Firefighting units constructed in compliance with UNI EN and UNI standards

Similar documents
SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

INSTRUCTION MANUAL. PLASTIC MENDER mod. ITA

CFR1 05 I N S T R U C T I O N S MANUAL C F R : I N S T R U C T I O N S A N D M A I N T E N A N C E M A N U A L

CHATTANOOGA JUNIOR STAR

ULTRASONIC HUMIDIFIER UHF

ULTRASONIC HUMIDIFIER

USER S MANUAL. Rectifier 1 10 A/10 48 V for Kliar Line Art

HUMIDITY AND TEMPERATURE CONTROLLER

NRS1/NRS1-R RAIN SENSOR LOW TENSION HEATED RAIN SENSOR (R-RADIO VERSION) MANUAL FOR INSTALLATION AND USE. Symbols used in the manual.

STEAM BOX PRO USING INSTRUCTIONS ENGLISH

JET VAC COMPACT. Jet Vac Compact

Service station for A/C systems ECOS-150 Use and Instruction Manual

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

USER S MANUAL. 4 5-liters Tanks e- coating and galvanic Plant with Ultrasonic Art

PLATING DIVISION. LEGOR GROUP S.p.A. Via del Lavoro, Bressanvido (VI) Italy - tel fax

Data Booklet EN12845 BREN TYPE FIREFIGHTING BOOSTER SET. Brentas Ltd

Fire Pump Systems In Accordance With TS EN A2 Standard

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

Combi Modular System. Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610

Use and maintenance manual

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

Residential Fire Fighting Booster Systems

STAINLESS STEEL MULTISTAGE HORIZONTAL PUMPS SERIE ULTRA

FIRE-FIGHTING UNITS. 50 Hz. EBARA Pumps Europe S.p.A. Via Pacinotti, 32

MARINE. High efficiency pumps you can rely on

PART 1 - GENERAL 1.1 WORK INCLUDED

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

FULL RANGE EXPERTISE FIRE PUMPS FOR EVERY STANDARD

Instruction Manual Captive Air Level Control. Model NLP

AD.3.XG... Atex directive ch. I Page 22 Atex classification ch. I Page 23. Tab.1 Assembly ch. I Page 25

Industrial Pump Solutions

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

Rotary screw compressors

R557R EN January 2012

Systems for central heating

Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems

Pressurisation units & expansion vessels

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

1 of 68. Thong Fatt Jaya Machinery Hardware Sdn. Bhd. DOUBLE-STAGE LIQUID RING VACUUM PUMP. Air- Operated Double Diaphragm Pump TW Series

COMPANY PROFILE

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

MCV - MCH - MCHZ Multistage pumps

WET ALARM VALVE CPF FIRE V.A.U. 3 V.A.U. 4

3 PT HITCH MOUNTED SPRAYER DELTA FORCE

Australian Standard. Fixed fire protection installations Pumpset systems AS AS 2941

AGRICULTURAL MACHINERY FUNCTIONAL AND SAFETY TESTING SERVICE


1.1 This section applies to air handling units for HVAC Systems.

FORMULA. Rotary screw compressors. kw 5,5-7, , bar

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

VACOOK. Thermocirculator for Sous Vide cooking USE AND MAINTENANCE MANUAL

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

TECHNICAL DESCRIPTION

GALATEA DOMUS. Dal 1901 COD

High-expansion foam plant UNI EN 13565

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

SPRINKLER SYSTEM SOLUTIONS. Water-based Fire-Fighting Sprinkler System PROVEN TECHNOLOGY

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Heavy Duty Process Pumps API 610/ISO 13709

STAR 18 PELLET BOILER STOVE

geothermal march 2011

Conditioning your ambient, maximising your comfort.

