Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Similar documents
Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

PROTECT SRB 200EXi-1A

Datasheet - MZM 100 ST-SD2PREM-A

Datasheet - MZM 100 ST2-1P2PWREM-A

Datasheet - MZM 100 B ST2-SD2PREM-A

Datasheet - AZM 161SK-12/12RK-024

Datasheet - AZM 161SK-12/12RK-024

ISIS SAFETY SYSTEM Installation guide

Datasheet - TVS /B-M20

Operating Manual MS220KA and MSR220KA

Datasheet - AZM ZRK 24 VAC/DC

Original instructions Sense7-series Non-contact coded safety switch

SensaGuard TM Integrated Latch Installation Instructions

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Operating Guide Safe Torque Off

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Original operating instructions Safety switch with guard locking AC901S AC902S

Operating Manual MS220DA

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170

BES M30EP-PFC12F-S04G-D12 BES Q40ZU-PFC15B-S04G-D12 BES Q40ZU-PFC20F-S04G-D12 Inductive Safety Sensors User's Manual

Safety. Detection. Control. SAFETY INTERFACES. Safety Interfaces and Relays. Product catalogue. Issue 1

Operating Guide Safe Torque Off

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

SLC 220 E/R RFBS

SAFETY RELAY APPLICATION

Manual Power relay SR853

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

/ / 2018

Magnetically Coded Non-contact Switch (MC2)

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Operating Manual MS220VA and MSR220VA

Sensing light curtain as per DIN 18650/EN 16005

Rules for Classification and Construction Additional Rules and Guidelines

Sensing light curtain as per DIN 18650/EN 16005

Functional Safety of Machinery Presented by Greg Richards Manufacturing in America 02/22-23/2017

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

SAFETY INTERFACES SAFETY INTERFACES AND RELAYS

1.7. Insulation fault evaluators EDS460/490 EDS461/491

RE-PR3-E-27 3-Phase Panel Mount 27kW

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Scha tschra Hei u g E c sure heater R sista ces chauffa tes Scha e astverwar i ge. Risca dat re a tic de sa Resiste cia ca efact ra 3105 XXX

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Optoelectronic level switches, models OLS-C. Optoelektronische Füllstandsschalter, Typen OLS-C. Commutateurs de niveau opto-électroniques, type OLS-C

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Latch key safety limit switches Technical data

Installation instructions

Operating Manual VMD420

Safety Function: Single-beam Area Access Control (AAC)

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

Power Supply Display Module PSDM. Installation and Operation Manual

Technical Data. Dimensions

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Instructions for the fan motor control system, SILVER C

MANUAL Overflow sensor NVF-104/34-PF

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

OPERATING MANUAL RAY-NC 1000 SERIES

TTV 4500 / TTV 4500 HP / TTV 7000

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Instructions for the fan motor control system with integrated wiring terminals SILVER C

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05

Instruction Manual. Electronic gas and smoke detector GRM

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Electronic Temperature Controller 70304,

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Project planning (original) EN. Functional safety. Inverter i550-cabinet kw

Overload Relay EMT6 Overload monitoring system for machines operating in the EEx e area

Flameproof Manual Call Points

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

Millo / Millo pro. Nr x000 / 1805-x000

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Specification Document. Single-circuit Embedded Water Leakage Detector AD-AS-1BM (RoHS-directive-compatible)

Translation of the assembly instructions with operating instructions and technical appendix

One giant leap for safety: AZM400.

Transcription:

