MOUNTING DETAILS. Mounting Matrix / Details ENGINEER AND ARCHITECT SPECIFICATIONS CATALOG SHEET. 2-1/8 Deep

Similar documents
s Notification Appliances Mounting Options

MOUNTING ACCESSORIES. See Notes 1 & 8. See Note Thickness: 13/64 (A) UNIVERSAL MOUNTING PLATE (F) DOUBLE-GANG, FLUSH (BO) See Notes 4

Mounting Accessories. Notification. See Notes 1 & 8. See Note Thickness: 13/64. (a) universal mounting plate. (f) double-gang, flush (bo)

Mounting Accessories. Notification. See Notes 1 & 8. See Note Thickness: 13/64. (a) universal mounting plate. (f) double-gang, flush (bo)

Wheelock Notification Appliance Mounting Accessories

UL Online Certifications Directory

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

s Notification Appliances

Wheelock RSS & RSSP Series

Table 1: dba Ratings for AMT Multitone Signal Typical Anechoic dba at 10 Feet per CAN/ULC S525-07

'08 Series Notification A liances

*15cd models are Listed at 15cd and meet 75cd on axis

Air Duct Housings. Description

Protect. Alert. Inform.

1. POWERPATH Operation

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Fire Safety. Installation Instructions. Model RCC-2/R and RSE-1 Remote Control Centers OPERATION INTRODUCTION INSTALLATION

Vibratone Horns. Models 350 and 450

Table 1: Attenuation Rating Switch Position. Position Attenuation (db) Attenuation (db) (Approx.)

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

AND ARCHITECT SPECIFICATIONS

UL Online Certifications Directory

Sinorix Engineered Fire Suppression Systems For use with Novec TM 1230 Fire Protection Fluid and HFC-227ea

Analog fire panels FPA-1000 Family

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Life safety notification

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

DONALD H. BERG, ARCHITECT

Town of Cicero Local Code Amendments

TrueAlert Notification Appliances

Genesis LED G1 Series

Installation Instructions Model HZM

Desigo Fire Safety Marine Fire and Detection Equipment Models FH-2071-UM, BP-62 and USCG-HPLATE

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

INSTALLATION OF ACCESS FLOOR SYSTEMS IN GENERAL OFFICE AREA AND COMPUTER ROOM

Figure 1. Figure 2. See notes 1 and 2 below.

Siemens: Cerberus Division

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

Conceal-Alarm Series FA100 & FA900. ETL listed to UL standards UL1971, UL1480, UL464

1 Watt Supervised Self-Amplified Strobe Speakers Round Flush Grille with 75cd Strobe

Installation Instructions Model DLC

Dimensions of the Optional Mounting Box (BB-400R/W)

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

AND ARCHITECT SPECIFICATIONS

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

Installation Instructions Model ABHW-4S

The Advance You ve Been Looking For

AND ARCHITECT SPECIFICATIONS

Acoustical tee. Acoustical Tee

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms

MODELS ASHP, ASHH, ASUP, and ASUH

TrueAlert Multi-Candela Notification Appliances

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

MODELS 304GC, 304GCX, 314GC, and 314GCX

Installation Instructions Model SSD-C-REM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

good things in small packages

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

FIRE ALARM Submittal DR. PECK FHM DAYTONA 4TH FL 125 MEMORIAL MEDICAL PARKWAY DAYTONA BEACH, FL 32117

CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS

FA-101U Fire Alarm Control Panel

MATERIALS AND PROCUREMENT DEPARTMENT 1900 YONGE STREET PAGE 1 OF 1 TORONTO, ONTARIO M4S 1Z2

Installation Instructions Type XPMC Air Heater for Hazardous Locations

TrueAlert Addressable Notification Appliances

Installation Instructions

Fire Safety. Installation Instructions Model MMB-2 Main Control Board OPERATION. INSTALLATION Always remove power before installation.

