INSTALLATION AND OPERATING INSTRUCTIONS

Similar documents
INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

JÄSPI Solid Fuel Boiler

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens

Multi Energy Boilers. Duo 1 & 2 Triplex 1000 & 3000 Biotriplex. Oil Gas LPG Wood Briquettes Electricity Solar thermal Solar photovoltaics

Installation, operation and care Firewood boiler Vedolux 40 UB

INSTALLATION, OPERATION AND MAINTENANCE. ARITERM SWEDEN AB Installation, Operation & Maintenance /28

PELLET BURNER PV 350

Description of functions

Wood logs boiler with a gasication eect IGNIS KW. INSTRUCTIONS MANUAL for usage and maintenance

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4

WOOD CHIP HEATING HPK-RA

WOOD CHIP HEATING HPK-RA

Incident Summary (II )

ARITERM-VTT-S INSTALLATION AND OPERATING INSTRUCTIONS

ARITERM-VTT-S INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm Biomatic+ 20

OPERATING INSTRUCTIONS with safety features

INSTALLATION, OPERATION AND MAINTENANCE. Bio burners kw

- 12, , TECHNICAL INSTRUCTIONS

Heating with Wood. Part 2

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

ENTROPIE boiler TT300

Installation, operation and care. Pellmax UB. Burner not included Replaces:

TECHNICAL AND OPERATIONAL DOCUMENTATION

Heating with log wood

AIEA Presentation. Wood pellets heating systems.

WOOD CHIP/PELLETS HEATING SYSTEMS

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE

ARITERM OY. Arimatic 500. User manual

HDG K SERIES. Wood pellet boiler. The perfect alternative to fossil fuels. Receive up to

Aquaflam Wood boiler stoves and fireplace inserts

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Fully water jacketed secondary chamber with stainless steel afterburner

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

ENTROPIE boiler TT100-01

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.

Biomass. Biomass solid fuel boiler range

VETO CLEANER 500 FLUE GAS CLEANER

User & Installation instruction

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

MOS GB INSTALLATION AND MAINTENANCE INSTRUCTIONS VEDEX 1000 VEDEX 1000 M10527 LEK

Light oil - kerosene burner

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Boiler. Fire tube Boiler:

Boiler Technical Specifications (2013)

Technical Datasheet. Solo Innova Models 30 and 50. Benefits at a Glance: Solo Innova

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

STATEMENT OF SOLID FUEL APPLIANCE PERFORMANCE

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

HYBRID SERIES FURNACES. napoleonheatingandcooling.com

WOOD BOILER SWEDISH MADE V202KUB

HERZ ECO-Line Heating with logs or wood pellets

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE

OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address

Instruction Manual: Le Jurassien Ref 3701

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

INSTALLATION, OPERATION AND MAINTENANCE. Multijet hydraulic

HEATING TECHNIQUE PRODUCT CATALOGUE

AIM OF THE EXPERIMENT:- Study of boilers (fire tube, water tube) APPARATUS REQUIRED: - SL.NO NAME OF THE APPARATUS SPECIFICATION QUANTITY 01 Fire tube

Combined boiler. for solid fuel and pellets

INSTRUCTION MANUAL. for installation and operation of solid fuel cookers. Victoria and Victoria Lux

English. Heating with logs & wood pellets 20-40

Gasification boiler PYROLYT INSTRUCTION MANUAL. ver. 1.1

tççç= ÜÉ~íáåÖ çéíáçåë

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model EGIS - AS. R EN - Edition 03-01/03/2008

PV1000agri pellet burner

Solid fuel hot water boiler TKH KW INSTRUCTIONS MANUAL for usage and maintenance

Pellet burner PV 180a. User manual

Manual and installation instructions. Function. Operating phase

TABLE OF CONTENTS. Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2


Installation & Manual. Model T-25

TABLE OF CONTENTS ARITERM OY bio burners burn back protection arimax bio kw boilers

Efficiency Maximiser for Solid Fuel Central Heating

stoves...make yours a Yola.

SB615/310 Stainless Steel Condensing Boiler

Wood-firing at its simplest

Cm Pelet-set - touch TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT

Technical Datasheet. FHG-S Models 28, and 45. Benefits at a Glance: State Route 22 Salem, NY 12865

Solid biofuel solutions

Wood pellets economical and environmentally friendly. Wood pellet heating

SAUNA HEATER INSTALLATION AND OPERATING MANUAL

Easyfire Standalone biomass pellet boiler

anti-condensation valve

100% IRISH...make yours a Brightfire.