1 About this document... pages 1 to 8 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety-monitoring module. The operating instructions must be available in a legible condition and a complete version in the vicinity of the device. 1.2 Target group: authorised qualified personnel All operations described in this operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only. FR NL P Vous trouverez la version actuelle du mode d emploi dans votre langue nationale officielle sur l Internet, www.schmersal.net. U vindt de huidige versie van de gebruikshandleiding in uw officiële landstaal op het Internet, www.schmersal.net. EU 公用語で書かれた最新の取扱説明書は インターネッ (www.schmersal.net) からダウンロードできます ES IT Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www.schmersal.net. Il manuale d istruzioni aggiornato nella vostra lingua (lingua ufficiale UE) è scaricabile in Internet all indirizzo www.schmersal.net. Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation. The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components. 1.3 Explanation of the symbols used Information, hint, note: This symbol is used for identifying useful additional information. 21.01.2010 / Index: 441/09 / Teile-Nr. 1176229- Content 1 About this document 1.1 Function..............................................1 1.2 Target group: authorised qualified personnel..................1 1.3 Explanation of the symbols used...........................1 1.4 Appropriate use........................................1 1.5 General safety instructions...............................1 1.6 Warning about misuse...................................1 1.7 Exclusion of liability.....................................2 2 Product description 2.1 Ordering code.........................................2 2.2 Special versions........................................2 2.3 Destination and use.....................................2 2.4 Technical data.........................................2 2.5 Safety classification.....................................3 3 Mounting 3.1 General mounting instructions.............................3 3.2 Dimensions...........................................3 4 Electrical connection 4.1 General information for electrical connection..................3 5 Operating principle and settings 5.1 LED functions..........................................3 5.2 Description of the terminals...............................3 6 Set-up and maintenance 6.1 Functional testing.......................................4 6.2 Maintenance..........................................4 7 Disassembly and disposal 7.1 Disassembly...........................................4 7.2 Disposal..............................................4 8 Appendix 8.1 Wiring examples.......................................4 8.2 Start configuration......................................5 8.3 Sensor configuration....................................5 8.4 Actuator configuration...................................6 8.5 Flowcharts............................................7 8.6 EC Declaration of conformity..............................8 Caution: Failure to comply with this warning notice could lead to failures or malfunctions. Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine. 1.4 Appropriate use The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the proper functionality of the entire machinery or plant. The safety-monitoring module must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the chapter Product description. 1.5 General safety instructions The user must observe the safety instructions in this operating instructions manual, the country-specific installation standards as well as all prevailing safety regulations and accident prevention rules. Further technical information can be found in the Elan catalogues or in the online catalogue on the Internet: www.schmersal.net. The information contained in this operating instructions manual is provided without liability und is subject to technical modifications. There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed. 1.6 Warning about misuse In case of inadequate or improper use or manipulations of the safety-monitoring module, personal hazards or damage to machinery or plant components cannot be excluded. The relevant requirements of the standard 1088 must be observed. 1

