EMERGENCY SHOWERS AND EYEWASHES

Similar documents
Eyewash and Eye/Face Wash units that are either wall mounted or pedestal mounted. 7260B B 7270B

Contents. Eye/Face Washes... 3 Eyewashes... 3 Swing-Away Eyewashes... 4 Eyewash/Drench Hose Units... 4 Emergency Showers... 4 Safety Stations...

Emergency Showers & Eye Wash Stations

8200 Combination Units

PRODUCT CATALOGUE. We ensure safety in risky environments.

7000BT Eye/Face Washes

S19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:

S19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:

SHOWER, EYEWASH & FACEWASH PRODUCTS

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

EMERGENCY EQUIPMENT AXION MSR MEDICALLY SUPERIOR RESPONSE PRODUCTS EYE/FACE WASH :: SHOWERS COMBINATION UNITS

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

C. EWFs shall deliver the quality and quantity of water that is satisfactory for emergency washing purposes.

EMERGENCY EYEWASH AND SHOWER TECHNOLOGY

EMERGENCY EQUIPMENT AXION MSR TM EYE WASH :: EYE/FACE WASH SHOWERS :: COMBINATION UNITS

TEMPERED WATER. Solutions for Safety Showers

SAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

TOP 15 :: EMERGENCY EQUIPMENT

Table of Contents ICON KEY. Quick ship icon indicates product is available for shipment within 48 hours for quantities of 4 pieces or less.

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

A. This Section includes the following emergency plumbing fixtures:

Product overview Suction Guns, suction machines, Vac-Blast Cleaners

EMERGENCY EQUIPMENT AXION MSR MEDICALLY SUPERIOR RESPONSE EYE/FACE WASH :: SHOWERS COMBINATION UNITS PRODUCTS

ООО "ТИ-СИСТЕМС" Overhead Water Tank Solutions (ISTEC Type ESW-OWT) Cable Heated Insulated Solutions (ISTEC Type ES/ESW-ICH)

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

S19361HF - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

EMERGENCY EYEWASH AND SHOWER

SHOWER, EYEWASH & FACEWASH PRODUCTS

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

PRODUCT CATALOGUE. We ensure safety in risky environments.

USERS MANUAL FOR GAS BOILERS

This Product MasterSpec Section is licensed by AVITRU, LLC to Haws Corporation ("Licensee").

YanCheng STG Safety Equipment Co.,Ltd 1

EMERGENCY DRENCH SHOWER

OPERATING AND INSTALLATION MANUAL

Flow Factor ~

OPERATING AND INSTALLATION MANUAL

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

Automatic Water System Pump SERIES

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

EMERGENCY EQUIPMENT AXION MSR MEDICALLY SUPERIOR RESPONSE EYE/FACE WASH :: SHOWERS COMBINATION UNITS PRODUCTS

Sioux E-Series. All-Electric Compact Industrial Steam Cleaners & Pressure Washers. Sioux E-Series All-Electric Steam Cleaners and Pressure Washers

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Automatic Temperature Controller (ATC)

ЭКСПЛУАТАЦИЯ И МОНТАЖ ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ

VADA - Rain2Main Automatic Rainwater Controller

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

- Hand Held Eye Showers & Accessories. - Heated Emergency Showers & Eye Washes EMERGENCY SHOWER SYSTEMS

Hand pump JP-02. Hand pump JP-02 for acids, alkalies and water-based chemicals. depending on lever position. The telescopic suction tube is adjustable

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

Tornado Operations & Maintenance Manual

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

AQUAFIT - the innovative single-lever mixer for safety and hygiene

ZYPHO IZI INSTALLATION MANUAL. Please read the entire manual before starting the installation process. (2) (1)

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

TEMPOMIX COMFORT WATER SAVINGS VANDAL-RESISTANT SAFETY. Time flow basin mixer

We have our range of Bath fittings which completes the lifestyle offering to millions of customers across India. The Elegance quality and style in

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

AHWG Remote Mount Hot Water Generator Module for TTP Series Outdoor Split Unit

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

FSW300 Series Flow Switch

also CE marked in accordance with relevant EC (European Community) directives. The development of this advanced range of emergency products has

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA

OPTISENS TUR 2000 Technical Datasheet

Model /8300CRP-8309CRP Shower & Eye/Face Wash

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Friwa Compact. Operating instructions EN

CLE SERIES Fluid heating for emergency eyewash stations

MODEL 7000 SUCTION UNIT

INSTRUCTION MANUAL HETO CBN 8 / 18 / C Cooling Baths ID: IM.doc Revision 1

when seconds count you can depend on us

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50-6/16LP50-6, 16NG60-6/16LP60-6, 20NG50-6/20LP50-6, 20NG60-6/20LP60-6, 26NG50-6/26LP50-6, 26NG60-6/26LP60-6

NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

DIGITAL MODULATING BOILERS

INSTANT-FLOW C-MICRO WATER HEATER

TERMINATOR 120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

HHP-300 EXTRACTOR 120V

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

Installation & Operation Instructions Nr _EN_Manual

Rules for Safe Operation

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Version 7 1/ LXP

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

AHWG Remote Mount Hot Water Generator Module

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

Model 7500EB Portable Eyewash with Heater

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Model Combination Shower Eye/Face Wash

SA gal, 6 min. Flush (Eng. inst.) 19 SAM gal, 6 min. Flush (Fr. inst.) 19

INSTANT-FLOW C-MICRO WATER HEATER

Tornado Operations & Maintenance Manual

Transcription:

EMERGENCY S AND ES

INDEX TECHNICAL INFORMATION PRESENTATION CERTIFICATES DESIGN AND MANUFACTURING TECHNICAL CHARACTERISTICS 1 2-3 4-5 6-7 SELF-DRAINING S AND ES PLATFORMS FLOOR MOUNTING DECONTAMINATION BOOTH UNDERGROUND FLOOR MOUNTING INTERIOR WALL MOUNTING UNDERGROUND PLATFORM 28-29 - 31 30 31 32-35 33 34 EMERGENCY S AND ES FLOOR MOUNTING WALL MOUNTING RECESSED MOUNTING 8-11 12 13 TANK S OVER HEAD TANK UNDERGROUND TANK 36 37 EMERGENCY ES WALL MOUNTING FLOOR MOUNTING TABLE MOUNTING DRENCH HOSE ES RECESSED MOUNTING EMERGENCY S FLOOR MOUNTING CEILING MOUNTING WALL MOUNTING OVER DOOR MOUNTING RECESSED MOUNTING 14 15 16-17 18 19 20 21 21 22 23 ACCESSORIES TEMPERED WATER TEMPERATURE PROTECTION PRESSURE PROTECTION BOOTH STRUCTURE PLATFORM TEST WALL SUPPORT ALARM KIT INSTALLATION AND MAINTENANCE INSTRUCTIONS INSTALLATION OPERATION MAINTENANCE SIGNS 38 39 39 40 40 41 41 41 42 43 43 43 S AND ES SPARE PARTS S AND ES S ES PLATFORMS 24 25 26 27 SPARE PARTS Reproduction in whole or part of this catalog by any media is prohibited without express permission of CARLOS ARBOLES, S.A. 44