Fire Protection Pumps

SECTION STEAM CONDENSATE PUMPS

NHS VERTICAL AGITATOR

Following are the systems proposed as per NBC & Local Fire Authority:

SAFETY/ SECURITY - FIRE FIGHTING INTEGRATED SYSTEMS

Ruhrpumpen Fire Systems

Air operated diaphragm pumps. Catalogue 2011 rev 1

PROJECT: NITESH PALO Bangalore FIRE SAFETY MEASURES

BUSINESS PLAN CEN/TC 197 PUMPS EXECUTIVE SUMMARY

1/2 NKV UNI EN FIRE-FIGHTING SETS WITH VERTICAL PUMPS TECHNICAL DATA TECHNICAL DATA

Instructions for Installer, Maintenance Engineer and final User

3PT HITCH MOUNTED MIST BLOWER AT LOW VOLUME

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

USING AND MAINTENANCE MANUAL FOR SELF-CONTAINED POWER BRUSH MACHINE FOR CARPET AND HARD FLOOR. Elite-Silent. Elite-Silent

Enclosure 4- RISK ASSESSMENT

These reasons speak for the pumps from Wacker Neuson. Pump expertise in detail. Overview of all pumps.

Oil burners fuel unit with solenoid valve

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

DABPUMPS.COM UNI EN FIRE-FIGHTING SETS

DOCUMENT TABLE OF CONTENTS

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

ECOPlus SERIES OF HIGH-PRESSURE METERING MACHINES

WIND Technical Description

Rotary screw compressors

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH


Oil burners fuel unit with solenoid valve

Industrial peristaltic pumps

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

Pellet Boilers. Instructions for Use and Maintenance

OENOLOGICAL ELECTROPUMPS

K4RH(X) Solids-Handling Pumps

CESI EXTENSION D. 02/12 ~ FGH ~ to EC-Type Examination Certificate CESI 03A TEX057X Equipment: Explosion proofsolenoid series OA-; OZA; MZA-A- Manufac

LC Series - Light Commercial Pump Station Installation and Operation Manual

Transcription:

FIREFIGHTING

CONTENTS Firefighting units constructed in compliance with UNI EN 12845 and UNI 10779 standards _02 Electric pump + jockey pump _06 2 Electric pumps + jockey pump _08 Combustion engine pump + jockey pump _10 Electric pump + combustion engine pump + jockey pump _12 Electric pump + submersible jockey pump _14 2 Electric pumps + submersible jockey pump _16 Compact firefighting system for hotels _18 Technical shelter in compliance with UNI 11292 _19 CE declaration of conformity _20 1

Firefighting units constructed in compliance with UNI EN 12845 and UNI 10779 standards Standard UNI EN 12845 concerns "Fixed firefighting systems - Automatic sprinkler systems - Design, installation and maintenance. This standard harmonises the execution of sprinkler based firefighting systems on a European level, establishing the method of construction of the fire pump systems that can be installed in Europe, serving sprinkler and/or hydrant firefighting networks. IDROBIOS operates in the design, production and worldwide distribution of products for the management of water, constantly developing new products in compliance with customer demands. All the systems manufactured are individually tested in compliance with the requirements of UNI EN 12845. IDROBIOS fire pumps are composed of one or more main pumps driven by an electric motor or internal combustion engine and equipped with a jockey pump that keeps the system constantly pressurised without starting the main pumps. Designed to operate automatically in the presence of water withdrawal demands from any service of the firefighting system, including: Sprinkler systems Hose reel systems Hydrant systems (UNI 45 / UNI 70) 2

Firefighting Operation The pumps start in response to a pressure drop in the firefighting circuit. The jockey pump is started first; if the jockey pump is unable to restore system pressure, the feed pump is started. The feed pump is started by two pressure switches via an electrical control panel; the feed pump must run continuously until it is stopped with a manual command to UNI EN 12845 par. 10.7.5.2; or, taking account of UNI10779 related to hydrant circuits, the pump can be stopped automatically by means of a timer installed in the control panel, with minimum time setting of 20 minutes. The two pump start pressure switches must be calibrated to comply with the following pressure values: Units with one electric pump - max pump pressure (x 0.8 bar) Units with two electric pumps - pump 1 max pressure (x 0.8 bar) - pump 2 max pressure (x 0.6 bar ) Example: max pressure 10 bar - pump 1 starts at 8 bar - - pump 2 starts at 6 bar - Starting of the main pump(s) is signalled by an acoustic/visual indicator; the indicator trips also in the event of a phase loss or power loss. The low flow rate jockey pump is an electric centrifugal pump, generally a self-priming type of low power, designed to maintain the system pressure and compensate for minor leakage from the firefighting circuit, thereby avoiding unnecessary starts of the main pump(s). The jockey pump is started automatically by a dedicated control panel and associated pressure switch set to a pressure value that is slightly higher than the main pump pressure switch. The jockey pump stops when system pressure is restored. 3

