CEE:3371 Principles of Hydraulics and Hydrology Project #2 Flow Measurement with a Weir

Similar documents
Chapter 4 - Preparation of Stormwater Site Plans

ENSC 388: Engineering Thermodynamics and Heat Transfer

2. HEAT EXCHANGERS MESA

MEMORANDUM. September 10, 2018

Surface Temperature Tests on an LST Fan Convector

TENNESSEE GAS PIPELINE COMPANY, L.L.C.

ENGG*4360 Soil-Water Conservation Systems Design. Course Description & Outlines - Fall 2010

DRAFT ONONDAGA LAKE CAPPING AND DREDGE AREA AND DEPTH INITIAL DESIGN SUBMITTAL H.3 STATIC SLOPE STABILITY ANALYSES

Ultrasonic Clamp-On Flow Meter Testing

CHECKLIST FOR PHASE II DRAINAGE REPORT

Introductionn to Compressible Flow (Gas Dynamics)

LABORATORY STUDY ON THE CONSOLIDATION SETTLEMENT OF CLAY-FILLED GEOTEXTILE TUBE AND BAGS

NATIONAL INSTITUTES of HEALTH FUME HOOD TESTING PROTOCOL. For CONSTANT VOLUME FUME HOODS

Draft Rhode Island Stormwater Design and Installation Standards Manual

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

2nd International Workshop. Labyrinth and Piano Key Weirs Paris - Chatou, France November 2013

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

PCE PRELIMINARY DRAINAGE ANALYSIS REPORT FOR WESTWOOD MIXED USE NEIGHBORHOOD PROJECT 772 NORTH FOREST ROAD TOWN OF AMHERST, ERIE COUNTY, NEW YORK

MD and Its Impact on Lab Facilities

Washington County, Maryland Division of Public Works Policy Manual

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

NATURAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING SYSTEMS. Technical Progress Report April 1,1995 to May 31,1995

NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY

Overall Heat Transfer Coefficient for Double-Pipe Heat Exchanger

Compression of Fins pipe and simple Heat pipe Using CFD

( )

Electric radiator test

MANUAL OF DESIGN, INSTALLATION, AND MAINTENANCE REQUIREMENTS FOR STORMWATER MANAGEMENT PLANS

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Pollutant Removal Benefits

Can We Have Too Much of a Good Thing? Lab

Erosion & Sediment Control Plan Application Form & Checklist

EEN-E Measurement and Control of Energy Systems DRYING OF BIOMASS IN A FIXED BED DRYER LABORATORY EXERCISE INSTRUCTIONS

Smoke Alarm Response Time:

Subject Name: RESERVOIR AND FARM POND DESIGN (2+1) CONTENTS

Eastern Mediterranean University Department of Mechanical Engineering Laboratory Handout

Mechanical Engineering Department Sheet (1)

Helicoil and Shell-Tube Heat Exchanger. Abdullah AlThomairi, Ahmed Sajjad, and Faris AlShuaibi. October 25, 2014

Modeling Cumulative LID Features for Floodplain Impacts in an Urban Watershed in Houston, TX

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

Gloucester County PLAN SUBMITTER'S CHECKLIST

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

Landscape Design, Construction and Maintenance 2009

Figure 1 Cypress Street Study Area Location Map

Shelbyville, KY Stormwater Best Management Practices. Section 2 EROSION PREVENTION AND SEDIMENT CONTROL PLAN


Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil

Figure 1: Overview of CO 2 evaporator types

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Thermal Properties and Temperature

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

REQUEST FOR QUALIFICATIONS

STORMWATER REPORT FOR WALMART SUPERCENTER STORE # SIOUX FALLS, LINCOLN COUNTY, SOUTH DAKOTA BFA PROJECT NO

Performance Study of Triple Concentric Pipe Heat Exchanger

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

Dedicated Closed Circuit Hydrostatic Fan Drive Control

Lower Don River West Remedial Flood Protection Project TABLE OF CONTENTS. Page. Executive Summary