SAFETY EQUIPMENT GENERAL CATALOGUE 2018 Since 1929, Arboles manufactures tap fittings of diverse types and applications; we now specialise in two product lines: EMERGENCY S AND ES TAP FITTINGS FOR LABORATORIES CARLOS ARBOLES, S.A. is certified to ISO 9001, and all the products manufactured in the company are made under strict quality standards. Since 1976 we have been supplying the international market with a full range of Emergency Equipment. In this catalogue we show our current models. The Emergency Showers and Eyewashes instantly offer water as a FIRST AID treatment to people who have been exposed to: fire, acids, reagents, radioactive materials, and other contaminants that might cause serious or irreparable injury. This is the most inexpensive and effective method to date for decontamination. 1

CARLOS ARBOLES, S.A. designs and manufactures Emergency Equipment complying with the current International standards that ensures the user s safety. The requirements of these standards are, among others: the flow to be supplied by the Emergency Equipment, the distribution of the water pattern on the body, the dimensions of the facility and the operating elements, signs and accessibility aspects. CERTIFICATES EUROPEAN STANDARDS The European Standard EN 15154 applies in Europe. According to this standard, the Emergency Equipment is divided into: Emergency Showers used in Laboratories EN 15154-1:2006. Emergency Eyewashes EN 15154-2:2006. The following are the statements of compliance of both standards certified by the Spanish entity APPLUS. In Europe, the only standard for Emergency Showers used in industrial facilities is the German Standard DIN 12899-3:2007. The following is the compliance statement certified by the entity APPLUS. AMERICAN STANDARD At the international level, the American standard ANSI/ISEA Z358.1-2014 is recognized worldwide for Emergency Showers and Eyewashes. The following is the certificate of compliance issued by the CSA Institute. 2 3

CARLOS ARBOLES, S.A. has its own design and manufacturing team for Emergency Equipment that develops, innovates and improves its products. DESIGN AND MANUFACTURING DESIGN Our technical department continually develop and improve our products, along with specially required projects. The latest CAD/CAM technology is employed for production and PROTOTYPING of components. These prototypes are validated in our test LABORATORY. Strict mechanical and hydraulic tests are performed in the laboratory, which guarantee the functionality of the designs in emergency situations. MECHANICAL TESTING CAD/CAM TECHNICAL DEPARTMENT MANUFACTURING The manufacturing process uses high-precision numerical control lathes and machining centers specifically designed for the production of tap fittings. High-performance ovens heat the parts between 300º C and 450º C to later dip them in polyamide 11 powder tanks, where the powder is melted and adheres to the part. After the anti-corrosive coating process, the assembly line finishes the manufacturing process with 100% watertight control of the parts. Throughout the process, the Quality department checks the manufacturing parameters. NUMERIC CONTROL MACHINING CNC MACHINING TEST LABORATORY ANTI-CORROSIVE PLASTIC COATING HYDRAULIC TESTING PRODUCTS ARE 100% LEAK TESTED 4 5

EMERGENCY S AND ES CARLOS ARBOLES, S.A. supplies high quality Showers and Eyewashes that are extremely reliable. The following are the main technical characteristics that distinguish our products. TECHNICAL CHARACTERISTICS 1 HIGH QUALITY MATERIALS Materials in contact with water are galvanized steel pipes, brass fittings and ABS reinforced plastic. We also have the ability to manufacture equipment in stainless steel. 2 ROBUST CONSTRUCTION All our products are constructed from high quality materials, where fastening is surface mounting the components are always metallic. This results into a robust equipment for the most adverse conditions. 3 HEAD The water distribution pattern is in accordance to all relevant standards to give a wide and smooth flow pattern. The large Shower head diameter of mm and the design of the flow holes prevent restricted flow caused by lime scale or contamination. 4 FULL RANGE We have different models based on their installation, WALL, FLOOR, or TABLE mounted. The equipment is supplied disassembled, its assembly is easy and unmistakable. We have different types of mechanisms: Shower with a pull handle or lever. Automatic opening and closing when entering and leaving the platform. Eyewash with a push lever, pedal, or platform operation. 700 mm 6 3 20" 50 % - 400 mm 50 % - 800 mm ANSI STANDARD EN STANDARD 7 10 60" 9 2 1 8 7 ANTI SEIZE VALVE The Showers and Eyewashes include valves that are specifically designed to be used in emergency situations, since they do not become obstructed nor do they stick up after long periods of inactivity. Optimal results after more than 100,000 cycles. 8 TEMPERATURE PROTECTION In order to prevent freezing or excess temperature in the pipes, we offer different solutions: Automatic drain valves to avoid pipe freezing. gpm l/min Temperature protection valves, that create a bleed line when the temperatures of the supply piping are extreme. Thermostatic valve for the supply of tempered water. 31,7 29 26,4 21,1 15,9 120 110 100 80 60 9 FLOW RATE REGULATION Our valves regulate the water flow, regardless of the inlet pressure. The Showers are regulated at 110 l/min, and the Eyewashes at 22 l/min. Recommended pressure: 2 bar. Maximum pressure: 4 bar or 8 bar depending on equipment. 10,6 5,8 5,3 40 22 20 0 0 1 1,5 2 3 4 5 6 7 8 bar 15 20 30 45 60 75 90 100 115 psi RECOMMENDED MINIMUM S ES MAXIMUM Please notify us if your equipment will operate at pressures lower than 1.5 bar. 5 ASSEMBLY One or two spray heads offer a low pressure aerated water, which flushes the face and the eyes without damaging the delicate eye tissues. The large-diameter jet reaches a 15 cm height, according to the standard. The plastic materials and rounded forms will not cause facial damage in the case of accidental contact. They include an anti-dust cover which operates automatically when the Eyewash unit is activated. 150 mm 1,25" 3,25" 5 10 HIGH-VISIBILITY SIGNALLING The Emergency Equipment includes: A photoluminescence signaling plate with a green background and white text. Dimensions: 210 x 297 mm Maintenance table and installation instructions. Optionally, an ALARM that may provide a visual and sonorous signal when the Equipment is operated. 6 ANTI-CORROSIVE AND ENVIRONMENTAL COATING Anti-corrosive polyamide 11 plastic coating, in HIGH-VISIBILITY YELLOW color. This plastic coating has a thickness of to 300 microns. It has good resistance to acids, bases, sea water, oils... The coating is not derived from petroleum, but is a raw material originating from vegetable oil, and therefore, it preserves the environment. We have a Chemical Resistance Table, which can be consulted on our website:. 4 INTERNATIONAL STANDARDS Our products meet or exceed the requirements: ANSI Z358.1 EN 15154 1 and 2 DIN 12899.3 APPLUS and CSA Institute of Certifications. 6 7

