Nuts and Bolts on Humidification: Active or Passive During Pediatric Invasive Mechanical Ventilation?

Similar documents
Humidification for patients with respiratory failure

In the 1940s in Chicago, Illinois, a group of oxygentank technicians began meeting with doctors concerned with lung disease. This group named itself

Investigation of Correct Application of Ventilators Humidifier Systems Before and After Nursing Education in Intensive Care Units

Artificial humidification for the mechanically ventilated patient

A basic introduction about the principles of humidity

Humidification in anaesthesia and critical care

product overview Adult Care Solutions

PRODUCT OVERVIEW. Adult Care Solutions

Humidification & Filtration

AARC Clinical Practice Guideline

Deutsche Bank Securities 27th Annual Health Care Conference

Coaxial Circuits. Breathing Systems

Dräger VentStar Helix heated (N) plus Consumables and Accessories

HAMILTON-H900. Intelligent humidification for all patient groups

The loss of moisture and heat that occurs when the

ConchaTherm Neptune Heated Humidifier User s Manual /07 English (EN)

Forward Looking Statements

Cl inician Training Packet

NZX Australasian Media Day 12 November 2003

Active Humidification

Table of Contents. isleep 20 users manual

Overview & H1/Q2 FY03 Update Auckland, Wellington, Melbourne, Sydney November 2002

A Caregiver Guide for Tracheostomy Care at Home

In Vitro Evaluation of an Active Heat-and-Moisture Exchanger: The Hygrovent Gold

GoodKnight H 2 O. User's Manual. Heated Humidifier. Ref. : M-146DFU00-20 Revision D

ATMOS Bronchial Suction

Complex Care Hub: Oral and Nasal Suctioning

Moisturizing and mechanical characteristics of a new counter-flow type heated humidifier

740 SELECT. Multi-Parameter Monitor

CPAPSolutions. Product Profile. Overview: The Family of SleepStyle TM CPAP Solutions

Ohio Medical s Push-To-Set TM Intermittent and Continuous Vacuum Regulators

User guide User guide English

Servo i. CRC 335 University of South Alabama Cardiorespiratory Care

User guide User guide English

THE EFFECTS OF THE HEAT AND MOISTURE EXCHANGER ON HUMIDITY, AIRWAY TEMPERATURE, AND CORE BODY TEMPERATURE

Oxylog VE300 Emergency & Transport Ventilation

Oxylog VE300 Emergency & Transport Ventilation

SPECIFICATION FOR MULTIPARAMETER MONITOR

INSTRUCTION MANUAL FOR THE NIPPY 2 POSITIVE PRESSURE VENTILATOR

Influence of Ambient Temperature and Minute Ventilation on Passive and Active Heat and Moisture Exchangers

CLINICAL MANUAL REF JH 6/7/10 CLINICAL MANUAL

Influence of Ambient and Ventilator Output Temperatures on Performance of Heated-Wire Humidifiers

Ohio Medical s Push-To-Set TM Intermittent and Continuous Vacuum Regulators (ISO & ANSI)

5580 S. Nogales Highway Tucson, AZ Phone: (800) Fax: (520) ANAPOD Instructions For Use

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

Alarm Fatigue in the ICU. Lynn Maguire MS, RN, PMC, NE-BC

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

Thoracic drainage upgrade:

This policy has been adopted by UNC Health Care for its use in infection control. It is provided to you as information only. Infection Control Manual

Alarm Management at Boston Medical Center A Roadmap to Safe Silence

Make the Connection. Compatibility Guide for Noninvasive Systems Validated With INOmax DS IR Plus

Sanosil disinfectant for air washers / air humidifiers

Blow Dryer and Paper Towel Microbiological Comparison. Presented by Sean Bailey

Surgical Suction: Silent and powerful!

