Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 2800PPM. Merlin CO2 Monitor 2800ppm. American Gas Safety LLC 1

Similar documents
Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Gas Safety Products. Installation, operating and maintenance 11/26/2015. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

Gas Safety Products. Installation, operating and maintenance 10/12/2017. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

Gas Safety Products. Installation, operating and maintenance 23/08/2016. Merlin 1000BH Gas Proving/Gas Detection System

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

Gas Safety Products. Installation, operating and maintenance. Merlin 1000BH Gas Proving/Gas Detection System

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

Gas Safety Products. Installation, operating and maintenance 28/10/2015. Merlin CT1250 Gas Interlock System. S&S Northern Ltd 1

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

Gas Safety Products. Installation, operating and maintenance. Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Read these instructions carefully before operating or servicing.

Troubleshooting Guide

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Merlin Gas Detectors. Rev: 09 Date: Product Data Sheet

Troubleshooting Guide

BX444-Mc Gas Detector

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

Centro-Matic Automated Lubrication Systems System Controls

WM3000 WIRELESS MODULES

How to use the BTRM in Remote Enclosures

SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG

INSTALLATION AND OPERATING INSTRUCTIONS

GS100M Gas Detection Controller

ESRTD2 Electronic Room Thermostat, with LCD Display

TPI Corporation P.O. BOX 4973 JOHNSON CITY, TN

OPERATING INSTRUCTIONS AND REPLACEMENT PARTS

EXAMPLES OF HOW TO ORDER

EXAMPLES OF HOW TO ORDER

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FA-300 Series. LED Fire Alarm Control Panel. User Guide. FA-300 SERIES Fire Alarm Control Panel. FA-300 SERIES Fire Alarm Control Panel

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

Added password for IP setup page : Password must be in IP format!

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

ACCURATE ELECTRONICS INC

SFC-200 SERIES LED FIRE ALARM PANEL

Networked Access Control Panel. Installation Guide

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

Multi Channel Gas Detection System AGDS MC. The Home of Control & Automation in Ireland

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

D3000. Installation & Setup Guide

Fill Point, Level Gauges, and Control Range

INSTRUCTION MANUAL A131 High Level Audible Warning System

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

E/One Sentry Advisor

FTA200-A REMOTE ALARM PANEL

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

The Remote alarm Panel, TYPE RAPv2

EC Series Wall Unit Humidifier

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

Installation Instructions

Digital Electronic Thermostat With RF

MAX ARM. Heavy Duty Linear Actuator for Residential / Commercial use. Super quiet Solar ready Large diameter stainless steel output shaft

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

GS100M Gas Detector. Technical Specification

Four Channel Gas Detection System AGDS 4. The Home of Control & Automation in Ireland

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

PSN-1000 & PSN 1000(E) Installation Manual

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

DOMESTIC STEAM GENERATOR Installation Instructions

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

Intelligent Security & Fire Ltd

Power Supply Display Module PSDM. Installation and Operation Manual

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

GPPS-evo V3.3. Installation Instructions

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

LEAKSTOPPER 1 Single zone water leak detection system

Engineers manual. Pass Through machines P500 P500 A P500 AS P500 A WS P500 AS WS. A- AirBreak WS Water Softener. AS Dual Rinse Element

Touchpad controller User Manual installation operation

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Digital Electronic Thermostat With RF

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

Please read this sheet as it contains important information

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

100 Series Gas Ventilation Interlock System

SAPLING PREMIUM LARGE CLOCKS

SAPLING HEALTHCARE SOLUTIONS

Digital Room Thermostat

Use this Specification Template to develop a specification to be used for requesting a quote or defining a job work description.

