TECHNICAL SPECIFICATIONS

Similar documents
TECHNICAL SPECIFICATIONS

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

PROVIDING HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

RGE 13 A T - 1 A

13 GEP A L P - 1 A

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

RSG16**S1M. Split System Air Conditioner 16 SEER

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

Condensing Units & Air Handlers

TECHNICAL SPECIFICATIONS

50TM TFF COMBINATION HEATING/COOLING UNITS

PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

50TM COMBINATION HEATING/COOLING UNITS

13 SEER CONDENSING UNITS & AIR HANDLERS

Product Data. Fig. 1 - Unit 50VR -A

AND WORRY-FREE PERFORMANCE

TECHNICAL SPECIFICATIONS B6VMMX

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

36,000-62,000 BTUH Nominal Capacity

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

High Heat COP. High/Low Stage

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Unit Features & Benefits RQPM/RQRM Series

seer 4HP16LT Split System Enhanced Heat Pump Features and Benefits WARRANTY

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer.

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

48TM GAS HEATING/ELECTRIC COOLING UNITS

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

TECHNICAL SPECIFICATIONS

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Whirlpool Split System 13 SEER Air Conditioner W2C3. Features

PAR5. Product Specifications

T P A 120 S 4 S N 1 Y

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

Corp L2 Revised

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

LIGHT COMMERCIAL. Packaged Units and Split Systems APPLICATIONS: OFFICES RETAIL STORES RESTAURANTS CLINICS

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

TECHNICAL SPECIFICATIONS

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT


TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

16 SEER Split System Enhanced Heat Pump 4SHP16LT. Features and Benefits WARRANTY

2 shp 13 lc 1 36 t - 1 a

UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Commercial High-Efficiency Condensing Units

Bosch BVA Series Air Handler

Ruud Standard Efficiency Air Handler

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)

48TF GAS HEATING/ ELECTRIC COOLING UNITS

MACH N-407 Heat Pump Air-Cooled Chiller

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

TECHNICAL SPECIFICATIONS

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

Model 655A Sizes

PAJ3. Product Specifications

Transcription:

TM TECHNICAL SPECIFICATIONS Model PPH1SD Series M1200 Product Line Single Packaged Heat Pump 13 SEER - 3, 4 and 5 Ton Units

M1200 12 YEAR ALL PARTS LIMITED WARRANTY M1200 WITH UPGRADED WARRANTY PACKAGE - 12 YEAR ALL PARTS & LABOR LIMITED WARRANTY Both the standard and upgraded limited warranty packages offer a 12 Year Dependability Promise to replace the entire unit, if the unit s major component (heat exchanger or compressor) fails within the first 12 years of operation, to the original owner. All split system products must be installed with a matched indoor air handler or indoor coil to qualify. Product registration (by consumer or dealer) required for 12-year Warranty and Dependability Promise within a limited period of time after the installation. See current warranty document for details. This can be viewed at www.maytaghvac.com or ask your sales representative. Dealer is responsible for registration of labor portion of warranty. The PPH1SD Series single packaged heat pumps are high efficiency self contained cooling and heating units that can be installed on a roof or on a slab. The convertible unit design makes installations simple in all applications. Units are ETL and ETLc listed. Features and Benefits Compact Footprint/Low Profile Easy to handle and transport. Five Minute Restart Time Delay When the unit shuts down, a five minute delay keeps the unit from restarting, eliminating the highest cause for compressor failure. Heavy-Gauge, Full Perimeter Base Rails Facilitates forklift handling and curb mounting. Convertible Air Delivery Horizontal or downflow to accommodate rooftop or horizontal application. Galvanized Steel Cabinet Unit is trimmed in a silicone-protected polyester finish with a 950 hour salt spray finish that resists corrosion 50% better than comparable units. Plastic Coated Coil Guard and Mesh Hail Guard Will never rust and protects the coil from being damaged by balls, lawnmowers, hail etc. Externally Accessible Service Ports Quick access to refrigerant system without disrupting operation. Access to Controls and Major Components Easy in and out service. Corrosion-Resistant Drain Pan Quickly drains away evaporator condensate. Service Access Panels Allows easy access to all major components and the compressor. Designed to make servicing easier for the Contractor. Easy to Install Electric heat strip provides up to 20 KW of heat output. Proven, Industry Standard Components Easier service and availability. Quiet Operation and Low Vibration 20" fan blade combined with custom venturi condenser fan. Accessories Roof curbs and more. Time / Temperature Defrost A reliable, industry standard control offers various time settings to meet any type climate. Low Pressure Control Loss of charge protection ensures long compressor life.

