Centrifugal Pumps Engineering Information

Similar documents
Worthington D-834. vertical inline cast iron pumps

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

FLANGE-MOUNT CENTRIFUGAL PUMPS

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

CLOSED COUPLED CENTRIFUGAL PUMPS

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

Full-line Product Overview

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

Centrifugal Pumps acc. to EN / ISO 2858 with Shaft Sealing Type NCL

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

Centrifugal Pumps acc. to DIN EN ISO 2858 with Shaft Sealing Type NCL

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

MODEL 664A MODEL 662A MODEL 663A MODEL 661A AURORA. 660 Series SINGLE STAGE SOLIDS HANDLING VORTEX PUMPS

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

TYPE VSM/VSMS VERTICAL SPACE MISER PUMPS

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

DUPLEX CONDENSATE TANK SYSTEM

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

Dean Pump High Temperature Chemical Process Inline Pumps

Goulds Trash Hog. Self-Priming Solids Handling Pumps

Worthington D-1100 vertical in-line pumps

380 Series Multi-Stage Centrifugal Pumps

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

MARLOW PUMPS RECIRCULATION

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

569, 570, 571, 572 Series

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

569, 570, 571, 572 Series

CPVC Horizontal. Series HV. Centrifugal Pump. Flows to 132 GPM Pressure to 81 Ft. TDH. Model HV-1 1/2DV

SERIES 1600 Quality Design Features Assure Long, Trouble-Free Service

5. CONDENSATE PUMPS/UNITS

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

KEENER GRINDER PUMPS

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

316 Stainless Steel Close- Coupled Self-Priming Flexible Impeller Pumps

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Worthington CNG process pumps.

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

568X, 587X, 588X Series

Industrial. Solutions brands you trust. Product Overview

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

STAINLESS STEEL UNITS

SECTION STEAM CONDENSATE PUMPS

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

380 Series Multi-Stage Centrifugal Pumps

Wilo IL Vertical Split-Coupled Inline Pumps

SHURFLO 316 STAINLESS STEEL CLOSE-COUPLED SELF-PRIMING FLEXIBLE IMPELLER PUMPS OPERATION INSTRUCTIONS, PERFORMANCE, SPECIFICATIONS & PARTS MANUAL

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y LS BARGE PUMP. Vertical high-flow pump

Horizontal Split Case Pumps Type U

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

MAGNETIC DRIVE PUMPS AMERICA S MOST VERSATILE LINE OF CENTRIFUGAL PUMPS THINK QUALITY...THINK DELIVERY...THINK PRICE

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

Series SR Compact Centrifugal Mag-Drive Pumps. WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec

Goulds 3600 Between-Bearing, Axially-Split, Multistage Pumps

Goulds 3600 Between-Bearing, Axially-Split, Multi-Stage Pumps. Goulds Pumps

KV Vertical Inline Pumps Taco Vertical Inline Pumps meet the latest standards for hydraulic performance and dimensional

Family Curve. Submersible Grinder Pumps 1¼" and 2" Discharge. Effluent/Grinder Pumps.

TYPE LF/LC/LCV END SUCTION PUMPS

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

Types TMUB, TMUAH and. J Jockey Pumps

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. ASME/ANSI B73.1 Chemical Process Pump

FAN ENGINEERING. Sealing of Fan Housings

Goulds Large Capacity, Single Stage, Double Suction Pump

MSL A B A BK3 OS P AB

FAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS.

Vertical Heavy Duty Pumps

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power

Design and Construction Standards SECTION PLUMBING EQUIPMENT

TECHNICAL. Series 18. Pump Packages

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series

Action Electric Drum Pumps

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

Air Eliminator

PENGUIN SERIES HSC PUMPS INTRODUCTION

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

CAP SERIES SEWAGE AND WASTE WATER PUMPS

SERIES ES BASE MOUNTED TURBINE PUMPS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

References are in agreement with UMRL dated April 2018 **************************************************************************

SELF-PRIMING PUMPS CORNELL PUMP COMPANY STX & STL SERIES INDUSTRY LEADING EFFICIENCY WITH CYCLOSEAL SYSTEM EFFICIENT BY DESIGN FIVE-YEAR WARRANTY

DESCRIPTION MAINTENANCE INSTALLATION OF NEW SEAL REMOVAL OF OLD SHAFT SEAL

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

Transcription:

Centrifugal Pumps 2012-5 Page 1 Type 0800 INDEX D-800 Maximum Temperature Limitations 2,3 Maximum Suction Pressure Limitations 2 Maximum Working Pressure Limitations 3 General Information Size, Suction and Discharge 4 Maximum Working Pressure 4 Hydrotest Pressure 4 Casing Thickness 4 Casing / Impeller Hub Clearance 4 Materials of Construction 5 Bearing Frame Information-Dimension, Bearings 6 Shaft and Shaft Sleeve Dimensions 6 Bearings Frame Information - Dimensions, Bearings 6 Mechanical Seal Cover Dimensions 6 Mechanical Seal Information 7,8 Motor Selection and Specifications 9 Impeller Information 10 Noise Level Data 11 Kit Program 12 Specification Sheets 13-15 Sectional Drawings 16-20 ij Ingersoll-Dresser Pumps Chesapeake, VA

2012-5 Page 2 Type D800 Centrifugal Pump Temperature Limitations The maximum temperature of the liquid that can be pumped by a D-800 is dependent on the conduction of the heat along the pump / motor shaft to the bearings, design, and materials of the mechanical seal on the pump, and the characteristics of the fluid being pumped as it relates to the materials of construction. Temperature Limitations Pump Type D814 Frame Mounted D824 Close Coupled D834 Close Coupled Vertical Line Crane Mechanical Seal Material Code BF 50 171 BF 50 10 101* XF 50 171 XF 50 10 10 1* BF 90 1 F 90 1 0 28 P 66 171 Pump Fittings Temperature Limit - F Maximum Minimum All 225-20 All 250-20 All All 225 250-20 -20 *Stationary Seat is ceramic and subject to thermal shock. Maximum Suction Pressure -75 PSI Maximum Suction Pressure Limitations Caution: The sum of suction pressure and maximum head developed by the pump at shutoff should never exceed the maximum allowable working pressure of the pump at rated temperature. Refer to section 2012-3, page 3 for maximum allowable working pressure. I Ingersoll-Dresser Pumps Chesapeake, VA

Centrifugal Pumps 2012-5 Page 3 Type D800 Maximum Working Pressure Limitations The maximum working pressure of any pump is determined by the physical strength of the casing material, the casing thickness, and the casing bolting and gasketing. The D-800 iron casing material is the primary factor limiting working pressure. Working pressure also varies with pumping temperature. The chart below indicates this variation. 220 C3 cf) 200 MAX IMUM CASE W ORK ING PRESSU R F 180 160 140 120 1 00 80 60 40 20 10" PUMPS EXCEPT 6X4X10 9" PUMPS 4,5,6,8,11 84 6X4X10 PUMPS 15 PUMPS 12' PUMPS Protect pump from freezing Dotte d line for hot oils and non water pont( ining liquids Limit s for liquids cont( ining water 0 --50 0 50 100 150 200 250 300 350 TEMPERATURE DEGREES FAHRENHEIT 1-50 50 100 150 TEMPERATURE - DEGREES CELSIUS NOTE: Final selections must be made based on mechanical seal limits given in General Data Section S<204361 B ij Ingersoll-Dresser Pumps Chesapeake, VA

