Industrial Strength Leak Detection

Similar documents
Industrial Strength Leak Detection

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Fuel Leak Detection Find Leaks Before They Find You

FIND LEAKS BEFORE THEY FIND YOU. Leak Detection and Location Systems

fuel leak detection find leaks before they find you

Tyco Thermal Controls provides complete heat tracing and speciality. wiring solutions for the industrial, commercial, and residential markets.

TraceTek Leak Detection

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

TraceTek FIND LEAKS BEFORE THEY FIND YOU

TTSIM-1 Sensor Interface Module

Sensor Interface Module Installation/Operation Instructions

C910 Series. Single-point heat-tracing control system

water leak detection

TT7000-HUV TraceTek Sensing Cable for Strong Mineral Acids

ACCS-30. Multipoint commercial heat-tracing control system

TraceTek TT1000 Modular Sensing Cable

RayClic Connection System

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

Water Leak Detection Find Leaks Before They Find You

C A Heating Cable Gland Kit

Leak Detection and Location Systems

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

TE Connectivity's AMP NETCONNECT Cable Management

Installation, Operation and Maintenance Manual

aquilar - leak detection solutions

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

PRODUCT SELECTION GUIDE FOR WATER SENSING SYSTEMS

QuickStat-TC Installation & Operation Manual

Gardian W51. Approvals

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

Supervisor Standard Edition

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

Raychem Heating System

aquilar - leak detection solutions

For Complete Fire and Gas Solutions

TraceTek TT1000 Modular Sensing Cable

15203B 25203B 35203B Uniaxial Biaxia Triaxial

AT-G-SENSE Gas Sensing System

Cable Actuated Sensor Industrial User Scalable 4 20mA

ASAHI/AMERICA Leak Detection Basics

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING.

AquiTron. AT-WM Water Monitor DATA SHEET

RF one-step BNC/TNC connectors for coaxial cable termination

XAGA 550/550-L. Aerial Splice Closure. 1. General Description. 2. Warnings. 3. Cautions

Technical Paper. PPTC Circuit Protection for Power Management in Portable Communications/PDA Equipment

PolySwitch TS600 Overcurrent Protection Devices

Cable Actuated Sensor Industrial User Scalable VDC Output

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

TT5000-HS (for fuel leaks) TT5001-HS (for solvent leaks) TraceTek Sensing Cable for Underground Leak Detection

Seal Kits for BUDI Enclosures

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

RS485 MODBUS Module 8AI

Flexible Air-sampling Smoke Detection

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

REACTIon TANks. Pump control-telemetry Unit

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

OPERATION MANUAL MODEL & ACCELEROMETER

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

HTC-915-CONT. Heat-Trace Control system

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

LINEAR HEAT SERIES FIBER OPTIC LINEAR HEAT DETECTION SYSTEM

MODEL 4000A & 4001A ACCELEROMETER

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

86BSD Digital Output

OPERATION MANUAL MODEL 805 ACCELEROMETER

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

Minimize Leaks Maximize Asset Protection

FOSC. Fiber Optic System Technology. Fiber Optic Splice Closures (FOSC-400)

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

PT9420 (Extended Range)

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

86BSD Digital Output

PT9600. Cable Actuated Encoder Reel. General. Environmental

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

AT-G-DETECT Gas Sensing System

XL-Trace System Application and Design Guide

/8 DIN Level Indicator

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

Tank Gauging Products for Bulk Liquid Storage Tanks. Simple, Safe and Reliable Inventory Measurement

BID-SPEC_INTEGRA_100 Rev. 0. Bid Specifications and General Description OPW SiteSentinel Integra 100 Automatic Tank Monitoring System

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Model 4001 Series Single Channel Controller

TT3000 and TT5000 Series

PT9150 (Extended Range)

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Fuel Management System Setup Guide

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Transcription:

Industrial Strength Leak Detection Don t let an undetected leak or spill ruin the environment or your reputation...

