Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Similar documents
Gas Unit Heaters PRODUCT LITERATURE. The right choice can make all the difference

GAS ABSORPTION HEAT PUMP

The ideal solution for space heating integration

Gas heaters and convectors ROBUR

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

Gas-fired unit heaters for indoor installation

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

... UDSA - UDSBD Gas fired unit heaters...

Rapid. Suspended Warm Air Heater. Caring for the environment!

1 VICTRIX ZEUS Superior kw I features

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

C Tahiti. condensing

Exclusive Green E Condensing Wall-Hung Boilers

INSTALLATION AND OPERATION MANUAL

Condensing, pre-mixed, wall-hung gas boilers with water tank

Ciao Green Condensing Wall-Hung Boilers

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

PREEVA air handling unit

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

Termo Fan. premix. Wall-hung gas furnaces. a G20 ENGINEERING brand

The iqe Boiler Range. Combination and System T Boilers.

ENERGY TOP. Condensing boiler solutions

Light oil - kerosene burner

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

The mechatronics of EVE 05

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

Mynute Green Condensing Wall-Hung Boilers

PCH/new Series. High performance, total flexibility

PCH Heating Condensing Module for Air Handling and Roof Top Units

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

Design Manual. Pre-assembled unit (LINK) Heating and Cooling/Heating modular groups. Platform PRO

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Air curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain

W - WR - WD. Technical information W- WR - WD. Gas-fired convection heaters with fan

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

GAS-FIRED AIR HEATERS MEC - MEC C SERIES Models Technical information

Power X High Power Condensing Wall-Hung Boilers

Light oil burners. One stage operation

MEC MEC C

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

Power X High Power Condensing Wall-Hung Boilers

1 - High-velocity gas burners

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

Light oil / kerosene burner

CAST IRON ATMOSPHERIC BOILERS

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

HIGH OUTPUT. Skin design RANGE

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

Copper-Fin GAS-FIRED BOILERS

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

High quality... SEALED PRE-MIXED MODULATING FAN SPECIAL METAL FIBRE BURNER FLAME DETECTION ELECTRODE IGNITION ELECTRODE FLUE OUTLET

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

Wall hung combination

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

SECTION 1: USE AND MAINTENANCE

Submittal Data GAHP Line W LB Series Ground Source Gas Fired Absorption Heat Pump Heating and Cooling

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

Copper-Fin GAS-FIRED WATER HEATERS

white blue cobalt bordeaux light oak (rovere)

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

BENSON.... Variante3 Fired Unit Heaters...

INFRARED RADIANT GAS SYSTEMS FOR THERMAL TREATMENTS

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Bluehelix Tech RRT Wall-hung condensing boiler with Ferroli Thermobalance heat cell

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Roof top SPACE RPC 315Z R407C MA00

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Forced draught gas burner

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

VPC Gas Cabinet Heater Range

REPORT. Condensing air heaters. Technology evaluation. Project report Maj 2013

CP+ Gas & Oil Cabinet Heater Range

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

BENSON GAS UNIT HEATERS

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Transcription:

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B Type B 23 on the wall Ø 80 duct, available in the following lengths: 1000, 500 and 250 mm; Ø 80 weathering collars; Ø 80 external wall terminal; Ø 80, 45 and 90 bends. ROBUR offers a complete range of accessories for B-type installations. All components are equipped with gaskets and clamps. Type B 23 on the roof Ø 80 duct, available in the following lengths: 1000, 500 and 250 mm; Ø 80, 45 and 90 bends; Ø 80 "T" piece with condensation trap; Ø 80 weathering collars; Ø 80 roof terminal assembly. TYPE B 23 This appliance must be connected to a flue which draws the exhausted gas to the outside (on the WALL or on the ROOF) of the room containing the appliance. All Robur F1 gas fired unit heaters are equipped with installation template for proper installation of the appliance. SEPARATE DUCTS KITS All accessories required to create vertical or horizontal piping are available upon request. The maximum length depends on the model of gas unit heater and the number of bends. Maximum distance between unit heater and terminal is shown in the installation manual. FLUE DUTCS AND ACCESSORIES ROOF AND WALL CONCENTRIC FLUE TERMINALS This allows for exit from the roof or wall via one hole instead of two. This kit includes external terminal and all other parts required for installation. Robur offers a complete range of F1 gas fired heaters optional to meet the different customer needs.