1.7 Exclusion of liability We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual. The manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories. For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden; the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device. 2 Product description 2.1 Ordering code This operating instructions manual applies to the following types: SRB 202➀ No. Option Description ➀ CS Reset not monitored, optionally automatic reset* CS/T Reset monitored* CA Reset not monitored, optionally automatic reset*, switch-off level 2 with antivalent inputs CA/T Reset monitored*, switch-off level 2 with antivalent inputs, cross-wire short detection* CA/Q Reset not monitored, optionally automatic reset*, switch-off level 2 with antivalent inputs CA/QT Reset monitored*, switch-off level 2 with antivalent inputs, cross-wire short detection* * with reference to switch-off level 1 Only if the information described in this operating instructions manual are realised correctly, the safety function and therefore the compliance with the Machinery Directive is maintained. 2.2 Special versions For special versions, which are not listed in the order code below 2.1, these specifications apply accordingly, provided that they correspond to the standard version. 2.3 Destination and use The safety-monitoring modules for integration in safety circuits are designed for fitting in control cabinets. They are used for the safe evaluation of the signals of positive break position switches or magnetic safety sensors for safety functions on sliding, hinged and removable safety guards as well as emergency stop control devices and AOPD s. The safety function is defined as the opening of enabling circuits 13-24 when the inputs S31- and/or S41-S42 (S43-S44) are opened and as the opening of enabling circuits 13-14 and 13-24 when the inputs and/or S22 are opened.the safety-relevant current paths with the output contacts 13-14 and 13-24 meet the following requirements under observation of a B 10d value assessment (also refer to Requirements to DIN ISO 13849-1 ): Control category 4 PL e to DIN ISO 13849-1 corresponds to SIL 3 to DIN 61508-2 corresponds to SILCL 3 to DIN 62061 (corresponds to control category 4 to DIN 954-1) To determine the Performance Level (PL) of the entire safety function (e.g. sensor, logic, actuator) to DIN ISO 13849-1, an analysis of all relevant components is required. 2.4 Technical data General data Standards: IEC/ 60204-1, 60947-5-1, ISO 13849-1; IEC/ 61508 Climate resistance: 60068-2-78 Fixing: Snaps onto standard DIN rails to DIN 60715 Terminal designations: 60947-1 Material of the enclosure: glass-fibre reinforced thermoplastic, ventilated Material of the contacts: AgSnO, AgNi, self-cleaning, positive drive Weight: 235 g Start conditions Automatic or start button (Refer to 2.1 Ordering code) Feedback circuit (Y/N): Yes Pull-in delay with reset button: Switch-off level 1: typ. 40 ms Switch-off level 2: typ. 0.5 sec. Drop-out delay in case typ. 50 ms of emergency stop: Mechanical data Connection type: Screw connection Cable section: min. 2 mm 2 / max. 2 mm 2 Connecting cable: rigid or flexible Tightening torque 0.6 Nm for the terminals: With removable terminals (Y/N): Yes Mechanical life: 10 million operations Electrical life: Derating curve available on request Resistance to shock: 10 g / 11 ms Resistance to vibrations 10... 55 Hz, amplitude 0.35 mm to 60068-2-6: Ambient conditions Ambient temperature: 25 C +45 C Storage and transport 40 C +85 C temperature: Protection class: Enclosure: IP 40 Terminals: IP 20 Wiring compartment: IP 54 Air clearances and creepage 4 kv/2 (basic insulation) distances to IEC/ 60664-1: EMC rating: to EMC Directive Electrical data Contact resistance max. 100 mω in new state: Power consumption: max. 4.4 W Rated operating voltage U e : 15%/+20%, residual ripple max. 10% Max. fuse rating of the operating voltage: electronic fuse, tripping current > 1 A; reset after approx. 1 sec. Monitored inputs Cross-wire detection (Y/N): Refer to 2.1 Ordering code Wire breakage detection (Y/N): Yes Earth leakage detection (Y/N): Yes Number of NO contacts: CS, CS/T: 0 pc. CA, CA/T, CA/Q, CA/QT: 1 pc. Number of NC contacts: CS, CS/T: 4 pc CA, CA/T, CA/Q, CA/QT: 3 pc Current and voltage limitation S31-, S43-S44: of the control contacts: 26 VDC / 100 ma26 VDC / 100 ma Cable lengths: 1-channel without cross-wire short detection: 1,500 m = 1.5 mm² 2,500 m = 2.5 mm² 2-channel with or without cross-wire short detection Conduction resistance: max. 40 Ω 2

