Certificate of Compliance

Similar documents
for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

IECEx Certificate of Conformity

Certificate of Compliance

Certificate of Compliance

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Certificate of Compliance

IECEx Certificate of Conformity

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

srra, of Conformity IECEx Gert f cate ?-ot,b

DB5 Intrinsically Safe Sounder Type DB-5

Certificate of Compliance

IECEx Certificate of Conformity

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

4) Intrinsic Safety Certification

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Certificate of Compliance

Certificate of Compliance

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

Mark* VIe and Mark VIeS Control Systems Equipment in Hazardous Locations (HazLoc) Instruction Guide

INSTRUCTION MANUAL. Frequency-Pulse Converter, Repeater and Trip Amplifiers Din-Rail Model D1060S D1060S

Certificate of Compliance

Product Information to the manual

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Certificate of Compliance

Tank Gauging System Special Safety Instruction

Operating Instructions Edition 02/2007

FAHM Co. Temperature Transmitter PTT74 Series

Intrinsically Safe Flame Detector Installation Guide

Certificate of Compliance

Certificate of Compliance

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

SET-2000 Oil/Sludge 12 VDC

Annubar Flowmeter Series

Instrumentation Products and Applications

Declaration of conformity

Technical Data. Dimensions

Certificate of Compliance

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

General Specifications

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

CERTIFICATE OF COMPLIANCE HAZARDOUS LOCATION ELECTRICAL EQUIPMENT PER CANADIAN REQUIREMENTS

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

BA374C Intrinsically safe field mounting indicating temperature transmitter

E2S Datasheet v10a

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

OOH740-A9-Ex Multi-sensor fire detector

EU DECLARATION OF CONFORMITY

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

OOH740-A9-Ex Multisensor fire detector

SET Installation and Operating Instructions. Level switch for one sensor

Today's world of increasing

FDOOT241-A9-Ex Multisensor fire detector

Intrinsically Safe Solutions

PumpSaver ISS-105 IS Super Cell Installation Guide

Rosemount 3490 Series

Certification Supplement Manual

Rosemount 752 Fieldbus Remote Indicator

Certificate of Compliance

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Installation Manual. 1. Introduction. 2. Handling Cautions. 3.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Manual Isolating Barrier D461R1 (Revision 01)

SET-2000 Hi Level/Oil

Solar Separator Alarm Type Installation, Operation & Maintenance

Model 144H. Product Data Sheet , Rev DB February Content

Certification Supplement Manual

Inductive slot sensor

Certificate of Compliance

RT FLOW RATE TOTALISER

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.

BA488CF Intrinsically safe Panel mounting Fieldbus Display

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

SOLAR SEPARATOR ALARM

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

PROTEUS Series OEL8000III-K. Tank Gauging System. Installation Manual

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

Technical Data. Dimensions

Certificate of Compliance

INSTRUCTION MANUAL (ATEX)

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Certificate of Compliance

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

OilSET-1000 (12 VDC)

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

Transcription:

Certificate of Compliance Issued to: GE Intelligent Platforms 240 The Village Butterfield Business Park Bedfordshire, Luton LU2 8DL United Kingdom Attention: John Purdy The products listed below are eligible to bear the CSA Mark shown Issued by: Rawn Murphy Rawn Murphy PRODUCTS CLASS 2258 04 - PROCESS CONTROL EQUIPMENT - Intrinsically Safe, Entity - For Hazardous Locations Ex na [ia] IIC: 8000 Series Process Control I/O System, (Suitable for use in Class I, Zone 2, Group IIC); consisting of Module Carrier, Field Terminal Assemblies, Carrier Extension Assemblies, Power Supply, Railbus Isolator and I/O Modules; input rated 18.5-36V dc max, 5A (per Power Supply); Max. Ambient 70 Deg. C; Modules indicated, provide intrinsically safe circuits with Entity Parameters, when connected as per installation drawing. System components are as listed below: Model Description Inst. Drawing # Temperature Code 8720-CA-04 Carrier --- 8727-CA-08 Carrier --- 8729-CA-08 Carrier --- 8723-CA-RB Railbus Isolator Carrier --- 8725-CA-RB Railbus Isolator Carrier --- 8724-CA-PS PSU Carrier --- 8621-FT- Field Terminal --- 8622-FT- Field Terminal --- 8623-FT- Field Terminal --- DQD 507 Rev. 2009-09-01 Page: 1

8624-FT- Field Terminal --- 8625-FT- Field Terminal --- 8626-FT- Field Terminal --- 8030-CE-RH I.S. Carrier Extender RH --- 8031-CE-LH I.S. Carrier Extender LH --- 8920-PS-DC Power Supply SCI-842 8922-RB- Railbus Signal Isolator SCI-843 Module Desc. T-Code Inst. DWG Entity Parameters Model # 8201-HI- 8-Chl AnalogIn w/hart) SCI-838 TerminalsUo (V) Io (ma) Po (W) Groups Co (uf) Lo (mh) Each pair 28 93 0.65 IIC 0.13 3 8202- HO- 8-Chl. Analog Output w/hart SCI-964 IIB 0.39 9 IIA 1.04 24 Each pair 24.6 93 0.57 IIC 0.116 3.95 8204- AO- 8-Chl. Analog Output Mod. SCI-986 IIB 0.87 16.2 IIA 3.12 32.7 Each pair 24.6 93 0.57 IIC 0.116 3.95 IIB 0.87 16.2 IIA 3.12 32.7 DQD 507 Rev. 2009-09-01 Page: 2