Firefighting units constructed in compliance with UNI EN 12845 and UNI 10779 standards IDROBIOS offers firefighting units fully assembled on a single skid, or divided into separate modules to facilitate transport and management of the installation spaces on the work site. The standard composition of firefighting units preassembled on a single skid includes: Standardised main pumps to EN733. Pressure switches (two for each electric pump/combustion engine pump). Glycerine-filled pressure gauges. Water circulation connection for pump protection. Check valve on main pump outlet for connection of a priming tank, if required (for suction lift installation). Double-flanged outlet manifold in painted steel. Batteries for starting the diesel engine pump, if present. Fuel tank constructed in compliance with EN 12845, complete with standard flexible connections, with combustion engine pump. Electrical panel in metal enclosure in compliance with EN 12845 for control of the main electric pump. Electrical panel in metal enclosure in compliance with EN 12845 for control of the main combustion engine pump. Electrical panel for jockey pump control. Steel skid complete with deck for electric pumps, combustion engine pump (if present), for electrical control panels and for batteries (if present). Membrane expansion vessels, capacity 20l. The electrical panels installed on firefighting units comply with the following specifications, required by EN 12845: For surface pumps direct starting for power ratings up to 10 HP star-delta starting for power ratings 12.5 HP For submersible pumps: direct starting for power ratings up to 10 HP stator resistance starter for power ratings 12.5 HP 4

Firefighting Eccentric flanged reductions to install on the suction connections of the main pumps. Direct reading flow meter For accurate reading of the flow rate shown on the flow meter, interpose two sections of pipe having a length that is 5 times the diameter (DNA) of the pipe upstream and downstream of the flow meter. Wafer type butterfly shut-off valve. Local alarm panel for remotable visual - acoustic alarms. Clapet check valve installed on the pumps outlet line. 100 l priming tank (for LH risk class) and 500 l for OH, HHP and HHS. Antivibration flexible compensators If the system includes a combustion engine pump it will include a flexible compensator to dampen vibrations. Water/water cooling circuit with heat exchanger, available on request. The system draws the necessary volume of water to cool the engine directly from the main pump; take account of this flow rate and exclude it from the calculation for firefighting duties (to select the fire pump correctly add the design flow rate to the flow required by the heat exchanger). The configuration of the cooling system with water/water heat exchanger includes a by-pass circuit complete with shut-off valves, pressure reducers, pressure gauge, and "Y" filters. 5

Electric pump + jockey pump Single-stage centrifugal main pumps with standardised bare shaft of the back pull-out type, constructed in compliance with EN 733 (ex DIN 24255). Connection with asynchronous three-phase electric motor made by means of a flexible spacer coupling. The firefighting unit is complete with a main electric pump mounted on a skid made of painted steel profiles, wired to the electrical control panel installed on the skid vertical frame. The supply of the IDROBIOS firefighting unit includes the following components on the suction line: shut-off valve and eccentric reduction mounted on the suction side of the main electric pump. Flow rates up to 420 m 3 /h and maximum pressure head of 97 m w.g. Maximum speed of 2900 rpm. For higher flow rates and pressure heads consult our engineering department. 6

Firefighting Main components (5) (5) (5) (12) (6) (4) (4) (3) DNM (22) (20) (17) (19) (18) (9) (7) (7) (19) (16) (1) (2) (15) (11) (14) (10) DNA1 (Suction) DNA2 (13) (21) Key: (01) Main electric pump (02) Electric jockey pump (03) Outlet manifold (04) Flow meter kit (05) Pressure tank (06) Pressure gauge (07) Inspectable check valve (08) Priming kit - for suction lift installation (09) Pressure switches (no.2 for each of the main electric pumps) (10) Eccentric reduction with vacuum meter (11) Spacer coupling for pump/motor connection (12) Electrical control panels (13) Skid/motor coupling with anti-vibration joint (14) Standardised pump with bare shaft to EN 733 (15) Three-phase asynchronous motor (16) Glycerine filled pressure gauge with isolator cock (17) Wafer type shut-off valve (18) Ball valve to isolate flow meter circuit (19) Flow meter circuit with return to storage (20) Electric jockey pump pressure switch (21) Frame/Skid (22) Omega profile for cable routing 7