ST. MARY S SOIL CONSERVATION DISTRICT (SMSCD) AND DPW&T CONCEPT EROSION AND SEDIMENT CONTROL AND STORMWATER MANAGEMENT GUIDELINES AND CHECKLIST

MASTER DEVELOPMENT DRAINAGE PLAN FOR MONUMENT HEIGHTS

BRISBANE BAYLANDS INFRASTRUCTURE PLAN FEBRUARY 2011 APPENDIX O DRAFT

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

SBS5311 HVACR II Experiment 2: Analysis of the Combined Rankine and Vapour Compression Cycle

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Stock Vessels for Improved Quality and Energy Savings

Study on the Effect of Blade Angle on the Performance of a Small Cooling Tower

14 Drying. I Basic relations and definitions. Oldřich Holeček, Martin Kohout

TEXAS CHAPTER AMERICAN SOCIETY OF LANDSCAPE ARCHITECTS 2019 PROFESSIONAL AWARDS GUIDELINES

QATAR STANDARD QS SASO 2692/201 QS SASO 2692 ENERGY LABELLING REQUIREMENTS OF HOUSEHOLD ELECTRICAL CLOTHES WASHING MACHINES

Electric radiator tests

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

STAFFORD TRACT NORTH OF US90A 1.0 INTRODUCTION 1.1 OBJECTIVE

CHAM Case Study Numerical Simulation of a Air-to-air Cross-flow Heat Exchanger

2 A e ( I ( ω t k r)

HVACR Hydronic & Steam Systems

armfield COMPUTER CONTROLLED HEAT EXCHANGER SERVICE MODULE HT30XC series issue 2

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

INVITATION TO QUOTE. Page 1 of 7. Fire & Emergency Safety Plan Control Number: 2018-CFS-003 Issue Date: March 7, Purpose

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Checklists. Project Name: Location: File Number: Date of Submittal: Reviewer: Date: Applicant: Contact Name: Phone Number:

Three Rivers Park District Administration Center Rain Garden

Project Name: Project Address or Location: Principal Designer Name and Company: Principal Designer Phone Number:

Natural Ventilation A Green Smoke Control Approach

THE EFFECT OF HIGH TEMPERATURE AIR DRYING ON EVAPORATION, RUNNABILITY AND COATED PAPER PROPERTIES. Pertti Heikkilä and Pasi Rajala

GUILDFORD BOROUGH GREEN BELT AND COUNTRYSIDE STUDY

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

BLACK/HARMONY/FAREWELL CREEK WATERSHED EXISTING CONDITIONS REPORT CHAPTER 5 IMPERVIOUS SURFACES

This document is a preview generated by EVS

Chapter 1 Introduction

Appendix K. Stormwater Management Plan

Exhaust. a) For an arbitrary ambient temperature develop an expression for Q chiller in terms of M amb and M total.

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

Severn River Sub-Watershed: BMP 09-Retrofit

The Current (2017) State of the Art for Air Leakage in Ductwork

South Bismarck Watershed Model Update and Stormwater Improvement Project

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:

Transcription:

CEE:3371 Principles of Hydraulics and Hydrology Project #2 Flow Measurement with a Weir Problem Statement The Iowa DNR plans to monitor a proposed prairie restoration project in eastern Iowa as an experiment. The site is currently in row crops, and will be returned to a tallgrass prairie landscape in a few years. A small ephemeral stream drains the site. The Iowa DNR wishes to find out how the runoff from the site changes over time. You have been hired as a consultant on the project. Project Objective Design a weir flow control structure to continuously measure discharge at the site. Site Information The site for the flow measurement weir, and the representative channel cross-section at the site, are shown below: 2.5 Stream profile and cross-section A photograph of the stream at the proposed weir site is shown on the following page. Design Criteria Although the flow in the stream is usually contained within the streambanks, during times of high flow, the water will spread over the floodplain. The highwater mark for the largest observed flood is shown above. The Iowa DNR requires that the weir be able to measure flows as large as the largest observed flood. In addition, the DNR would like to know the extent of ponded water behind - 1 -