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 1 history, principles and efficiency

Puritan Bennett 980 Ventilator System Planning for Training Checklist

Drying principles and general considerations

Impact of leaks and ventilation parameters on the efficacy of humidifiers during home ventilation for tracheostomized patients: a bench study

Effect of Relative Humidity on Oven Temperature of Locally Design Solar Carbinet Dryer

Clinical Alarm Effectiveness: Recognizing & Mitigating Risk to Patient Care

PRODUCT NUMBER: Rd40 Aluminium Canister AXP3

Preventing ECMO Patient Harm While Using Remote Monitoring: A Case Report. Emily Thunstrom

Bipap A30/40 ventilator and System One humidifier

HANDS-ON MODULE 5. CLEANING FLOW-i V3.0

Oxylog VE300 Emergency & Transport Ventilation

Alarm Management. Objectives

I I IIII. United States Patent (19) McPhee. 5,537,996 Jul. 23, ) Patent Number: 45) Date of Patent:

INSTRUCTION MANUAL FOR THE NIPPY 3+ POSITIVE PRESSURE VENTILATOR This book must be kept with the machine

WILAmed AIRcon Respiratory Gas Humidifier. Experience High Tech Respiratory Gas Humidification. Made in Germany

Achieva. Ve nt i l at or with Flow Acceleration Limit and Apnea Backup. User s Manual

Structural Fires: Selected Guidance from NYS Department of Health

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Gomco Suction Equipment

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

The Ottawa Hospital OPERATING ROOM NURSING POLICY, PROCEDURE, PROTOCOL MANUAL

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

PRODUCT SPECIFICATIONS VENTILATOR Aeros-4600

Chapter 9: The basics of air preparation

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Operating Manual. Model HC254

Quick start guide. English

Gomco Suction Equipment

Safety Data Sheet 1. PRODUCT AND COMPANY IDENTIFICATION. Product name: Product Number:

REFERENCE GUIDE TO MAJOR INDOOR AIR POLLUTANTS IN THE HOME

Respiratory Function Solutions Sensor and Sampling Line Guide. Nellcor with OxiMax Technology Product Guide A Full Line of Oximetry Sensors

Kendall DL Cable and Lead Wire System. Your Disposable ECG Cable and Lead Wire Safety Solution. Safe, Simple, Secure

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

Omni (K) PATIENT MONITOR

A Method for Predicting the Matric Suction of Unsaturated Soils with Soil Color Recognition

ANALYSIS ON EFFECT OF TEMPERATURE ON MOISTURE SEPARATION IN AIR COMPRESSOR

A U T O S E R I E S Operating Manual

OMNI TOUCH SCREEN PATIENT MONITOR

Nutrient requirements during the acute phase: The baby stomach concept

BIO-SPECTRUM TREATMENT DEVICE

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

We ve invented suction. Again. The radial Tyscor V/VS suction machine COMPRESSED AIR SUCTION IMAGING DENTAL CARE 50 % HYGIENE. potential energy saving

Oxylog 2000 plus Pocket Guide Software version 1.n

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

CERCOSPORA BETICOLA INSENSITIVITY IN MICHIGAN AND MICHIGAN SUGAR COMPANY S RESISTANCE MANAGEMENT STRATEGIES

Transcription:

Nuts and Bolts on Humidification: Active or Passive During Pediatric Invasive Mechanical Ventilation? Tan Herng Lee, MSc, RRT-NPS, RRT-ACCS Senior Principal Respiratory Therapist, Children s Intensive Care Unit KK Women s and Children s Hospital 19 th August, 2017 1

Objectives Define humidification Why is humidification needed Different types of humidification devices Advantages and disadvantages of different types of humidification devices Which type of humidification devices should pediatric patients use? 2

Introduction Humidification = addition of water vapor and heat to inspired gas Heat and moisture exchange is a primary function of the upper respiratory tract, mainly the nose Optimal Humidification Properly conditioned inspiratory gas Maintain ciliary motility Decreases airway hyper-reactivity Keeps mucus from undergoing dehydration 3 Walsh BK. Pediatric Airway Maintenance and Clearance in the Acute Care Setting: How to Stay Out of Trouble. Respir Care 2011;56(9):1424 1440.

