Connections That Last

Similar documents
Cardiology Products H6317

Direct to the right choice

Propaq LT Outline Train the Trainer

Kendall DL Cable and Lead Wire System. Your Disposable ECG Cable and Lead Wire Safety Solution. Safe, Simple, Secure

Atlas Monitor Outline Train the Trainer

SpotOn Temperature Monitoring System. SpotOn. Temperature Monitoring System. Model 370 Installation and Service Manual

Track the truth. Give no false assurance. Do no harm. Nellcor SpO 2. Module for use with Philips IntelliVue * Patient Monitors

Ordering Information. Mega Soft Return Electrodes. Mega Soft. Mega Soft Dual Cord. Mega Soft Pediatric. Mega Soft. Patient Return Electrodes

Connex Integrated Wall System 2.2 Software Version

EM-MED. EmTherm. warming. cabinets

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

The FTA-02 Fiber Arranger

Time saving with simple operation. Height-adjustable arm. Swivel range suction head. Internal cable routing. ergo vac LT.

Installation Instructions

SELF-ADHESIVE FILM INSTALLATION GUIDE

EXTERNAL CARDIAC AMBULATORY TELEMETRY

CARELINC MEDICAL EQUIPMENT & SUPPLY APNEA MONITOR SET-UP CHECKLIST

The feedhorn heaters consist of heater wire attached to a strap and covered with heatshrink. They are attached to a rib on the feedhorn.

Bravo II. High Performance Multi-Purpose Speaker

Clean! Clean working by Qdel. Qdel laminating supplies Hamburgstraat 9 NL-7575 EG Oldenzaal T: E: I :

C363, C363DT, C563, C763, C563DT, C383, C583, C783 In-Ceiling Architectural Loudspeaker Instruction Manual

v.a.c.simplicity TM Quick Reference Guide Power Connection Canister Battery Charging Light Control Panel

FATG OM 0604 OWNERS MANUAL. Anywhere. Everywhere. Fresh Air... To Go.

1 Appendix - Product Specifications

Neck Support Pillow User Instructions. Simple Stuff Works

Hemovac Wound Drainage Family. The Time-Tested System for Reliable Wound Drainage and Auto-Transfusion

Neck Support Pillow. It is unsafe to assemble and use the equipment without fully reading the instructions. 1. User Assistance INSTRUCTIONS FOR USE

Contents. AFTER SALES SUPPORT / FJ142L

TOYOTA SIENNA MY LOWER DOOR MOLDING Preparation

Guide, Quick Start, Short, X-100 System

TOYOTA SIENNA MY LOWER DOOR MOLDING Preparation

Side Lying Leg Support

Product instruction manual Easymount Wide Format Laminators

Service Manual. Model Number: Compact Fireplace DF203A DF2006. UL Part Number to 800

Dual Channels - TENS Electronic Pulse Massager Unit Model No.: MT-5180

Make critical-care decisions with fast, accurate results.

BEDSIDE MONITORING Dash 3000/4000 V5

Tovatech LLC Phone (973) Rutgers St, Maplewood, NJ 07040

Product Data Sheet. NeverStrip UV Resilient. Matte. A NeverStrip Instant Film Coating. UV Resilient Matte

INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY)

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. COMPOSITE FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

THE CLINICAL CONNECTION

Harmony User s Guide 1

SharperImage.com T.E.N.S. Massager with Handheld Control Operating Manual

All Truphatek's products:

Soiled garments reflect less radiant heat. Materials saturated with hydrocarbons will absorb not deflect radiant heat from a fire.

MODEL NO.: Empressa S330 DIGITAL STEAM PRESS INSTRUCTION MANUAL

Flexible Heaters. of Silicone Rubber & Kapton

Scritto Da: StacyAnn Brown

VMS+ Cleaning and Disinfection Guide

Metal, ceramic, plastic package products

POWERSTEAMER USER GUIDE BGST1566 SERIES

ST. JOHN HEALTH SYSTEM PHYSICIAN SAFETY MANUAL

Technical Details. Important Safety Instructions READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE

Owner s Manual for the Cordless Backpack

Alarm Fatigue in the ICU. Lynn Maguire MS, RN, PMC, NE-BC

Operator s Manual. Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes

Transport Pro Patient Monitor Operator s Manual Software Version 2.1

Installation Instructions READ BEFORE INSTALLING UNIT For SLO3 Air Conditoner (8,000~12,000 BTU)

