Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Similar documents
Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 2800PPM. Merlin CO2 Monitor 2800ppm. American Gas Safety LLC 1

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Merlin Gas Detectors. Rev: 09 Date: Product Data Sheet

Gas Safety Products. Installation, operating and maintenance. Merlin 1000BH Gas Proving/Gas Detection System

Gas Safety Products. Installation, operating and maintenance. Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Read these instructions carefully before operating or servicing.

Gas Safety Products. Installation, operating and maintenance 23/08/2016. Merlin 1000BH Gas Proving/Gas Detection System

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

Gas Safety Products. Installation, operating and maintenance 28/10/2015. Merlin CT1250 Gas Interlock System. S&S Northern Ltd 1

Troubleshooting Guide

Troubleshooting Guide

Gas Safety Products. Installation, operating and maintenance 11/26/2015. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

Gas Safety Products. Installation, operating and maintenance 10/12/2017. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

User's Guide. CO 2 Monitor. Model CO200

INSTALLATION AND OPERATING INSTRUCTIONS

WRF04 CO2. Application. Types Available. Security Advice Caution. Combined room sensor CO 2 / temperature / humidity. Datasheet

EXAMPLES OF HOW TO ORDER

EXAMPLES OF HOW TO ORDER

SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG

MERLIN RANGE KITCHEN EQUIPMENT CT1200S CT1250

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

WRF04 CO 2 RS485 Modbus

Centro-Matic Automated Lubrication Systems System Controls

BX444-Mc Gas Detector

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

ANALOX 3000 Carbon Monoxide Monitor

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

esense CO2 Transmitter and Alarm

C7232A,B Sensor and Controller

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

Power Supply Display Module PSDM. Installation and Operation Manual

KANE-ALERT-CO 2 Monitor with Temperature

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

APPLICATION DATA SHEET

OPERATING INSTRUCTIONS AND REPLACEMENT PARTS

Remote Storage Safety 3 Alarm Installation Guide

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

MERLIN RANGE GAS DETECTION EQUIPMENT

APPLICATION DATA SHEET

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

CMT MANUAL 6. NMC SENSORS

GS100M Gas Detection Controller

Multifunction IAQ Monitor

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

The product can be worked together with our wireless controller to control a ventilator, air cleaning device, or

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

VALTRONICS IAQ Monitor

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

Allure EC-Smart-Air Series Communicating sensors

02/11/2015

Lamp Supply (Recommended)

ACCURATE ELECTRONICS INC

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

Allure EC-Smart-Vue Sensor Series Line of communicating sensors with backlit display and graphical menus

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

GAS MONITOR Model Model

Installation Manual. esense Duct (Disp) Figure 1 The esense Duct with and without display

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

APPLICATION DATA SHEET

IGD.CO.UK

Zareba Metro Gas Detector

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Networkable Fan Coil Controller Specification and Installation Instructions

Flostop TS D7E and A8E. Operation Manual

TPI Corporation P.O. BOX 4973 JOHNSON CITY, TN

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Flopurge TS. Operation Manual

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

ALARMLINE ANALOGUE Linear Heat Detection System

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Model D12-IR. Digital Gas Transmitter...

Datasheet: K-22 LO Sensor

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Dräger Polytron 5720 IR Toxic Gas Detection

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

QPM21 Series Duct CO 2 and Air Quality Sensors

Room air quality sensors

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Generator Gas Analyzer (GGA)

Instruction Manual Model A

Transcription:

Gas Safety Products 4500PPM Installation, operating and maintenance Read these instructions carefully before operating or servicing Rev: 11 Date: 09-07-18 1

* The unit should be installed by a competent person only * * The expected life time of the detector/sensor element is more than 5 years * * The unit should be stored in cool, dry conditions * * We do recommend that this product is serviced annually * * If the unit is found to be damaged Contact us * * CALIBRATION * During the first 24 hours of installation, the unit will continue to adjust its calibration to the ambient CO2. During this time, you may notice slight variations in the PPM readings of CO2 displayed on the monitor. Table of contents 1 General information... 3 2 Installation... 3 2.1 Mounting the CO2 Sensor.... 3 2.2 Mains Supply... 3 2.3 Alarm Relay... 3 2.4 Pre Alarm Relay.... 3 2.5 Temperature Relay.... 3 2.6 0-10 Volt DC Output.... 3 2.7 Audible Alarm.... 3 3 Operation Instructions... 4 3.1 How to turn the system on and off... 4 3.2 Explanation of LED status... 4 3.2.1 Low (Green) LED... 4 3.2.2 Medium (Amber) LED... 4 3.2.3 High (Red) LED... 4 Merlin CO2 Wiring Diagram... 4 Rev: 11 Date: 09-07-18 2