the weir (e.g., the water surface profile) for this design flood. Photograph showing the stream near the proposed weir site. A Global Water Instrumentation Inc. WL 400 Water Level Sensor will be used to measure water levels upstream of the weir site. The Iowa DNR requires that estimates of the uncertainty (ΔQ) of the discharge measurements be made for conditions of (1) bankfull flow and (2) the design flood. Weir Options One of two weir geometries may be selected for the site. One is a rectangular sharp-crested weir. The other is a V-notch sharp-crested weir. The two weirs have been delivered to the IIHR laboratory facilities for testing. Your project team will run tests to determine the weir head-discharge relation (Q = kh n ). Details of the experimental methods to be used to test the weirs are available in the attached appendix. Project Report Your project team must submit a final project report to the Iowa DNR Restoration Project Director. The report should be concise and focused on answering the project objectives. Minimum required components are: The recommended weir geometry and head-discharge relationship. Profile and cross-section specs for the weir site (sketch). This should include the height of the weir (H w ) above the stream bed, the maximum height of the weir, and the proposed placement of the water level sensor [Note: The construction manager will be directed to build to these specs]. The required water level measurement range (e.g., 0 to? feet) for the water level sensor (in - 2 -

order to purchase the correct WL400 Water Level Sensor). The estimated uncertainty (ΔQ) of the discharge measurement (in cfs) for the two cases mentioned in the Design Criteria. [Note: This will depend on the uncertainty (or accuracy) of the water level measurement (ΔH), as reported in the manufacturer s specifications for the water level sensor]. An estimate of the extent of ponded water behind the weir for the design flood condition [Note: A plot of the water surface profile calculation based the direct-step method would provide this information]. Any other recommended design and operation considerations for the site. The report should also contain technical information necessary to support your recommendations and conclusion; however, this information needs to be written at a level appropriate to the audience (i.e., the Project Director, who has an MS in Biological Sciences). Consultation with the CTC is not required, but is recommended (and will be rewarded with extra credit). Report Format (See appendix B) - 3 -

APPENDIX A WEIR CALIBRATION Principle The discharge over a weir is a function of the weir geometry and of the head on the weir. Introduction A weir is an obstruction in an open channel over which liquid flows. The purpose of this calibration is to determine the head-discharge relationship of two different shapes of weirs, and to compare the experimental results with their corresponding analytical expressions. Consider a weir with an irregular cross-section, as shown in Figure 1. Figure 1. Definition sketch for a weir Applying Bernoulli s equation along a streamline between a point upstream of the weir (where the velocity head is neglected) and a point in the plane of the weir, the velocity, V, at the weir is: where g is the gravitational acceleration and h is the elevation of the streamline below the free surface. Assuming that the velocity is constant throughout the (1) - 4 -

cross-section of the weir, the expression for the discharge, Q, over the weir becomes: (2) where A is the cross-section of the weir and b(h) is the width of the weir at elevation, h. Thus, the general expression for the weir head-discharge relationship is: (3) where k is a flow coefficient and n is an exponent. Both k and n are dependent on the shape of the weir (e.g., rectangular, triangular, trapezoidal or parabolic) and the flow conditions (velocity distribution in the approach section, fluid viscosity, surface-tension effects, and the contraction coefficient). Apparatus The experiment is conducted in 2-foot open channel flume facility located in the Seamans Center. The weir shapes subjected to measurements in this experiment are rectangular and triangular. The geometry of these weirs is sketched in the Figure 2. The weir shapes are cut from stainless steel sheets and can be considered as being sharp-edged. Figure 2. Geometry for typical weirs The water in the flume is recirculated using a pump. The flume entrance is conditioned with baffles and screens to ensure smooth entry of water in the flume. Slots in the sidewalls are located in the middle section of the flume, between which the weir plates can be inserted. The slope of the flume is such that no submergence of the weir occurs. Water is returned to the headbox through a pipe. A magnetic induction flowmeter is used to measure the flow entering the flume. The flow can be read via a meter on the wall or using the computer. A point gauge attached to the flume is provided to enable measurement of the head on the weir. The weir reference point is measured when the flume is empty and the weir plate is in place. The tip of the point gauge has to be lowered so that it is at the same level with the weir reference - 5 -