ROBUR ALSO MANUFACTURES: M I S S I O N Split system for cooling in summer and heating in winter. Ideal for commercial and industrial premises. ROBUR is dedicated to dynamic progression in research, development and promotion of safe, environmentally-friendly and energy-efficient products, through the commitment and caring of our employees and partners. Gas fired absorption chillers and chiller- heaters for air-conditioning, refrigeration and process applications. Ideal for commercial and industrial applications. Combi gas heating system. This split system heater provides rapid solutions to countless heating requirements. Forced draught room gas heaters perfect for small rooms. Air barriers to decreases heat loss due to frequent opening of the industrial doors. ROBUR S.p.A. Via Parigi 4/6 24040 Verdellino/Zingonia (Bg) Tel. +39-035-888.111 Fax +39-035-48.21.334 www.robur.it - exportvendite@robur.it Codice: X-DPL046 - Rev. 02-03/2004 COSCIENZA ECOLOGICA

Heating for your company COSCIENZA ECOLOGICA Gas fired unit heaters High Quality, High Performances, Low NOx

ROBUR is Prize Winner of the European Quality Award 2003: the Europe s most prestigious Award for Organisational Excellence. ROBUR Company Quality System is certified ISO 9001 since April 1995. Robur F1 heaters are CE certified in compliance with EN 1020 standard. The quality label EURO-AIR confirms Robur performances and customer focusing.

T echnical Characteristics MODEL F1 21 F1 31 F1 41 F1 51 F1 61 F1 81 Nominal heat input Nominal heat output Efficiency Air flow (1) Temperature rise Gas rate (2) Inlet gas pressure Gas connection Air inlet pipe diameter Flue diameter Electrical supply Total Electrical load Fuse rating Throw (3) Operating temperature (4) Noise level at 6 m distance Weight Natural gas L.P.G. G 30 L.P.G. G 31 Natural gas L.P.G. G 30 L.P.G. G 31 open field typical installation kw 23.08 30.77 37.15 48.35 61.32 77.14 kw 21 28 33.8 44 55.8 70.2 % 91 91 91 91 91 91 m 3 /h 2000 2700 3400 4200 5200 7800 K 31.1 30.7 29.5 31 31.8 26.7 m 3 /h 2.43 3.25 3.93 5.11 6.49 8.16 kg/h 1.80 2.42 2.93 3.81 4.84 6.09 kg/h 1.78 2.38 2.87 3.74 4.75 5.97 mbar mbar mbar mm mm 20 30 37 3/4 Female 80 80 W 260 400 230 V ~ 50 Hz single phase 450 640 900 A 6.3 m 14 16 20 22 25 29 C 0 / 35 db (A) 41 43 44 46 47 49 db (A) 53 55 56 57 60 63 kg 55 59 68 80 90 108 (1) At 20 C - 1013 mbar (2) At 15 C - 1013 mbar (3) Throws for guidance only. Throw depends on height of building, mounting height of heater, room temperature and louvre setting. (4) Internal temperature of installation room. Internal components are tested for +60 C temperature. Due to continuous product innovation and development, Robur reserves the right to change product specification without prior notice. EC Certificate EC mark guarantees product safety, in compliance with European standard EEC no. 90/396. EC certification covers 5 types of installation. ROBUR Company Quality System is certified ISO 9001 since April 1995. ISO 9001 Certificate VISION 2000 maggio 2001 2000 Vision

D imensions 10-YEAR WARRANTY ON COMBUSTION CHAMBER, BUERNER AND HEAT EXCHANGER MODEL F1 21 F1 31 F1 41 F1 51 F1 61 F1 81 A B C D E F G H J L N P Q R S T U V W X Y Z 630 630 770 880 1070 1270 640 640 670 700 640 700 800 800 800 800 800 800 490 490 490 490 490 490 370 370 510 620 810 1010 405 405 405 405 405 405 440 440 580 690 880 1080 430 430 430 430 430 430 120 120 120 120 120 120 285 285 285 285 285 285 95 95 95 95 95 95 390 390 460 515 398 468 435 435 435 435 435 435 340 340 340 340 340 340 600 600 600 600 600 600 720 720 720 720 720 720 90 90 90 90 90 90 3/4 3/4 3/4 3/4 3/4 3/4 / / / / 432 495 80 80 80 80 80 80 80 80 80 80 80 80 355 355 410 410 355 410 RIGHT SIDE VIEW FRONT VIEW F1 21-31-41-51 3 2 Y X 1 REAR VIEW F1 61-81 H C T S Z Q L R F D B max. E G A V 4 N U J P W 1 Flue - 2 Air inlet - 3 Electrical cable inlet - 4 Gas connection Due to continuous product innovation and development, Robur reserves the right to change product specification without prior notice.

