ALB30634 Air Operated Fuel Retriever

Similar documents
The sealless FLUX F 424

Models: GW/R-T GW/R-2-T GW/R-3-T

SAFETY AND OPERATING MANUAL

OPERATING & MAINTENANCE MANUAL

Page 1 of 18. Part# /5/2013

The sealless FLUX F 424

WARNING USER S MANUAL. Model iq 2000 Series Dust Collector with manual shaker

BEFORE OPERATING THE MACHINE: WARNING

Model K 3000 G Part No

Model K 5800 G Part No

2001 Smith Eastern Corporation

AC 1 AIR CONDITIONING SYSTEM

Vacuum cleaner Instruction manual

The Safest Connections...

Aerosol flame projector with spark effect Safety instructions and operating manual

OPERATING INSTRUCTIONS

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

OPERATING INSTRUCTIONS AND PART MANUAL. 9 Litre MANUAL & PNEUMATIC FLUID EXTRACTOR

Model K 4400 G Part No High Pressure Washer

GV 8 quart Model BP BATTERY POWERED BACKPACK VACUUM

USER GUIDE LET S GO. Bagless Cylinder. dirtdevil.com.au. Dirt Devil Service Line AU: / NZ:

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

EXTRACTOR Operation & Maintenance Manual

User Guide Vax Careline: AU: NZ:

hp Dust Collector With Vacuum Attachment

DynamoPower. vax.com.au vax.co.nz DYNAMIC POWERFUL PERFORMANCE, FOR TOTAL HOME CLEANING LET S GET STARTED. TOTAL HOME VX54

AirTM SERIES POWERFUL LIGHTWEIGHT FULL SIZE LET S GET STARTED. CCQSAV1P1 CCQSAV1T1 CCQSAV1C1 CCQSASV1P1 CCQSASV1T1 CCQSASV1C1

Heavy Duty Heater / Air Conditioner Model R-8545

OPERATING INSTRUCTIONS

WASH FILTER REGISTER FOR YOUR FREE 5 YEAR GUARANTEE TODAY OPERATING MANUAL ASSEMBLY. click. click. click. click. click. months

INSTRUCTIONS FOR SAFE USE INSTRUCTIONS FOR SAFE USE

INTRODUCTION SPECIFICATIONS. Pump Flow Curve

S150 S300 CONSTRUCTION HEATERS. Rev: August 15, 2008 SERVICE AND MAINTENANCE MANUAL No PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS

OPERATING INSTRUCTIONS

Instructions. Electronic Aquarium Water Change System. Replenishing Water. Extracting Water. Includes instructions for:

7165 Dust Collector Owner s Manual

DUST EXTRACTOR INSTRUCTION MANUAL. 550W (3/4 HP) INDUCTION MOTOR 1850W AUTOMATIC POWER OUTLET 65L COLLECTION BAG ø100mm X 2.

Tempest TP550/206 Petrol Pressure Washer

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

USER MANUAL. Q1a Q1b Q1c Q1* Q1* H. Q2a Q2d. Q2c M Q2b Q2* L P C B N** GP O** I. ** Certain models only, nozzles may vary according to model

OPERATIONS MANUAL REV A

Model HD 3501 Part No High Pressure Washer Operator Manual

FLAME GRILL GAS-FIRED (NAT & LPG) The Clay Oven Company Ltd. Leading manufacturers of clay ovens since 1974

Get Cleaning... What s your Vax s model number? User Guide. 2 in 1 Cordless Stick Vac VMST144V.

Contractor Worksheet Underground Fires Major Hazard Standard

ENVIROPRESS CAN CRUSHER Model : EP005 / EP005HD

evac User Manual March 2014 Prepared by: Gareth Wilson and Sinethemba Mngomezulu

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY

JOB EXTRACTOR OPERATIONS MANUAL REV A

Automatic Water System Pump SERIES

MODEL: SSAT-2L/6L SK

Gas Fire Patio Heater Q9

5HP CYCLONE DUST COLLECTOR MANUAL

Install Configurations

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

USER MANUAL KGNVCTBVAA

High Pressure Washer Operator Manual. Specifications Model HD 2700 DH/DB

HAND-OPERATED GREASE PUMPS 181

Bagless upright. Vax Careline (UK) (ROI) vax.co.uk VS-19EC. Vax model number:

WATER-HEATER FOR VEHICLES

Sip Vacuum Cleaner 1400/35 Wet & Dry

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings

Operating Instructions

User manual Flushing device VAS 6337/1a

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

MODEL 7000 SUCTION UNIT

Get Cleaning... User Guide Vax Service line AU: NZ: Bagged Cylinder What s your Vax s model number?

5 On/Off button 6 Function selector switch 7 Symbol - Eco function 8 Symbol - Standard heating function

SPECIFICATIONS MODEL NO. OZDE1015WA

Gas Fire Patio Heater Lhotse-817

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

CentroPelet ZV14 TECHNICAL INSTRUCTIONS HEATING TECHNIQUE. for regulation, use and maintenance of pellet stove

OWNER S MANUAL (English)

Installation Instructions

55-Gallon Dispenser Package

5 year guarantee SAVE THESE INSTRUCTIONS. Ensure you register for your 5 year guarantee today. ONLINE Just visit

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

INSTRUCTION MANUAL Vacuum Cleaner Model No.: VB-100

Operating Instructions

ORIGINAL OPERATING INSTRUCTIONS ASH VACUUM CLEANER / 18L

WET & DRY VACUUM 1250W 12L WARRANTY INSTRUCTION MANUAL SPECIFICATIONS VWD-1212 WHAT S IN THE BOX

2 000W CYCLONIC BAGLESS VACUUM

Drain, evacuate and recharge air conditioning, check for proper operation and check for leaks

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

Operation and Maintenance Manual

MRS-6 Maxi-Guard II. Model: C , 12, 13, 14 OPERATION SERVICE PARTS CARE. Revised 2/02

Operating instructions. Air heater Air Top Evo 40 Air Top Evo 55 for motor homes

GUH90 90 cm Canopy Hood

Before using your machine, you must familiarize yourself with all of its components.