CONTENTS CONTROLS 3-STAGE AIR PURIFICATION. X This product is suitable for 120V only. User Manual. Odor sensor. ➌ PlasmaWave

Vital Signs Monitor 300 Series

WIRELESS WaterSwitch

IMPORTANT SAFETY INFORMATION

Installation Instructions

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

CDC266 Reverse Action

OPTIMIZING PERFORMANCE IN SPRAY OPERATIONS

AIR. Low-Air Loss Combined with. Advanced Wound Therapy & Fall Prevention in a Non-Powered Mattress. Non-Powered Therapy

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Insta-ThermTM. All-in-One Thermometer. Instructions. Ear Forehead Ambient Room Temperature

METHOD OF TEST FOR PREPARATION OF MARSHALL SPECIMENS 3. APPARATUS. Canadian Council of Independent Laboratories June 2016 LS-261 R27 ASTM D

GE Healthcare. Dash Variable-Acuity Monitoring

Barrel Blitz Universal P Instructions

ADVANCED PATIENT WARMING TECHNOLOGIES

GENERAL PRECAUTIONS. Do NOT dismantle.

5200 Flip-!t & 7340 Flip-!t Select Series

The soft, durable surface protector. Perforated 59cm x 50m Non Perforated 55cm x 80m roll

3/4 HP Model Trimmer Operating Instructions

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

Enteral Pump Instructions for Use To Assemble When the low

Wanderer Security Systems FOR COMPLETE RESIDENT SAFETY

QUICK START IMPORTANT: PLEASE READ BEFORE OPERATING CLEANER ENG ESP FRA DEU ITL POR QUICK START OPERATOR MANUAL FOR THE FOLLOWING CLEANERS

Quick Reference Guide STAN S31 fetal heart monitor. Power ON/OFF. ST Analysis (Fetal ECG analysis)

S-Series 3 Person Infrared Sauna IG-870-SH/S870 User Manual

Administration of AMBISOME Using the GemStar Pump

W363, W563, W763, W553L, W383, W583, W783, W873, W893 In-Wall Architectural Loudspeaker Instruction Manual

Register your purchase. Keep this inforrnation. For Electrolux service

Kapton and Silicone Rubber Flexible Heaters

Lyra. Speaker system. by Thrax Audio. Operating Manual. Manual issued 25/11/2014 CAUTION

Bose 201 and 301 Series V Direct/Reflecting Speakers Owner s Guide

User Manual / Installation Instructions

ICB VEGETABLE SLICER Model HLC-300 User and Maintenance Manual

Safety and Compliance Information

1. Product Name. 2. Product Code. 3. Colour/Texture. 4. Brief Description. Chatsworth Furniture (Deluxe Fabrics)

IPad Air 2 REPAIR GUIDE. Version Edition

Invacare Propad. General. Cushion User Manual. General information. Warranty. Standards and regulations. Symbols in this user manual.

LEAD-LINED LABORATORY FURNITURE

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

Transcription:

Connections That Last Electrodes 974 06 Over 40 Years of Trusted Connections

Table of Contents Section Page Performance Priced Options Repositionable Short Term Diagnostics 4 Pediatric Electrodes 4 Pre-wired Infant & Neonatal 5 Solutions for Fragile Skin 6 Diaphoretic Solutions 7 Fluid Resistant Solutions 7 Solutions for Skin Prepping 8 Suggested Applications 9 Application and Removal Instructions 0 Troubleshooting EKG Traces