point. Subsequently, when the desired steady discharge is established in the flume, the point gauge is set so that it slightly touches the water surface, upstream of the weir. Subtracting the reference point elevation from that of the water-surface upstream the weir, the head on the weir (in feet of water) is obtained. Procedures The experiment involves setting the pump to produce a series of different discharges (at least five for each weir shape). Set the discharges approximately by setting the pump speed to values suggested by the TA. Using the head measured on the weir and the corresponding discharge measured by the flowmeter, a head-discharge relationship is determined and subsequently compared with the derived analytical expression. The coefficient of discharge for each weir is determined by comparing the theoretical and measured results. Proceed with the following sequence: 1. Insert the weir of the desired shape in the slots. 2. Read the reference point of the weir. 3. Set the pump speed on the pump motor controller to the desired value to obtain a given discharge in the flume. First, read the flow rate, Q, through the flume. 4. Read the point gauge set on the water surface upstream of the weir. 5. Repeat steps 2-4 four each of the three weir shapes. Measurements Following the procedures described above, measure the quantities specified in the following table: Discharge Rectangular Discharge Triangular 90E Q (cfs) Ref Pt (ft) W.S. Elev. (ft) Weir Head (ft) Q (cfs) Ref Pt (ft) W.S. Elev. (ft) Weir Head (ft) - 6 -

Data Analysis 1. Plot log Q vs. log H. From the best-fit line to the experimental points determine the n exp (i.e., the slope of the best-fit line) and k exp (i.e., the intercept of the best-fit line with the ordinate). 2. Compare the experimental (n exp ) and analytical (n t ) values of the exponent, n. 3. Compare k exp with values indicated in the literature. Further Considerations 1. Derive, analytically, the head-discharge relationship for each of the weir shapes given in Figure 2. The analytical head-discharge relationship for the rectangular and the triangular weirs are given in standard textbooks. 2. If data seem to imply, n exp n t, why this difference? References Gupta, R. S. (1989). Hydrology and Hydraulic Systems, Waveland Press, NY Hwang, N.H. and Houghtalen, R.J. (1996). Fundamentals of Hydraulic Engineering Systems, 3rd edition, Prentice Hall, NJ Rouse, H. (1967). Engineering Hydraulics, 6th Edition, John Wiley and Sons, NY - 7 -

APPENDIX B Report Format Section 1: Title Page - Course name - Title for the report - Submitted to Your clients - Your names - Your affiliation (lab section, group number) - Date Section 2: Executive Summary - A brief, concise paragraph summarizes your project within 200 words. - At the end of the summary, clearly state your recommendations to your clients. Section 3: Introduction - Statement of the problem - Project objectives Section 4: Background Information - Background information for the project including site and operational information etc. Section 5: Methodology (or Approach) - Describe and justify the methodology (or approach) you used to achieve the goals. Section 6: Results and Discussion - Present the results from the work. - Discuss the possible factors that may affect the outcomes. - Justify your suggestions. Section 7: Conclusions and Recommendations - Restate the scope of the work and how the objectives were achieved. - Summarize the major results from the work. - Provide your recommendations to your clients. Section 8: Appendices - This is the only part in the report that is written to professionals in case that second opinion needs to be consulted. Therefore, it needs to be prepared in a scientific manner. - Attach your technical analysis including: * Table or plot of raw data with units and caption (as appropriate). * Explain procedures for computed derived data. * Table or plot of derived data with units and caption (as appropriate). Note: 1. The main report needs to be written at a level appropriate to the audience. 2. If tables and figures are included in the report, proper numbering and captions are required. Figures should follow conventional scientific presentation; axes should be properly labeled; variable s name and unit should be specified. If multiple curves are plotted in the same figure, different symbols and line patterns should be used; legend should be shown. - 8 -