1 General information The has a LED display to show the user a clear and precise reading of the CO2 level in the room also the traffic light colour system indicates the air quality in the area. The can be used independently or can work in conjunction with one of our Merlin gas control systems. If the CO2 reaches alarm level the would sound an audible alarm to alert the user and also send a signal to the Merlin gas control system which will in turn close the gas solenoid valve. 2 Installation 2.1 Mounting the CO2 Sensor The control panel is designed for surface mounting using two mounting screws. Removing the back plate gives access to the circuit board. Do not attempt to remove the PCB. 2.2 Mains Supply A 230-volt electrical supply should be supplied to the panel. This should be externally fused at 3 Amps using a fused spur and should be connected to the terminals marked LN Power. 2.3 Alarm Relay This will switch over should the level of Co2 rise above 4500ppm, and automatically switch back once the levels have dropped below 4450ppm. 2.4 Pre Alarm Relay This will switch over should the level of Co2 rise above 2800ppm, and automatically switch back once the levels have dropped below 2750ppm. 2.5 Temperature Relay This will switch over should the sensor detect the temperature rise above 30 C, and switch back once the temp drops back below 29 C etc. 2.6 0-10 Volt DC Output The voltage will increase / decrease depending on the ppm read out of Co2 detected. ANALOGUE OUTPUT 0-500ppm 2V 500-750ppm 3V 750-1000ppm 4V 1000-1250ppm 5V 1250-1500ppm 6V 1500-1750ppm 7V 1750-2000ppm 8V 2000-2400ppm 9V 2400-2800ppm 10V 2.7 Audible Alarm There is a dip switch on the circuit board to activate or de-activate the in-built audible alarm. (On = on & 1 = Off). This will sound at 2800ppm if enabled. Note: all low voltage connections should be made using a screened cable to avoid electrical interference. Rev: 11 Date: 09-07-18 3

3 Operation Instructions 3.1 How to turn the system on and off 1. To turn on the Merlin CO2 monitor you need to supply 230V into the L & N POWER terminal, this will then illuminate the blue LCD screen and initiate a 60 second countdown. When the countdown is complete the LCD screen will show CO2 levels in the room. 2. To turn off the Merlin CO2 monitor you need to turn the power supply to the panel off or disconnect the fuse spur. 3.2 Explanation of LED status Low (Green) LED Green - Good air quality, CO2 <1000ppm Medium (Amber) LED Yellow - Moderate air quality, 1000ppm> CO2 <2800ppm High (Red) LED Red - Poor air quality CO2 >2800ppm Merlin CO2 Wiring Diagram 1. Mains Input 230V, L & N 2. Alarm relay, volt free connection to Merlin system. 3. Pre alarm relay, volt free connection to Merlin system. 4. Temperature relay. 5. 0-10V output, low voltage connection. 6. Audible alarm switch, ON = ON / 1 = OFF Please note, Mains wires and low voltage wires should not be run in the same conduit as per the LOW VOLTAGE DIRECTIVE Rev: 11 Date: 09-07-18 4

Specification Power Supply Gas Sensor CO2 Measuring Range Accuracy @ 25 C (77 F) Temperature Measuring Range Temperature Accuracy Warm-up time at Switch On Switch Over Relay Output 230VAC, 50Hz (Max. 2VA) Carbon Dioxide: Non-Dispersive Infrared Detector (NDIR) ABC Logic Self Calibration 0-9999ppm (Resolution: 1ppm) ±100ppm +6% Reading 0-50 C (Resolution: 0.5 C) ±1 C 1 Minute 240VAC 1A, 30VDC 2A switching current (Resistive load) INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL & ELECTRONIC EQUIPMENT When this product has reached the end of its life it must be treated as Waste Electrical & Electronics Equipment (WEEE). Any WEEE marked products must not be mixed with general household waste, but kept separate for the treatment, recovery and recycling of the materials used. Please contact your supplier or local authority for details of recycling schemes in your area. CONTACT US: S&S Northern Head Office Tel: +44(0) 1257 470 983 Fax: +44(0) 1257 471 937 www.snsnorthern.com info@snsnorthern.com South East Division Tel: +44(0) 1702 291 725 Fax: +44(0) 1702 299 148 south@snsnorthern.com S&S Northern is the owner of this document and reserves all rights of modification without prior notice. Rev: 11 Date: 09-07-18 5