Model 400 Series Lights Installation Instructions

Potter Wall Mount Select-A-Strobe

INSTALLATION INSTRUCTIONS

Guidelines: Proper Installation of Outdoor SpectrAlert Advance Audible Visible Devices. White Paper February 2014

L-Series, Emergency Communication Devices

FMP-DDS & FMP-DTS. Discriminating Dispenser Sump & Turbine Sump BriteSensor. Installation Instructions

Building Name: Our Lady of Sorrows Date: July 10, 2013

1 x4 Dimmable LED RetroFits

Fire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

INSTALLATION INSTRUCTIONS: VERTICAL WALL BED HARDWARE KIT WITH FRAME

MODEL EH ELECTRIC BOILER OPERATION AND INSTALLATION INSTRUCTIONS

Selectable Output Chimes and Chime/Strobes

Speakers and Speaker Strobes

SOUTHVIEW MEDICAL CENTER

harborbreezeoutlet.com

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Communication Products

Arlington Public Schools Purchasing Office

Intelligent Detection Devices

Vibratone Horns. Models 350 and 450

SAFEPATH SAFEPATH. Emergency communications system

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

SELECT-A-HORN/STROBE SERIES

Installation Instructions

Manufacturer of HVAC Equipment Since ,000 sq. ft. on 16 acres. Colton, California USA

INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS FOR Q-SIREN MODELS Q2B-012P, Q2B-012NN, AND Q-MT

SAFEPATH SP40/2 D10 D35 AMP P/N P/N Installation, Testing, TONE SW Operation, and W4 Maintenance D54 SHORT

TotalPac 3 Wet pipe system c/w retard chamber

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

Transcription:

MOUNTING DETAILS Mounting Matrix / Details (a) universal mounting plate ENGINEER AND ARCHITECT SPECIFICATIONS (e) 4 square, deep, flush (bo) 2-1/8 Deep AS Mounting (item included with AS series devices) (b) single-gang, flush (bo) Used with Series MH115, B6, B10, AH, AS, SETSF, SET-ULC, HS, MBDC, MTH, NH, NS, ST (f) double-gang, flush (bo) Used with Series AH, AS, MH, NH, NS, ST (d) 4 square, flush (bo) Used with Series AH, AS, HS, MT, NH, NS, ST (g) Double-gang, surface (bo) D W L. W. 4-¾ 4-¾ 1-1½ Deep Used with Series MH115, B6, B10, AH, AS, HS, MBDC, MTH, NH, NS, ST D. GANG # 1-¾ 2 L L Used with Series AH, AS, NH, NS, ST CATALOG SHEET 2585

(i) WPBBS (order code: RED 500-636137) Plastic backbox for surface mounting series AS weatherproof outdoor products. 1-11/16 (m) MT-SUR-BO backbox (Order Codes: Red 500-693168, White 500-636118) KNOCKOUTS FOR ½ CON- DUIT (TOP, BOTTOM) 2 19/32 5 21/32 TOP 2-5/8 5-21/32 5-1/4 SQ. SQ. TOP 5 3/16 2-5/8 Used with Series SET, HS, MTH, MTWP. For surface mounting MT products. (j) bbs backbox (order codes: Red 500-636110) Standard steel backbox with knockouts for interior surface mounting, concealed conduit mounting or semi-flush applications. (n) dbbs backbox (Order code: Red 500-636111) Standard steel backbox provided with knockouts for interior surface mounting, concealed conduit mounting or semi-flush applications. 5 1-1/2 4 2-3/16 #8-32 TAP (2) HOLES 4 #8-32 TAP (2) HOLES 4 PROVIDED WITH KNOCKOUTS FOR ½ & ¾ CONDUIT Used with Series MH115, B6, B10, AH, AS, MBDC, MTH- 15-115, NH, NS, ST PROVIDED WITH KNOCK- OUTS FOR ½ & ¾ CONDUIT Used with Series MH115, B6, B10, AH, AS, SETSF, HS, MBDC, MTH, NH, NS, ST (k) wbbs weather resistant backbox (order codes: Red 500-636129, White 500-636131) Sturdy die cast housing, threaded conduit hole and knockout for outdoor applications. (p) sbbs backbox (order codes: Red 500-636119, White 500-636120) For surface mounting speakers, chimes, and electronic applications. 5-9/16 3-9/16 TAPPED FOR ½ CONDUIT ¼ DIA. (2) HOLES 4-1/8 3/8 4-1/8 2 0-1/4 5-1/2 2-1/16 ½ KNOCKOUT Used with Series MH115, B6, B10, SETSF, MBDC, MTH-15-115 ¾ KNOCKOUTS (EACH SIDE) ½ KNOCKOUTS (EACH SIDE) Used with Series B6, B10, CH, SEF, SET, SETFL, HS, MBDC, MTH, NH, NS, ST