Effects of Inadequate Humidity Each point represents a single measurement coded as no dysfunction (diamond), mucus thick or thin (circle), mucociliary transport stopped (square), cilia stopped (X), or cell damage (+). Williams R. Relationship betw humidity and temp of inspired gas and function of airway. Crit Care Med 1996;24(11):1920-1929 4

Rabbit models to determine effects of mechanical ventilation under varying temperature and humidity on inflammatory cytokines present in bronchoalveolar lavage (BAL) fluids 40 rabbits: Control: n = 2, tissues used as reference Dry gas: n = 6 Experimental groups: Temp 30, 35, 40 and 45 o C, n = 8/group 5

Dry gas group showed increased tumour necrosis factor alpha levels (TNF-ἀ) TNF-ἀ and interleukin-8 (IL-8) levels reached that of control group when humidification temperature was increased to 40 o C Airway humidification in rabbits reduced mechanical ventilationassociated inflammatory response, cell cilia damage and airway water loss 6

Indications For Humidification Indications for Humidification Therapy: Humidifying dry medical gas Overcoming humidity deficit created when upper airway is bypassed Signs and symptoms of inadequate humidity Atelectasis Dry, non-productive cough Increased work of breathing Patient complained of airway dryness Thick, dehydrated secretions Walsh BK. Pediatric Airway Maintenance and Clearance in the Acute Care Setting: How to Stay Out of Trouble. Respir Care 2011;56(9):1424-1440. 7

Goals of Levels of Humidification Prevention of adverse effects of inadequate humidity? Minimum required humidity to prevent ETT occlusion? Make inspired gas at temperature and humidity equivalent to normal spontaneous breathing? physiologic humidity Provide optimal humidity to maximize mucociliary clearance? There appear to be no clinical demonstration of the superiority of delivering 40 vs 30 mg H 2 O/L or even 33 vs 30 mg H 2 O/L Optimum level of humidification appear to be > 30 mg H 2 O/L as absolute humidity (AH) < 30 mg H 2 O/L is associated with higher risk of ETT occlusion Branson RD. Conditioning Inspired Gases: The Search for Relevant Physiologic End Points. Respir Care 2009; 54(4):450-452. Wikes AR. Humidification in Intensive Care: Are We There Yet? Respir Care 2014; 59(5):790-793 8

9 The upper airway provides 75% of the humidification; this means that during mechanical ventilation, a humidity level of 0.75 x 44 mg/l = 33 mg/l needs to be generated

Types of Humidifiers 1. Active humidifiers Actively adding heat and/ or moisture to device-patient interface E.g. bubble humidifiers, passover humidifiers, heated humidifiers (HH) nebulizers of bland aerosols 2. Passive humidifiers Recycling heat and humidity from patient E.g. Heat and moisture exchangers (HMEs) AL Ashry HS, Modrykamien AM. Biomed Research International. Vol 2014, Article ID 715434, 12 pages. http://dx.doi.org/10.1155/2014/715434 10

Advantages and Disadvantages of Active and Passive Humidfiers Cerpa et al. The Open Respiratory Medicine Journal, 2015, 9, (Suppl 2: M5) 104-111 11

Performance of Humidifiers Variables affecting performance of humidifiers: i. Temperature ii. iii. iv. Higher temperature of the gas, the more water vapor it can hold (increased capacity) Surface area Greater the surface area of contact between water and gas, the more opportunity for evaporation to occur Time of contact The longer a gas remains in contact with water, the greater the opportunity for evaporation to occur Thermal mass The greater the mass of water, the greater its capacity to hold and transfer heat 12

Active Humidification as Gold Standard? Effective humidification for all patients, providing AH > 33 mg H 2 O/L Big issue is rain-out Regular drainage of water condensate in ventilator circuit Disconnection of circuit to drain water condensate De-recruitment desaturation, increased work of breathing, tachycardia Rapid bacterial colonization of ventilator tubings Higher risk of ventilator-associated pneumonia (VAP)? 13