Product Reference Guide Patient Monitoring Solutions Electrodes Performance Priced Options Today, facilities are challenged to reduce operating costs while maintaining high-quality patient care. With help from M, you can meet the challenge by standardizing electrodes without compromising on product performance. From value-priced electrodes that feature good performance across most applications to our best electrodes for your most demanding applications, M has you covered. Value-priced M Foam Monitoring Electrodes (8/44) These electrodes let you reduce costs while maintaining quality patient care. Three-day wear time. Clinically tested to provide good electrode performance for up to three days. 0 day out of bag freshness guarantee. Packaged for efficiency. The 8 electrode comes in individual patient packs of and 5 electrodes. Our 8 and 44 electrodes are available in bulk packs of 50 electrodes. All electrode liners are perforated to be torn off individually. Universal Foam Monitoring Electrodes (560/570) These electrodes feature a larger adhesive area and gel area to improve performance. Diaphoretic. Five-day wear time. Clinically tested to provide good electrode performance for up to five days. 45 day out of bag freshness guarantee. Packaged for efficiency. Our 570 electrode comes in individual patient packs of and 5 electrodes as well as bulk packs of 50 electrodes. Our 560 electrode is available in bulk packs of 50 electrodes. Repositionable Electrodes For your most demanding applications, our 660/670 monitoring electrodes, with a full coverage conductive surface area, provide improved trace quality. Soft Cloth Monitoring Electrodes (660/670) Larger conductive area. The conductive surface area of our Red Dot Repositionable Monitoring Electrodes is larger than that of conventional electrodes. This results in improved EKG trace quality. Comfortable and conformable. The low-profile, soft cloth backing provides ease of application and removal, helps to improve patient comfort and reduces the risk of electrodes catching on medical devices, drapes, gowns or bedding. Adhesion choices. Red Dot Repositionable Monitoring Electrodes are available in two levels of adhesion. Both are quick to stick on skin and gentle on removal, but the Red Dot Repositionable Monitoring Electrode 670 is the preferred choice when more aggressive adhesion is needed. M Foam Monitoring Electrode 8.57" x." (4 cm x. cm) Sticky gel Monitoring Electrode with Foam Tape and Sticky Gel 560.6".6" (4. cm.5 cm) Repositionable Monitoring Electrode 660.57"." (4 cm. cm) Radiolucent M Foam Monitoring Electrode 44.57"." (4 cm. cm) Radiolucent, Sticky Gel Monitoring Electrode with Foam Tape and Sticky Gel 570.6".6" (4. cm.5 cm) Radiolucent, with abrader Repositionable Monitoring Electrode 670.57"." (4 cm. cm) Radiolucent, stronger adhesive than 660 MR conditional. The Monitoring Electrodes model numbers 44, 570, 660 and 670 have been demonstrated to be MR conditional. M Technical Bulletin 70-00-9070-4. Repositionable Performance Priced

4 Product Reference Guide Patient Monitoring Solutions Electrodes Short Term Diagnostics Pediatric Short Term Diagnostics The unique needs of resting EKG monitoring are met with the M family of electrodes designed for this critical diagnostic application. Easy to apply and remove. The reverse tab placement provides quick and easy access to the electrode for single-handed application. The tab is convenient for leadwire placement and for ease of removal. Excellent adhesion. Excellent adhesion with the flexibility to securely reposition the electrode helps save clinician time and facility cost. 60 is preferred choice when more aggressive adhesion is needed. Intimate skin contact. The conductive adhesive on Resting EKG Electrodes provides intimate skin contact to help ensure accurate EKG traces - even on challenging sites. Defibrillation recoverable. Red Dot Resting EKG Electrodes can continue to be used after defibrillation. Pediatric Electrodes The tender skin of younger pediatric patients is a consideration when selecting the backing and adhesive characteristics of an electrode. In addition to the pre-wired electrodes, M also offers gentler adhesives and comfortable backings in traditional electrodes for these special patients. Gentle adhesive. Helps reduce risk of skin trauma. Smaller footprint for children. Accommodates smaller chest sizes. Pediatric Monitoring Electrode with M Micropore Tape Backing 48-50.75" dia. (4.4 cm dia.) Solid gel Resting EKG Electrode 0 0.8"." ( cm cm) Gentle adhesive Resting EKG Electrode 60 0.8"." ( cm cm) Repositionable, stronger adhesive than 0 EKG Monitoring Electrode 68-.5" dia. (. cm dia.) Conductive adhesive Soft Cloth Radiolucent