Outputs Number of safety contacts: 2 Number of auxiliary contacts: 2 Switching capacity of the safety contacts: 13-14; 13-24: max. 250 V, 6 A ohmic (inductive in case of appropriate protective wiring) max. residual current 6 A 31-32, 31-42: / 2 A 6.3 A slow blow Switching capacity of the auxiliary contacts: Fuse rating of the safety contacts Recommended fuse 2 A slow blow for the auxiliary contacts Utilisation category to AC-15: DC-13: 60947-5-1:2007 60947-5-1: Dimensions (H/W/D): 100 mm x 22.5 mm x 121 mm The data specified in this manual is applicable when the component is operated with rated operating voltage U e ±0%. 2.5 Safety classification Standards: ISO 13849-1, IEC 61508, 60947-5-1 PL: Stop 0: up to e Control category: Stop 0: up to 4 DC: Stop 0: 99% (high) CCF: > 65 points SIL: Stop 0: up to 3 Service life: 20 years B 10d value (for one channel): Low voltages range 20%: 20,000,000 40%: 7,500,000 60%: 2,500,000 80%: 1,000,000 Maximum load 100%: 400,000 MTTF d B10d dop x hop n x 3600 s/h op 0,1 x n op t cycle For an average annual demand rate of n op = 126,720 cycles per year, Performance Level PL e can be obtained at maximum load. n op = average number of activations per year d op = average number of operating days per year h op = average number of operating hours per day t cycle = average demand rate of the safety function in s (e.g. 4 per hour = 1 per 15 min. = 900 s) (Specifications can vary depending on the application-specific parameters h op, d op and t cycle as well as the load.) 4 Electrical connection 4.1 General information for electrical connection The electrical connection may only be carried out by authorised personnel in a de-energised condition. Wiring examples: see appendix 5 Operating principle and settings 5.1 LED functions : Status channel A : Status channel B : Status channel C : Status channel D U B : Status operating voltage (LED is on, when the operating voltage on the terminals A1-A2 is ON) U i : Status internal operating voltage (LED is on, when the operating voltage on the terminals A1-A2 is ON and the fuse has not been triggered) 5.2 Description of the terminals Voltages: Inputs: A1 A2 S22 S31- S41-S42 S43-S44 Outputs: 13-14 Start: 13-24 31-32 31-42 X2 + 0 VDC Switch-off level 1, input channel 1 Switch-off level 2, input channel 2 Switch-off level 2, input channel 1 Switch-off level 2, input channel 2 (SRB 202CS, 202CS/T) Switch-off level 2, input channel 2 (SRB 202CA, SRB 202CA/T, SRB 202CA/Q, SRB 202CA/QT) First safety enabling circuit (stop 0), switch-off level 1 Second safety enabling circuit (stop 0), switch-off level 2 Auxiliary NC contact, switch-off level 1 (must not be used in safety circuits) Auxiliary NC contact, switch-off level 2 (must not be used in safety circuits) Feedback circuit, manual start (reset button), automatic start, switch-off level 1 Feedback circuit, manual start (reset button), automatic start, switch-off level 2 3 Mounting 3.1 General mounting instructions Mounting: snaps onto standard DIN rails to 60715. Snap the bottom of the enclosure slightly tilted forwards in the DIN rail and push up until it latches in position. 3.2 Dimensions All measurements in mm. Device dimensions (H/W/D): 100 x 22.5 x 121 mm with plugged-in terminals: 120 22.5 121 mm 24 14 13 31 S22 A1 UB Ui SRB 202 * S42 X2 A2 S31 S41 32 42 Fig. 1 3

Due to the operating principle of the electronic fuse, the customer must check that no hazard is caused by an unexpected restart in circuits without reset button (automatic reset). A1 S22 S41 S42 S31 X2 13 31 L1 6 Set-up and maintenance 6.1 Functional testing The safety function of the safety-monitoring module must be tested. The following conditions must be previously checked and met: 1. Correct fixing 2. Check the integrity of the cable entry and connections 3. Check the safety-monitoring module s enclosure for damage. 4. Check the electrical function of the connected sensors and their influence on the safety-monitoring module and the downstream actuators 6.2 Maintenance A regular visual inspection and functional test, including the following steps, is recommended: 1. Check the correct fixing of the safety-monitoring module 2. Check the cable for damages 3. Check electrical function Damaged or defective components must be replaced. 7 Disassembly and disposal 7.1 Disassembly The safety-monitoring module must be disassembled in a de-energised condition only. 7.2 Disposal The safety-monitoring module must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations. A2 F1 UB Ui a) Fig. 2: SRB 202CS, 202CS/T a) Logic 14 24 32 Dual-channel control, shown for a emergency stop circuit; with two contacts A and B and a guard door monitor with two contacts C and D, where at least one is a positive break contact; with external reset button (related on the switch-off level 1) (see Fig. 3) Relay outputs: Suitable for 2-channel control, for increase in capacity or number of contacts by means of contactors or relays with positiveguided contacts. The control system of the emergency stop circuit detects wire breakage and earth faults (cross-wire shorts in the SRB 202CA/QT and SRB 202CA/Q versions). The control system of the door monitoring circuits detects wire breakage, earth faults and cross-wire shorts. S = Feedback circuit A1 Channel B of SRB 202CA/Q and SRB 202CA/QT: 0 V S22 (see Fig. 4) S22 S43 S44 S31 X2 13 31 L1 42 N KC S 8 Appendix 8.1 Wiring examples Dual-channel control, shown for a emergency stop circuit; with two contacts A and B and a guard door monitor with two contacts C and D, where at least one is a positive break contact; with external reset button (related on the switch-off level 1) (see Fig. 2) Relay outputs: Suitable for 2-channel control, for increase in capacity or number of contacts by means of contactors or relays with positiveguided contacts. The control system recognises wire-breakage and earth faults in the monitoring circuit. S = Feedback circuit A2 F1 UB Ui a) 14 24 32 Fig. 3: SRB 202CA, 202CA/T, SRB 202CA/Q, SRB 202CA/QT a) Logic 24 VCC 0 V 42 N KC S S22 Fig. 4 4