2012-5 Page 4 Type D800 Centrifugal Pump End Suction Pump Size 0814, D824 Suction Size (In.) Discharge Size (In.) Maximum Working Pressure (PSI) Hydrotest Pressure (PSI) Minimum Casing Thickness (In) Casing / Impeller Hub Clearance (In.) 2 1/2x2%x4T 2% 2% 175 265 0.25.012-.017 3x3x4F 3 3 175 265 0.25.018-.022 2%xl xl %x5t 2% 1% 175 265 0.25.012-.017 3x1 1/2x5F 3 1% 175 265 0.25.018-.024 3x2x5F 3 2 175 265 0.25.012-.017 3x2x5T 3 2 175 265 0.25.012-.017 4x3x5F 4 3 175 265 0.30.021-.025 1%xl x6t 1% 175 265 0.30.010-.015 1 1/2x1x6F 1% 175 265 0.30.018-.024 2x1x6T 2 175 265 0.30.010-.015 2 1/2x1%x6T 2% 175 265 0.30.012-.017 3x1%x6F 3 175 265 0.30.018-.024 3x2x6F 3 175 265 0.30.018-.024 3x2x6T 3 175 265 0.30.012-.017 4x3x6F 4 175 265 0.35.021-.027 6x4x6F 6 175 265 0.35.021-.027 1%xl x8f 1% 1 175 265 0.28.018-.024 2x1x8T 2 1 175 265 0.30.010-.015 2%xl %x8t 2% 1% 175 265 0.30.012-.017 3x1%x8F 3 1% 175 265 0.30.018-.024 3x2x8F 3 2 175 265 0.30.018-.024 3x2x8T 3 2 175 265 0.30.012-.017 4x3x8F 4 3 175 265 0.35.021-.027 6x4x8F 6 4 175 265 0.38.021-.027 2%xl %x9f 2 1% 200 300 0.44.010-.017 3x2x9F 3 2 200 300 0.44.010-.017 4x3x9F 4 3 200 300 0.47.010-.017 2x1x1OF 2 1 220 330 0.35.012-.017 3x1%xl OF 3 1% 220 330 0.35.012-.017 3x2x1OF 3 2 220 330 0.35.010-.017 4x3x1OF 4 3 220 330 0.35.021-.027 6x4x1OF 6 4 175 265 0.47.021-.027 6x4x11F 6 4 175 265 0.51.021-.027 5x4x12F 5 4 125 185 0.50.010-.017 6x5x12F 6 5 125 185 0.53.010-.017 3x1%xl 3F 3 1% 175 265 0.55.018-.024 3x2x13F 3 2 175 265 0.55.018-.024 4x3x13F 4 3 175 265 0.55.021-.027 6x4x13F 6 4 175 265 0.51.028-.032 5x4x15F 5 4 150 225 0.56.010-.017 6x5x15F 6 5 150 225 0.63.010-.017 D834 2x2x5 2 2 175 265 0.24.012-.017 3x3x5 3 3 175 265 0.28.012-.017 3x3x5A 3 3 175 265 0.31.021-.027 1 1/2x1%x6 1% 1% 175 265 0.24.010-.015 2x2x6 2 2 175 265 0.28.012-.017 3x3x6 3 3 175 265 0.30.012-.017 3x3x6A 3 3 175 265 0.35.021-.027 1%x1 1/2x8 1% 1% 175 265 0.28.010-.015 2x2x8 2 2 175 265 0.30.012-.017 3x3x8 3 3 175 265 0.31.012-.017 3x3x8A 3 3 175 265 0.35.021-.027,-- v- - =5",',.4' N C\I C'') :1" Ingersoll-Dresser Pumps Chesapeake, VA

Centrifugal Pumps 2012-5 Page 5 Type D800 Standard Materials of Construction Standard Fitted All Iron Fitted Part D-814 I D-824 D-834 D-814 0-824 D-834 Casing Cast Iron 25 1 Casing Wear Ring Bronze (optional) 2 I Bronze I Steel (bar) (optional) 3 I Cast Iron Casing Gasket Synthetic Fibers with Nitrile Binder Impeller Silicon Brass I Cast Iron - 25 Adapter Cast Iron - 25 Adapter Wear Ring Bronze Cast Iron Shaft Sleeve Bronze 416 SS Casing and Adapter Cap Screws Steel (Bolts) Shaft and Key Steel Bar Impeller and Washer 316 SS Impeller Washer Gasket Synthetic Fibers with Nitrile Binder Impeller Screw 304 SS Casing Foot 4 Ductile Iron N/A Steel Ductile Iron N/A Steel Optional (optional) Bearing Frame Cast Iron N/A N/A Cast Iron N/A N/A Bearing Frame Foot Steel (plate) N/A N/A Steel (plate) N/A N/A Mechanical Seal Crane 21 or Equal, Carbon VS Ni-Resist Faces, Buna-N Bellows, 18-8 SS Metal Parts Note: Footnotes apply to these sizes only: 2 1/2x1 1/2x9, 3x2x9, 4x3x9, 5x4x12, 6x5x12 5x4x15, 6x5x15. 1 Casing Iron - 30 2 Bronze wear ring supplied as standard. 3 Iron Wear ring supplied as standard. 4 Casing foot is an integral part of the casing Material S ecifications General Description Specification General Description Specification Cast Iron - 25 ASTM A278 Class 25 Steel (Plate) ASTM A36 Cast Iron - 30 ASTM A278 Class 301 416 SS AISI 304 / ASTM A582 Bronze Alloy C93200 2 304 SS AISI 304 Silicon Brass ASTM B584 Alloy C87500i 316 SS AISI 316 Steel (Bar) ASTM A576 4 Ductile Iron ASTM A536 Grade 60-40-18 Steel (Bolts) SAE Grade 2 b Note: Footnotes apply to these sizes only: 21/2x1Y2x9, 3x2x9, 4x3x9, 5x4x12, 6x5x12, 5x4x15, 6x5x15. 1 ASTM A48 Class 30B 2 Alloy CA932 3 ASTM B176 Alloy 878 4 Shaft material id AISI 1045 5 SAE Grade 8 Ingersoll-Dresser Pumps Chesapeake, VA

2012-5 Page 6 Type 0800 Centrifugal Pump Frame Impeller At Impeller Frame Mounted D-814: Bearing Frame Information Shaft Diameter Under Between At O.D. of Impeller Sleeve Bearings Coupling Sleeve Overhang Size of Keyway at Coupling Bearing Span Bearing Line A 7/8 1 1 1/2 1 1 3/8 1/4 x 1/4 5 1/4 6 SKF 6306-2R5 Symbols Thrust NDH Z499606 B 1 1/4 1 3/8 2 1/4 1 1/8 1 3/4 1/4 x 1/4 6 7/8 7 6309-2RS Z499609 C 1 1/2 1 5/8 2 3/16 1 7/8 1 7/8 1/2 x 1/2 9 1/8 9 6210 6210 Close Coupled D-824/D-834 Shaft and Shaft Sleeve Dimensions Shaft Diameter Pump Model Motor Frame 0. D. Of Sleeve At Impeller Under Sleeve 143-215 JM 7/8 1 1 3/8 D-824 254-326 JM 1 1/4 1 3/8 1 3/4 364-365 JP 1 5/8 1 3/4 2 1/8 284-365 AJ 1 1 1/2 1 5/8 1 7/8 (1) Contact factory for any other dimensional information Frame Size Maximum Allowable Shaft Brake Horsepower RPM 3500 2900 1750 1450 1150 A 50 41 25 21 16 B 110 91 55 45 36 c 165 135 55 FR A CB x Y A 1 3/8 2 1 9/16 3/8 B 1 3/4 2 1/2 1 7/8 7/16 C 1 7/8 2 5/8 2 7/16 MP. END A C MTR A CB x Y 143-215 JM 1 3/8 2 1 9/16 3/8 254-326 JM 1 3/4 2 1/2 1 7/8 7/16 364-365 JP 2 1/8 3 2 1/4 1/2 284-365 AJ 1 7/8 2 5/8 2 7/16 IJ Ingersoll-Dresser Pumps Chesapeake, VA