Product Reference Guide Patient Monitoring Solutions Electrodes 5 Pre-wired Infant & Neonatal Electrodes M has a family of pre-wired electrodes specifically designed for newborns and infants. Features include: Pre-wired and colour-coded. For ease of application and trace quality. Gentle adhesive. Helps reduce risk of skin trauma on neonatal skin prior to full barrier formation. Two leadwire lengths: 8" (45.7 cm) 80, 8, 8, 84 " (55.8 cm) 69T. Radiolucent: 69T, 8, 8, 84 Smaller footprint for neonates. Accommodates smaller chest sizes. Neonatal Limb Band Monitoring Electrode, Pre-Wired 84 0.9" 0.7" (. cm.8 cm) Radiolucent 8" (45.7 cm) leadwire length Neonatal/Infant Pre-Wired Monitoring Electrode, Radiolucent with Clear Tape 69T. 0.8".57" ( cm x 4 cm) " (55.8 cm) leadwire length Pre-wired Infant & Neonatal Infant, Pre-Wired, Radiolucent Monitoring Electrode 8." 0.9" (. cm. cm) 8" (45.7 cm) leadwire length Neonatal, Pre-wired, Non-Radiolucent Monitoring Electrode with Soft Cloth 80 0.9" 0.9" (. cm. cm) 8" (45.7 cm) metal leadwire Neonatal, Pre-wired, Radiolucent Soft Cloth Monitoring Electrode 8 0.9" 0.9" (. cm. cm) 8" (45.7 cm) leadwire length

6 Product Reference Guide Patient Monitoring Solutions Electrodes Solutions for Fragile Skin In today s patient population, fragile skin is often a concern whether due to age, medication or repeated removal of adhesive products. It s a delicate balance to protect the patient s skin and maintain good adhesion to obtain acceptable EKG trace quality. Conformable backings to follow skin contours. M Micropore Soft Cloth Tape backings are low profile to help minimize catching of medical devices and fabrics. This helps reduce the risk of early lift which often necessitates electrode removal and replacement. Gentle adhesives. Pressure Sensitive Adhesives (PSAs) need both pressure and warmth (from the patient s body) to achieve optimum adhesion. M has formulated these electrodes' PSA to be gentle on the skin. Small size option. The 68- electrode is a compact addition to our fragile skin portfolio, well-suited for both pediatric and adult patients. Gentle, conductive adhesive over the entire electrode may help improve trace quality. Low profile increases conformability and comfort. Lift tab makes electrode removal easy. Soft Cloth Monitoring Electrode 55-50.4" dia. (6. cm dia.) with abrader, solid gel Fragile Skin Soft Cloth Monitoring Electrode 68-.5" dia. (. cm dia.) Conductive adhesive Radiolucent Monitoring Electrode with M Micropore Tape Backing 9.4" dia. (6. cm dia.), solid gel Monitoring Electrode with M Micropore Tape Backing 49-50.4" dia. (6. cm dia.) with abrader, solid gel

Product Reference Guide Patient Monitoring Solutions Electrodes 7 Diaphoretic Solutions The diaphoretic patient s skin presents a challenge in maintaining reliable contact for a quality EKG trace. M offers product solutions to address the challenge. Large footprint for greater adhesive area. Diaphoretic Monitoring Electrodes combine both a greater surface area and a strong adhesive to help improve trace quality. Foam and soft cloth backings. Backing choices for conformability, patient comfort and low profile. Abrader for gentle skin prep. Monitoring Electrodes 7 incorporate an abrader for gentle skin abrasion. Gentle skin abrasion results in lower skin impedance and improved EKG trace quality. See also: Performance priced product 560, 570, 8, 44 Fluid Resistant Solutions Several Electrodes have a foam polyethylene backing that is fluid-resistant. Thus, they don t absorb liquids which could reduce the electrode s ability to adhere well. These electrodes are well suited for applications where fluids are present. Two footprints. The surface area can be selected to help meet patient needs. 5, 56-50, 59 - " (5. cm) diameter 7 -.75" (4.4 cm) diameter Diaphoretic Foam Monitoring Electrode 0." " (5.6 cm 5. cm), solid gel Diaphoretic Soft Cloth Monitoring Electrode 7-50." " (5.6 cm 5. cm), solid gel with abrader Diaphoretic Soft Cloth Monitoring Electrode." " (5.6 cm 5. cm), solid gel Foam Monitoring Electrode 560.6".6" (4. cm.5 cm) with Sticky Gel Fluid Resistant Diaphoretic Clear Plastic Monitoring Electrode 5 " dia. (5. cm dia.) Solid gel Foam Monitoring Electrode 56-50 " dia. (5. cm dia.) with wet gel, abrader Foam Monitoring Electrode 7.75" dia. (4.4 cm dia.) solid gel Foam Monitoring Electrode 59 " dia. (5. cm dia.) with solid gel, abrader