USE The following models combine the Shower and the Eyewash in one Safety Equipment for outdoor and indoor facilities, minimizing the required space, and using a single water inlet for both equipments. MATERIALS Galvanized steel piping. Brass fittings. COATING Anti-corrosive polyamide 11 in high-visibility yellow. DOUBLE WATER INLET BSP. Maximum 8 bar. OPERATION Pull handle. VALVE Full bore 1", regulated at 110 l/min, instant opening and manual closing. OPERATION Push handle. HEADS Two high-flow aerated water spray heads at low pressure with automatic opening anti-dust cover. VALVE Full bore 1/2", regulated at 22 l/min, instant opening and manual closing. EMERGENCY S AND ES FLOOR MOUNTING HEAD/BOWL ABS 415 2100 ø HEAD/BOWL 4220 4220 SS 4230 4230 SS ø 760 605 190 PULL ROD, PUSH HANDLE PULL ROD, PUSH HANDLE INCLUDES SPRAY UNIT MOD. 3000 1635 FLOOR MOUNTING 1135 HEAD/BOWL ABS WASTE 150 HEAD/BOWL 4 4 SS 4255 4255 SS PULL ROD, PUSH HANDLE AND FOOT TREADLE PULL ROD, PUSH HANDLE AND FOOT TREADLE INCLUDES SPRAY UNIT MOD. 3000 MOD. 4220 MOD. 4230 SS MOD. 4 8 9

USE The following models combine the Shower and the Eyewas in one Safety Equipment for outdoor and indoor facilities, minimizing the required space and using a single water inlet for both equipments. MATERIALS Galvanized steel piping. Brass fittings. COATING Anti-corrosive polyamide 11 in high-visibility yellow. DOUBLE WATER INLET BSP. Maximum 8 bar. OPERATION Pull handle. VALVE Full bore 1", regulated at 110 l/min, instant opening and manual closing. OPERATION Push handle or foot treadle. HEADS Two high-flow aerated water spray heads at low pressure with automatic opening anti-dust cover. VALVE Full bore 1/2", regulated at 22 l/min, instant opening and manual closing. EMERGENCY S AND ES FLOOR MOUNTING HEAD ABS 415 2100 HEAD 4260 4260 SS 605 ø 310 PULL ROD, PUSH HANDLE WITHOUT BOWL LOW CEILING Low ceiling Shower and Eyewash combination has been designed for areas with a heigth limitation. 2315 2150 1500 1135 ø ø 510 735 165 ø WASTE 150 1635 REDUCED MOBILITY Reduced mobility Shower and Eyewash combination has been designed for disabled people or wheelchair access. 2265 2100 ø 330 1070 150 MOD. 4221 MOD. 4225 MODEL 4221 PULL ROD, PUSH HANDLE, HEAD/BOWL ABS, LOW CEILING MODEL 4221 SS PULL ROD, PUSH HANDLE, HEAD/BOWL, LOW CEILING 1185 960 685 WASTE 150 1315 MODEL 4225 PULL ROD, PUSH HANDLE, HEAD/BOWL ABS, REDUCED MOBILITY MODEL 4225 SS PULL ROD, PUSH HANDLE, HEAD/BOWL, REDUCED MOBILITY MOD. 4260 10 11

WALL MOUNTING USE The following models combine the Shower and the Eyewash in one Safety Equipment for outdoor and indoor facilities, minimizing the required space, and using a single water inlet for both equipments, RECESSED MOUNTING USE Indoor Safety Equipment recessed in the wall. Emergency Shower starts operating when you lower the lever and Eyewash starts operating when you opening stainless steel door. MATERIALS Galvanized steel piping. Brass fittings. COATING Anti-corrosive polyamide 11 in high-visibility yellow. WATER INLET G 1" BSP. Maximum 8 bar. WATER INLET PRESSURE MOD. 4275 3 bar. OPERATION Pull handle or cabinet lever. VALVE Full bore 1", regulated at 110 l/min, instant opening and manual closing. OPERATION Push handle or cabinet handle. HEADS Two high-flow aerated water spray heads at low pressure with automatic opening anti-dust cover. VALVE Full bore 1/2", regulated at 22 l/min, instant opening and manual closing. VALVE MOD. 4275 Flow 20 l/min at 3 bar, instant opening and manual closing. INSTALLATION Height assembly see pag. 42. EMERGENCY S AND ES MOD. 4285 WALL MOUNTING MOD. 4295 ø 660 760 G 1" 1450 RECESSED MOUNTING HEAD ABS MOD. 4275 ACCORDING TO INSTALLATION 4275 HEAD 4275 SS ø RECESSED AND, PULL ROD, OPENING BOX 150 OPTIONAL PIPE HEAD ABS HEAD 200 4280 4280 SS PULL ROD, PUSH HANDLE WITHOUT BOWL 4285 4290 4285 SS 4290 SS PULL ROD, PUSH HANDLE PULL ROD, DRENCH HOSE 358 399 4295 4295 SS PULL ROD, DRENCH HOSE DOUBLE G 1" MOD. 4290 MOD. 4275 12 13

USE In outdoor or indoor facilities the Eyewashes are activated by pushing the lever. MATERIALS Galvanized steel piping. Brass fittings. COATING Anti-corrosive polyamide 11 in high-visibility yellow. WATER INLET G 1/2" BSP. Maximum 8 bar. OPERATION Push handle, foot treadle or swivel opening. HEADS Two high-flow aerated water spray heads at low pressure with automatic opening anti-dust cover. VALVE Full bore 1/2", regulated at 22 l/min, instant opening and manual closing. VALVE MOD. 3820 Flow 20 l/min at 3 bar, instant opening and manual closing. INSTALLATION Height assembly see pag. 42. EMERGENCY ES WALL MOUNTING BOWL ABS BOWL 2210 2210 SS 2230 2230 SS 3510 3820 190 230 WALL WITH DRENCH HOSE MOD. 3000 WITHOUT BOWL SWING OUT WITHOUT BOWL ø FLOOR MOUNTING BOWL ABS BOWL 2220 2220 SS 2240 2240 SS 2710 2710 SS PEDESTAL WITH DRENCH HOSE MOD. 3000 DOUBLE CONTROL HANDLE/TREADLE MOD. 2220 190 ø G 1/2" 1100 890 240 WASTE G 1/2" MOD. 2210 WASTE MOD. 3820 150 ø 228 MOD. 3510 MOD. 2710 14 15