TraceTek Technology: Find leaks before major damage is done... TraceTek Technology: Sensor cable suited to the task TT3000 for acids, bases and other hazardous fluids with water content TT5000 for gasoline, jet fuel, diesel, crude oil, lube oil and other hydrocarbon based liquids TT5001 for organic solvents TT7000 for strong acids and bases Detect a spill, locate the source of the leak and take corrective action before an incident becomes a news story. The key is quick detection and accurate location at the source of the leak. TraceTek sensor cable and monitoring systems make it possible. If your business involves the transportation, storage, processing or consumption of hazardous fluids, the possibility of a leak must be considered. Whether your concern is gasoline, jet fuel, diesel, crude oil, acids, bases, contaminated water or any other hazardous liquid, TraceTek can provide a leak detection system tailored to your needs. TraceTek leak detection systems can detect and pinpoint the source of a leak to help you take decisive action long before the spill can ruin your reputation. Reliability Simple detection and location circuit Radiation cross-linked, fluoropolymer materials No exposed metal parts Tens of thousands of installations worldwide in virtually every type of environment Easy installation, simple maintenance Simple, easy to understand alarm panel No field calibration required Self-monitoring for damaged or broken cable Easy to extend or modify in the future Accurate leak location The entire cable is a sensor Leaks are reported to the nearest foot or meter with better than 0.1% precision Instrumentation flexibility Small area, single channel monitoring with relay output Long-length cable monitoring with precise leak location reporting Single circuit / multiple circuit options Alpha numeric user interface Output to host systems via relay contacts, 4-20 ma analog current loop or serial data ports (Modbus or Johnson Controls Metasys format) Multiple circuit capability A single circuit can be as short as 1 meter or as long as 1500 meters TTDM-PLUS Alarm Panel can monitor a single circuit or up to 128 circuits

TraceTek Leak Detection Systems can operate as stand-alone independent alarm systems or they can easily be integrated with: SCADA system Factory Automation Systems Building Management Systems Distributed Control Systems Programmable Logic Controllers A TraceTek Leak Detection System consists of Sensor Cable, Sensor Interface Modules and Alarm Panels. Additional sensor options include: float switches, point probes, pressure switches or any other sensor device that can provide a contact closure. Instrumentation options include: low voltage / relay contact devices, instruments for hazardous locations, battery powered flashing light indicators, and other options tailored to the application. 1

TraceTek Cable: Direct buried applications: Leak Detection and Monitoring for: single wall fuel pipe above ground storage tanks buried valves and fittings TT5000 Fuel Sensor Cable is used to monitor the soil under and around fuel carrying pipes and tanks. The TraceTek system detects and reports the location of a fuel spill before major damage can occur. Leakage rates far below the threshold of a SCADA (Supervisory Control and Data Acquisition) leak detection system can be detected while contaminated soil is still measured in a few cubic meters rather than truckloads. Jet fuel transfer line with blue PVC slotted conduit for TT5000 installed at a major international airport. TT5000 Sensor Cable in PVC conduit can be positioned below buried valves or beneath Aboveground Storage Tank bottoms. The TraceTek system reports the location of a leak to an accuracy of ±1 meter along the length of a pipeline or beneath a tank floor. The slotted PVC conduit allows the sensor cable to easily be removed and inspected for simple and direct verification of a leak before digging. Detect and locate a leak before damaging the aquifer! 1 hour 4 hour 10 hour 20 hour Above, typical progression of an 8 liter per hour leak The intention is to detect a leak when the affected area is still small and easy to clean up, with a minimum of environmental damage. 2

Interstitial and Indoor applications: Interstitial monitoring for double wall pipe. Indoor monitoring under raised floors, for chemical supply and return piping and other hazardous fluid leak detection. TraceTek 3000 sensor cable is designed to detect waste water, acids, bases, or any liquid that is conductive. Rapid detection, accurate location reporting and excellent chemical resistance make TT3000 a popular choice for double containment pipe systems. Wherever complex piping, hazardous chemicals and critical working environments come together, a system to monitor for fluid leakage becomes critical. TraceTek 5000 is the sensor of choice for fuel piping and underground storage tanks. TraceTek 5000 detects fuel but ignores water. Branch connectors simplify tracing complex manifolds and hydrant systems. Every meter of cable has a unique address so that leaks are detected where they start and repairs can be accurately directed. TT3000 (for conductive liquids) and TT5001 (for organic solvents) are used to monitor the chemical supply systems in semi-conductor manufacturing facilities, pharmaceutical plants, and similar high-value facilities that demand excellent environmental monitoring. TraceTek cable provides the flexibility to monitor long runs of pipe or a single valve box where visual inspection is difficult or impossible. Precise location reporting assists in rapid and accurate dispatch of emergency response teams. 3