8 Product Reference Guide Patient Monitoring Solutions Electrodes Solutions for Skin Prepping Advanced diagnostic EKG and EKG monitoring equipment demand excellent skin prep for optimal results. Virtually every EKG monitor and electrode supplier strongly recommends skin prep for optimal performance, and for good reason it works. Removing the non-conductive skin layer with an effective skin prep helps improve the traces. Clear traces help reduce unnecessary print-outs, save EKG paper and waste fewer electrodes. M electrodes available with built-in abrader: 49, 56, 59, 7, 570 Factors Affecting Trace Quality Site selection Use of alcohol on skin Lack of skin abrasion Poor electrode adhesion Dried-out electrodes Trace Prep 6 (6 rolls/case) Skin Prepping Proper skin preparation prior to electrode placement lowers skin impedance and can significantly reduce artifact in all electrode applications. Monitoring Electrode with blue abrader: 49, 55, 56, 59, 7 Foam Monitoring Electrode 570 - Radiolucent front and back with blue abrader Oster, C. Proper Skin Prep Helps Ensure EKG Trace Quality. Biomedical Instrumentation and Technology. Volume 4 No, May/June 000, pp9-.

Product Reference Guide Patient Monitoring Solutions Electrodes 9 Suggested Applications 8 44 560 570 660 670 0 60 69T 80 8 8 84 9 49-50 68-7 5 7 EMS/ED ICU/CCU Telemetry/ Holter/Event OR Cath Lab Stress Test Cardiac Rehab Echo-Cardio EKG Lab Lead EKG Echo-Cardio Peds ICU NICU Peds OR ICU

0 Product Reference Guide Patient Monitoring Solutions Electrodes Application and Removal Instructions Application Instructions Removal Instructions PREPARE THE SKIN Application sites must be clean, dry, and free of any body lotions. Cleaning with isopropyl alcohol should be avoided or limited to situations in which electrode adhesion is an issue (excessively oily or lotion covered skin). If alcohol is used, allow it to dry prior to electrode application. Excessive hair at the site should be removed by clipping. Gently abrade the skin using the abrader pad on the back of some electrodes (blue strip or gray disc) or M TM Red Dot TM Trace Prep. Make an X on the skin with the abrader. Apply the electrode and then gently rub around the electrode to set the pressure sensitive adhesive. REMOVE In order to remove, loosen one side of the electrode. Grasping the full width of the electrode, slowly and gently pull it back over itself. Electrodes should be removed in the direction of hair growth whenever possible. Keep the electrode close to the skin surface as you pull it back, and support the skin immediately adjacent to the adhesive being removed. APPLY THE ELECTRODE If using snap connection leadwires, connect the leadwires to the electrodes before placing the electrode onto the patient. Avoid pressing on the stud when electrode is on the patient. After placing the electrode on the patient, round your finger around the front label to activate the pressure sensitive adhesive.

Product Reference Guide Patient Monitoring Solutions Electrodes Troubleshooting EKG Traces Troubleshoot each artifact in order, starting with Equipment Interference Cabling Electrodes Electrical Continuity Muscle Movement Skin Impedance Artifacts 4 No Base Line Check all connections/ perform continuity check dry-out proper cable Check lead switch and EKG machine set-up Base Line Wander Abrade skin Stop patient movement Check ground connections 4 Use same type of electrode at all sites 6 proper cable 5 static build-up 6 5 7 4 AC Noise Abrade skin May be untreatable involuntary muscle tremor Check ground connections dry-out May need fully shielded cable and lead wires Keep cable away from AC cord Turn off fluorescent lights and/or other equipment RA V V LA Intermittent Signal loose connections loose electrode or dry-out 4 Perform continuity check static build-up V V4 V5 V6 Motion Artifact Abrade skin Move electrodes off muscle mass loose connections 4 loose electrode or dry-out 7 Perform continuity check 5 Turn off fluorescent lights and/or other equipment 6 proper EKG machine set-up Low Amplitude Abrade skin Check all connections 4 dry-out 5 Turn off radio, TV and/or other equipment Check gain settings RL LL PR Interval R ST Segment -Lead Placement Resting Electrodes RA : Second intercostal space lateral right side LA : Second intercostal space lateral left side P T LL : Lower left lateral chest or left leg RL : Lower right lateral chest or right leg V : Fourth intercostal space to the right of the sternum Q S V : Fourth intercostal space to the left of the sternum V : Between V and V4 PR Segment QT Interval V4 : Fifth intercostal space along themid-clavicular line V5 : Fifth intercostal space between V4 and V6 V6 : Fifth intercostal space along the mid-axillary line