Centrifugal Pumps 2012-5 Page 7 Type 0800 Mechanical Seals SEAT SNAP RING ==414442 SLEEVE MECHANICAL SEAL RW-177898 Operations of Mechanical Seal (Typical Crane Type 21) The rotating "seal head" is factory assembled as a single unit. It consists of a flexible synthetic rubber bellows, lapped sealing washer, retainer, driving band, land disk. The rotating sealing washer mates with a stationary floating seat. Both faces are precision lapped to prevent leakage and to eliminate break-in-runs. Positive drive within the seal head is achieved by preloading the driving (left) end of the rubber bellows against the shaft by means of a metal band so that it will rotate within the shaft. Drive is achieved by means of projections on the metals driving bank that engage slots in the retainer shell. This retainer shell in turn drives the sealing washer by means of interlocking notches. Spring pressure is transmitted to he sealing washer through the retainer, disk, and bellows flange. Accordion action of the bellows allows the seal head and washer to move freely, so that constant contact with the seat face is maintained at all times. The rotating seat is held by a synthetic rubber sealing ring, which eliminates stress distortion of the lapped face during installation and operation. Nomenclature: Crane Packing Company has a 5 letter code describing materials in their mechanical seals. Each digit describes: First - Shaft Packing Second - Rotor Facing Material Third - Rotor metal parts Fourth - Stationary Seat Material Fifth - Spring Material Optional Mechanical Seals D-800 mechanic seal covers will accommodate a great variety of mechanical seal designs from various suppliers. Please contact Chesapeake Marketing for details. 111 Ingersoll-Dresser Pumps Chesapeake, VA

2012-5 Page 8 Type D800 Centrifugal Pump Mechanical Seal Application Information Below is a list of chemicals that can be handled by the stock Crane Type 21 seals. For liquids not covered, refer to Chesapeake Marketing. Please be prepared with complete details as to COS, temperature, specific gravity, suction pressure, and complete identification of the fluid pumped. BP1C1, XP1C1, BP171, and XP171 type 21 stock seals can be applied in the following fluids, with the exceptions noted. Liquids Comments Liquids Comments Alcohol, Ethyl Alcohol, Methyl Alum Solution Aluminum Hydroxide Ammonium Carbonate Antifreeze, Water, Alcohols or Glycols Aromatic Fuels Beer Borx Solution Boric Acid Brine,Calcium Chloride Brine, Sodium Chloride Butyl Alcohol Cane Sugar Liquors and Cane Juice Carbonic Acid Citric Acid Solutions Cottonseed Oil Diesel Fuel Diethylene Glycol Ethylene Glycol Formaldehyde or Formalin Fuel (Jet) JP4-5 - 6 Gas Oil Gasoline Gasoline (Aromatic) Gasoline (Automotive Grades) Gasoline (Bronze) Gasoline (Ethyle) Gasoline (100 Octane) Gasoline (130 Octane) Gasoline (High Test) Gasoline with H2S Glycerine or Clycerol Insecticid6s Kerosene Malt Beverages Methyl Alcohol Mineral Spirits Naptha Naptha, Sour Gasoline (Trace H2S) Naptha, VMP XP1C1 XP1C1 Viton Only XP1C1 XP1C1 or BP1C1 XP1C1 XP1C1 XP1C1 Viton Only Oil, Air Corps Hydraulic Oil, Crude (Paraffin Base) Oil, Crude (Sweet) Oil, Cutting Soluble Oil, Diesel Oil, Domestic Fuel Oil, Fuel and Gas Oil, Hydraulic Oil, Hydraulic Mineral Base Oil, Kerosene Oil, Linseed Oil, Lubricating Oil, Mineral Oil, Mineral Seal Oil, Nut Oil, Palm Oil, Paraffin Base Oil, Peanut Oil, Quenching Oil, Soy Bean Oil, Vegetable Oil and Ammonia Pentane Petroleum Products Propane Propylene Propulene Glycol Stoddard Solvent Sulphonated Fatty Alcohol Sulphonated Vegetable Oils Tallow Turpentinte Vegetables, Oils Condensate Cooling Tower Water Water, Soapy With Soluble Oil Whiskey Wine Ni-Resist Seats Preferred Viton Only Viton Only. Nomenclature: Crane Packing Company has a 5-letter code describing materials in their mechanical seals. Each digit describes: First - Shaft Packing Fourth-Stationary Seat Material Second-Rotor Facing Material Fifth- Spring Material Third-Rotor metal parts Ingersoll-Dresser Pumps Chesapeake, VA

Centrifugal Pumps 2012-5 Page 9 Type 0800 General Application Information When selecting a motor the location of the pump should always be considered to insure the proper motor enclosure for the operating environment. The following enclosures are available: 1. Open Dripproof (ODP) - This enclosure is the most widely used. It is suitable for general purpose application where normal atmospheric conditions prevail. Motor frame construction and insulation protect against drips, normal dampness, and humid atmosphere. Excessive moisture or humidity require an alternate motor enclosure. 2. Totally Enclosed Fan-Cooled (TEFC) - This enclosure is primarily a chemical duty enclosure. It is recommended when the surrounding air contains light dust, metallic particles, steam, excessive dampness or humidity, and corrosive gases or fumes. Cooling is provided by means of a fan integral with the motor but external to the enclosing part. This enclosure is not suitable if particles in the surrounding air are heavy or sticky, and can clog ventilating air passages. In this case, a totally enclosed nonventilated (TENV) motor should be used. Note that, in most cases, the fractional motors are TENV as standard instead of TEFC. 3. Explosion proof, Class 1, Group D - This enclosure is recommended for particularly hazardous locations, including gasoline and petroleum handling and storage plants, dry cleaning and dyeing plants, paint and varnish factories, gas and chemical plants, etc., where the gas involved is no more dangerous than high test gasoline or lacquer solvent vapors. The enclosure is not suitable for more hazardous gases classified as group A, group B, group C. Specialized motor enclosures are available from various motor vendors. Refer to Chesapeake Marketing for any special motor requirements. Close Coupled Motors 1. Close-coupled motors offered are standard NEMA "C" face motors, which conform to the joint NEMA- Hydraulic Institute standard and which are readily available from most major motor manufacturers. The shaft extensions, "C" face and shield, and all foot dimensions are in complete conformance with NEMA standards. 2. All D-824 close-coupled pumps, with two exceptions, use the JM motor shaft extensioin. The D-824 size 4x3x9 also offers a 364-365 P for higher horsepower requirements. The D-824 15-inch pumps are only offered with AJ motor frames, which have an IDP proprietary shaft. 3. All D-834 vertical in-line pumps use the same motor designated JMV for vertical mounting. JMV are without feet and use a canopy cap. Ingersoll-Dresser Pumps Chesapeake, VA