2 Electric pumps + jockey pump Single-stage centrifugal main pumps with standardised bare shaft of the back pull-out type, constructed in compliance with EN 733 (ex DIN 24255). Connection with asynchronous three-phase electric motor made by means of a flexible spacer coupling. The firefighting unit is complete with two main electric pumps mounted on a skid made of painted steel profiles, wired to the electrical control panels installed on the skid vertical frame. The supply of the IDROBIOS firefighting unit includes the following components on the suction line: shut-off valve and eccentric reduction mounted on the suction side of the main electric pumps. Flow rates up to 420 m 3 /h and maximum pressure head of 97 m w.g. (data referred to single pump) For higher flow rates and pressure heads consult our engineering department. 8

Firefighting Main components (5) (5) (5) (5) (12) (6) (3) DNM (4) (4) (20) (17) (22) (19) (18) (9) (7) (7) (7) (19) (16) (1) (1) (2) (15) (11) (14) (10) (Suction) DNA1=DNA2 (Suction) DNA3 (Suction) DNA1=DNA2 (13) (21) Key: (01) Main electric pump (02) Electric jockey pump (03) Outlet manifold (04) Flow meter kit (05) Pressure tank (06) Pressure gauge (07) Inspectable check valve (08) Priming kit - for suction lift installation (09) Pressure switches (no.2 for each of the main electric pumps) (10) Eccentric reduction with vacuum meter (11) Spacer coupling for pump/motor connection (12) Electrical control panels (13) Skid/motor coupling with anti-vibration joint (14) Standardised pump with bare shaft to EN 733 (15) Three-phase asynchronous motor (16) Glycerine filled pressure gauge with isolator cock (17) Wafer type shut-off valve (18) Ball valve to isolate flow meter circuit (19) Flow meter circuit with return to storage (20) Electric jockey pump pressure switch (21) Frame/Skid (22) Omega profile for cable routing 9

Combustion engine pump + jockey pump Single-stage centrifugal main pumps with standardised bare shaft of the back pull-out type, constructed in compliance with EN 733 (ex DIN 24255). Connection with internal combustion engine (diesel) made by means of a flexible spacer coupling. The firefighting unit is complete with a combustion engine pump mounted on a skid made of painted steel profiles, wired to the electrical control panel installed on the skid vertical frame. The supply of the IDROBIOS firefighting unit includes the following components on the suction line: shut-off valve, eccentric reduction, and rubber anti-vibration joint, mounted on the suction side of the main combustion engine pump. Flow rates up to 420 m 3 /h and maximum pressure head of 97 m w.g. Maximum speed of 2900 rpm For higher flow rates and pressure heads consult our engineering department. 10

Firefighting Main components (5) (5) (6) (12) (2 ) (4) (4) (3) (23) (23) (19) (20) (17) (15) (9) (18) (7) (7) (19) (2) (16) (1) (24) (11) (14) (22 ) (10) (13) (21) DNA DNA2 Key: (01) Combustion engine pump (02) Electric jockey pump (2 ) Fuel tank (03) Outlet manifold (04) Flow meter kit (05) Pressure tank (06) Pressure gauge (07) Inspectable check valve (08) Priming kit - for suction lift installation (09) Pressure switches (no.2 per combustion engine pump) (10) Eccentric reduction with vacuum meter (11) Spacer coupling for pump/motor connection (12) Electrical control panels (1 for combustion engine pump. 1 for jockey pump) (13) Skid/motor coupling with anti-vibration joint (14) Standardised pump with bare shaft to EN 733 (15) Internal combustion engine. (16) Glycerine filled pressure gauge with isolator cock (17) Wafer type shut-off valve (18) Ball valve to isolate flow meter circuit (19) Flow meter circuit with return to storage (20) Electric jockey pump pressure switch (21) Frame/Skid (22) Rubber anti-vibration joint 11