Ordering Information Performance Priced Options Product No. Description Packaging 8 Foam Monitoring Electrode,.57 inch x. inch (4 cm x. cm) with Sticky Gel 000 electrodes/case, 0/strip, 5 strip/bag, 0 bag/case 8- Foam Monitoring Electrode,.57 inch x. inch (4 cm x. cm) with Sticky Gel 600 electrodes/case, /strip, strip/bag, 00 bag/case 8-5 Foam Monitoring Electrode,.57 inch x. inch (4 cm x. cm) with Sticky Gel 000 electrodes/case, 5/strip, strip/bag, 00 bag/case 44 Foam Monitoring Electrode, Radiolucent,.57 inch. inch (4 cm. cm) with Sticky Gel 000 electrodes/case, 0/strip, 5 strip/bag, 0 bag/case 560 Foam Monitoring Electrode,.6 inch.6 inch (4. cm.5 cm) with Sticky Gel 000 electrodes/case, 0/strip, 5 strip/bag, 0 bag/case 570 Foam Monitoring Electrode, Radiolucent,.6 inch.6 inch (4. cm.5 cm) with Sticky Gel and Abrader 000 electrodes/case, 0/strip, 5 strip/bag, 0 bag/case Repositionable 660-660-5 670-670-5 Repositionable Soft Cloth Monitoring Electrode,.5 inch. inch (. cm. cm) Radiolucent with Lift Tab Repositionable Soft Cloth Monitoring Electrode,.5 inch. inch (. cm. cm) Radiolucent with Lift Tab Repositionable Soft Cloth Monitoring Electrode,.5 inch. inch (. cm. cm) Radiolucent with Aggressive Adhesive and Lift Tab Repositionable Soft Cloth Monitoring Electrode,.5 inch. inch (. cm. cm) Radiolucent with Aggressive Adhesive and Lift Tab 600 electrodes/case, /strip, strip/bag, 00 bag/case 000 electrodes/case, 5/strip, strip/bag, 00 bag/case 600 electrodes/case, /strip, strip/bag, 00 bag/case 000 electrodes/case, 5/strip, strip/bag, 00 bag/case Short Term Diagnostics 0 Resting Tab Style EKG Diagnostic Electrode with Gentle Adhesive, 0.8"." ( cm cm) 4000 electrodes/case, 0/card, 0 card/bag, 40 bag/case 60 Resting Tab Style EKG Diagnostic Electrode with Aggressive Adhesive, 0.8"." ( cm cm) 4000 electrodes/case, 0/card, 0 card/bag, 40 bag/case Pediatric 48-50 Micropore Paper Tape Monitoring Electrode,.75 inch dia. (4.4 cm dia.) with Solid Gel and Lift Tab 000 electrodes/case, 50/bag, 0 bag/case 68- Soft Cloth Monitoring Electrode,.5 inch dia. (. cm dia.) with Conductive Adhesive and Lift Tab 600 electrodes/case, /bag, 00 bag/case Pre-wired 69T 80 8 8 84 Neonatal Monitoring Electrode, Pre-Wired with Clear Tape, 0.8 inch x.57 inch ( cm x 4 cm) with inch (55.8 cm) Radiolucent Leadwire Neonatal Monitoring Electrode, Pre-Wired with Soft Cloth, 0.9 inch 0.9 inch (. cm x. cm) with 8 inch (45.7 cm) Metal Leadwires Neonatal Monitoring Electrode, Pre-Wired with Soft Cloth, 0.9 inch 0.9 inch (. cm x. cm) with 8 inch (45.7 cm) Radiolucent Leadwires Infant Monitoring Electrode, Pre-Wired with Soft Cloth,. inch 0.9 inch (. cm. cm) with 8 inch (45.7 cm) Radiolucent Leadwires Neonatal, Pre-wired Limb Band Monitoring Electrode, 0.9 inch x 0.7 inch (. cm x.8 cm) with 8 inch (45.7 cm) Radiolucent Leadwires 00 electrodes/case, /bag, 0 bag/box, 0 box/case 00 electrodes/case, /bag, 00 