2012-5 Page 10 Type 0800 Centrifugal Pump Pump Size D814, 0824 Min Dia (In.) Im eller Information Max. Eye Dia Area (In.) (In.2) Max Dia (Solids) (In.) No. Vanes WR2 (Lb.- ln.2) 2 1/2x2 1/2,x4T 3.4 4.2 5.50 0.38 7 10 3x3x4F 3.4 4.2 5.50 0.38 7 10 2 1/2x1Y2x5T 4.4 5.2 4.91 0.42 6 18 3x1 1/2x5F 4.4 5.2 4.91 0.42 6 18 3x2x5F 4.4 5.2 6.50 0.50 6 20 3x2x51 4.4 5.2 6.50 0.50 6 20 4x3x5F 4.4 5.2 9.60 0.42 6 24 1 1/2x1x6T 5.3 6.5 1.80 0.25 5 23 1 1/2x1x6F 5.3 6.5 3.10 0.38 5 25 2x1x6T 5.3 6.5 3.10 0.38 5 25 2 1/2x1 1/2x6T 5.3 6.5 5.30 0.42 6 28 3x1Y2x6F 5.3 6.5 5.30 0.42 6 28 3x2x6F 5.3 6.5 6.88 0.59 5 36 3x2x6T 5.3 6.5 6.88 0.59 5 36 4x3x6F 5.3 6.5 9.60 0.53 6 44 6x4x6F 5.3 6.5 17.70 0.62 7 67 1 1/2x1x8F 6.8 8.0 3.10 0.31 5 60 2x1x8T 6.8 8.0 3.10 0.31 5 60 2 1/2x1Y2x8T 6.8 8.0 4.91 0.44 6 58 3x1 1/2x8F 6.8 8.0 4.91 0.44 6 58 3x2x8F 6.8 8.0 7.07 0.59 5 65 3x2x8T 6.8 8.0 7.07 0.59 5 65 4x3x8F 6.8 8.0 10.00 0.63 6 80 6x4x8F 6.8 8.0 19.60 0.63 6 140 2Y2x1 1/2x9F 6.5 9.4 3.14 0.31 4 216 3x2x8F 5.5 9.4 7.10 0.50 5 245 4x3x9F 6.5 9.4 12.56 0.69 5 274 2x1x1OF 8.3 9.9 4.90 0.44 6 168 3x1 1/2x1OF 8.3 9.9 4.90 0.44 6 168 3x2x1OF 8.3 9.9 7.10 0.59 5 150 4x3x1OF 8.3 9.9 9.60 0.63 6 165 6x4x1OF 8.3 9.9 19.60 0.55 7 200 6x4x11F 8.3 9.9 19.60 0.80 7 260 5x4x12F 8.5 12.25 19.60 1.00 7 778 6x5x12F 9.0 12.25 28.20 1.38 7 806 3x1 1/2x13F 10.5 12.6 7.10 0.55 5 195 3x2x13F 10.5 12.6 7.40 0.70 5 225 4x3x13F 10.5 12.6 10.80 0.90 6 295 6x4x13F 10.5 11.8 19.70 0.88 7 460 5x4x15F 10.0 15.2 19.60 0.88 5 1123 6x4x15F 10.0 15.2 28.20 1.13 6 1152 D834 2x2x5 4.4 5.2 4.9.42 6 18 3x3x5 4.4 5.2 6.2.50 6 20 3x3x5A 4.4 5.2 9.6.42 6 24 1 1/2x1 1/2x6 5.3 6.5 3.1.38 5 25 2x2x6 5.3 6.5 5.3.42 6 28 3x3x6 5.3 6.5 6.9.59 5 36 3x3x6A 5.3 6.5 9.6.53 6 44 1Y2x1 1/2x8 6.8 8.0 3.1.31 5 60 2x2x8 6.8 8.0 4.9.44 6 58 3x3x8 6.8 8.0 7.1.59 5 65 3x3x8A 6.8 8.0 10.0.63 6 80 Ingersoll-Dresser Pumps Chesapeake, VA

Centrifugal Pumps 2012-5 Page 11 Type D800 0-814 Bare Pump Noise Level Information Below is a tabulation of sound pressure readings for frame mounted D-814 pumps for general information and not the be subject to guarantee by!dp. Test were conducted in accordance with the Standards of the Hydraulic Institute, 13th Edition, 1975. Pumps were tested in a spacious room (simulating an open filed) with driver covered by a sound absorbing enclosure and with system valves, venturi's, and tanks behind a sound absorbing wall. Decibel readings do not include driver or system noise. Pumps were tested through a normal operating range of about 75% to 125% of the best efficiency point at all impeller diameters. Note: 9-inch, 12-inch, and 15-inch pumps have not been tested. These figures should be used as estimates only. Pump Size For Information Only Not subject to Guarantee dba ciba @3550 RPM @ 1770 RPM 2 1/2x2 1/2x4T 70-3x3x4F 70-2"1/2x1 1/2x5T 70 60 3x1Y2x5F 70 60 3x2x5F 70 60 3x2x51 70 60 4x3x5F 70 60 1 lax1x6t 70 60 1 1/2x1x6F 70 60 2x1x6T 70 60 2 1/2x11/2x6T 70 60 3x11/2x6F 70 60 3x2x6F 72 60 3x2x6T 72 60 4x3x6F 75 60 6x4x6F 80 62 1 1/2x1x8F 75 60 2x1x8T 75 60 2 1/2x1Y2x8T 75 60 3x1Y2x8F 75 60 3x2x8F 75 60 3x2x8T 75 60 4x3x8F 77 62 6x4x8F 79 64 2x1 1/2x9F 80 70 3x2x9F 80 70 4x3x9F 80 70 2x1x1OF 77 67 3x1Y2x1OF 79 70 3x2x1OF 80 70 4x3x1OF 81 70 6x4x1OF - 70 6x4x11F - 72 5x4x12F - 75 6x5x12F - 75 3x1 1Ax13F - 70 3x2x13F - 70 4x3x13F - 72 6x4x13F - 75 5x4x15F - 80 6x4x15F - 80 Ingersoll-Dresser Pumps Chesapeake, VA

2012-5 Page 12 Type 0800 Centrifugal Pump Kit Program Description M 01--1612- PAitrA 041-7-7C_A-L 7-A1-41,6" AdC CAP SCREW--... IMOTOR) ADAPTER \ R N ADAPT ER G SLEEVE \ SEAT SEAL IMPELLER WASHER GASKET \ I - j- SNAP RING. SHAFT SLEEVE GASKET IMPELLER RW-183055 Kit includes Casing Wear Ring, Casing Gasket, Cap Screws, Packaged. IMPELLER..., WASHER L. IMPELLER SCREW GASKET IMPELLER /11 SCREW clii RW-177898 Includes parts listed above completely packaged. Available: Standard fitted or all iron accessories include any price book mechanical seal. rmium, a4ote r eiva CtLenati C4S,14 Kit consists of a fully assembled bearing frame completely packaged. RW-177898 Kit consists of a casing, casing gasket, cap screws. TO BUILD A COMPLETE PUMP: D-814 Frame Mounted - Frame and Casing Kit and Major Parts Kit. D-834, D-824 Close Coupled - Casing Kit and Major Parts Kit and Nema JM Motor. Ingersoll-Dresser Pumps Chesapeake, VA