(Q) 4 square deep w/ extension ring, flush (bo) (T) wpsbbs (ORDER CODES: RED 500-636139, WHITE 500-636140) 1-11/16 5 21/32 TOP 2-1/8 DEEP ET. RING DEPTH 1-1/2 2-1/8 AWG. #18 8 8 AWG. #16 8 8 AWG. #14 8 8 AWG. #12 4 8 Used with Series CH, SEF, SET, SETFL 1-1/2 DEEP 2 19/32 5 3/16 Used with Series ST-WP (R) sfps semi-flush plate (ORDER CODES: RED 500-636124, WHITE 500-636125) Stamped aluminum surface wall plate which mounts behind the basic unit and serves to cover recessed backboxes in semi-flush mounting applications. (U) Square backbox w/ extension ring, flush (bo) 6 5/16 2-7/8 #8-32 TAP (2) HOLES 6 Used with Series MT, SET, SE, NH, NS, ST (s) aps adapter plate (ORDER CODE: RED 500-630109) Stamped aluminum adapter plate designed for applications where semiflush installations cannot be used. The plate can be mounted to standard octagon or round backboxes single or double gang boxes or plaster rings. The backbox and basic unit are then fastened to the plate. This type mounting is referred to as a concealed conduit installation. (w) 4 11 / 16 square, deep surface (bo) 6 5/16 #8-32 TAP (4) HOLES 6 10 10 10 10 Used with Series MBDC

(x) shbbs square, surface backbox (order codes: Red 500-636126, White 500-636127) (BB) spssb (order codes: RED 500-636114, WHITE 500-636115) 11/16 1-9/16 1/2 5 5 Used with Series AS, AH, NS, Z (y) sers SQUARE SEMI-FLUSH ETENSION RING (Order Codes: Red 500-636122, White 500-636123) Used with Series SE-MC/HMC (wall mount speaker/ strobe) 1-9/16" 5" " (CC) SB-W 8 ceiling support bridge (order code: White 500-634882) 23.750 TYP 10.000 7.956 " 5" 10.000 7.956 1.000 TYP 8.500 14.463 Used with Series CH, SEF, SET (z) sbl2s backbox (order codes: RED 500-636121) 1-11/16 6-7/64 11-16 8.500 Used with Series S 8 Ceiling Speakers 10-15/16 (DD) SE-1 8 ceiling Speaker Backbox (order code: WHITE: 500-634881) (AA) spsb (order codes: Red 500-636112, White 500-363113) 12-5/16 9-3/4 4-1/16 11-1/4 Used with Series SE Speakers Used with 8 Ceiling Speakers

(EE) spext Extension Ring (ORDER CODE: RED 500-636116, WHITE 500-636117) (GG) WFPs Plate (ORDER CODES: RED 500-636135, WHITE 500-636136) 3 11/32 3 1-11/16 Used with MTH-WP, ST-WP (hh) WFPAs Plate (Order Codes: Red 500-363133, White 500-656134) 57/8 5/ 8 Used with Series SE-MC-C (ceiling mount strobe) 57/8 (FF) ZBB (ORDER CODES: RED 500-636193, WHITE 500-636194) Used with AS-WP Used with Series Z