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Rev B, 9/2/2009. Kodiak Chiller Overview

H&O DIE SUPPLY, INC SPR-2000-JR. Programmable Fluid Controller Interstate 20 Kennedale, TX 76060

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

Ductless Split Air Conditioner

Transcription:

Gas Safety Products Merlin CO2 Monitor 2800PPM Installation, operating and maintenance 05/10/2016 American Gas Safety LLC 1

Table of contents 1 General information... 3 2 Installation... 3 2.1 Mounting the CO2 Sensor.... 3 2.2 Mains Supply... 3 2.3 Alarm Relay... 3 2.4 Pre Alarm Relay.... 3 2.5 Temperature Relay.... 3 2.6 0-10 Volt DC Output.... 3 2.7 Audible Alarm.... 3 3 Operation Instructions... 3 3.1 How to turn the system on and off... 3 3.2 Explanation of LED status... 4 3.2.1 Low (Green) LED... 4 3.2.2 Medium (Amber) LED... 4 3.2.3 High (Red) LED... 4 Merlin CO2 Wiring Diagram... 4 American Gas Safety LLC 2

1 General information The Merlin CO2 Monitor has a LED display to show the user a clear and precise reading of the CO2 level in the room also the traffic light colour system indicates the air quality in the area. The Merlin CO2 Monitor can be used independently or can work in conjunction with one of our Merlin gas control systems. If the CO2 reaches alarm level the Merlin CO2 Monitor would sound an audible alarm to alert the user and also send a signal to the Merlin gas control system which will in turn close the gas solenoid valve. 2 Installation 2.1 Mounting the CO2 Sensor. The control panel is designed for surface mounting using 2 mounting screws. Removing the back plate gives access to the circuit board. Do not attempt to remove the PCB. 2.2 Mains Supply. A 100-240volt electrical supply should be supplied to the panel. This should be externally fused at 3 Amps using a fused spur and should be connected to the terminals marked LN Power 2.3 Alarm Relay. This will switch over should the level of Co2 rise above 2800ppm, and automatically switch back once the levels have dropped below 2750ppm. 2.4 Pre Alarm Relay. This will switch over should the level of Co2 rise above 1500ppm, and automatically switch back once the levels have dropped below 1450ppm. 2.5 Temperature Relay. This will switch over should the sensor detect the temperature rise above 30 degrees celsius, and switch back once the temp drops back below 29 degrees celsius etc. 2.6 0-10 Volt DC Output. The voltage will increase / decrease depending on the ppm read out of Co2 detected. 2V per 1000ppm. 2.7 Audible Alarm. There is a dip switch on the circuit board to activate or de-activate the in-built audible alarm. (On = on & 1 = Off). This will sound at 1500ppm if enabled. Note: all low voltage connections should be made using a screened cable to avoid electrical interference. 3 Operation Instructions 3.1 How to turn the system on and off 1. To turn on the Merlin CO2 monitor you need to supply 100-240V into the L & N POWER terminal, this will then illuminate the blue LCD screen and initiate a 60 second countdown. When the countdown is complete the LCD screen will show the CO2 levels in the room. 2. To turn off the Merlin CO2 monitor you need to turn the power supply to the panel off or disconnect the fuse spur. American Gas Safety LLC 3

3.2 Explanation of LED status 3.2.1 Low (Green) LED Green - Good air quality, CO2 <1000ppm 3.2.2 Medium (Amber) LED Yellow - Moderate air quality, 1000ppm> CO2 < 1500ppm 3.2.3 High (Red) LED Red - Poor air quality CO2 >1500ppm Merlin CO2 Wiring Diagram 1. Mains Input 100-240V, L & N 2. Alarm relay, volt free connection to Merlin system. 3. Pre alarm relay, volt free connection to Merlin system. 4. Temperature relay. 5. 0-10V output, low voltage connection. 6. Audible alarm switch, ON = ON / 1 = OFF Please note, Mains wires and low voltage wires should not be run in the same conduit as per the LOW VOLTAGE DIRECTIVE American Gas Safety LLC 4

CONTACT US: AGS Head Office Tel: (727) 608-4375 Fax: (727) 538-4237 info@americangassafety.com Rev Date Author Description 01 05.10.16 American Gas Safety BT Merlin CO2 2800 First issue American Gas Safety is the owner of this document and reserves all rights of modification without prior notice. American Gas Safety LLC 5