BIOMASS BOILER DUAL THERM

HERZ firematic

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

Installers Awareness Booklet. Please read before installation as this booklet contains important Information

Pioneers of heating with biomasses

Standards of Training in Safe Gas Work Domestic Natural Gas Training Specification

Electronic pellet burner controller - NPBC-V3M. Electronic Pellet Burner Controller NPBC-V3M

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

PUSHING THE LIMITS OF WHAT IS POSSIBLE

Transcription:

INSTALLATION AND OPERATING INSTRUCTIONS

CONTENTS 2 6 7 8 9 10-12 16 17 18 18 19 2

GENERAL TRANSPORTATION, STORAGE AND OPENING THE PACKAGE Receiving the goods - Storage Opening the package 3

INSTALLATION - Space requirements Flue connection and combustion air opening 2 Plumbing connections - Safety vent installation - - 4

INSTALLATION - - - Part Name 1 Ariterm 35+ boiler 2 3-way valve, underfloor heating 3 3-way valve, radiator heating 4 Heat supply pump, underfloor heating 5 Heat supply pump, radiator heating 6 Underfloor heating system manifold 7 Radiator heating system 8 Expansion vessel 9 Service shut-off valve 10 Safety vent 11 Refill valve 12 Input mixing valve 13 Process water circulation pump 14 Thermal safety device 15 Accumulator switch Laddomat 21 (LVI-5012921) 16 Warm water accumulator 5

INSTALLING THE TEMPERATURE LIMIT VALVE - Installation TECHNICAL SPECIFICATIONS Max. input water pressure Opening temperature 10 bar 97 C Valve available from Ariterm Oy Product no. 5012921 6

DIMENSIONS AND CONNECTIONS Without flue gas fan With flue gas fan Part Name Unit 1 Turning plate adjustor 2 Damper adjuster 3 Charging pump thermostat 4 Water pressure gauge 5 Water thermometer 6 Combustion gas thermometer 7 Firebox hatch 8 Primary air damper 9 Secondary air damper 10 Refill hatch 11 Convection cleaning hatch 12 Convection ash removal hatch Part Name Unit 13 Fixed hatch for afterburning chamber 14 Boiler temperature sensor unit DN 20 15 Water accumulator outlet DN 50 16 Water accumulator return DN 50 17 Expansion unit DN 25 outer thread 18 Blow-off unit DN 15 19 Cooling spiral units Cu 15 20 Flue connection 168 21 Flue gas fan (A35-121A) 22 Fan EBM R2E 180-CG82-05 7

TECHNICAL SPECIFICATIONS / BOILER CROSS-SEC TION TECHNICAL SPECIFICATIONS Performance values: Power 20-40 kw Measurement data: Design and adjustment values: Width Depth Height Weight empty Water capacity Storage chamber volume Burning time Size of refill opening Boiler operating pressure Permitted operating temperature Suitable size of accumulator Max. length of logs 800 mm 1109 mm 1300 mm 690 kg 150 L 120 L 37 kg / 3 h 550x350 mm 0,5-1,5 bar Max 120 C 1800 3000 L 0,5 m direct damper storage chamber afterburning chamber convection section grate primary air secondary air 8

OPERATING PRINCIPLE Wood gasification - - Afterburning of gases - - - Heat recovery - 9

INSTALLATION OF THE GRATE AND CERAMIC COM- PONENTS - - 1. Lower brick 2. Lower part of side brick (2 pcs) 2. Lower part of side brick (2 pcs) 3. Lower part of front brick 10

INSTALLATION OF THE GRATE AND CERAMIC COM- PONENTS 3. Lower part of front brick 4. Lower part of rear brick 5. Upper part of rear brick 5. Upper part of rear brick 6. Upper part of front brick. The upper parts support each other with a suitably sized piece of wood in between, for example. 11 6. Upper part of front brick

INSTALLATION OF THE GRATE AND CERAMIC COM- PONENTS 6. Upper part of front brick. 7. Upper parts of side brick (2 pcs) (pay attention to left-or right-handedness). Remove the temporary support then installation is complete. Installation of base bricks 1. 2. 3. 12

OPERATION Introduction into use First heating cycle - Basic adjustments - 13

HEATING Lighting the boiler - - - - - - grate afterburning chamber Turning plate handle Heating Driftläge position Lightning- Tänd- ochand lling position påfyllningsläge Damper handle opening for burning chamber Pic 1 Open Öppen Closed Stängt Pic 2 14

HEATING Primary Air hatch Secondary Air hatch Refilling N.B. Fuel should only be refilled when the energy created can be stored in the accumulator tank or otherwise consumed. Boiling of the accumulator tank and boiler must be avoided. 15

SERVICE AND MAINTENANCE Cleaning N.B. The surface of the ash must never rise up to touch the grate. This prevents cooling of the grate and will rapidly result in damage. For this reason too, the holes in the grate must be open. Ensuring the tightness of the hatches - 16

THE USE OF ALTERNATIVE FUELS Use of an oil burner - Use of electricity - Pellet use - 17

WARRANTY AND REMOVAL FROM USE Warranty - - Removal from use MOST COMMON SPARE PARTS Part number Name Additional information Quantity 13285 Grate 1 13611 Front brick lower 545x115x109 1 13612 Rear brick lower 545x126x88 1 13613 Lower brick 446x255x50 1 13614 Side bricks lower part 50x150x275 2 13615 Side bricks upper part left 50x131x322 1 13616 Side bricks upper part right 50x131x322 1 13617 Front brick upper 545x104x215 1 13618 Rear brick upper 545x210x137 1 13375 Gas spring 2 5880 Thermometer 1 5883 Combustion gas thermometer 0-500 C 1 5882 Pressure gauge 1566 SWOY 1 5351 Thermostat TR2 0-90 C 1 10040 Brush 40x80x110 M12 1 3492 Brush arm 1250 mm 1 5805 Locking pin sleeve inc. screws 1 18

DECLARATION OF COMFORMITY 19

20.03.2009 - All Rights to modifications and corrections reserved.