IDENTIFICATION CODE P = Premier P = Packaged H = Heat Pump SPECIFICATIONS P P H 1 S D 024 K Series Square Duct Connections D = 13 SEER Electrical Code K = 208/230-60-1 Nominal Capacity x 1000 Btu Model Number BLOWER PERFORMANCE PPH1SD 036 048 060 Performance Capacity - Heating BTUH 33,500 45,000 51,000 Efficiency - HSPF 7.7 7.7 7.7 Capacity - Cooling BTUH 34,800 46,000 55,500 Efficiency - SEER 13.00 13.00 13.00 EER (Btuh/watt) 11.0 11.0 11.0 Electric Rating - 60Hz (a) Phase 1 1 1 Operating Voltage Range 187-253 187-253 187-253 Min. Circuit Ampacity (a) 27.7 36.7 42.5 Field Wire Size - AWG (a) 10 8 6 Total Unit - Amps 23.2 30.8 35.5 Compressor Data Volts 208-230 208-230 208-230 Rated Load Amps 17.9 23.6 28.0 Lock Rotor Amps 88 137 169 Indoor Blower Type Fixed Torque Fixed Torque Fixed Torque Motor HP-RPM Range 1/2-1100 3/4-1400 3/4-1600 Motor - Amps 4.1 6.0 6.0 Outdoor Fan Motor - HP / RPM 1/4-1100 1/4-1100 1/3-1000 Motor - Amps 1.2 1.2 1.5 Fan Diameter / CFM 20 / 3800 20 / 3800 20 / 4000 Refrigerant Charge - Oz. 127 293 224 Net Weight lbs. 460 570 580 Shipping weight lbs. 470 580 590 Model Number PPH1SD 036 048 060 * * * * * * External Static Pressure Drop-inches water column Speed 0.1 0.2 0.3 0.4 0.5 0.6 Tap T1 1150 1050 1000 950 850 780 Tap T2 1230 1190 1120 1080 1000 950 Tap T3 1400 1350 1200 1150 1080 1030 Tap T4 1600 1500 1400 1300 1200 1050 Tap T5 1700 1650 1600 1565 1530 1480 Tap T1 1515 1450 1380 1350 1300 1250 Tap T2 1580 1520 1460 1400 1360 1300 Tap T3 1740 1690 1650 1600 1540 1500 Tap T4 1960 1910 1840 1820 1780 1740 Tap T5 2090 2050 2010 1975 1940 1900 Tap T1 1515 1450 1380 1350 1300 1250 Tap T2 1580 1520 1460 1400 1360 1300 Tap T3 1740 1690 1650 1600 1540 1500 Tap T4 1960 1910 1840 1820 1780 1740 Tap T5 2090 2050 2010 1975 1940 1900 * Denotes factory set cooling and heat pump speed ** Denotes factory set electric heating speed 3

DIMENSIONS 24.9 3/4" NPT Female Drain Connector DOWNFLOW SUPPLY DUCT OPENING CG 47.5 13.5 16.0 13.5 16.0 B 13.3 12.0 12.0 A 23.5 DOWNFLOW RETURN DUCT OPENING Top View Model Number PPH1SD Unit Weight Center of Gravity A B Height (in inches) with base rails C without base rails 036 460 28.0 25.5 35.0 35.3 048 570 29.5 26.0 43.0 39.3 060 580 29.5 26.0 43.0 39.3 4

DIMENSIONS continued 1.8 1.75 Ø Power Entry (Capped) 1.25 Ø Power Entry 30.0 0.88 Ø Control Wiring Entry 27.2 23.6 4.00 Side View 5.0 4.0 C SUPPLY 13.5 RETURN CONDENSING COIL 16.0 8 16.0 13.5 14.7 13.45 11.75 22.75 55.8 Back (Duct) View 5