MOUNTING MATRI Series SET-C (A) Universal Mounting Plate (included with AS series devices) (B) 1-GANG x 2 Deep - Flush (BO) (D) 4 x 4 x 1. Deep - Flush (BO) (E) 4 x 4 x 2.125 Deep - Flush (BO) (F) 2-Gang x 3. Deep - Flush (BO) (G) 2-Gang x 1.7 Deep - Surface (BO) (I) WPBBS-R Weatherproof Backbox for AS-WP 2 (J) BBS Surface (SP) Note 9 (K) WBBS Weatherproof (SP) 3 (M) MT-SUR-BO Surface & Weatherproof (SP) 4 (N) DBBS Surface (SP) (P) SBBS Surface (SP) (Q) 4 x 4 x 2.12 Box w/ 1. Extension Ring- Flush (BO) (R) SPT Semi-Flush Plate (SP) (S) APS Adapter Plate (SP) (T) WPSBBS-R Weatherproof Backbox for ST-WP 1 (U) Square Backbox w/ Extension Ring, Flush (BO) (W) 4.687 x 4.678 x 2.12 Deep Surface (BO) () SHBBS (SP) Shallow Surface (Y) SERSSemi-Flush Extension Ring (Retrofit Appl.) (Z) SBLS-2 Surface (SP) (AA) SPSB Backbox for SE Speaker (BB) SPSSB Backbox for SE Speaker Strobe (EE) SPET Extension Ring (FF) ZBB Series ST Series ST-MC-RETRO Series MH115 Series SE Series B10-115 Sereis CH Series SETSF-B Series SETSF Series MBDC Series SET/SET Wall Mount Series SE-C Series MH Series MTH Series NH/NS Series HS Series AS/AH Series AH-WB(3), MT-WP(4), MTH Series Z MOUNTING NOTES Caution: The mounting options figures show the maximum number of field wires (conductors) that can enter the backbox used with each mounting option. If these limits are exceeded, there may be insufficient space in the backbox to accommodate the field wires and stresses from the wires could damage the product. Although the limits shown for each mounting option comply with the National Electrical code (NEC), Siemens recommends use of the largest backbox option and the use of approved field wires whenever possible, to provide additional wiring room for easy installation and minimum stress on the product from wiring. Caution: Check that the installed product will have sufficient clearance and wiring room prior to installing backboxes and conduit, especially if sheathed multiconductor cable or 3/4 conduit fittings are used. 1. Mounting hardware for each mounting option is supplied. 2. Conduit entrances to the backbox should be selected to provide sufficient wiring clearance for the installed product. When extension rings are required, conduit should enter through the backbox, not the extension ring. Use Steel City #53151 (1-1/2 deep) or #53171 (2-1/8 deep) extension rings (as noted in the mounting options) or equal with the same cut-out area. 3. When terminating field wires, do not use more lead length than required. Excess lead length could result in insufficient wiring space for the appliance. 4. Use care and proper techniques to position the field wires in the backbox so that they use minimum space and produce minimum stress on the product. This is especially important for stiff, heavy gauge wires and wires with thick insulation or sheathing. 5. Do not pass additional wires (used for other than the appliance) through the backbox unless the backbox is of a sufficient size to permit additional wiring as described in NEC 314.16 (B). Such additional wires could result in insufficient wiring space for the appliance. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Siemens Inc. standard terms and conditions.