TraceTek Technology: TraceTek Technology and System Components TraceTek Sensor Cables are made with materials that have excellent chemical resistance. The TT3000 sensor cable uses conductive polymer-coated wires separated by the solid Kynar insulated core. TT3000 is quick to reset when removed from a spill because the solid core resists accumulation of liquids and contaminants. TT3000 sensor cable detects conductive liquids such as waste water, acids, bases, cooling water etc. TT7000 sensor cable is similar to TT3000, but is sensitive only to strong acids and bases. TT3000 TT5000 sensor cable is designed to detect and locate liquid hydrocarbon fuel spills. The material properties of the core and jacket materials allow the cable to detect and locate liquid fuels such as gasoline, jet fuel and diesel while at the same time completely ignoring water. TT5001 sensor cable is similar to TT5000, but is sensitive to organic solvents. TT5000 TTDM-PLUS Alarm Panel can act as a stand alone leak detection control panel or as the display and user interface for a multiple circuit network of leak detection circuits. TTSIM-1 Sensor Interface Module is the key component of multiple circuit leak detection networks. Leak detection information and cable status is digitized and transmitted to a TTDM-PLUS panel for display or directly transmitted to Factory Automation Systems, PLC s, DCS etc. TTC-1 is a good choice when a short length of sensor cable is used to monitor a small area and a simple relay contact is sufficient. TTDM-PLUS TTSIM-1 Other TraceTek monitoring options include: TTA TTG TT-FLASHER TTSA For small area monitoring in hazardous locations Multiple sensor cables (4 or 12 circuits) in hazardous locations Battery powered, flashing light indicator for hydrocarbon leak detection For small area monitoring in non-hazardous locations 4 TTC-1

System integration and telemetry options: Relay Contacts TraceTek instruments are available with leak alarm and trouble contacts for signaling a host system. 4-20 ma analog current TTDM-PLUS has an analog output. The installer can adjust scaling and channel assignment through simple menu commands. Serial Data Port TTDM-PLUS and TTSIM offer full data access via the Modbus (J-Bus) protocol. TTDM-PLUS has a user selectable RS232 or RS485 serial port. TTSIM is RS485 only. Telemetry The standard connection method between TTDM- PLUS and TTSIM s is twisted-pair copper wire. When network distances increase beyond 1200 meters there are other options available including: fiber optics, spread spectrum radios and cell phone-based alarm reporting. For a single small area, a TTC-1 can provide relay contact output to a PLC or building management system. The combination of sensor cable and a TTC makes an effective drip tray monitoring system. Knowing the leak location is important when the size of the monitored area gets larger and when the sensor cable is concealed by walls or raised floors. TTDM-PLUS and the TraceTek sensor cable provide excellent detection and location performance with accuracy to 1 meter. For clean rooms and similar building applications a single TTDM-PLUS alarm panel can monitor the entire facility for hazardous liquid spills. Here several TTSIM units are monitoring specific areas while the TTDM-PLUS monitors the entire network. TT5000 can be installed along a buried pipeline using a cluster of 4 TTSIM units mounted in a single enclosure. Power points are required approximately every 5 to 6 kilometers. 5

TraceTek and Tyco Thermal Controls The TraceTek Leak Detection and Locating System was developed by Raychem Corporation in the mid 1980s. The TraceTek Products Group became part of Tyco Thermal Controls when Raychem Corporation was aquired by Tyco International in 1999. Tens of thousands of TraceTek systems have been installed over the years in a variety of leak detection applications ranging from water detection in commercial buildings to hazardous fluid monitoring to leak detection for fuel storage and transportation systems. The versatility of the TraceTek technology lends itself to customized designs that detect and locate liquid leaks and spills before equipment or environmental damage becomes significant. Whether it s a matter of personnel safety, the need for 24/7 reliability, or avoiding expensive environmental clean-up costs and penalties, the TraceTek system can be a key element of your facility operating and security systems. Tyco Thermal Controls is an ISO 9001 Certified Development and Manufacturing Facility with sales and support operations in over 40 countries around the world. Distributed By: For more information see: www.tracetek.com www.tycothermal.com Or contact us at one of these locations: U.S.A. Tyco Thermal Controls 300 Constitution Drive Menlo Park, CA 94026-1164 USA Tel: (800) 545-6258 Fax: (650) 474-7215 Europe Tyco Thermal Controls Staatsbaan 4A 3210 Lubbeek Belgium Tel: (32) 16/213-571 Fax: (32) 16/213-600 Asia Tyco Thermal Controls 9th floor, Yeul-chon Building, 24-1, Yeoido-Dong, Youngdeungpo-ku 150-010 Seoul, Korea Tel: (82) 2-2129-7731 Fax: (82) 2-785-4700 Important: All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their particular application. Tyco Thermal Controls makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Thermal Controls only obligations are those in the Tyco Thermal Controls Standard Terms and Conditions of Sale for this product, and in no case will Tyco Thermal Controls or its distributors be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Tyco Thermal Controls reserves the right to make changes without notification to Buyer to processing or materials that do not affect compliance with any applicable specification. TRACETEK and TYCO are trademarks of Tyco Thermal Controls, LLC or its affiliates. Printed on recycled paper 2002 Tyco Thermal Controls LLC Printed in USA H57065 7/02 MODBUS is a registered trademark of Schneider Automation Inc. METASYS is a trademark of Johnson Controls, Inc. KYNAR is a registered trademark of Atofina.