Operation & Maintenance Manual

Similar documents
SECTION 1-1 SAFETY PRECAUTIONS

Diva Acoustical Shell

Telecab17 Residential Elevator OWNER S MANUAL

Smoke Vent with Manual Winch. Installation, Operation and Maintenance

Model 600 Operation & Maintenance Manual

Easy Rooter. Operating Instructions

TCUT10UL 2.5 HP 10 Tile Saw Assembly & Operating Instructions

OPERATING & SERVICE INSTRUCTION MANUAL FOR

Contents. Getting Started. Operation. Maintenance and Care. Problem Solving Guide. Warranty 13

OPERATOR S MANUAL HWH HYDRAULIC SPACEMAKER ROOM EXTENSION SYSTEM FEATURING: DUAL CYLINDER ROOM EXTENSION (WITH RACK SENSING VALVE) HCORPORATION

Machine Guarding. 1 Copyright 2014, Rev by PEC Safety Management, Inc. PPT-SM-MG 2014, Rev

R OL L ING F IR E DOOR T E S T ING P R OGR AM

100Years of FireSafety Curtains

SECTION 1-1 SAFETY PRECAUTIONS DOUBLE ARM MIXER CHAPTER 1: SAFETY

R10S, R10D, R10P & R10SAND. Owner s Manual

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

User s Manual and Operating Instructions

MACHINE GUARDING: PROTECTING YOU FROM HAZARDS

User s Manual and Operating Instructions

Mini-Rooter Operating Instructions

CHAPTER 1 TABLE OF CONTENTS SAFETY SPIRAL FLOW DOUGH FEEDER

WINDOW/WALL-TYPE ROOM AIR CONDITIONER

PISTON DEPOSITOR TABLE OF CONTENTS

BB TM 508/509 ANTI TWO-BLOCK ALARM SYSTEM HYDRAULIC CRANE INSTALLATION. Greer Company Crane Systems. Greer Company

Electrical Safety. Don't allow trees near power lines to be climbed. Keep ladders, kites, equipment and anything else away from overhead power lines.

INSTALLATION and OPERATION BALL WASHER MODEL NO: BW-022

Canister Vacuums S6EVO. Operations and Parts Manual. Models: S6EVO

Telecab Residential Elevator OWNER S MANUAL

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

ATD BELT DRIVE DRUM FAN INSTRUCTIONS

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Operation & Maintenance Manual

HYBRID DRYER. PDH1 - PDH2 Series. Save These Instructions

Cable Drum Machine. Operation Manual 40 SERIES. Cleans 2" to 4" lines up to 75' N O T F O R R O O T S

14 Upright Vacuum with HEPA Filter & Dual Power

3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9

HYBRID DRYER. PDH1 - PDH2 Series WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

MODEL PR16 POWER ROTARY

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

SuperKlean Washdown Products

TB-390 Conveyor Stacker

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual

THE UNIVERSITY OF THE WEST INDIES Mona Campus Human Resource Management Division (HRMD) SECTION I GENERAL SAFETY

Wand Cleaning Adjusting the Suction Power for Tool Cleaning Cleaning Tools... 11

INSTALLATIONN GUIDE & OPERATION MANUAL

OPERATOR S MANUAL & PARTS LIST

Please read this manual before using the machine. Please keep this manual within easy reach for quick reference.

(The chances are you re never going to read me) Owner s Manual HEAVY DUTY SHD-1T.

Landis Fume Buster 3, 4 & 5 Foot

(The chances are you re never going to read me) Owner s Manual. Model S10E.

Electrical Preventive Maintenance (EPM) Program

Easy Rooter Operating Instructions

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

Bliss Box Former Troubleshooting. 6.1 Troubleshooting Chart. Troubleshooting INTRODUCTION SAFETY PROCEDURES

Component. Maintenance. Manual Z SERIES. Evaporator Assembly

R20SC, R20E & R20ENT. Owner s Manual

MODEL B2 INSTALLATION MANUAL

your floor machine. As a shipper, we are unable to act upon any claim for concealed damage. You must originate any claim within 5 days of delivery.