Centrifugal Pumps 2012-5 Page 13 Type D800 D814 Single Stage, End Suction, Vertically Split Case Centrifugal Pump 1. General Furnish and install an Ingersoll-Dresser D-814 centrifugal pump for (type) service. The pump is to be cast iron construction with (bronze) (iron) (ss steel) impellers and is to be mounted on a (steel) baseplate extending under pump and (type) drive. The pump is to be coupled to the driver by means of an approved spacer-type coupling and protected by a coupling guard. 2. Operating Condition Each pump shall be capable of delivering GPM of (liquid) against feet total head. Net positive suction head available to the top of the pump foundation will be feet. The characteristics of the liquid to the pumped are as follows: Liquids Handled: Temperature: Specific Gravity: Nature of Solids Present: Percentage of Solids by Weight: Viscosity of Liquid at Pump Temperature: (Add any additional facts concerning the nature of the liquid that might affect pump construction or application.) 3. Construction Details Casing The casing shall be close grained cast iron and self venting top centerline discharge design. The casing shall be designed to permit disassembly from the rear to remove pump internals without disturbing system piping, and be supported by casing feet. A dual volute design is used on some larger sizes to reduce radial loads. Drain connections shall be supplied. Casing Nozzles Flanged and threaded casing nozzles shall conform to ANSI B16.1 specification with minimum 125 PSI rating. All flanged connections shall be flat face. Stuffing Box The stuffing box shall be one piece integral with the adapter and designed as an open seal chamber to allow maximum flushing action at the mechanical seal faces. The mechanical seal chamber shall be vented to suction pressure and sealed from discharge pressure by a replaceable wear ring. Mechanical Seal The mechanical seal shall be bellows - non-pusher type secured and positioned by a snap ring to simplify mechanical seal setting procedures. Mechanical seal rotating parts shall be stainless steel with carbon versus Ni- Resist faces and Buna- N Bellows. The mechanical seal set shall be flexibly mounted with a Viton 0 Ring. Impellers The impellers shall be of the enclosed design, statically and hydraulically balanced. The impeller shall be securely positioned on the shaft by means of an impeller key. Balance holes shall be provided through the impeller hub to minimize axial thrust loads and keep stuffing box pressures to a minimum. Shaft The pump shaft shall be high strength carbon steel sized to provide a minimum of shaft deflection. The shaft shall be designed to accommodate a replaceable shaft sleeve in the stuffing box area. Shaft Sleeve The shaft sleeve shall be fully machined and extend beyond the stuffing box. Sleeve thickness shall be no less the 3/16 inches. The sleeve shall be gasketed to prevent leakage or pumping liquid onto the shaft, and positively driven by the impeller key. Casing/ Adapter Joint The casing gasket shall be confined and positioned to protect the precise adapter to the casing registered fit and prevent pumping liquid from entering this area, corroding surfaces, and impeding the disassembly of the pump after it has been in service. Bearings The bearings shall be supported by two antifriction ball bearings located in the pump bearing frame, and of sufficient size and design to provide a two-year minimum life. Both bearings shall be sealed-for-life type, which will not require relubrication and will be adequately protected from entrance of contaminated material while operating. Baseplates The baseplates shall be of (channel steel) (fabricated with drip lip) sufficiently designed to support the pump and the driving motor. On larger sized pumps, a fabricated baseplate is the only option. Couplings The couplings shall be of the flexible spacer type to allow removal of pump internals without disconnecting motor leads or system piping. Ingersoll-Dresser Pumps Chesapeake, VA

2012-5 Page 14 Type 0800 Centrifugal Pump 1. General D824 Single Stage, End Suction, Vertically Split Case Close-Coupled Centrifugal Pump Furnish and install an Ingersoll-Dresser D-824 centrifugal pump for (type) service. The pump is to be cast iron construction, (bronze) (iron) (ss steel) fitted, and are to be close coupled to a standard NEMA C-face motor driver (JM pump shaft with two exceptions; 4x3x9 pump offers a JP shaft option, 15" pumps come with an AJ motor shaft only). 2. Operating Conditions Each pump shall be capable of delivering GPM of (liquid) against feet total head. Net positive suction ahead available to the top of the pump foundation will be feet. The characteristics of the liquid to the pumps are as follows: Liquid Handled: Temperature: Specific Gravity: Nature of Solids Present: Percentage of Weight: Viscosity of Liquid at Pumping Temperature: (Add any additional facts concerning the nature of the liquid that might affect pump construction or application.) 3. Construction Details Casing The casing shall be close grained cast iron and self venting top centerline discharge design. The casing shall be designed to permit disassembly from the rear to remove pump internals without disturbing system piping, and be provided with tap and plug holes for drain connections. Casing Nozzles Flanged and threaded casing nozzles shall conform to ANSI B16.1 specifications with a minimum 125 PSI rating. All flanged connections shall be flat face. Stuffing Box The stuffing box shall be as one piece integral with the adapter, and designed as an open seal chamber to allow maximum flushing action at the mechanical seal faces. The mechanical seal chamber shall be vented to suction pressure and sealed from discharge pressure by a replaceable wear ring. Mechanical Seal The mechanical seal shall be bellow- non-pusher type secured and positioned by a snap ring to simplify mechanical seal setting procedures. Mechanical seal rotating parts shall be stainless steel with carbon versus Ni- Resist faces and Buna-N bellows. The mechanical seal seat shall be flexibly mounted with a Viton 0 ring.. Impellers The impellers shall be of the enclosed design, statically and hydraulically balanced. The impeller shall be securely positioned on the shaft by means of an impeller key. Balance holes shall be provided through the impeller hub to minimize axial thrust loads and keep stuffing box pressures to a minimum. Shaft The pump shaft shall be high strength carbon steel sized to provide a minimum of shaft deflection. The shaft shall be designed to accommodate a replaceable shaft sleeve in the stuffing box area. Shaft Sleeve The shaft sleeve shall be fully machined and extend beyond the stuffing box. Sleeve thickness shall be no less the 3/16 inches. The sleeve shall be gasketed to prevent leakage or pumping liquid onto the shaft and positively driven by the impeller key. Casing/ Adapter Joint The casing gasket shall be confined and positioned to protect the precise adapter to the casing registered fit and prevent pumping liquid from entering this area, corroding surfaces, and impeding the disassembly of the pump after it has been in service. Motors The pump shall be supplied with a standard NEMA C-face motor with JM shaft extension on 6-inch, 8-inch, 9-inch, 10-inch, 11-inch, 12-inch and 13-inch. Pump shall be supplied with a proprietary motor (AJ Frame from IDP for 15" size pumps. The 4x3x9 pump size is also offered with a JP shaft extension). I Ingersoll-Dresser Pumps Chesapeake, VA