ELECTRICAL DATA Multiple Supply Circuit Option Single Supply Circuit Option Circuit A (Compressor & Fan) Circuit B (Blower & Heater) Circuit C (Heater Only) Model Number Heater Installed Nom. KW Minimum Circuit Amp. Gauge (60 Gauge (75 Gauge (90 Maximum Overcurrent Rating* Minimum Circuit Amp. Gauge (60 Gauge (75 Gauge (90 PPH1SD-X36K 0 27.9 10 10 10 45 - - - - - - - - - - - - - - - Maximum Overcurrent Rating* 5 52.9 6 6 8 60 23.6 10 10 10 40 29.3 10 10 10 30 - - - - - 8 67.5 4 4 6 70 23.6 10 10 10 40 43.7 6 8 8 45 - - - - - 10 77.9 3 4 4 80 23.6 10 10 10 40 54.3 6 6 8 60 - - - - - 15 102.9 1 2 3 110 23.6 10 10 10 40 54.3 6 6 8 60 25 10 10 10 30 20 127.9 00 1 2 150 23.6 10 10 10 40 54.3 6 6 8 60 50 6 8 8 60 Minimum Circuit Amp. Gauge (60 Gauge (75 Gauge (90 Maximum Overcurrent Rating* Minimum Circuit Amp. Gauge (60 Gauge (75 Gauge (90 Maximum Overcurrent Rating* PPH1SD-X48K 0 36.7 8 8 8 60 - - - - - - - - - - - - - - - 5 61.7 4 6 6 80 30.7 8 8 8 50 31.2 8 8 8 35 - - - - - 8 76.3 3 4 4 90 30.7 8 8 8 50 45.6 6 8 8 50 - - - - - 10 86.7 2 3 4 100 30.7 8 8 8 50 56.8 4 6 6 60 - - - - - 15 111.7 0 2 2 125 30.7 8 8 8 50 56.8 4 6 6 60 25 10 10 10 30 20 136.7 00 0 1 150 30.7 8 8 8 50 56.8 4 6 6 60 50 6 8 8 60 PPH1SD-X60K 0 42.5 6 8 8 70 - - - - - - - - - - - - - - - 5 67.5 4 4 6 90 36.5 8 8 8 60 31.8 8 8 8 35 - - - - - 8 82.1 3 4 4 100 36.5 8 8 8 60 46.4 6 8 8 50 - - - - - 10 92.5 2 3 4 110 36.5 8 8 8 60 56.8 4 6 8 60 - - - - - 15 117.5 0 1 2 125 36.5 8 8 8 60 56.8 4 6 6 60 25 10 10 10 30 20 142.5 00 0 1 150 36.5 8 8 8 60 56.8 4 6 6 60 50 6 8 8 60 *When overcurrent rating exceeds 60, internal circuit breakers must be installed in addition to branch circuit protection at distribution panel. HEATER APPLICATION MATRIX Model Number H3HK-005H-01 H3HK-008H-01 H3HK-010H-01 H3HK-015H-01 H3HK-020H-01 H3HK-015H-21 H3HK-020H-21 917166 917167 917168 917169 917170 917172 917173 PPH1SD-036K X X X(2) X(2) NA X NA PPH1SD-048K X(2) X(2) X(2) X(3) X(3) X(1) X(1) PPH1SD-060K X(2) X(2) X(2) X(3) X(3) X(1) X(1) NA = Not Applicable. ( ) = Number of internal circuit breaker kits required. IDENTIFICATION CODE H 3 HK 008 - H 0 1 Heater Stages 3- Pkgd. Units Heater Kit Electric Heater KW Electric Code H=240-1-60 No. of Breakers

ACCESSORIES Description Part Number Roof Curb (8 ) 547830 Roof Curb (14 ) 547831 Roof Curb (18 ) 547850 Roof Curb (24 ) 547851 Filter Rack, All Downflow Applications (not required with economizer) 547885 Filter Kit (not required with economizer) for Horizontal Applications PPH1SC 036 547888 Filter Kit (not required with economizer) for Horizontal Applications PPH1SC 048K - 060K 547889 Universal Hard Start Kit 912933 High Pressure Switch Kit 913550 Low Ambient Kit 913549A P-Trap Kit 913810 Outdoor Thermostat Kit 913852

CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Maytag is a registered trademark of the Maytag Corporation and is used under license. 993B-0207 (Replaces 993B-0306) Printed in U.S.A. (02/07)