USE Series of Eyewashes specially designed for their installation in laboratories, directly on the work table itself. MATERIALS Galvanized steel piping. Brass fittings. COATING Anti-corrosive polyamide 11 in high-visibility yellow. WATER INLET G 1/2" BSP. Maximum 8 bar. WATER INLET PRESSURE MOD. 3620-3720 3 bar. OPERATION Push handle, push button or swivel opening. HEADS Two high-flow aerated water spray heads at low pressure with automatic opening anti-dust cover. VALVE Full bore 1/2", regulated at 22 l/min, instant opening and manual closing. VALVE MOD. 3620-3720 Flow 20 l/min at 3 bar, instant opening and manual closing. EMERGENCY ES MOD. 2212 325 WASTE DRILL ø 50 190 390 115 100 G 1/2" ø DRILL ø 30 TABLE MOUNTING BOWL ABS BOWL MOD. 3500 350 100 290 190 190 G 1/2" DRILL ø 22 2212 2212 SS 100 3500 3620 2215 SS TABLE RECESSED WITHOUT BOWL SWIVEL WITHOUT BOWL 90º TURN OPENING MOD. 3620 G 1/2" DRILL ø 22 MOD. 2215 SS 3720 SWING OUT WITHOUT BOWL 120 160 ø 270 ø 50 G 1/2" 100 WASTE G 1/2" DRILL ø 22 DRILL ø 22 DRILL ø 260 40 MOD. 3720 220 16 17

DRENCH HOSE USE Manual Eyewashes with 1.5 m long flexible tube, with one or two high-flow aerated water spray heads at low pressure. To be used in industry, laboratories, schools, etc. RECESSED MOUNTING USE Indoor Eyewash recessed in the wall. Eyewash starts operating when you opening stainless steel door. MATERIALS Stainless steel flexible tube. Brass fittings. COATING Anti-corrosive polyamide 11 in high-visibility yellow. WATER INLET G 1/2" BSP. Maximum 8 bar. WATER INLET PRESSURE MOD. 2275 3 bar. OPERATION Lever or cabinet handle. HEADS One or two high-flow aerated water spray heads at low pressure with automatic opening anti-dust cover. VALVE Regulated at 15 l/min (one spay head) or 22 l/min (two spray heads), instant opening and manual closing. VALVE MOD. 2275 Flow 20 l/min at 3 bar, instant opening and manual closing. EMERGENCY ES MOD. 190030 MOD. 3100 DRENCH HOSE ES 3000 3100 3110 3120 3130 190030 WALL WITH SINGLE HEAD WALL WITH SINGLE HEAD AND WALL FEEDING BRACKET WALL WITH DOUBLE HEAD AND WALL FEEDING BRACKET TABLE WITH SINGLE HEAD TABLE WITH DOUBLE HEAD OPTIONAL NON-RETURN VALVE RECESSED MOUNTING MODEL 2275 WALL MOD. 3000 MOD. 2275 383 180 200 150 342 ø 55 MAX. 50 DRILL ø 42 358 OPTIONAL: NON-RETURN VALVE FLEXIBLE HOSE 1,5 M LENGTH WASTE G 1" 1/2 399 G 1/2" MOD. 3120 MOD. 3130 18 19

USE In outdoor and indoor facilities the Emergency Showers are activated by pulling the lever. MATERIALS Galvanized steel piping. Brass fittings. COATING Anti-corrosive polyamide 11 in high-visibility yellow. OPERATION Pull handle. VALVE Full bore 1", regulated at 110 l/min, instant opening and manual closing. INSTALLATION Height assembly see pag. 42. WATER INLET G 1" BSP or BSP. Maximum 8 bar. EMERGENCY S FLOOR MOUNTING HEAD ABS 1120 415 HEAD 1120 SS 605 ø 760 PEDESTAL MOD. 1100 CEILING MOUNTING HEAD ABS 1100 760 HEAD 1100 SS G 1" ø VERTICAL 100 2100 285 WALL MOUNTING HEAD ABS HEAD 1110 1110 SS HORIZONTAL 560 165 G 1" ø 760 ø 228 150 MOD. 1110 MOD. 1120 20 21

OVER DOOR USE In indoor facilities the Emergency Showers are installed over a door or emergency exit. RECESSED MOUNTING USE Indoor Shower recessed in the wall. Shower starts operating when you lower the lever. MATERIALS Galvanized steel piping. Brass fittings. COATING Anti-corrosive polyamide 11 in high-visibility yellow. WATER INLET G 1" BSP. Maximum 8 bar. OPERATION Pull handle or cabinet lever. VALVE Full bore 1", regulated at 110 l/min, instant opening and manual closing. INSTALLATION Height assembly see pag. 42. EMERGENCY S RECESSED MOUNTING HEAD ABS 1275 HEAD 1275 SS RECESSED 650 780 G 1" OVER DOOR HEAD ABS HEAD 1141 1141 SS 1142 1142 SS MOD. 1141 EMERGENCY RIGHT CONTROL 760 EMERGENCY LEFT CONTROL ACCORDING TO INSTALLATION ø OPTIONAL PIPE 70 142 252 212 ø 570 182 G 1" MOD. 1275 22 23

USE Series of Emergency Showers and Eyewashes completely constructed of stainless steel to be installed in food industries, nuclear energy, etc. The models combine the Shower and Eyewashes between them, minimizing the required space, and using a sole water inlet for both pieces of equipment. MATERIALS Stainless steel piping and fittings. WATER INLET G 1" BSP or BSP. Maximum 8 bar. OPERATION Pull handle. VALVE Full bore 1", regulated at 110 l/min, instant opening and manual closing. OPERATION Push handle or foot treadle. VALVE Full bore 1/2", regulated at 22 l/min, instant opening and manual closing. INSTALLATION Height assembly see pag. 42. S AND ES S AND ES 4220 TI 4 TI 4260 TI 4285 TI 415 2100 1125 PULL ROD, PUSH HANDLE, FLOOR MOUNTING PULL ROD, PUSH HANDLE AND FOOT TREADLE, FLOOR MOUNTING PULL ROD, PUSH HANDLE WITHOUT BOWL, WALL MOUNTING PULL ROD, PUSH HANDLE, WALL MOUNTING ø 260 605 ø 260 760 180 WASTE 1635 S 1100 TI VERTICAL, CEILING MOUNTING 1110 TI HORIZONTAL, WALL MOUNTING 1120 TI PEDESTAL, FLOOR MOUNTING MOD. 1100 TI 415 550 ø 260 760 G 1" ø 238 140 MOD. 1110 TI MOD. 4220 TI MOD. 4260 TI 24 25