8205-TI- 8-Chl. I.S. THC/ mv Input TerminalsUo (V) Io (ma) Po (W) Groups Co (uf) Lo (mh) 1-2, 3-4, 16.4* 63.7* 0.131 IIC 0.41 8.5 5-6, 7-8, SCI-1006 13-14, 15-16 9-10, 11-12 IIB 2.44 32.4 IIA 9.98 69.2 1.5 1.3 0.0005 IIC 1000 1000 8206-TI- 8215- DO- 8-Chl. I.S. RTD/ ohm Input 4 Ch. Sol. Driver SCI-1007 SCI-840 1-2-17-18, 3-4-19-20, 5-6-21-22, 7-8-23-24, 9-10-25-26, 11-12-27-28, 13-14-29-30, 15-16-31-32 IIB 1000 1000 IIA 1100 1000 16.4* 350* 0.718 IIC 0.39 0.3 IIB 2.47 1.3 IIA 9.96 2.42 Each pair 25 110 0.69 IIC 0.18 2.7 8220-DI- 8/16 Ch Sw. Prox. Detect. SCI-841 IIB 0.54 9 IIA 1.44 24 Each pair 10.5 14 0.04 IIC 2.67 176 DQD 507 Rev. 2009-09-01 Page: 3

IIB 8 633 IIA 21.3 1000 8230-AI- 8-Chl. Analog Input SCI-963 TerminalsUo (V) Io (ma) Po (W) Groups Co (uf) Lo (mh) Each pair 15.75 20 0.315 IIC 0.17 5 8223-PI- Digital Output Module SCI-966 1 and or 7 IIB 0.6 25 IIA --- --- 1.2 57.4 0.0172 IIC 1000 10.6 2 and or 8 IIB 1000 40.4 IIA 1000 87.1 9.56 1 0.0024 IIC 3.7 1000 3 and or 9 IIB 27 1000 IIA 255 1000 9.56 11.1 0.0264 IIC 3.7 263 5 and or 6 IIB 27 922 IIA 255 1000 27.4 93.2 0.639 IIC 0.08 3 11 and IIB 0.67 9 IIA 2.26 24 9.56 11.1 0.0264 IIC 3.7 263 DQD 507 Rev. 2009-09-01 Page: 4

2 + 5 and or 8 + 6 and IIB 27 922 IIA 255 1000 27.4 94.2 0.642 IIC 0.08 3 1 + 5 and or 7 + 6 and 27.4 * 151 * IIB 0.67 9 IIA 2.26 24 0.656 IIB 0.67 5.3 IIA 2.26 14.1 5 + 6 and 27.4 186.4 1.28 IIB 0.67 3.5 IIA 2.26 9.3 Ui (V) Ii (ma) Pi (W) Groups Ci (uf) Li (mh) 11 and 13 30 100 0.5 IIC, IIB, 0 0 or 15 and 16 IIA Notes: 1. This equipment is OPEN type equipment that must be installed in accordance with the manufacturer's instructions and used within a suitable end-use system enclosure in a Class I, Zone 2 or Class I, Division 2 hazardous location, or a non-hazardous location (Max Ambient 70 Deg C). The suitability of the enclosure is subject to investigation by the local Authority Having Jurisdiction at the time of installation. 2. The Modules provide intrinsically safe circuits for switches, thermocouples, non-inductive resistive devices or CSA Certified (Entity) equipment when installed per manufacturer's control drawings. DQD 507 Rev. 2009-09-01 Page: 5

3. Non-I.S. terminals of all 8000 System components must not be connected to any equipment that uses or generates in excess of 60 Vrms or DC unless the voltage is limited by an adequate means acceptable to the authority having jurisdiction. 4. Uo and Io parameters denoted with the asterisk (*) can not occur simultaneously; Uo represents the highest voltage of the either channel or of a combination of terminals; Io represents the current of the parallel combination of terminals. APPLICABLE REQUIREMENTS CAN/CSA Standard C22.2 No. 0-M91 (Reaffirmed General Requirements - Canadian Electrical Code, Part 2006) II CSA Standard C22.2 No. 142-M1987 (Reaffirmed Process Control Equipment 2004) CAN/CSA Standard E60079-0:07 Electrical Apparatus for Explosive Gas Atmospheres - General Requirements CAN/CSA Standard E60079-11:02 (Reaffirmed 2006) Electrical apparatus for explosive gas atmospheres, Part 11: Intrinsic Safety i CAN/CSA Standard E79-15-02 Electrical apparatus for explosive gas atmospheres, Part 15:Electrical Apparatus with type of protection "n" DQD 507 Rev. 2009-09-01 Page: 6