bag/case 00 electrodes/case, /bag, 00 bag/case 00 electrodes/case, /bag, 00 bag/case 00 electrodes/case, /bag, 00 bag/case Fragile Skin 9 Micropore Paper Tape Monitoring Electrode,.4 inch dia. (6. cm dia.) with Solid Gel and Lift Tab 000 electrodes/case, 50/bag, 0 bag/case 49-50 Micropore Paper Tape Monitoring Electrode,.4 inch dia. (6. cm dia.) with Solid Gel, Abrader and Lift Tab 000 electrodes/case, 50/bag, 0 bag/case 55-50 Soft Cloth Monitoring Electrode,.4 inch dia. (6. cm dia.) with Solid Gel, Abrader and Lift Tab 000 electrodes/case, 50/bag, 0 bag/case 68- Soft Cloth Monitoring Electrode,.5 inch dia. (. cm dia.) with Conductive Adhesive and Lift Tab 600 electrodes/case, /bag, 00 bag/case 8 Foam Monitoring Electrode,.57 inch x. inch (4 cm x. cm) with Sticky Gel 000 electrodes/case, 0/strip, 5 strip/bag, 0 bag/case 0 Diaphoretic Foam Monitoring Electrode,." " (5.6 cm x 5. cm) with Solid Gel 000 electrodes/case, 50/bag, 0 bag/case Diaphoretic Diaphoretic Soft Cloth Monitoring Electrode,. inch inch (5.6 cm x 5. cm) with Solid Gel and Lift Tab 000 electrodes/case, 50/bag, 0 bag/case 44 Foam Monitoring Electrode, Radiolucent,.57 inch. inch (4 cm. cm) with Sticky Gel 000 electrodes/case, 0/strip, 5 strip/bag, 0 bag/case 7-50 Diaphoretic Soft Cloth Monitoring Electrode,. inch inch (5.6 cm x 5. cm) with Solid Gel, Abrader and Lift Tab 000 electrodes/case, 50/bag, 0 bag/case 560 Foam Monitoring Electrode,.6 inch.6 inch (4. cm.5 cm) with Sticky Gel 000 electrodes/case, 0/strip, 5 strip/bag, 0 bag/case 570 Foam Monitoring Electrode, Radiolucent,.6 inch.6 inch (4. cm.5 cm) with Sticky Gel and Abrader 000 electrodes/case, 0/strip, 5 strip/bag, 0 bag/case 5 Clear Plastic Monitoring Electrode, inch dia. (5. cm dia.) with Solid Gel and Lift Tab 000 electrodes/case, 50/bag, 0 bag/case Fluid Resistant 7 Foam Monitoring Electrode,.75 inch dia. (4.4 cm dia.) with Solid Gel and Lift Tab 000 electrodes/case, 50/bag, 0 bag/case 56-50 Foam Monitoring Electrode, inch dia. (5. cm dia) with Wet Gel, Abrader and Lift Tab 000 electrodes/case, 50/bag, 0 bag/case 59-50 Foam Monitoring Electrode, inch dia. (5. cm dia) with Solid Gel, Abrader and Lift Tab 000 electrodes/case, 50/bag, 0 bag/case 560 Foam Monitoring Electrode,.6 inch.6 inch (4. cm.5 cm) with Sticky Gel 000 electrodes/case, 0/strip, 5 strip/bag, 0 bag/case 570 Foam Monitoring Electrode, Radiolucent,.6 inch.6 inch (4. cm.5 cm) with Sticky Gel and Abrader 000 electrodes/case, 0/strip, 5 strip/bag, 0 bag/case M Health Care Infection Prevention Division P.O. Box 5757 London, ON N6A 4T Canada www.m.ca M Health Care 50 Conway Avenue St. Paul, MN 5544 USA M, M Science. Applied to Life., Red Dot and Micropore are trademarks of M. Used under license in Canada. 06, M. All rights reserved. 50074 E BA-5-0686 To learn more about the M Red Dot Electrodes, call the M Health Care Helpline at -800-64-577 or visit www.m.com/patientmonitoring