USE Series of Emergency Eyewashes and Booth Stations completely constructed of stainless steel to be installed in food industries, nuclear energy, etc. MATERIALS Stainless steel piping and fittings. WATER INLET G 1/2" BSP (Eyewash) or BSP (Cabin). Maximum 8 bar (Eyewash) or 4 bar (Cabin). OPERATION Pull handle or platform. PLATFORM VALVE 1" 1/4, automatic opening and closing, automatic drain. OPERATION Platform or pull handle. VALVE Full bore 1", regulated at 110 l/min, instant opening and manual closing. OPERATION Push handle, foot treadle or platform. VALVE Full bore 1/2", regulated at 22 l/min, instant opening and manual closing. INSTALLATION Height assembly see pag. 42. S AND ES MOD. 2210 TI ES 2210 TI 2220 TI 2710 TI 3510 TI ø 260 WALL WITH BOWL PEDESTAL WITH BOWL PEDESTAL WITH BOWL AND FOOT TREADLE WITHOUT BOWL 190 230 MOD. 2220 TI PLATFORMS 4700 TI 4710 TI 4720 TI 4730 TI 4750 TI 2140 1180 EMERGENCY AND DOUBLE PLATFORM SEPARATE OPERATION PLATFORM, HEAD ABS EMERGENCY AND PLATFORM SIMULTANEOUS OPERATION EMERGENCY AND PLATFORM INDEPENDENT OPERATION PLATFORM ø 260 160 410 760 800 1030 AND AUTOMATIC DRAIN WASTE G 1/2" 850 MOD. 3510 TI MOD. 4730 TI 26 27

USE The Self-draining Showers platforms in external facilities is completely automatic when a person enters the platform. Automatic drain valve for residual water. When standing on the platform the water enters the supply pipe to the Shower or Eyewash. When exiting after use, the residual water drains via the automatic drain valve thus preventing the system from freezing. MATERIALS Galvanized steel piping. Brass fittings. COATING Anti-corrosive polyamide 11 in high-visibility yellow. WATER INLET G 1/2" BSP or BSP. Maximum 4 bar. PLATFORM VALVE 1" 1/4, automatic opening and closing, automatic drain. OPERATION Platform or pull handle. VALVE Full bore 1", regulated at 110 l/min, instant opening and manual closing. OPERATION Platform. VALVE Full bore 1/2", regulated at 22 l/min, instant opening and manual closing. HEADS Two high-flow aerated water spray heads at low pressure with automatic opening anti-dust cover. SELF-DRAINING S AND ES MOD. 4700 PLATFORMS S AND ES HEAD ABS 4700 PLATFORMS S AND ES BOWL ABS 4750 ø HEAD 4700 SS BOWL 4750 SS 800 230 EMERGENCY AND DOUBLE PLATFORM SEPARATE OPERATION PLATFORM 980 G 1/2" AND AUTOMATIC DRAIN HEAD ABS HEAD 4720 4720 SS 4730 4730 SS EMERGENCY AND PLATFORM SIMULTANEOUS OPERATION EMERGENCY AND PLATFORM INDEPENDENT OPERATION MOD. 4720 2100 415 ø 800 760 410 165 1160 1030 WASTE 1030 100 1170 AND AUTOMATIC DRAIN 850 MOD. 4730 850 MOD. 4750 28 29

USE The Self-draining Showers platforms in external facilities is completely automatic when a person enters the platform. Automatic drain valve for residual water. The Self-draining Showers floor mounting are provided with drain valves which are activated after pushing the handle. MATERIALS Galvanized steel piping. Brass fittings. COATING Anti-corrosive polyamide 11 in high-visibility yellow. WATER INLET BSP. Maximum 8 bar. (4 bar for platforms). PLATFORM VALVE 1" 1/4, automatic opening and closing, automatic drain. OPERATION Push handle, foot treadle or platform. VALVE Full bore 1", regulated at 110 l/min, instant opening and manual closing. OPERATION Push handle or foot treadle. VALVE Full bore 1/2", regulated at 22 l/min, instant opening and manual closing. HEADS Two high-flow aerated water spray heads at low pressure with automatic opening anti-dust cover. SELF-DRAINING S AND ES FLOOR MOUNTING HEAD/BOWL ABS HEAD/BOWL 4252 4252 SS 4253 4253 SS SIMULTANEOUS OPERATION FOOT TREADLE OPERATION INDEPENDENT OPERATION, PUSH HANDLE FOR, HANDLE OR FOOT TREADLE FOR MOD. 4252 SS 2100 ø 510 AUTOMATIC DRAIN ø PLATFORM S MODEL 4710 PLATFORM, HEAD ABS MODEL 4710 SS PLATFORM, HEAD DECONTAMINATION BOOTH MODEL 4810 PLATFORM WITH 14 SPRAYS MOD. 4710 730 14 NOZZLES 630 2170 1130 AUTOMATIC DRAIN 1010 AND AUTOMATIC DRAIN WASTE 150 1030 100 MOD. 4253 MOD. 4810 850 30 31

USE In outdoor facilities with extreme low or high temperatures. The floor equipment uses underground valves with automatic drains. The wall equipment is supplied inside the building. When the operating lever is pushed, the water enters the supply pipe to the Shower or Eyewash, when closing the valve after use the residual water drains via the automatic drain valve thus preventing the system from freezing. MATERIALS Galvanized steel piping. Brass fittings. COATING Anti-corrosive polyamide 11 in high-visibility yellow. WATER INLET G 1/2" BSP, G 1" BSP or BSP. Maximum 8 bar. / OPERATION Pull lever handle/push handle. VALVE Full bore 1" or 1" 1/4, regulated at 110 l/min, instant opening and manual closing, automatic drain. HEADS Two high-flow aerated water spray heads at low pressure with automatic opening anti-dust cover. VALVE Full bore 1/2", regulated at 22 l/min, instant opening and manual closing, automatic drain. INSTALLATION Height assembly see pag. 42. SELF-DRAINING S AND ES UNDERGROUND FLOOR MOUNTING HEAD ABS 1120 FP 1120 FP/SS 2220 FP HEAD TEMPERATURE PROTECTION TEMPERATURE PROTECTION 2100 255 1000 FLOOR LINE FROST LINE 520 ø 150 780 1000 1025 FLOOR LINE FROST LINE 190 150 745 INTERIOR WALL MOUNTING HEAD ABS MOD. 1110 FP HEAD 1110 FP 1110 FP/SS BOWL ABS BOWL 2210 FP 2210 FP/SS TEMPERATURE PROTECTION TEMPERATURE PROTECTION 260 ø 190 ø 860 345 750 G 1" AUTOMATIC DRAIN AND AUTOMATIC DRAIN G 1/2" AND AUTOMATIC DRAIN WASTE 415 G 1/2" MOD. 1120 FP MOD. 2220 FP MOD. 2210 FP 32 33