I nstallation examples Heating for your company European norms classify gas appliances depending on the type of installation of combustion air inlet and exhaust duct. F1 gas unit heaters are certified for the following types of installation using the ducts, components and terminals proposed by ROBUR: TYPE C 13 Room sealed combustion circuit appliance with inlet air supply and outlet of exhausted gases, either concentric or separated ducts on the same WALL. TYPE C The combustion circuit of this appliance (air supply, combustion chamber, heat exchanger, duct for exhausted gas) is sealed with respect to the room where the appliance is installed. Ducts for combustion air inlet and exhausted gas are both connected outside and the terminals might also be connected on different walls (for example, combustion air inlet on the wall and exhaust duct on the roof). Robur offers a complete range of accessories for c-type installations. All components are equipped with gaskets and clamps: TYPE C13 ACCESSORIES Horizontal concentric flue terminal TYPE C 33 Room sealed combustion circuit appliance with inlet air supply and outlet of exhausted gas, either concentric or separated ducts on the ROOF. TYPE C 53 Room sealed combustion circuit appliance with inlet air supply and outlet of exhausted gas by using separated ducts and terminals on different WALLS. Separated ducts kit with measuring point, length 1000 m, inclusive of terminal assembly. The following accessories are also available: Ø 80 duct, available in the following lengths: 1000, 500 and 250 mm; Ø 80 weathering collars; Ø 80 external wall terminal; Ø 80, 45 and 90 bends; Ø 125 wall terminal assembly. TYPE C33/C53 ACCESSORIES Vertical concentric flue terminal Ø 80 duct, available in the following lengths: 1000, 500 and 250 mm; Ø 80 external roof terminal; Ø 80, 45 and 90 bends; Ø 80 T piece with condensation trap; Ø 80 weathering collars; Ø 80 roof terminal assembly.

Heating for your company I DEAL The all new ROBUR F1 gas fired unit heaters: Heat any type of commercial environment and ambient requirements Add Simplify high quality and prestige to your installations the installation and make your work easier Save time and thus reduces cost For these reasons the Robur F1 unit heaters are ideal for you. There are more than 180,000 ROBUR gas fired unit heaters installed throughout Europe.

POWERFUL Heating for your company The new Robur F1 gas fired unit heaters are available in 6 models with outputs from 21 to 70.2 kw and two colours: Robur-Orange and Pearl-Grey. The Robur F1 series adds exclusive advantages to the basic Robur unit heaters, such as: Optimised combustion F1 unit heaters ensure ultra-clean combustion (carbon oxides) and combustion residues are kept to a minimum. Model F1 21 Product range: Heat output kw 21 F1 31 28 F1 41 33.8 F1 51 44 F1 61 55.8 F1 81 70.2 In advance on the Draft of European Norm Project for NOx emissions, F1 unit heaters already have lower values: up to 30 ppm, for both Natural gas and LPG. Higher Thermal Efficiency: over 91% guaranteed under any installation conditions. Low thermal head High air flow Higher air throw High volume of air re-circulated Higher heat output

External terminal: only 4.3 cm projection The new external terminal for 80 mm diameter (separate) inlet and outlet ducts is a Robur personalized accessory. In addition to its modern design, the extremely limited projection (4.3 cm from the wall) is another of its exclusive characteristics. This aluminium terminal maintains a low operating temperature which makes it safer, it can also be painted in the same colour as the wall, following the customer s needs. Remote control box and other accessories Robur F1 unit heaters have many options to allow installation to meet the customer s operating needs. Standard remote control All Robur F1 unit heaters are supplied with a remote control box, lock-out light, reset and summer/winter switches. Room thermostat This option is a mechanical type thermostat with on-off switch. Analog programmable timer This has an electronic thermostat with two independent control temperatures, allowing weekly programming of heater operation. The timer has a quartz movement and mechanical summer/winter switch. Digital programmable timer This accessory incorporates in a single device all programming and control functions of the gas unit heater, both daily and weekly. Revolving wall support bracket This allows for an easy and correct installation of the gas unit heater. Vertical louvres These allow for left and/or right adjustment of the airflow from the front of the unit according to the site conditions and the customer requirements. Tubular wall brackets Very easy to install, it fits to all models and it is supplied with tie-rods, bolts and washers to anchor to the wall.