FRANKE DESIGNER GAS COOKTOP 90CM

SECTION AUXILIARY HEATER

Designed in the UK. Rapide Ultimate. User Guide Vax Rapide Ultimate

WATER PUMP REQUESTED INFORMATION STANDARD PROCEDURE RAM Pickup 6.7L Eng 2500 STANDARD PROCEDURE - COOLANT AIR EVACUATION

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

HEATING AND AIR CONDITIONING

DUST EXTRACTOR MODEL No: CDE1000

Mobile Air Conditioner Instruction Manual Model TC-N9KM

SOLUS-500 EXTRACTOR 120V

Transcription:

ALB30634 Air Operated Fuel Retriever ONLY USE IN A WELL VENTILATED AREA OR WITH FUME EXTRACTION Read instructions and safety warnings before use of this product. The product should only be used in conjunction with your own Health & Safety manual & training. This product carries a 12 month warranty. Warranty is void if the instructions for use are not followed or if this product is modified in anyway. CAUTION fuel Retrieval In Progress We strongly suggest the use of a partable sign that should be ereceted when operating this machine. We can supply these at extra cost. JHM Butt & Co Ltd Station Yard Station Road Bawtry Doncaster South Yorkshire ON 10 6QD Tel: 01302 710868 Fax: 01302 719481

FUEL RETRIEVER SAFETY WARNINGS NEVER OPERATE NEAR NAKED FLAME OR IGNITION SOURCES ALWAYS OPERATE IN WELL VENTILATED AREA BEWARE OF FLAMMABLE VAPOUR WEAR PROTECTIVE CLOTHING INCLUDING ANTI-STATIC FOOTWEAR & SAFETY GOGGLES ALWAYS USE EARTHING EQUIPMENT SUPPLIED DISPOSE OF WASTE FUEL SAFELY WE STRONGLY SUGGEST THE USE OF A PORTABLE SIGN THAT INFORMS PASSERS BY THAT FLAMMABLE FUELS ARE NEARBY. CONTENTS: Fuel Retriever unit Handle assembly Suction tube & handle 5 x suction hoses Suction tube adapter 2 x earth wires with crocodile clips

BEFORE USE: Attach handle assembly to fuel retriever using 4 screws supplied in the holding brackets welded to side of fuel extractor unit. Attach appropriate male plug (to suit your shop air supply) MOST IMPORTANT 2 SETS OF EARTH WIRES WITH CROCIDILE CLIPS ARE SUPPLIED WITH THE UNIT. ONE SET MUST BE ATTACHED BETWEEN THE CAR & THE FUEL RETRIEVER, ONE SET MUST BE ATTACHED BETWEEN THE CAR & GROUND. NEVER CONNECT TO BATTERY OR POWER SOURCE REMOVING FUEL FROM VEHICLE Select a suitable suction hose from the 5 supplied. Attach to suction tube & handle using suction tube adapter Connect the suction tube to suction handle

Make sure ball valve on suction handle is in closed position, i.e., 90 degree to tube. Before connecting tank to air compressor valve make sure air inlet valve is closed Also ensure that the pressure release valve next to the regulator is in closed position Connect quick release coupling on air line to male plug on air inlet valve. Connect female coupling on suction handle to fuel inlet valve (next to oil filter).

Ensure function switch is in oil suction position. Open air inlet valve to create vacuum in tank (approx 15-25hg). NOTE THIS OPERATION WILL TAKE 2 3 MINUTES AIRLINE MUST BE CONNECTED AT ALL TIMES DURING OPERATION, OR VACUUM PRESSURE WILL BE DEPLETED Insert suction handle into fuel tank, ensuring it reaches below surface of the fluid. Open ball valve on suction handle and fuel will be extracted from vehicle and pumped into the storage tank. When fuel tank is empty, air will continue to be sucked into storage tank. This releases the vacuum created back to 0. As vacuum is released, close ball valve on suction handle. Close ball valve on air intake Allow vacuum to return to 0 Disconnect suction tube from suction handle. Return suction handle to retaining bracket. As suction hose is retrieved from vehicle fuel tank, wipe hose carefully with a cloth to remove any excess fuel. Return suction hose to hose container.

REMOVAL OF FUEL FROM STORAGE TANK Select a suitable container to collect the waste fuel. Make sure ball valve on suction handle is in closed position, i.e., 90 degree to tube. Before connecting tank to air compressor valve make sure air inlet valve is closed and also that pressure release valve is closed. Connect quick release coupling on suction handle to fuel outlet. Make sure function switch is in oil depletion position. Connect quick release coupling on air line to male plug on air inlet on tank

Insert end of suction handle into waste container. Open air inlet valve to approx 12 15 psi, then close valve. Open ball valve on suction handle gently. Fuel will be emptied into waste container immediately. Flow into waste container can be adjusted by adjusting ball valve handle. Close ball valve on suction handle. Release pressure in tank by opening up pressure release valve gently until pressure is released Close pressure release valve. Disconnect suction handle from fuel outlet. Replace suction handle in retaining bracket. Take care to wipe off any remaining fuel. Disconnect from air line.