USE In outdoor facilities with extreme low or high temperatures. The operation of Decontamination Booths is completed when a person enters the platform. The equipment uses underground valves with automatic drains. When standing on the platform the water enters the supply pipe to the Shower or Eyewash. When exiting after use, the residual water drains via the automatic drain valve thus preventing the system from freezing. MATERIALS Galvanized steel piping. Brass fittings. COATING Anti-corrosive polyamide 11 in high-visibility yellow. WATER INLET G 1/2" BSP or BSP. Maximum 8 bar. PLATFORM VALVE 1" 1/4, automatic opening and closing, automatic drain. / OPERATION Pull lever handle, push handle or platform. VALVE Full bore 1" or 1" 1/4, regulated at 110 l/min, instant opening and manual closing, automatic drain. HEADS Two high-flow aerated water spray heads at low pressure with automatic opening anti-dust cover. VALVE Full bore 1/2", regulated at 22 l/min, instant opening and manual closing, automatic drain INSTALLATION Height assembly see pag. 42. SELF-DRAINING S AND ES UNDERGROUND PLATFORM HEAD ABS 4710 FP 4720 FP HEAD 4710 FP/SS 4720 FP/SS 4730 FP 4730 FP/SS 4750 FP 4810 FP 2145 850 ø 460 PLATFORM EMERGENCY AND PLATFORM SIMULTANEOUS OPERATION EMERGENCY AND PLATFORM INDEPENDENT OPERATION PLATFORM WITHOUT BOWL PLATFORM WITH 14 SPRAYS 800 1030 FLOOR LINE MOD. 4222 FP 2100 1080 760 515 ø ø UNDERGROUND FLOOR MOUNTING MODEL 4222 FP TEMPERATURE PROTECTION / BOWL ABS, SIMULTANEOUS OPERATION MODEL 4222 FP/SS TEMPERATURE PROTECTION /, SIMULTANEOUS OPERATION MODEL 4223 FP TEMPERATURE PROTECTION / BOWL ABS, INDEPENDENT OPERATION MODEL 4223 FP/SS TEMPERATURE PROTECTION /, INDEPENDENT OPERATION 775 FROST LINE 1000 AUTOMATIC DRAIN FROST LINE 1000 1000 MOD. 4710 FP MOD. 4223 FP G 1/2" AND AUTOMATIC DRAIN FROST LINE AND AUTOMATIC DRAIN 34 35

USE Overhead Tank Showers are designed for remote location with inadequate water supply providing necessary water by gravity up to 15 min. according to standard. In addition for extreme temperatures environment (hot/freeze conditions) are designed Underground Tank Showers. After use, pipes remain empty preventing the system from heat and freezing. Therefore, expensive chiller and heating systems are not required. OVERHEAD TANK MATERIALS Tank, structure & piping in stainless steel. TANK CAPACITY 1500 L. WATER FILLING G 1 BSP. OVERFLOW INTEGRATED OPERATION Pull handle. OPERATION Push handle. UNDERGROUND TANK MATERIALS Tank in polyethylene, shower platform in galvanized steel piping with anti-corrosive polyamide 11 coating. Brass fittings. TANK CAPACITY 2000 L. ADJUSTABLE DOME SHAFT WATER FILLING Large oval lid, safe to walk on. ELECTRICAL Submersible pump 230V 1.5Kw. Control box 230V /24V with platform limit switch. TANK S OVERHEAD TANK 4820 TI/TS 4830 TI/TS EMERGENCY AND WITH OVERHEAD TANK EMERGENCY WITH OVERHEAD TANK OPTIONS MODEL 196001 INLET FLOAT VALVE FOR AUTOMATIC TANK FILLING MODEL 196002 VISUAL SIDE INDICATOR OF TANK LEVEL MODEL 196003 ELECTRIC HEATER WITH ADJUSTABLE THERMOSTAT FOR COLD WEATHER (T<15º C) MODEL 196004 THERMAL INSULATION FOR HOT (T>37º C) OR COLD (T<15º C) WEATHER MODEL 196005 ACTIVATION SWITCH TO SEND SIGNAL TO CONTROL ROOM MODEL 196006 ACTIVATION SWITCH TO SEND SIGNAL TO CONTROL ROOM UNDERGROUND TANK 4710 TS/FP 4720 TS/FP 4730 TS/FP PLATFORM WITH UNDERGROUND TANK / PLATFORM WITH UNDERGROUND TANK, SIMULTANEOUS OPERATION / PLATFORM WITH UNDERGROUND TANK, INDEPENDENT OPERATION 2400 G 1" FLOOR LINE 850 3666 FROST LINE 2600 ø 1260 1120 1120 2150 MOD. 4820 TI/TS MOD. 4720 TS/FP 36 37