SC250X FLOOR GRINDER OPERATIONS MANUAL

Panel Fan Series Operators Manual (Galvanized and Polymer)

SERVICE PARTS/OPERATION for

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

USER'S MANUAL PGE Single Package Rooftop

FiberPRO 2.5 H. Heated Spot Extractor. Operator and Parts Manual E

MANUAL RESET ALARM RELEASE BOX

With Remote Control. English

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

Owner s Manual CPU-1QD CPU-1 CPU-1T CPU-2 CPU-2T HEAVY DUTY UPRIGHT VACUUMS. Save These Instructions

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

Vari-Cyclone Ceiling Fans

STEP BY STEP INSTALLATION INSTRUCTIONS. Wood Blinds. Standard Control

Register at

RELEASE DEVICE CONTROLS

The CENTURY. High Performance Oscillating Fan OWNER S GUIDE FOR MODELS 9002X & 9702X

WAV-30 WIDE AREA VACUUM

INTELLI-VAC 14 INTELLI-VAC 18

OPERATOR S MANUAL HWH HYDRAULIC SPACEMAKER ROOM EXTENSION SYSTEMS

User s Information Manual

THE READY RACK 2 GEAR PPE DRYING CABINET. Operator s Manual & Installation Guide. Installation/Operation/Maintenance/Part Number I

MANUAL RESET ALARM RELEASE

Full Size Canister Service Manual Riccar Models 1700 / 1800 Power Nozzles RPB-100 / RPB-220 / RPB-224 / RPB-250

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R

User s Manual and Warranty Information ThyssenKrupp Access

MODEL # EE-8077W. If you have any questions about the operation of your infrared heater, please contact Crane Customer Care.

Installation & Maintenance Instructions

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

SECTION 1-1 SAFETY PRECAUTIONS DOUGH CONVEYOR CHAPTER 1: SAFETY

General Mini-Rooter XP

TECHNICAL INFORMATION B 890 and B 990 Rotary Irons (US Models)

OWNERS MANUAL ST50BT

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

MANUAL RESET ALARM RELEASE

BL Series INSTRUCTIONS

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

5KW ELECTRIC FAN HEATER

Owner s Manual. For the Fuller Brush PORTABLE CANISTER Vacuum. Model FB-GIM

Transcription:

Operation & Maintenance Manual Brail Fire Curtain m WARNING Improper use of rigging equipment can result in serious injury. Do not operate without proper training and authorization. Not for lifting people.

PAGE 1 Table of Contents Introduction... 1 Operation... 2 Fire Curtain Maintenance... 6 SureGuard Release Maintenance... 8 Note This is a generic manual provided for guidance in the operation and maintenance of a theatrical rigging system. This manual shows the most frequently used features and options, which may differ from your system. Your system may differ from or not contain all of the options shown in this manual. If you own a J. R. Clancy rigging system, contact us for availability of a project specific manual. Introduction Anyone who enters a building with public access has reason to expect that he or she is safe from harm from the building itself or from the equipment and activities within the building. It is the legal responsibility of the owner and his designated manager to ensure that this expectation is met. It is the responsibility of the owner to hire and train competent people. A competent person is defined as one who is capable of identifying existing and predictable hazards in the workplace, and who has authorization to take prompt corrective action to eliminate those hazards. It is the further responsibility of the owner and his designated manager to provide a safe working environment for all employees, including proper equipment, training on the use of equipment, and written procedures for its use and maintenance. It is also important to keep all unauthorized and/or untrained personnel from the working areas of the stage. Before operating any stage equipment, operators must be given the necessary training and must then work only under the direction of qualified supervisors. Operators of the equipment must: Learn the feel, sound, and even the smell of your equipment so that you will immediately sense when something is not correct. Study the capacities and capabilities of each system and its components. Thoroughly learn and practice the proper operating procedures. Before operating any equipment, ask yourself questions about the current condition of equipment and about any existing conditions which may affect proper operation or which could be affected by its