8.2 Start configuration External reset button (Fig. 5) The external reset button is wired to the terminals (without edge detection for switch-off level 1) and X2 (without edge detection for switch-off level 2). The external reset button is integrated in the feedback circuit in series. 8.3 Sensor configuration 8.3.1 Sensor configuration superordinated switch-off level 1 Single-channel emergency stop circuit with command devices to DIN ISO 13850 ( 418) and 60947-5-5 (Fig. 8) Wire breakage and earth leakage in the control circuits are detected. Dual-channel emergency stop circuit with command devices to DIN ISO 13850 ( 418) and 60947-5-5 (Fig. 9) Wire breakage and earth leakage in the control circuits are detected. Cross-wire shorts between the control circuits are not detected. X2 Fig. 5 left = switch-off level 1 right = switch-off level 2 (SRB 202CA, SRB 202CS and SRB 202CA/Q) Dual-channel emergency stop circuit with command devices to DIN ISO 13850 ( 418) and 60947-5-5 (Fig. 10) Wire breakage and earth leakage in the control circuits are detected. Cross-wire shorts between the control circuits are detected. 0 VDC External reset button (Fig. 6) The external reset button is wired to the terminals (with edge detection for switch-off level 1) and X2 (without edge detection for switch-off level 2). The external reset button is integrated in the feedback circuit in series. * Automatic start at switch-off level 2: the reset button must be replaced with a bridge. * S22 Fig. 8 SRB 202CA, SRB 202CS, SRB 202CA/T, SRB 202CS/T S22 Fig. 9 SRB 202CA, SRB 202CS, SRB 202CA/T, SRB 202CS/T S22 Fig. 10 SRB 202CA/Q, SRB202CA/QT 8.3.2 Sensor configuration, partially functioning switch-off level 2 X2 Fig. 6 left = switch-off level 1 right = switch-off level 2 (SRB 202CA/T, SRB 202CS/T and SRB 202CA/QT) Automatic start (see Fig. 7) The automatic start is programmed by connecting the feedback circuit to the terminals (referring to the switch-off level 1) and X2 (referring to the switch-off level 2). Feedback circuits are not required to be replaced by a bridge. When the safety-monitoring module is used with the operating mode Automatic start, an automatic restart after a shutdown in case of emergency must be prevented by the upstream control to 60204-1 paragraph 9.2.5.4.2 and 10.8.3. * An external reset button for a manual start can be installed in switch-off level 2. * Single-channel guard door monitoring circuit with interlocking devices to 1088 (Fig. 11) With one positive-break position switch. Wire breakage and earth leakage in the control circuits are detected. Dual-channel guard door monitoring circuit with interlocking device to 1088 (Fig. 12) With at least one positive-break position switch The control system recognises wire-breakage and earth faults in the control circuit. Cross-wire shorts between the control circuits are not detected. Dual-channel guard door monitoring circuit with interlocking device to 1088 (Fig. 13) With at least one positive-break position switch The control system recognises wire-breakage and earth faults in the control circuit. Cross-wire shorts between the control circuits are detected. S31 S31 S41 S31 S43 X2 Fig. 7 left = switch-off level 1 right = switch-off level 2 (SRB 202CA, SRB 202CS and SRB 202CA/Q) S42 Fig. 11 SRB 202CS, SRB 202CS/T S42 Fig. 12 SRB 202CS, SRB 202CS/T S44 Fig. 13 SRB 202CA, SRB 202CA/T, SRB 202CA/Q, SRB 202CA/QT 5