BACKBO MOUNTING HEIGHTS for SIEMENS WALL MOUNTED HORIZONTAL STROBE APPLIANCES NFPA-72 (2007) 7.5.4.1* Wall-mounted appliances shall be mounted such that the entire lens is not less than 2030 mm (80 in.) and not greater than 2440 mm (96 inc.) above the finished floor or at the mounting heigh specified using the performance-based alternative 7.5.4.5 7.5.4.2 Where low ceiling heights do not permit mounting at ta minimum of 2030 mm (80 in.), visible appliances shall be mounted within 150 mm (6 in.) of the ceiling. The room size covered by a strobe of a given value shall be reduced by twice the difference between the minimum mounting height of 2030 mm (80 inc.) and the actual, lower mounting height. Backbox Mounting Options* Series AS/AH Audible Strobe Series ST-MC- RETRO Flush and Surface Retrofit Plate Series NS Horn Strobe Series Z and ST Strobe Series MTH Multitone 80 IN 6 IN 80 IN 6 IN 80 IN 6 IN 80 IN 6 IN 80 IN 6 IN (B) 1-Gang x 2 Deep - Flush (BO) 77 ½ 8 ½ 78 3 / 8 7 5 / 8 79 1 / 8 6 7 / 8 (D) 4 x 4 x 1. Deep - Flush (BO) 77 9 83 15 / 16 77 7 / 8 8 1 / 8 78 5 / 8 7 3 / 8 79 15 / 16 6 1 / 16 (E) 4 x 4 x 2.12 Deep - Flush (BO) 77 9 83 15 / 16 77 7 / 8 8 1 / 8 78 5 / 8 7 3 / 8 79 15 / 16 6 1 / 16 (F) 2-Gang x 3. Deep - Flush (BO) 77 ½ 8 ½ 78 3 / 8 7 5 / 8 79 1 / 8 6 7 / 8 80 9 / 16 5 7 / 16 (G) 2-Gang x 1.7 Deep - Surface (BO) 77 ½ 8 ½ 78 3 / 8 7 5 / 8 79 1 / 8 6 7 / 8 80 9 / 16 5 7 / 16 (M) MT-SUR-BO Surface & Weatherproof (SP) 79 3 / 8 6 5 / 8 (P) SBBS Surface (SP) 79 1 / 4 6 3 / 4 (Q) 4 x 4 x 2.12 Box w/ 1. Extension Ring - Flush (BO) (U) Square Backbox w/ Extension Ring, Flush (BO) 69 ½ 8 ½ 83 7 / 16 77 3 / 8 7 5 / 8 78 1 / 8 6 7 / 8 79 7 / 16 5 9 / 16 () SHBBS (SP) Shallow Surface 76 ½ 9 ½ 77 3 / 8 8 5 / 8 78 1 / 8 7 7 / 8 (Y) 4 x 4 x 1. Box w/ 1. Extension Ring Plate (BO) (Z) SBL2S Surface (SP) 78 (FF) ZBB 78 1 / 8 7 7 / 8 Backbox Mounting Options* * Measured from Bottom of Backbox Series CH Chime Strobe NOTES: (BO) = By Others (SP) = Siemens Product Series SET-V Speaker Strobe Series SEF-C Speaker Strobe Series SET-C Speaker Strobe 80 IN 6 IN 80 IN 6 IN 80 IN 6 IN 80 IN 6 IN (P) SBB Surface (SP) 77 ¾ 8 ¼ 79 3 / 16 6 13 / 16 77 ¾ 8 ¼ 77 ¾ 8 ¼ (Q) 4 x 4 x 2.12 Box w/ 1. Extension Ring - Flush (BO) (U) Square Backbox w/ Extension Ring - Flush (BO) () SHBB (SP) Shallow Surface (Y) 4 x 4 x 1. Box w/ 1. Extension Ring Plate - Flush (BO) 77 ½ 7 ½ 80 6 78 ½ 7 ½ 78 ½ 7 ½ 78 7 79 ½ 5 ½ 78 7 78 7 78 ½ 7 ½ 80 6

WARNING: PLEASE READ THESE SPECIFICATIONS AND INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Siemens Building Technologies Fire Safety Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600 FA: (973) 593-6670 Website: www.sbt.siemens.com/fi 6/07 5M SFS-IG Printed in U.S.A. Fire Safety 2 Kenview Boulevard Brampton, Ontario Canada L6T 5E4 Tel: (905) 799-9937 FA: (905) 799-9858 June 2007 New Issue