ACCESSORIES TEMPERED WATER In order to avoid thermal shock it is possible to include a thermostatic mixer in the Shower and Eyewash, specifically designed for Emergency Equipment that supply tempered water. Standards recommends temperatures between 15º C - 37º C. The valve mixes cold and hot water inlets to deliver tepid water at the desired temperature. On failure of hot water supply, internal cold water by-pass delivers cold water supply. On failure of cold water supply, hot water is shut down to prevent any damage on the user. SPECIFICATIONS MODEL 195120 Adjustable temperature knob regulator, from 20 to 43º C. Maximum hot water supply temperature: 100º C. For optimum performance, 50-70º C. Maximum cold water temperature 23º C for optimum performance, 5-10º C. Minimum hot and cold water supply pressure: 2 bar. Recommended 3 bar. Maximum supply pressure is 8 bar. G 1" male connections with check valves. Cold water by-pass flow rate 105 lpm at 2 bar. Tempered water flow rate 122 l/min at 2 bar. 134 G 1" G 1" MODEL 195120 THERMOSTATIC SAFETY VALVE 100 112 60 56 TEMPERATURE PROTECTION Thermal actuated valves continually sense the water and the ambient temperature and automatically bleed the Shower/Eyewash systems to establish flow until the over temperature water is eliminated. Operation: When the temperature exceeds safe limits, the thermal actuator modulates the valve open. A small quantity of water from the pipe system flows through the valve until the makeup water temperature returns to the safe range. SPECIFICATIONS Body and valves in stainless steel and actuator in brass. Supply and waste 1/2". MODEL 195110 Freeze protection valve Nominal pressure 2 bar. Maximum working pressure 8 bar. Temperature of maximum openinng 2º C. Full close temperature 7º C. MODEL 195112 Scald protection valve Nominal pressure 2 bar. Maximum working pressure 8 bar. Temperature of maximum openinng 37º C. Full close temperature 29º C. MODEL 973010 CONNECTOR 1/2" FOR 1 VALVE MODEL 973985 TE 1/2" FOR 2 VALVES MODEL 191043 TE 1/2" FOR 1 VALVE SPECIFICATIONS MODEL 195020 Adjustable temperature regulator set for 29º C, high temperature limit stop set for 32º C. Termomether display. Recommended hot inlet temperature, 60º C. Minimum hot and cold water supply pressure: 2 bar. Maximum supply pressure is 8 bar. male connections with check valves. Cold water by-pass flow rate 105 lpm at 2 bar. Tempered water flow rate 350 l/min at 2 bar for multiple Showers/Eyewash. MODEL 195110 FREEZE PROOF VALVE MODEL 195112 ANTI SCALD VALVE MODEL 190700 TE 1" 1/4 FOR 1 VALVE 305 mm G 1" 1/2 PRESSURE PROTECTION STOP SCREW LIMIT TEMPERATURE ADJUSTABLE SCREW For optimum usage of the Emergency Equipment it is advised to maintain water pressure under recommended values to avoid premature wear of components, unnecessary strain for users and damage to the installation. For pressures above 4 bar or 8 bar depending on equipment it is recommended the use of a pressure reduction valve. MODEL 950 PRESSURE REDUCTION VALVE FOR MAX. INLET PRESSURE 25 BAR AND WITH OUTLET ADJUSTED PRESSURE 3 BAR MODEL 195020 THERMOSTATIC SAFETY VALVE 150 38 39

BOOTH STRUCTURE Made from coated steel to be fastened on the floor. The three sides are closed by PMMA panels in high-visibility yellow. The structure reduces the thermal shock, and protects from the wind and cold. PLATFORM Accessory to activate all to the platform Showers, models 1120-4220 - 4230-4 - 4260, and close the Shower by a lever. TEST Essential for flow control of the Emergency Shower Stations. Made of plastified PVC. ALARM Visual and audible alarm is activated when the water flows through the piping while the Emergency Equipment is in use. Optionally, it send an operation signal to the control or emergency room of the facility. Installation must be carried out by qualified personnel. WATER PRESSURE Optimum 2 bar. Minimum 1,5 bar. Maximum 8 bar. ACCESSORIES KIT ALARMA ALARM KIT FOR NON EXPLOSIVES ATMOSPHERES 220-240 VAC 50/60 Hz (Schuko connection). IP43 Protection. FLOWSWITCH Max swichting voltage 230 VAC, 48 VDC. Max swichting current 1 A. Connecting cable lenht 1.5 m, 2 x 1 mm 2. VISUAL AND AUDIBLE ALARM Orange flashing light 110 flash/min. Continous sound 92 db. MODEL 195003 TEST FOR MODEL 195030 ALARM KIT FOR SAFE AREAS MODEL 190614 FLOWSWITCH FOR SAFE AREAS ALARM KIT FOR EXPLOSIVES ATMOSPHERES 220-240 VAC 50/60 Hz. Group II, Zone 1, Category 2G. Other classifications available upon request. FLOWSWITCH Max swichting voltage VAC/VDC. Max swichting current 5 A AC/1 A DC. VISUAL ALARM Orange flashing light up to configurable 120 flash/min. AUDIBLE ALARM Continous sound, regulable 90-110 db. MODEL 194740 STRUCTURE FOR DECONTAMINATION BOOTH AND PLATFORM S MODEL 194900 PLATFORM FOR 1120-4220 - 4230-4 - 4260 MODEL 190121 WALL SUPPORT MODEL 1110 MODEL 195040 ALARM KIT FOR EXPLOSIVE ATMOSPHERES MODEL 950634 FLOWSWITCH FOR EXPLOSIVE ATMOSPHERES 40 41

EMERGENCY AND The following are the basic installation standards for Emergency Equipment. INSTALLATION AND MAINTENANCE INSTRUCTIONS INSTALLATION EMERGENCY EQUIPMENT LOCATION The location of Emergency Equipment should comply with the following conditions: It should be installed in places that are highly-visible and easily accessed from at least in three directions. It should be installed in those areas where there is danger, and should not be more than 10 seconds away from the area where accidents can occur. Where there is an immidiate risk from concentrated chemicals, equipment should be adjacent to the risk. It should be placed at the same level as the source of danger, without any obstruction in the path to the Emergency Equipment, such as doors, trip hazards, steps or matting, etc.. WATER The water supply to the Emergency Equipment should comply with the following conditions: It should be supplied from the main or the emergency piping. The diameter of the supply tube should be at least G 1" BSP. An inlet pressure of 2 bar is recommended for the Emergency Equipment. For correct operation, the minimum pressure is 1.5 bar, and the maximum pressure is 4 bar or 8 bar depending on equipment. ASSEMBLY It is recommended to assemble the Emergency Equipment as indicated by the assembly drawing. The necessary means are as follows: Pipe sealings. Tools to fasten the equipment to the surface. It is recommended to install the Emergency Showers that are not fastened to the ground at a height where the spray head is between 210 and 230 cm above the level where the user will stand. It is recommended to install the Emergency Eyewashes that are not fastened to the ground at a height where the output nozzles of the Eyewashes are between 90 and 110 cm above the level where the user will stand. A water temperature between 15º C and 37º C is recommended. It is recommended to install a filter, as well as to drain the piping before installing the Emergency Equipment. Potable water, or of similar quality is required. Drainage system are recommend for Eyewash and floordrains for Showers in order to avoid hazard or slippery surfaces. After use waste water may be connected waste disposal system or neutralization tank. OPERATION ACTIVATION In case of accident, the injured person should shower or wash his/her eyes IMMEDIATELY for a minimum of 15 minutes. The Emergency Equipment is quickly activated as follows: The Emergency Eyewashes pushing the paddle backwards or by stepping on the foot pedal. The Emergency Showers by pulling the triangular lever. The manual equipment by pushing the lever. Suitable medical assistance should be sent IMMEDIATELY. SIGNS PLATES Each piece of equipment that we manufacture is provided with a plate or sign to signal the unit (except in the table assembly models). The plates are photoluminescent, with a green background, and white text. Dimensions: 210 x 297 mm MAINTENANCE MODEL 191004 MODEL 191005 MAINTENANCE AND TRAINING The operation of the Emergency Showers and Eyewashes should be verified at least ONCE a week in order to guarantee the water supply and to prevent the proliferation of microbes. Fill out the maintenance table supplied (Model 190190) or a similar one. Personnel should be trained as follows: The location and signaling of the Emergency Equipment. The operation of the Emergency Showers and Eyewashes. The manner of notifying the healthcare personnel. Maintenance to be performed on the Emergency Equipment as described above. MODEL 191006 MODEL 190190 42 43