Electric pump + combustion engine pump + jockey pump Single-stage centrifugal main pumps with standardised bare shaft of the back pull-out type, constructed in compliance with EN 733 (ex DIN 24255). Connection with electric motor and internal combustion engine made by means of a flexible spacer coupling. The firefighting unit is complete with a main electric pump, a combustion engine pump and an electric jockey pump, mounted on a skid made of painted steel profiles, wired to the associated electrical control panels installed on the skid vertical frame. The supply of the IDROBIOS firefighting unit includes the following components on the suction line: shut-off valve, eccentric reduction, and rubber anti-vibration joint (for combustion engine pump), mounted on the suction side of the main pumps. Flow rates up to 420 m 3 /h and maximum pressure head of 97 m w.g. Maximum speed of 2900 rpm. For higher flow rates and pressure heads consult our engineering department. 12

Firefighting Main components (5) (5) (5) (12) (6) (4) (12) (25) (4) (3) (23) (23) (19) (22 ) (20) (17) (7) (15 ) (18) (9) (7) (7) (7) (2) (1) (1 ) (24) (15) (11) (16) (14) (23) (10) DNA1 (21) (13) DNA3 DNA2 Key: (01) Main electric pump (01 ) Combustion engine pump (02) Electric jockey pump (03) Outlet manifold (04) Flow meter kit (05) Pressure tank (06) Pressure gauge (07) Inspectable check valve (08) Priming kit - for suction lift installation (09) Pressure switches (no.2 for each of the main electric pumps) (10) Eccentric reduction with vacuum meter (11) Spacer coupling for pump/engine connection (12) Electrical control panels (13) Skid/motor coupling with anti-vibration joint (14) Standardised pump with bare shaft to EN 733 (15) Three-phase asynchronous motor (15') Internal combustion engine (16) Glycerine filled pressure gauge with isolator cock (17) Wafer type shut-off valve (18) Ball valve to isolate flow meter circuit (19) Flow meter circuit with return to storage (20) Electric jockey pump pressure switch (21) Frame/Skid (22) Omega profile for unit connection cables (23)Rubber anti-vibration joint (combustion engine pump suction) (24) Batteries (25) Fuel tank 13

Electric pump + submersible jockey pump Submersible type main pump with asynchronous three-phase electric motor. The firefighting unit is complete with a main electric pump and a submersible electric jockey pump, supplied disconnected from the hydraulic control assembly. Together with the electrical control panels, this latter is mounted on a skid made of painted steel profiles. Supply of the IDROBIOS firefighting unit includes the components listed below complete with a main electric pump and jockey pump (supplied separately - installation to be carried out by the customer). Flow rates of up to 90 m 3 /h and maximum pressure head of 136 m w.g. Maximum speed of 2900 rpm. For higher flow rates and pressure heads consult our engineering department. 14

Firefighting Main components Main electric pump control panel Jockey pump control panel (3) (3) (3) (7) (4) DNM (9) (6) (1) (9) (2) (6) (5) DNA2 (5) (2) DNA1 (10) (10) 5xDNA 5xDNA DNA Return to storage tank Submersible electric pump External jacket Key: DNA1 Main electric pump connection DNA2 Electric jockey pump connection (01) Outlet manifold (02) Wafer valve for connection of flow meter kit (03) Pressure tank (04) Pressure gauge (05) Inspectable check valve (06) Pressure switches (07) Electrical control panels (1 for main pump + 1 for jockey pump) (08) Wafer type shut-off valve (09) Pressure relief valve (10) Frame/Skid 15

2 Electric pumps + submersible jockey pump Submersible type main pumps with asynchronous three-phase electric motor. The firefighting unit is complete with two main electric pumps and a submersible electric jockey pump, supplied disconnected from the hydraulic control assembly. Together with the electrical control panels, this latter is mounted on a skid made of painted steel profiles. The IDROBIOS firefighting unit supply includes the following components complete with main and jockey electric pumps (supplied separately - installation to be performed by the customer). Flow rates of up to 90 m 3 /h and maximum pressure head of 136 m w.g. Maximum speed of 2900 rpm. For higher flow rates and pressure heads consult our engineering department. 16

