until the display illuminates. 2. After the warm up period when the main display shows press and hold down the Zero button for more than 3 seconds until "Ald" is displayed. 3. The alarm level can be adjusted by using the Zero button to cycle through alarm level 0 to 9. Repeatedly pressing the Zero key will cycle the alarm level number from 0 to 9 and then back to 0.The alarm levels for each selection are shown below. 4. Once the desired alarm level is selected, press and hold the Zero key for more than 3 seconds until the 777 returns to the main display. Alarm Levels ALARM TYPES The alarm type is adjustable between standard, TWA, and STEL. The alarm type is selected by performing the steps outlined on page 6. Standard - When the 777 is in the main display mode the CO concentration is shown in ppm. The alarm will sound at the Alarm Low level as outlined on page 6. Time Weighted Average (TWA) Alarm - When the 777 is set to this type of alarm the "TWA" annunciator will be displayed. In this mode the alarm is time weighted and will sound at the Alarm TWA level as outlined on page 6. A Time Weighted Average (TWA) is a threshold value based on a 8-hour workday and a 40-hour workweek. For example the TWA for carbon monoxide is 25 ppm. This means that an average of 25 ppm is considered to be the safe threshold value for an 8-hour workday. Short Term Exposure Limit (STEL) Alarm - When the 777 is set to this type of alarm the "STEL" annunciator will be displayed. In this mode the alarm is based on a 15 minute average and will sound at the Alarm STEL level as outlined on page 6. 6

OPERATION and USE Press and hold the ON button to start the instrument in an area known to be gas free and with normal oxygen amount. The following will display during start up: 1. Activate all segments and icons 2. CO (Gas type being sensed) 3. Low Alarm LevelSoftware version 4. High alarm Level 5. TWA Alarm Level 6. STEL Alarm Level 7. "HI" High alarm value displays 8. Calibration Year / Month 9. LED, Buzzer, Vibration test 10. Main display To Turn the 777 off, press and hold the Power button down for approximately 10 seconds until the 777 turns off. The 777 will beep during this time. If the 777 is turned on in an area that is not free of CO, an error will display and the 777 will need to be turned off and turned back on in a clean air environment. Attach the 777 to the outermost garment closest to your head/face as practical. Always follow federal, state, local and company regulations as it relates to the use of personal CO detectors. Alarms indicate unsafe levels. The display will show the concentration along with audible, visual and vibration indications. Manual zeroing should only be performed in a clean air gas free environment con-taining normal oxygen levels. Press the ZERO button for 2-3 seconds and release. All seg-ments of the display will flash followed by the working display. Exposure to gas in excess of sensors range specifications will result in "OL" being dis-played with the high alarm activated 7

BATTERY, SENSOR, AND CALIBRATION The battery indicator does not display until the battery begins to deplete. The battery indicator will begin to display depending on the charge left. The stages are: When the battery indicator looks like this and is blinking the battery needs replacement. The 777 must be returned to TPI for battery replacement. When SENS is displayed the CO sensor requires replacement. The 777 must be returned to TPI for sensor replacement. Calibration is recommended once per year. Please return your 777 to TPI for calibration. WARRANTY and SERVICE POLICY Your TPI 777 is warranted to be free from defects in materials and workmanship for a period of 2 years after purchase (excluding calibration). If within the warranty period, your instrument should become inoperative from such defects, the unit will be repaired or replaced at our option. This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper maintenance. Proof of purchase may be required before warranty is rendered. Units out of warranty will be repaired for a service charge. Internal repair of maintenance must be completed by a Test Products International authorized technician. Violation will void warranty. Units must be returned postpaid to the address below: TPI ATTN: SERVICE 9615 SW ALLEN BLVD SUITE 104 BEAVERTON, OR 97005 8

Notes:

Notes:

Notes:

Notes:

Notes:

Test Products International, Inc. 9615 SW Allen Blvd., Ste. 104 Beaverton, OR 97005 Tel: 503-520-9197 Fax: 503-520-1225 www.testproductsintl.com Test Products International, Ltd. 342 Bronte Road South, Unit #9 Milton Ontario Canada L9T5B7 Tel: 905-693-8558 Fax: 905-693-0888 www.testproductsintl.com Test Products International Europe Ltd. Longley House, International Drive Southgate, Crawley, West Sussex RH10 6AQ Tel:: +44 (0) 1293 530196 Fax: +44 (0) 1293 531870 www.tpieurope.com