We have a wide range of spare parts for all the Emergency Shower and Eyewashes models. ASK ABOUT AVAILABILITY OF OTHER SPARE PARTS SPARE PARTS MODEL 190100 HEAD ABS HIGH VISIBILITY YELLOW G 1" MODEL 190112 HEAD ABS HIGH VISIBILITY YELLOW G 1" 1/2 MODEL 192100 HEAD STAINLESS STEEL G 1" MODEL 192112 HEAD STAINLESS STEEL G 1" 1/2 MODEL 190150 ABS HIGH VISIBILITY YELLOW BOWL MODEL 191150 BOWL MODEL 190131 COMPLETE FOOT CONTROL ASSEMBLY MODEL 190123 HEAD COVER MODEL 190135 HEAD MODEL 190145 VALVE G 1/2" BSP MODEL 192145 VALVE G 1/2" BSP WITH DRAIN MODEL 192148 DOUBLE EMERGENCY MODEL 190146 PUSH HANDLE PLASTIC MODEL 193146 PUSH HANDLE ALUMINIUM MODEL 190136 HEAD ASSEMBLY IN ABS MODEL 193136 HEAD ASSEMBLY IN BRASS MODEL 190108 VALVE G 1" BSP MODEL 192108 VALVE G 1" BSP WITH DRAIN MODEL 190106 HANDLE MODEL 190148 EMERGENCY MODEL 190125 BRACKET MODEL 190109 WALL BRACKET MODEL 191136 HEAD ASSEMBLY IN MODEL 190400 FP VALVE BSP WITH DRAIN MODEL 190401 FP VALVE G 1/2" BSP WITH DRAIN MODEL 190160 WALL BRACKET WITH WATER INLET MODEL 190105 PULL ROD 1,5 M FLEXIBLE STAINLESS STEEL HOSE MODEL 190149 FOR SINGLE MODEL 190151 FOR DOUBLE MODEL 190402 PLATFORM VALVE WITH DRAIN BSP 44

DIRECTORY CODE 1100 1100 SS 1100 TI 1110 1110 FP 1110 FP/SS 1110 SS 1110 TI 1120 1120 FP 1120 FP/SS 1120 SS 1120 TI 1141 1141 SS 1142 1142 SS 1275 1275 SS 2210 2210 FP 2210 FP/SS 2210 SS 2210 TI 2212 2212 SS 2215 SS 2220 2220 FP 2220 SS 2220 TI 2230 2230 SS 2240 2240 SS 2275 2710 2710 SS 2710 TI 3000 3100 3110 3120 3130 3500 3510 3510 TI 3620 3720 PAGE 21 21 25 21 33 33 21 25 20 32 32 20 25 22 22 22 22 23 23 14 33 33 14 26 16 16 16 15 32 15 26 14 14 15 15 19 15 15 26 18 18 18 18 18 16 14 26 16 16 CODE 3820 4220 4220 SS 4220 TI 4221 4221 SS 4222 FP 4222 FP/SS 4223 FP 4223 FP/SS 4225 4225 SS 4230 4230 SS 4 4 SS 4 TI 4252 4252 SS 4253 4253 SS 4255 4255 SS 4260 4260 SS 4260 TI 4275 4275 SS 4280 4280 SS 4285 4285 SS 4285 TI 4290 4290 SS 4295 4295 SS 4700 4700 SS 4700 TI 4710 4710 FP 4710 FP/SS 4710 SS 4710 TI 4710 TS/FP 4720 4720 FP 4720 FP/SS PAGE 14 8 8 24 11 11 35 35 35 35 11 11 8 8 9 9 24 30 30 30 30 9 9 10 10 24 13 13 12 12 12 12 24 12 12 12 12 28 28 27 31 34 34 31 27 37 29 34 34 CODE PAGE CODE PAGE 4720 SS 29 192100 44 4720 TI 27 192108 44 4720 TS/FP 37 192112 44 4730 29 192145 44 4730 FP 34 192148 44 4730 FP/SS 34 193136 44 4730 SS 29 193146 44 4730 TS/FP 37 194740 40 4730 TI 27 194900 40 4750 28 195003 41 4750 FP 34 195020 38 4750 SS 28 195030 41 4750 TI 27 195040 41 4810 31 195110 39 4810 FP 34 195112 39 4820 TI/TS 36 195120 38 4830 TI/TS 36 196001 36 190030 18 196002 36 190100 44 196003 36 190105 44 196004 36 190106 44 196005 36 190108 44 196006 36 190109 44 950 39 190112 44 950634 41 190121 41 973010 39 190123 44 973985 39 190125 44 190131 44 190135 44 190136 44 190145 44 190146 44 190148 44 190149 44 190150 44 190151 44 190160 44 190190 43 190400 44 190401 44 190402 44 190614 41 190700 39 191004 43 191005 43 191006 43 191043 39 191136 44 191150 44

CGE.UK.2018 LABORATORY TAPS AND SAFETY S - ES HEAD OFFICE Compositor Narvaez, 1O P. I. CAN JARDI O8191 RUBI (Barcelona) SPAIN Telephone +34 935 860 780 Fax +34 936 973 226 info@carlosarboles.com copyright 2018 CARLOS ARBOLES S.A LABORATORY TAPS AND SAFETY S - ES Unit 56, Evans Business Centre, Manchester Road, Bolton, BL3 2NZ Tel. 0044(0)1204 388814 Fax 0044(0)1204 388813 sales@arboles.co.uk DISTRIBUTOR: Finland info@labralvi.fi +358 400 164 594