Firefighting Main components Main electric pump 1 control panel Jockey pump control panel Main electric pump 2 control panel (3) (3) (7) (4) DNM (9) (6) (1) (9) (2) (2) (6) (6) (2) 2000 (5) DNA3 (5) (5) DNA1 DNA2 (10) (10) 5xDNA 5xDNA DNA Submersible electric pump External jacket Submersible electric pump External jacket Return to storage tank Key: DNA1 Main electric pump connection DNA2 Electric jockey pump connection (01) Outlet manifold (02) Wafer valve for connection of flow meter kit (03) Pressure tank (04) Pressure gauge (05) Inspectable check valve (06) Pressure switches (07) Electrical control panels (08) Wafer type shut-off valve (09) Pressure relief valve (10) Frame/Skid 17

Firefighting units with vertical axis pumps Electric, diesel and/or mixed type. Constructed in accordance with UNI EN 12845. Flow rates up to 1200 m 3 /h, Pressure head of up to 310 m w.g. Outlet manifold Flow meter Internal combustion engine Pump Head Electric Motor Head Distribution base Distribution base 0.00 Submersible electric jockey pump Submersible main vertical axis pump Suction rose Compact firefighting system for hotels Construction to UNI EN 12845 composed of 1 main electric pump + 1 electric jockey pump (both submersible type). Visual Acoustic ALARM Overload Power Lock On Mute Run M - 0 - A Door Lock Overload Trip Power On ELECTRIC JOCKEY PUMP CONTROL PANEL Run M - 0 - A Flow meter Door Lock Overload Trip Power On MAIN ELECTRIC PUMP CONTROL PANEL 18 The system is designed for hotels with up to 100 beds. The fire-protection water distribution activities for this type of building are governed by art. 11.3.1 of Italian ministerial decree 9 April 1994 and by Italian ministerial decree 6 October 2003. The former decree requires that: Hotels with a number of beds from 25 up to 100 must be equipped with DN 20 hose reels. The hose reels can be connected to the normal water mains on the condition it is able to feed the two hose reels in the most hydraulically unfavourable position in addition to the normal services, assuring for each of the foregoing hose reels a flow rate of at least 35 l/min at a minimum pressure of 1.5 bar, when both hoses are open. The water supply must assure water output for at least 60 min. If the water mains is unable to meet the foregoing condition the system shown alongside can be installed, comprising a water storage tank having total capacity of 2000 litres, two submersible electric pumps, one of which a jockey pump, control panels, alarm panel, and hydraulic assembly.

Firefighting Technical shelter in compliance with UNI 11292 UNI 11292 specifies the construction and functional requirements for technical shelters to accommodate firefighting pressurisation units. The indications in the standard complete the prescriptions of the legislation applicable to the subject and specifically EN 12845 (fixed firefighting systems Sprinkler systems), UNI 10779 (Hydrant circuits design, installation and operation) and UNI 10803 (Prefabricated stairs legislation). The latter is applicable only to underground systems. IDROBIOS offers prefabricated firefighting technical shelters with R60 structural resistance to fire; optionally also with integral or modular water storage, in both underground and above ground versions. Configuration of the standard system includes the installed firefighting unit, lighting, heating, a fire extinguisher and all the parts required by the reference standards to ensure conformity with the certifications issued by the company. 19