PAGE 2 operation. For example, is anything fouling the equipment or in the path of its intended travel? Any problem noticed during setup or operation of the stage equipment should be corrected IMMEDIATELY. A routine maintenance schedule must be established and followed and appropriate records maintained. Perform an initial inspection, followed by inspections on a regular basis. Routine maintenance prolongs the useful life of equipment and keeps it operating at peak efficiency. This insures the quietest possible operation and the least effort on the part of the operator. In addition to routine maintenance, we strongly recommend that a qualified rigging firm be engaged to perform periodic inspections and to correct any deficiencies discovered. These firms have personnel who are trained to spot present hazards and many "potential" hazards. DISCLAIMER The information in this manual will not cover all possible situations, nor could such inclusive instructions be possibly written by the equipment manufacturer, due to the various processes of mounting theatrical performances. This manual is intended to provide a guide to the safe and efficient operation of the furnished stage equipment and its routine maintenance. No manual can replace your duty for constant vigilance and common sense. We are not responsible for any damage that results from failure to comply with this manual. General Brail Fire Curtain A fire safety curtain system exists to allow an audience sufficient time to safely exit from an auditorium in the event of a fire on the stage. It does this in two ways: It helps contain smoke and heat within the stage, so they can be effectively removed by the stage ventilation systems. It delays damage to the auditorium from a fire on stage or from the reverse. In order to serve its function, the curtain must close quickly and surely. If the curtain is used to close off the stage when it is not being used, or is used as a decorative drop, it MUST be restored to full operating condition each time it is raised. Some building codes require that fire safety curtains be left closed when the theatre is unoccupied as a safety measure. This may also reduce unauthorized access to the stage.

PAGE 3 OPERATION m WARNING Fire curtain will close automatically in an emergency. Curtain path must be kept clear at all times. Improper operation may result in injury. Do not use emergency release to lower curtain in non-emergency situations. The curtain is raised and lowered in a controlled manner by lift lines attached to a single drive line and controlled by a manually operated (hand cranked) brail fire safety curtain winch. m WARNING The crank handle should never be left attached to the winch shaft. Failure to remove the handle may lead to injury or prevent the curtain from closing in an emergency The deployment of the fire safety curtain is automatic in response to a fire, test, or intentionally deployed in an emergency. After any operation (intentional or not), the fire safety curtain system must be reset. An emergency release line containing fusible links and manual release devices is installed around the proscenium opening. The release line is weighted at one end and applies upward tension to the brake or clutch release handle located on the brail winch. Releasing tension in the line frees the brake and permits the fire safety curtain to lower by gravity. The speed of descent is controlled by a hydraulic governor located in the winch housing. The fire safety curtain can be deployed by one or more of the following methods (Check the drawings of your system for specific details): Temperature sensitive fuse links in the release line. Operating a mechanical latch (Pull Ring, Lever, etc.) in the release line. Activating an electro-mechanical device by means of a switch, smoke detector, temperature rate-of-rise detector, sprinkler flow detector, or signal from the fire alarm system. Depressing and holding the brake handle When the curtain is deployed, the drive line may go slack when the curtain reaches the floor. As you raise the curtain using the hand crank the haul line should be hand guided (wearing gloves) until the slack is removed so that the cable winds on the drum in a smooth layer. Manual Brail Winch The curtain may be raised and lowered by turning the crank handle supplied with the winch. The crank handle is stored on top of the winch case and is held in place by a magnet. The brake must be released in order to turn the crank, but should not be released until the crank is firmly gripped by the operator. The brake may be freed by having a second person lift the round weight arbor (so that the release line goes slack) or by pushing down on the brake handle.