Centrifugal Pumps 2012-5 Page 15 Type D800 D834 Singe Stage Vertical Inline Close Coupled Centrifugal Pump 1. General Furnish and install an Ingersoll-Dresser D-834 centrifugal pump for (type) service. The pumps are to be close coupled to a NEMA-C face motor (JMV shaft). The design shall allow for the disassembly if pump internals without disturbing piping. 2. Operating Conditions Each pump shall be capable of delivering GPM of (liquid) against feet total head. Net positive suction head available to the top of the pump foundation will be feet. The characteristics of the liquid to be pumped are as follows: Liquid Handled: Temperature: Specific Gravity: Nature of Solids by Present: Percentage of Solids by Weight: Viscosity of Liquid at Pumping Temperature: (Add any additional facts concerning the nature of the liquid that might affect pump construction or application.) 3. Construction Details Casing The casing shall be close grained cast iron with wall thickness suitable for continuous industrial duty. A drain connection must be provided at the bottom of the casing. A replaceable wearing ring shall be provided. Casing Nozzles All casing nozzles are to be flanges and conform and ANSI B16.1 specifications with a minimum 125 PSI rating. Suction and discharge nozzles are to be positioned 180 degrees apart and located on a common centerline for mounting in a pipeline. Stuffing Box The stuffing box shall be as one piece integral with the adapter and designed as an open seal chamber to allow maximum flushing action at the mechanical seal faces. The mechanical seal chamber shall be vented to suction pressure and sealed from discharge pressure by replaceable wear ring. Mechanical Seal The mechanical seal shall be bellows-non-user type secured and positioned by a snap ring to simplify mechanical seal setting procedures. Mechanical seal rotating parts shall be stainless steel with carbon versus Ni-Resist faces and Buna-N bellows. The mechanical seal seat shall be flexibly mounted with a Viton 0 ring. Alternate mechanical seal materials shall be Impeller The impellers shall be of the enclosed design, statically and hydraulically balanced. The impeller shall be securely positioned on the shaft by means of an impeller key. Balance holes shall be provided through the impeller hub to minimize axial thrust loads and keep stuffing box pressures to a minimum. Impellers shall be industrial quality cast bronze or iron and not fabricated or tack welded Shaft The integral pump/motor shaft shall be high strength carbon steel sized to provide a minimum of shaft deflection. The shaft shall be a designed to accommodate a replaceable shaft sleeve in the stuffing box area. Shaft Sleeve The shaft sleeve shall be fully machined and extend beyond the stuffing box. Sleeve thickness shall be no less that 3/16 inches. The sleeve shall be gasketed to prevent leakage or pumping liquid onto the shaft and positively driven by the impeller key. Casing/ Adapter Joint The casing gasket shall be confined and positioned to protect the casing registered fit at the adapter/ casing joint from the liquid pumped to avoid corroded surfaces and impeding the disassembly of the pump after it has been in service. The casing gasket shall be confined to prevent blowout failure. Motors The pump shall be supplied with standard vertical NEMA-C face motor with a JMV shaft extension. Ingersoll-Dresser Pumps Chesapeake, VA

2012-5 Page 16 Centrifugal Pump OP TIONAL CASING RING Recm'd Spare Parts xx 00 0 x x 0 0 0 0x nom No. Name of Pert 1 Casing Ill Screw, Cap (Adapter to Casing) IF Screw, Cap (CSG Foot to Casing) 2 Impeller 6 Shaft 14 Sleeve, Shaft 16 Bearing, Line 18 Bearing, l'hrust 27 Ring, Adapter and Cover 32 Key, Impeller 37 Cover, Thrust Bearing 40 Deflector 45 Cap, Vent 46 Key, Coupling 53 Foot, Casing 65 Seat, Mechanical Seal 71 Adapter 80 Rotor, Mechanical Seal 91A Plug, Pipe-Casing Drain 99 Housing, Bearing 99C Screw, Cap (Adapter to Brg. Hsg.) 99D Screw, Cap (Thrust Brg. Cover to Brg. Hsg.) 212 Ring, Retaining 773 Gasket Kit 7 Ring, Casing (Optional) RW-180922 o These parts recommended as spare parts to be carried by user x Spare parts in addition to above export only I Ingersoll-Dresser Pumps Chesapeake, VA

1 Centrifugal Pumps 2012-5 Page 17 Type D800 MODEL D-814 (flanged) Flacm'd Spars Parts 1 X X 0 00 X X X A 0 0 0 0 )4 nom No. Nam of Part 1 Casing Ili Screw, Cap (Adapter to Casing) IF Screw, Cap (CSG Foot to Casing) 2 Impeller 6 Shaft 14 Sleeve, Shaft 16 Bearing, Line 18 Bearing, Thrust 27 Ring, Adapter and Cover 32 Key, Impeller 37 Cover, Thrust Bearing 40 Deflector 45 Cap, Vent 46 Key, Coupling 53 Foot, Casing 65 Seat, Mechanical Seal 71 Adapter 80 Rotor, Mechanical Seal 91A Plug, Pipe-Casing Drain 99 Housing, Bearing 99C Screw, Cap (Adapter to Brg. Hsg.) 99D Screw, Cap (Thrust Brg. Cover to Brg. Hsg.) 212 Ring, Retaining 773 Gasket Kit 7 Ring. Casing (Optional) RW 180924 o These parts recommended as spare parts to be carried by user x Spare parts in addition to above export only Ingersoll-Dresser Pumps Chesapeake, VA

2012-5 Page 18 Type D800 Centrifugal Pump MODEL 0-824 (flanged) OPTIONAL CASING RING RW-177896 PARTS LIST Reference No. Name of Part 1 Casing 2t Impeller 71A Adapter 27* Adapter Ring 14* Shaft Sleeve 7t Ring, Casing (Optional) Reference No. Name of Part 32 Impeller Key 40 Deflector 65 Mechanical Seal Seat 80 Mechanical Seal Rotor 212 Snap Ring 773* Gasket Kit I * Recommended spare parts for domestic use. -I- Recommended spare parts for export use, in addition to domestic requirements. Ingersoll-Dresser Pumps Chesapeake, VA

Centrifugal Pumps 2012-5 Page 19 Type D800 MODEL D-824 (threaded) RW-177894 Reference No. Name of Part 1 Casing 2t Impeller 71A Adapter 27* Adapter Ring 14* Shaft Sleeve 7t Ring, Casing (Optional) PARTS LIST Reference No. Name of Part 32 Impeller Key 40 Deflector 65 Mechanical Seal Seat 80 Mechanical Seal Rotor 212 Snap Ring 773* Gasket Kit * Recommended spare parts for domestic use. t Recommended spare parts for export use, in addition to domestic requirements. 14 Ingersoll-Dresser Pumps Chesapeake, VA

2012-5 Page 20 Type D800 Centrifugal Pump LIST OF PARTS MODEL D-834 Item No. Name of Part Item No. Name of Part 1 Casing 2 Impeller o 65 Seat (Mechanical Seal) 6 Shaft (an integral part of the 71 Adapter motor) o 773 Gasket Kit 7 Ring, Casing o 80 Rotor, Mech. Seal 14 Sleeve, Shaft o 212 Ring, Retaining (Mech. Seal Rotor) 91A Plug-drain 53 Optional Casing Support 27 Ring, Adapter and Cover 1F Cap Screw-Casing Support 40 Deflector 99G Cap Screw Motor 32 Key, Impeller 1E Cap Screw-Casing 91 Plug-Suction Vent o These parts recommended as spare parts to be carried by user. x Spare parts in addition to above for export only. I Ingersoll -Dresser Pumps Chesapeake, VA