Efficacy of HH Efficacy depends on environmental factors such as temperature Lower ambient temperature decrease AH delivered by the HH Increasing HH temperature to increase AH lead to more rain out Fassassi et al. Airway Humidification with a HME in Mechanically Ventilated Neonates. Intensive Care Med (200&) 33;336-343 14

Factors to consider when using HME Does it work (i.e. humidify)? Does it increase resistance Does it increase the occurrence of ETT obstruction? Does it increase dead space? Does it increase work of breathing? Does it increase the occurrence of VAP? Does cuff or cuffless ETT affect level of humidification? Picture from: AL Ashry HS, Modrykamien AM. Biomed Research International. Vol 2014, Article ID 715434, 12 pages. http://dx.doi.org/10.1155/2014/7 15434 15

Types of HME HME paper with compressed metallic elements to capture particles of exhaled water vapour and heat, holding and releasing it in the next inspiration Hygroscopic absorbing moisture from the air Hydrophobic unable to absorb water, increase moisture conservation by repelling water that is not absorbed 16 Cerpa et al. The Open Respiratory Medicine Journal, 2015, 9, (Suppl 2: M5) 104-111

Assessed 48 devices 32 = HME and 16 = antibacterial filters Some HMEs for pediatric use but most for adult use 37.5% of HMEs performed well ( 30 mg H 2 O/L) 25% of HMEs performed poorly (< 25 mg H 2 O/L) Mean difference between measured data and manufacturer data = 3.0 ± 1.4 mg H 2 O/L, p = 0.0001 Efficiency ~ 37 to 90% Huge variability in performance of commercially available HMEs 17

18

19 Performance of Pediatric HMEs

Performance of Pediatric HMEs Tested 10 pediatric HMEs Mechanically ventilating pediatric lung model at: 20 and 30 breaths/min Pressure control of 10, 15 and 20 cm H 2 O Leak of 3.2 L/min and 5.1L/min at pressure of 10 cm H 2 O 20

Performance of Pediatric HMEs Variable dead space and resistance Mean values of resistance between measured and those of the manufacturers report was -1.0±2.6 cmh 2 O/L/s (p = 0.27) 21

Impact of RR on AH of Pediatric HMEs Statistically nonsignificant 3% drop in AH when pressure control setting increased from 10 to 20 cm H 2 O With 3 HMEs, increasing RR statistically significantly increase AH 22

Performance of Pediatric HMEs in Presence of Leaks In the presence of leaks, all HMEs delivered < 30 mg H 2 O/L 23

Dead Space and AH of Pediatric HMEs Statistically significant correlation between HME dead space and AH values Higher dead space, higher AH greater capacity by HME to hold moisture 24

25

26

27

HME and ETT Obstruction First generation HMEs were hydrophobic Markedly affected by ambient temperature Low ambient temperature result in reduced humidification performance and high rates of ETT obstruction Latest generation of HME Both hydrophobic and hygroscopic components Better performance Lellouche et al. Influence of Ambient Temperature and Minute Ventilation on Passive and Active HMEs. Respir Care 2014;59(5):637-643 Cerpa et al. The Open Respiratory Medicine Journal, 2015, 9, (Suppl 2: M5) 104-111 28

Humidification Devices and ETT Obstruction ETT obstruction with HH and HME Both types of humidification result in progressive reduction in ETT diameter AH > 30mg H 2 O/L result in less occurrence of ETT obstruction Lellouche et al. Influence of Ambient Temperature and Minute Ventilation on Passive and Active HMEs. Respir Care 2014;59(5):637-643 29

Resistance of HME HME resistance increased: After several hours of use Increase in density of HME material Increase in flow Occlusion with secretions, blood or water Hygroscopic HME: Had less resistance than other types Lesser increase in resistance when saturated Lucato et al. Evaluation of Resistance in 8 Different HMEs: Effects of Saturation and Flow Rate/Profile. Respir Care 2005;50(5):636-643 30