CE declaration of conformity All firefighting units described in the following catalogue are complete with a DECLARATION OF CONFORMITY Drafted in compliance with the requirements of the machinery directive 2009/127/EEC (ex 2006/42/EC) Each machine is supplied complete with the relevant technical documentation, namely: Operating and maintenance manual Name and address of the manufacturer Model DICHIARAZIONE Serial number DI CONFORMITA La Idrobios srl Year of construction DICHIARA DI CONFORMITA DICHIARAZIONE La Idrobios srl DICHIARAZIONE La Idrobios srl CHE IL GRUPPO DI PRESSURIZZAZIONE ANTINCENDIO Marca: Modello: Descrizione: IDROBIOS Es. gruppo antincendio costituito da una elettropompa principale, una Matricola: Anno costruzione: DDII CCONFORMITA H IAR Aed una elettropompa pilota. motopompa diesel CHE IL GRUPPO DI PRESSURIZZAZIONE ANTINCENDIO È stato realizzato in conformità alle direttive: Marca: Modello: Descrizione: IDROBIOS Direttiva macchine (2009/127/CEE) (Ex 98/37/CE Ex 2006/42/EC) Es. gruppo antincendio costituito da una elettropompa principale, una motopompa diesel ed una elettropompa pilota. Bassa tensione (2006/95/CE) (Ex 73/23/CEE Ex 93/68/CEE) Matricola: Anno costruzione: Compatibilità elettromagnetica (2004/108/CE) GRUPPO DI PRESSURIZZAZIONE ANTINCENDIO (Ex 89/336/CEE Ex 92/31/CEE Ex 93/68/CEE) È stato realizzato in conformità alle direttive: IDROBIOS nel rispetto delle vigenti: Direttiva macchine (2009/127/CEE) (Ex 98/37/CE Ex 2006/42/EC) antincendio costituito da una elettropompa principale, una Es. gruppo UNI EN 12845 Impianti fissi di estinzione incendi - Sistemi automatici DICHIARA CHE IL Marca: Modello: Descrizione: motopompa diesel ed una elettropompa pilota. Bassa tensione (2006/95/CE) (Ex 73/23/CEE Ex 93/68/CEE) UNI 10779 Impianti di estinzione incendi - Reti di Idranti Compatibilità elettromagnetica UNI EN(2004/108/CE) ISO 9906 Prove di prestazioni idrauliche pompe (Ex 89/336/CEE Ex 92/31/CEE Ex 93/68/CEE) È stato realizzato in conformità alle direttive: Matricola: Anno costruzione: nel rispetto delle vigenti: Dichiara inoltre che sono state applicate le seguenti Norme Armonizzate: Direttiva macchine (2009/127/CEE) (Ex 98/37/CE Ex 2006/42/EC) UNI EN ISO 12100-1 (Ex 292/1) UNI EN 12845 Impianti fissi di estinzione incendi - Sistemi automatici UNI EN ISO 12100-2 (Ex 292/2) Bassa tensione (2006/95/CE) CEI EN 60204-1 Sicurezza del macchinario, equipaggiamento elettrico delle macchine. Regole generali (Ex 73/23/CEE Ex 93/68/CEE) UNI 10779 Impianti di estinzione incendi - RetiBT. di Idranti CEI 17/13-1 Quadri Compatibilità elettromagnetica (2004/108/CE) Le Prove informazioni tecnicheidrauliche sono presso: UNI EN ISO 9906 di prestazioni pompe (Ex 89/336/CEE Ex 92/31/CEE Ex 93/68/CEE) Idrobios srl Via Sant Anna 612/B nel rispetto delle vigenti: Dichiara inoltre che sono state applicate le seguenti Norme Armonizzate: 41122 Modena UNI ISO 12100-1 (Ex 292/1) UNI EN 12845 Impianti fissien di estinzione incendi - Sistemi automatici Lì, CEI EN 60204-1 del macchinario, equipaggiamento elettrico delle macchine. Regole generali UNI 10779 Impianti di estinzione incendi - Sicurezza Reti di Idranti UNI EN ISO 12100-2 (Ex 292/2) CEI 17/13-1 Quadri BT. Firma (Lusvarghi Paolo) UNI EN ISO 9906 Prove di prestazioni idrauliche pompe Le informazioni tecniche sono presso: Idrobios srl Via Sant Anna 612/B Dichiara inoltre che sono state applicate le seguenti Norme Armonizzate: 41122 Modena UNI EN ISO 12100-1 (Ex 292/1) Firma Lì, UNI EN ISO 12100-2 (Ex 292/2) CEI EN 60204-1 Sicurezza del macchinario, equipaggiamento elettrico delle macchine. Regole generali CEI 17/13-1 Quadri BT. (Lusvarghi Paolo) Le informazioni tecniche sono presso: Idrobios srl Via Sant Anna 612/B 41122 Modena Lì, Firma (Lusvarghi Paolo) 20

Strada Sant Anna, 612/B 41122 Modena - Italy tel. +39 059 451 117 fax +39 059 451 210 VAT number and Tax Code 01824740367 info@idrobios.com - www.idrobios.com