New D-834 PUMPS 2012 -R5 Page 1 June 1989 PART NUMBER REFERENCE SECTION D-834 PUMPS Type D-834 CONTENTS Page 2012-R5 Page 2 D-834 Pump Liquid End Sectional and Material of Construction 3-5 D-834 Pump Liquid End Part Number Reference Section Dresser Pump, Dresser Industries, Inc., Chesapeake, VA

2012-R5 Page 2 June 1989 SECTIONAL D-834 LIQUID ENDS D-834 PUMPS New PART NUMBER REFERENCE SECTION STANDARD MATERIALS OF CONSTRUCTION Ref. No. NOMENCLATURE MATERIAL 1 Casing Cast Iron 2 Impeller Bronze/C.I. 6 Shaft (an integral part of the motor) 7 Ring, Casing Bronze/C.I. 14 Sleeve, Shaft Bronze/416 S.S. 26A Lockwasher, Impeller 316 S.S. 26 Screw, Impeller 304 S.S. 27 Ring, Adapter and Cover Bronze/C.I. 28 Gasket, Impeller Screw Nyltite 30A Gasket, Imp. Lockwasher ARAMID/NBR 32 Key, Impeller Carp 20 38 Gasket, Sleeve (Outer) ARAMID/NBR Ref. No. NOMENCLATURE MATERIAL 38A Ring '0', Shaft Sleeve Viton 65 Seat (Mechanical Seal) Niresist 71 Adapter Cast Iron 73 Gasket, Casing Hydroil 80 Rotor, Mech. Seal Carbon 212 Ring, Retaining (Mech. Seal) Stainless Steel 91A Plug-drain 53 Optional Casing Support Steel 1F Cap Screw-Casing Support Steel 40 Deflector 99G Cap Screw Motor Steel le Cap Screw-Casing Steel 91 Plug-Suction Vent 773 Gasket Kit (Ref. Nos. 26, 26A, 28, 30A, 38, 38A, 73) Dresser Pump Division, Dresser Industries, Inc., Chesapeake, VA Printed in U.S.A.

New D-834 2012-R5 Page 3 June 1989 PART NUMBER REFERENCE SECTION D-834 LIQUID ENDS REF. NO. - NOMENCLATURE MOTOR FRAME SIZE PUMP SIZE 2 x 2 x 5 3x3x5 3x3x5A 1.5x1.5x6 1 Casing with Ring All 983039-02 983040-02 983041-02 983042-02 le Screw, Cap Casing All 025684-00 025684-00 025684-00 025684-00 2 Impeller (Std.) 143-184 980903-75 980905-75 986709-75 980909-75 213-215 980903-75 980905-75 986709-75 980909-75 254-256 N/A N/A 980935-75 N/A 284-326 N/A N/A N/A N/A 2 Impeller (Iron) 143-184 953544-75 953550-75 954021-75 953540-75 213-215 953544-75 953550-75 954021-75 953540-75 254-256 N/A N/A 954022-75 N/A 284-326 N/A N/A N/A N/A 14A Assy, Sly. Consists of Ref. 14, 38, 38A, 212 Standard Fitted 143-215 959436-07 959436-07 959436-07 959436-07 254-326 N/A N/A 959437-07 N/A Iron Fitted 143-215 959436-06 959436-06 959436-06 959436-06 254-326 N/A N/A 959437-06 N/A. 14 Sleeve (Std.) 143-215 959436-05 959436-05 959436-05 959436-05 254-326 N/A N/A 959437-05 N/A Sleeve (Iron) 143-215 959436-00 959436-00 959436-00 959436-00 254-326 N/A N/A 959437-00 N/A 26 Screw, Imp. 143-215 809649-00 809649-00 809649-00 809649-00 254-326 N/A N/A 809885-00 N/A 26A Washer, Imp. 143-215 390416-00 390416-00 390416-00 390416-00 254-326 N/A N/A 390440-00 N/A 27 Ring Adp. (Std.) 143-215 959404-01 959405-01 959405-01 959406-01 254-326 N/A N/A 959405-01 N/A Ring Adp. (Iron) 143-215 959404-00 959405-00 959405-00 959406-00 254-326 N/A N/A 959405-00 N/A 28 Gskt, Scr, Imp. 143-215 P02736-00 P02736-00 P02736-00 P02736-00 254-326 N/A N/A P02737-00 N/A 30A Gskt, Imp, Wshr. 143-215 390036-10 390036-10 390036-10 390036-10 254-326 N/A N/A 390038-10 N/A 32 Key, Imp. 143-215 051106-00 051106-00 051106-00 051106-00 254-326 N/A N/A 020746-00 N/A 38 Gskt. Sly. Sft. 143-215 389013-10 389013-10 389013-10 389013-10 254-326 N/A N/A 389033-00 N/A 38A 0 Ring, Sly. Sft. 143-215 P02065-00 P02065-00 P02065-00 P02065-00 254-326 N/A N/A P02066-00 N/A 65 Seat, Mech. Seal 143-215 P02894-00 P02894-00 P02894-00 P02894-00 254-326 N/A N/A P02895-00 N/A 71 Adapter 143-184 959347-00 959347-00 959347-00 959350-00 213-215 959348-00 959348-00 959348-00 959351-00 254-256 N/A N/A 959349-00 N/A 284-326 N/A N/A N/A N/A 73 Gasket, Csg. 143-215 390006-10 390006-10 390006-10 390007-10 254-326 N/A N/A 390006-10 N/A 80 Rotor, Mech Seal 143-215 P02886-00 P02886-00 P02886-00 P02886-00 254-326 N/A N/A P02887-00 N/A 99G Screw Cap Motor All 025684-00 025684-00 025686-00 025686-00 212 Ring Seal Ret'r. 143-215 050502-00 050502-00 050502-00 050502-00 254-326 N/A N/A 050503-00 N/A 773 Gasket Kit 143-215 OGASKT-12 OGASKT-12 OGASKT-12 OGASKT-12 Ref. Nos. 26, 26A, 28, 30A 254-326 OGASKT-13 38, 38A, 73 7 Ring, Casing Std. All Iron Dresser Pump Division, Dresser Industries, Inc., Chesapeake, VA All 390496-00 390496-01 390497-00 390497-01 390012-05 390012-06 390495-00 390495-01