Types of Humidification Devices and VAP Take home point from various guidelines on prevention of VAP: (Centers for Disease Control and Prevention, American Thoracic Society, European Care Bundle, European HAP Workgroup, VAP Guidelines Committee and the Canadian Critical Care Trials Group, American Association for Respiratory Care) No recommendation can be made for the preferential use of either HMEs or heated humidification to prevent VAP in patients requiring mechanical ventilation Colonization of ventilator tubings with HH does not translate to higher incidence of VAP No significant reduction in VAP rate with use of HMEs despite HMEs consisting of chemical substances that are poor media for bacterial growth No direct link between humidification devices and the pathophysiology of VAP (silent aspiration of contaminated oropharyngeal and/or gastric secretions) Wikes, A.R. Heat and Moisture Exchangers and Breathing System Filters: Their Use in Anesthesia and Intensive Care. Anesthesia, 2011, 66, pages 40-51. Richard, Jean-Damien. Gold Standard for Humidification: Heat Moisture Exchangers, Heated Humidifiers, or Both? Thomachot et al. Randomized Control Trial of Extended Use of Hydrophobic Condenser Humidifier: 1 vs. 7 Days. Crit Care Med 2002; 30:232-237 31

Safe Duration of HME use Passive humidifiers do not need to be changed daily for reasons of infection control. They can be used safely for at least 48 hours HMEs are better suited for short-term use ( 96 hours) and during transport BUT HMEs are the default and sometimes the only humidification device in some ICUs HMEs could be routinely used under cautious surveillance and replaced by HH if difficulty in suctioning occurs (Misset et al, Chest 1991 Jul;100(1):160-63) 32

. Crit Care Med 2007; 35:2843-2851 13 RCTs, 2580 patients > 15 years comparing HH and HME use No difference in: VAP Mortality Length of ICU stay, Duration of mechanical ventilation Episodes of airway occlusions HMEs were cheaper than HH in each of the RCTs 33

HH or HME? 33 trials, only 3 studies reported data for infants or children No overall effect on artificial airway occlusion, mortality, pneumonia or respiratory complications Higher PaCO 2 and minute ventilation with HME use Lower body temperature and lower cost with HME use Little evidence of an overall difference between HMEs and HH More research needed in the use of HME in pediatric and neonatal population 34

Limitations / Challenges Limited data and studies in pediatric population Most studies are in the adult setting Bulk of studies were done more than 10 years ago relevancy of these studies to current setting/practices Advances and changes in technology in HH, HME and Mechanical Ventilators Heterogeneity of studies Types of HMEs used Duration of studies Ability to translate lung model simulation studies to clinical practice Choice of Humidification Devices Clinical Judgement and Discretion 35

Humidification of inspired gas during mechanical ventilation is mandatory when an endotracheal or tracheostomy tube is present There are no contraindications to providing physiologic conditioning of inspired gas during mechanical ventilation 36

HMEs are contraindicated when: Frank bloody or thick, copious secretions Expiratory V T < 70% of delivered V T (i.e. when there is huge leak from artificial airways) During low V T ventilation (due to addition of dead space) Body temperature < 32 o C Spontaneous minute ventilation > 10 L/min HH to be used for patients with contraindications for HME use 37

38 Conclusion Humidification of inspired air is required for all patients with artificial airways Both HH and HME are able to provide adequate humidification Best approach to humidification is unclear Cognizant of variability in performance of different brands of HME No difference in rate of VAP, ETT obstruction, and other important clinical outcomes such as ICU length of stay, duration of mechanical ventilation and mortality between HH and HME use Choice of humidification devices depends on: Clinical assessment and judgment of patients condition i.e. elevated PaCO 2 Presence of leakage from artificial airways Presence of thick secretions, pulmonary edema and/or hemoptysis Institutional preferences and available resources

THANK YOU! tan.herng.lee@kkh.com.sg 39