STRONG Heating for your company The heating installation which uses Robur F1 unit heaters has a global efficiency higher than most other systems. Tests performed at Robur Research and Development Center, as well as at several systems installed at sites all over Europe, have demonstrated that, assuming the heat outputs installed are the same, Robur unit heaters reduce consumption and offer a higher environmental comfort than other heating systems. Robur heaters allow users to reduce consumption and heat stratification problems. Its secret is the heat exchanger the real heart of Robur unit heaters which split the air flow into different layers having different temperatures: lower temperature in the higher levels and vice versa higher temperature in the lower levels. This results in the lower, hotter air being kept down by the higher, cooler air. Thus the different temperatures within the air-throw ensure a complete air mixing, thus reducing the temperature gradient between floor and ceiling. Height from floor level This Ground Effect is another exclusive advantage of Robur gas fired unit heaters. The performance data for Robur installations all over Europe are available upon request. The thermography on the left shows the concept of the GROUND EFFECT. Room height 5 m 6 m 7 m 8 m 9 m Energy saving 12 % 14 % 16 % 19 % 22 % This table shows the reduction of thermal energy need (compared to traditional project data) following the higher global efficiency of the heating Robur system.

Inside the product: the heart The heat exchanger is designed with double vertical and horizontal finning, increasing internal and external heat exchange surface. Made out of a special aluminum die-cast alloy (its high thermal conductivity is 10 times higher than steel) it allows a more homogeneous temperature on exchange surfaces with optimal distribution. The large heat exchange surface and the absence of high temperature areas avoid the carbonization of atmospheric dust, ensuring a perfect environmental comfort. Smart safety devices For safety protection: High limit temperature switch, 100 C with manual reset to avoid overheating of the heat exchangers. Differential air pressure switch monitors flow and shuts down the heater in the event of flue or combustion air blockage or flue fan failure. Pre-mixing fan with electronic control (F1 51 and F1 81 models). Gas solenoid valve which automatically shuts down the gas supply if any of the safety or control devices are activated. Flame control and ignition control box monitoring pre-mixed burner ignition and flame detection operations. Specification HIGH PERFORMANCE, forced draught F1 unit heaters are manufactured in compliance with the law in force concerning performance, energy saving and safety. They also comply with CEE Directive no. 89/336, concerning radio interferences. Stainless steel pre-mixed burner. Direct electronic ignition on the burner via twin electrodes for maximum safety and quick ignition at low temperatures. Protection against electromagnetic interferences. Room-sealed cylindrical combustion chamber, made of stainless steel, completely separated from the electric board to fully protect electric and electronic components. Robur patented heat exchanger is designed with double vertical and horizontal finning, increasing internal and external heat exchange surface. Made from a special aluminum die-cast alloy, with high thermal conductivity. High-efficiency axial fan. Radio interferences protection system. Steel external panels painted with epoxy powders available in two different colours.

Heating for your company E ASY The unique design features of the Robur F1 unit heaters make for an easy to fit and safely in any type of installation. EASIER INSTALLATION 80 mm duct diameter The air and exhaust ducts of F1 unit heaters have the same diameter: 80 mm. All unit heaters are equipped with air and exhaust gaskets already installed on the appliance, thus requiring no adapters.

Our secret: enhanced quality Robur F1 unit heaters are equipped with a multigas burner: made of stainless steel with optimum air/gas ratio. This allows a supply to the burner of a gas/air mixture already prepared for combustion, without any need for secondary air supply. This innovative burner, state-of-the-art in Europe, offers the following advantages: Simplified ordinary servicing Guaranteed and long life efficiency Resistance to thermal stresses Insensitivity to atmospheric humidity and to condensate occasionally produced in the combustion chamber The countersunk flame orifices are able to reduce the temperature of the burner's surface thus extending its lifetime and assuring constant performance throughout. A further guarantee of extended life is the reduction of thermal expansion and the related mechanical stress. The large section of the flame orifice strongly reduces the deposit of the atmospheric dust, avoiding the burner becoming dirty: thus you can guarantee constant performance over time. Gas conversion simplified; change just one injector in an ergonomic position. This new Robur burner, with complete gas/air premixing, is the basis for the advantages offered by F1 unit heaters. Low NOx gas unit heaters have been developed in advance, but in compliance with the Draft of European Norm. Nitric oxide emission NO x Average values on the market Maximum values being legislated in european countries Limit value in ZURICH metropolitan area Certified values of F1 series 150 130 120 55 40 30 ppm For a long time and with close attention, manufacturers in the heating market have been following the environmental issues. The Draft of European Norm for the NOx emissions establishes the classification of heaters regarding those emissions. Specifically, the Draft sets the highest level of NOx for the Heaters at 147 ppm. Indifferent to the combustion gas or burner used, these limits are to be applied to all heaters. This Draft is among those initiatives aimed at developing the quality standards and reducing the environmental impact.