PAGE 4 RELEASE MECHANISM To Bottom of Arbor The most common manual emergency release mechanism for this type of system is a small lever located at either side of the proscenium opening. Pulling on the leaver frees the release line, disengaging the clutch at the winch, and allowing the curtain to deploy. Some lever type releases may be located within a protective cover. Consult your system specific drawings for complete information. Free End Ball Release line Hand Line Free End Ball The most basic of releases, this system requires that the curtain be heavier than the counterweight at all times. The free end of the release line is terminated by a steel ball. The release line is looped over itself in such a way that it chinches down between the steel ball and the handline. The tension placed into the release line by the upward pull of the curtain against the arbor holds the loop in place and prevents the curtain from deploying. When the release line goes slack, the loop falls off of the handline, allowing the curtain to deploy. To Floor Pulley This type of system requires some practice and angle at which the release line is attached to the handline is critical. Too little of an angle, and the curtain will not deploy. Too much of angle and the release line won t hold. Additional weight may be added to the release line either before of after the floor block to aid in the quick freeing of the line. If you are having difficulty with setting your release, contact a professional stage rigging company.

PAGE 5 Arbor Release (Lever Type) The ring and line on the left are attached to the bottom of the arbor, restraining it and keeping the curtain open. The lever is held in place by the release line (at right). Once the release line is freed, the lever pivots, releasing the arbor and allowing the curtain to close. This device requires that the curtain be heavier than the counterweight at all times. The Sure-Guard II contains an integral battery and charger to provide emergency power in case of interruption to normal power. A test switch on the cover allows the fire safety curtain and control to be tested and LED s indicate the presence of 120 VAC power and the status of the battery power. After operation, the Sure-Guard II system and release line must be reset. Reeve the release line around either of the two stacked sheaves on the unit, through the small pulley, and then around the other stacked sheave. The loop on the small pulley is then placed over the trip arm and the arm is placed in contact with the electromagnet. The Sure-Guard II must be powered before the arm and release line will stay engaged. SURE-GUARD II Release System The Sure-Guard II allows smoke detectors, rate of rise detectors or other electrical signals to deploy the fire safety curtain in an emergency. In response to these signals, the Sure-Guard II s electro-mechanical mechanism releases tension in the release line, allowing the fire safety curtain to deploy. The release mechanism may be located at any point along the release line and does not interfere with other deployment mechanisms. To ensure proper operation, the tension in the release line must be set between 5 & 40 pounds (3 & 18 Kg). See the fire safety curtain system drawings for additional details on installing the release line and rigging for your specific system.

PAGE 6 Fire Curtain Inspection & Testing INSPECTION All equipment requires periodic maintenance and inspection to insure long life and trouble free operation. Inspect your system on a regular, scheduled basis and keep records. These inspections will provide information on length of service and any changes in performance which might indicate wearing parts. Inspections should include, at minimum, the following items: All blocks, cables, fittings, etc. (See Rigging Inspection Instruction Sheet) The condition of the curtain, including seams, frayed edges, tears or holes, curtain guides, and clamps. The condition of fusible links including bends or fractured solder joints. The condition of all curtain release devices and instruction signs or labels Any obstructions that would block proper access to, or operation of, the curtain The condition of a brail winch: Is the brail winch handle present and properly stored for use? Is the brake handle clear and the brake properly adjusted? requirements for the periodic replacement of certain items, such as fusible links. Check with your local code authority for information. TESTING Immediately prior to testing, it is necessary to perform a visual inspection as described above. If the curtain system permits operation by power or hand without tripping the automatic descent, perform a full lower and raise cycle. Look and listen for any unusual performance or problems. Deploy the curtain using each automatic release device that is installed in the system, except for the fusible links. You can also deploy the curtain by lifting round weight arbor at the end of the release line, or by disconnecting the release line itself. A second person should time the curtain as it closes. Most codes require that the curtain close within 30 seconds and that the last 5 to 10 feet of travel must take at least 5 seconds. The curtain must not bounce back into the air after it hits the floor. Travel must be smooth and free of pinch points in the guide system. If practical and appropriate, test the curtain at least once with the smoke hatches open or with the heat or air conditioning blowers on to determine if air loads prevent the lowering of the curtain. If problems exist, make immediate adjustments or repairs, or contact a qualified professional stage rigging company for assistance. Reset all curtain functions when finished. The fire safety curtain emergency deployment system should be tested a minimum of four times a year. Some local codes may have specific