8.3.3 Sensor configuration Dual-channel control of magnetic safety switches to 60947-5-3 (see Fig. 14) The control system recognises wire-breakage, earth faults and cross-wire shorts in the control circuits. S31 S43 S44 Fig. 14 SRB 202CA, SRB 202CA/T, SRB 202CA/Q, SRB 202CA/QT The connection of magnetic safety switches to the SRB 202C.. safety-monitoring modules is only admitted when the requirements of the standard 60 947-5-3 are observed. As the technical data are regarded, at least the following requirements must be met: Switching capacity: min. 3 W Switching voltage: min. 30 VDC Switching current: min. 10 ma For example, the following safety sensors from Schmersal meet the requirements: BNS 33-11z, BNS 33-12z-2063, BNS 33-11z-2063 BNS 250-11z BNS 120-11z BNS 180-11z BNS 303-11z Caution! When sensors with LED are wired in the control circuit (protective circuit), the following rated operating voltage must be observed and respected: with a max. tolerance of 5 %/+ 20 % 8.4 Actuator configuration Single-channel control (see Fig. 15) Suitable for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. S = Feedback circuit: if the feedback circuit is not required, establish a bridge. A = switch-off level 1, B = switch-off level 2 * Disabling of the enabling circuits 13-14, 13-24 when switch-off level 1 is triggered, disabling of the enabling circuit 13-24 when switch-off level 2 is triggered Dual-channel control (Fig. 16) Suitable for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. S = Feedback circuit: if the feedback circuit is not required, establish a bridge. A = switch-off level 1, B = switch-off level 2 * Disabling of the enabling circuits 13-14, 13-24 when switch-off level 1 is triggered, disabling of the enabling circuit 13-24 when switch-off level 2 is triggered L1 N X2 13 14 24 * * Fig. 15 Fig. 16 N X2 13 14 * 24 * Otherwise availability problems could occur, especially in series-wired sensors, where a voltage drop in the control circuit is triggered by LED's for instance. 6

8.5 Flowcharts SRB 202CA, SRB 202CS, SRB 202CA/Q see Fig. 17 a) b) c) d) e) f) g) SRB 202CA/T, SRB 202CS/T, SRB 202CA/QT see Fig. 18 a) b) c) d) e) f) g) Fig. 17 a) U B ; b) Sensor level 1; c) Reset switch-off level 1; d) Sensor level 2; e) Reset switch-off level 2; f) Authorized operation 13-14 switch-off level 1; f) Authorized operation 13-24 switch-off level 2; Fig. 18 a) U B ; b) Sensor level 1; c) Reset switch-off level 1; d) Sensor level 2; e) Reset switch-off level 2; f) Authorized operation 13-14 switch-off level 1; f) Authorized operation 13-24 switch-off level 2; 7

Appendix 8.6 EC Declaration of conformity EC Declaration of conformity Translation of the original declaration of conformity valid as of December 29, 2009 Elan Schaltelemente GmbH & Co. KG Im Ostpark 2 35435 Wettenberg Germany Internet: www.elan.de We hereby certify that the hereafter described safety components both in its basic design and construction conforms to the applicable European Directives. Name of the safety component: SRB 202CS / SRB 202CS/T / SRB 202CA/T / SRB 202CA/QT / SRB 202CA / SRB 202CA/Q Description of the safety component: for emergency stop circuits, guard door monitoring, magnetic safety switches and AOPD's Harmonised EC-Directives: 2006/42/EC EC-Machinery Directive 2004/108/EC EMC-Directive Person authorized for the compilation of the technical documentation: Ulrich Loss Möddinghofe 30 42279 Wuppertal Notified body, which approved the full quality assurance system, referred to in Appendix X, 2006/42/EC: TÜV Rheinland Industrie Service GmbH Alboinstraße 56 12103 Berlin ID n : 0035 Place and date of issue: Wuppertal, October 6, 2009 SRB202C...-B- Authorised signature Heinz Schmersal Managing Director Note The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. Elan Schaltelemente GmbH & Co. KG Im Ostpark 2, D - 35435 Wettenberg Postfach 1109, D - 35429 Wettenberg Telefon: +49 (0)641 9848-0 Telefax: +49 (0)641 9848-420 E-Mail: info-elan@schmersal.com Internet: www.elan.de 8