2012-R5 Page 4 June 1989 D-834 LIQUID ENDS D-834 New PART NUMBER REFERENCE SECTION REF. NO. NOMENCLATURE. MOTOR FRAME SIZE PUMP SIZE 2x2x6 3x3x6 3x3x6A 1.5x1.5x8 1 Casing with Ring All 983043-02 983044-02 983045-02 983046-02 le Screw, Cap Casing All 025684-00 025684-00 025684-00 025746-00 2 Impeller (Std.) 143-184 980911-75 980913-75 986713-75 980916-75 213-215 980911-75 980913-75 986713-75 980916-75 254-256 N/A 980914-75 986715-75 980942-75 284-326 N/A N/A 986715-75 N/A 2 Impeller (Iron) 143-184 953545-75 953551-75 953561-75 953541-75 213-215 953545-75 953551-75 953561-75 953541-75 254-256 N/A 953552-75 953562-75 953585-75 284-326 N/A N/A 953562-75 N/A 14A Assy, Sly. Consists of Ref. 14, 38, 38A, 212 Standard Fitted 143-215 959436-07 959436-07 959436-07 959436-07 254-326 N/A 959437-07 959437-07 959437-07 Iron Fitted 143-215 959436-06 959436-06 959436-06 959436-06 254-326 N/A 959437-06 959437-06 959437-06 14 Sleeve (Std.) 143-215 959436-05 959436-05 959436-05 959436-05 254-326 N/A 959437-05 959437-05 959437-05 Sleeve (Iron) 143-215 959436-00 959436-00 959436-00 959436-00 254-326 N/A 959437-00 959437-00 959437-00 26 Screw, Imp. 143-215 809649-00 809649-00 809649-00 809649-00 254-326 N/A 809885-00 809885-00 809885-00 26A Washer, Imp. 143-215 390416-00 390416-00 390416-00 390416-00 254-326 N/A 390440-00 390440-00 390440-00 27 Ring Adp. (Std.) 143-215 959407-01 959408-01 959409-04 959406-01 254-326 N/A 959408-01 959409-04 959406-01 Ring Adp. (Iron) 143-215 959407-00 959408-00 959409-03 959406-00 254-326 N/A 959408-00 959409-03 959406-00 28 Gskt, Scr, Imp. 143-215 P02736-00 P02736-00 P02736-00 P02736-00 254-326 N/A P02737-00 P02737-00 P02737-00 30A Gskt, Imp, Wshr. 143-215 390036-10 390036-10 390036-10 390036-10 254-326 N/A 390038-10 390038-10 390038-10 32 Key, Imp. 143-215 051106-00 051106-00 051106-00 051106-00 254-326 N/A 020746-00 020746-00 020746-00 38 Gskt. Sly. Sft. 143-215 389013-10 389013-10 389013-10 389013-10 254-326 N/A 389033-00 389033-00 389033-00 38A 0 Ring, SIY. Sft. 143-215 P02065-00 P02065-00 P02065-00 P02065-00 254-326 N/A P02066-00 P02066-00 P02066-00 65 Seat, Mech. Seal 143-215 P02894-00 P02894-00 P02894-00 P02894-00 254-326 N/A P02895-00 P02895-00 P02895-00 71 Adapter 143-184 959350-00 959350-00 959350-00 959354-00 213-215 959351-00 959351-00 959351-00 959355-00 254-256 N/A 959352-00 959352-00 959356-00 284-326 N/A N/A 959353-00 N/A 73 Gasket, Csg. 143-215 390007-10 390007-10 390007-10 390008-10 254-326 N/A 390007-10 390007-10 390008-10 80 Rotor, Mech Seal 143-215 P02886-00 P02886-00 P02886-00 P02886-00 254-326 N/A P02887-00 P02887-00 P02887-00 99G Screw Cap Motor All 025686-00 025686-00 025686-00 025748-00 212 Ring Seal Ret'r. 143-215 050502-00 050502-00 050502-00 050502-00 254-326 N/A 050503-00 050503-00 050503-00 773 Gasket Kit 143-215 OGASKT-12 OGASKT-12 OGASKT-12 OGASKT-12 Ref. Nos. 26, 26A, 28, 30A, 254-326 OGASKT-13 OGASKT-13 OGASKT-13 38, 38A, 73 7 Ring, Casing I Std. I All Iron All 390496-00 390496-01 390497-00 390497-01 390012-05 390012-06 390495-00 390495-00 Dresser Pump Division, Dresser Industries, Inc., Chesapeake, VA Printed in U.S.A

New D-834 2012-R5 Page 5 June 1989 PART NUMBER REFERENCE SECTION D-834 LIQUID ENDS REF. NO. NOMENCLATURE MOTOR FRAME SIZE PUMP SIZE 2x2x8 3x3x8 3x3x8A 1 Casing with Ring Al I 983047-02 983048-02 983049-02 le Screw, Cap Casing Al I 025746-00 025746-00 025746-00 2 Impeller (Std.) 143-184 980918-75 980920-75 986717-75 213-215 980918-75 980920-75 986717-75 254-256 980943-75 980921-75 980929-75 284-326 N/A 980921-75 980929-75 2 Impeller (Iron) 143-184 953546-75 953553-75 953563-75 213-215 953546-75 953553-75 953563-75 254-256 953547-75 953554-75 953564-75 284-326 N/A 953554-75 953564-75 14A Assy, Sly. Consists of Ref. 14, 38, 38A, 212 Standard F itted 143-215 959436-07 959436-07 959436-07 254-326 959437-07 959437-07 959437-07 I ron F itted 143-215 959436-06 959436-06 959436-06 254-326 959437-06 959437-06 959437-06 14 Sleeve (Std.) 143-215 959436-05 959436-05 959436-05 254-326 959437-05 959437-05 959437-05 Sleeve (Iron) 143-215 959436-00 959436-00 959436-00 254-326 959437-00 959437-00 959437-00 26 Screw, Imp. 143-215 809649-00 809649-00 809649-00 254-326 809885-00 809885-00 809885-00 26A Washer, Imp. 143-215 390416-00 390416-00 390416-00 254-326 390440-00 390440-00 390440-00 27 Ring Adp. (Std.) 143-256 959407-01 959408-01 959409-04 284-326 959407-01 959555-01 959556-02 Ring Adp. (Iron) 143-215 959407-00 959408-00 959409-03 254-326 959407-00 959555-00 959556-01 28 Gskt, Scr, Imp. 143-215 P02736-00 P02736-00 P02736-00 254-326 P02737-00 P02737-00 P02737-00 30A Gskt, Imp, Wshr. 143-215 390036-10 390036-101 390036-10 254-326 390038-10 390038-10 390038-10 32 Key, Imp. 143-215 051106-00 051106-00 051106-00 254-326 020746-00 020746-00 020746-00 38 Gskt. Sly. Sft. 143-215 389013-10 389013-10 389013-10 254-326 389033-00 389033-00 389033-00 38A 0 Ring, Sly. Sft. 143-215 P02065-00 P02065-00 P02065-00 254-326 P02066-00 P02066-00 P02066-00 65 Seat, Mech. Seal 143-215 P02894-00 P02894-00 P02894-00 254-326 P02895-00 P02895-00 P02895-00 71 Adapter 143-184 959354-00 959354-00 959354-00 213-215 959355-00 959355-00 959355-00 254-256 959356-00 959356-00 959356-00 284-326 N/A 959357-00 959357-00 73 Gasket, Csg. 143-215 390008-10 390008-10 390008-10 254-326 390008-10 390008-10 390008-10 80 Rotor, Mech Seal 143-215 P02886-00 P02886-00 P02886-00 254-326 P02887-00 P02887-00 P02887-00 99G Screw Cap Motor All 025748-00 025748-00 025748-00 212 Ring Seal Ret'r. 143-215 050502-00 050502-00 050502-00 254-326 050503-00 050503-00 050503-00, 773 Gasket Kit 143-215 OGASKT-12 OGASKT-12 0GASKT-12 Ref. Nos. 26, 26A, 28, 30A, 254-326 OGASKT-13 OGASKT-13 OGASKT-13 38, 38A, 73 7 Ring, Casing Std. All Iron Dresser Pump Division, Dresser Industries, Inc., Chesapeake, VA All 390496-00 390496-01 390497-00 390497-01 390012-05 390012-06

1 i )