PAGE 7 MAINTENANCE Since the fire safety curtain may not be routinely activated, but must always be functional in an emergency, routine scheduled inspections and maintenance are vital. Maintenance for fire safety curtain rigging is much the same as other stage rigging systems, but with the following additions: DO NOT ALLOW the travel path of the cables, guided clew, or curtain to be blocked. DO NOT ALLOW access to the release line or other controls to be obstructed. Operate the curtain on a regular schedule to determine if the curtain or its rigging has fouled. Vacuum the curtain on a regular basis. Dust burns and can help defeat the purpose of the fire safety curtain if it is allowed to accumulate. It will also help keep the theatre clean and prevent the curtain from getting heavier, thus altering the balance of the system. The proprietary coatings are easily removed, so any cleaning should be done only when necessary and then with great care.

PAGE 8 Sure-Guard Maintenance GENERAL DESCRIPTION The Sure-Guard II safety curtain release system consists of a trip arm with pulleys, a metal loop, an electromagnet, and a control section with a leadacid battery, battery charger, terminals and fuse blocks. The system can be installed at the end of the fireline or at any point in the line and can be used to release various types of safety curtains. Terminals in the controller allow connection to normally open and normally closed contacts used in push buttons, heat and smoke detectors, rate of rise heat detectors, fire alarms, and other similar devices. These devices are not supplied with the basic system. A test switch on the cover allows the fire curtain and control to be tested and LED=s indicate the presence of 120 VAC power and battery power. INSPECTION All equipment requires periodic maintenance and inspection to insure long life and trouble free operation. Inspect on a scheduled basis and keep records. These will provide information on length of service and upon any changes in performance which might indicate wearing parts. The whole fire curtain system, including the Sure-Guard II release, should be tested occasionally by using the test button or other installed release controls. This test checks the operation of the electronics and all of the associated rigging. The battery should be tested approximately once each year by removing input power for 20 minutes and verifying that the curtain stays up. MAINTENANCE Any damaged equipment or obstructions found during inspections or in use should be attended to immediately. Before performing any maintenance on the Fireline Release Control, it should be removed from use and disconnected or locked out. Keep all objects away from the curtain and fireline that would prevent proper operation. TROUBLE SHOOTING: See the following trouble shooting check list.

PAGE 9 TROUBLE SHOOTING CHECK LIST PROBLEM Trip arm will not stay engaged No power to control box POSSIBLE CAUSE Excessive pull in fireline No power to electromagnet to engage arm Switch off REMEDY The maximum permissible pull on the hook is 50 pounds (100 pounds (45 Kg) in the fireline). Note that the maximum allowable force in a fuse link is 40 pounds (18 Kg). See balance of ATrouble Shooting Check List.@ Turn on switch or circuit breaker at power source. PROBLEM POSSIBLE CAUSE Battery worn out or defective REMEDY Unhook the battery and check output voltage. It should be at least 12 VDC. Note that a new battery will take about 24 hours to fully charge after installation. With the electromagnet installed, check the voltage between terminals >D= & >E= on the control board. If the voltage is 0 VDC, replace the battery. Blown fuse Normally closed devices missing, defective, or improperly wired Replace fuse. Check for possible short circuit. Install or repair devices. Check wiring. Install a jumper between terminals >A= & >B= if no normally closed devices are installed. Electromagnet not holding Defective Electromagnet If 12 VDC can be measured between terminals 1 & 2 with the electromagnet properly installed, it is defective and must be replaced. Battery not charging Normally open devices defective or improperly wired Defective control board Battery not connected Install or repair devices. Check wiring. Unplug the battery and check to see that voltage is present at the receptacle. If not, replace control board. Check the wire connections on the battery to be sure it is fully engaged