Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Similar documents
PROFIRE -E SERIES BURNERS

MODEL CEW OHIO SPECIAL

Power Flame Incorporated

Section B1. Flexible Watertube Boilers TABLE OF CONTENTS

SC Series Forced Draft Burners

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Power Flame Incorporated

Power Flame Incorporated

NMC Nozzle Mix Gas/Oil Combination Burners

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

ECLIPSE INFORMATION GUIDE

Power Flame Incorporated CMAX. Installation and Operation Manual

mith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON

GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7. Model C Forced Draft Burners. Natural Gas or Propane MODEL C10

Type CG Series Forced Draft Gas Burner

INDITHERM. Low temperature gas burners

"HC" AIRFLO. In-duct firing line burner

Copyright 2009 Power Flame Incorporated

ECLIPSE INFORMATION GUIDE

product WM 30 oil, gas and dual fuel version Weishaupt monarch WM30 burners highly efficient and versatile

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

Eclipse AirHeat Burner

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

PBG PACKAGED GAS BURNER

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

Steam Fundamentals. (in heating & processing applications)

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

Eclipse AirHeat Burners

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

R-Series Oil Burners. Riello Burners a world of experience in every burner we sell. Reliable Combustion Solutions

Document code: 1 (10) Issuing date: Status:

Design and Application Details

Specifications of MULTIFIRE burners

SERIES 19A. mith PRESSURIZED WET BASE

Design Guide /12/2008. Eclipse RatioAir Burners RA Series Version 1

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Model CB-LE. Packaged Boiler HP. Operation, Service, and Parts Manual /09. and Model CB Ohio Special HP

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

Counterflo CF BASIC COUNTERFLO HEATER RCF CURB MOUNTED ROOFTOP HEATER CFDF COUNTERFLO DUCT FURNACE INDIRECT-FIRED INDUSTRIAL HEATERS

APX. Nozzle-mix line burner

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

Design Guide No /01. RatioMatic Burners. RM Series Version 3.10

Specifications of V-Line burners

PACKAGED COMMERCIAL WATERTUBE BOILERS

Installation Instructions

THE CORPORATION OF THE CITY OF LONDON. POTTERSBURG POLLUTION CONTROL PLANT FILTER BUILDING ODOUR CONTROL Tender No ADDENDUM NO.

JBFX/HDFX Series Forced Draft Burners

CEI Jacketed Firebox Heater Operation, Service & Parts Manual

OPERATING AND MAINTENANCE MANUAL

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

product WM 20 oil, gas and dual fuel version Weishaupt monarch WM20 burners compact and powerful Information on oil, gas and dual fuel burners

TUBE-O-THERM Low Temperature Gas Burners

Eclipse RatioMatic Burners

About Carlin. Visit our website, or call us at to learn more about this authentic Made-in-America company.

Design Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1

DELTA-TE III. Nozzle-mix line burner

STR-Series Indirect-Fired Air Turnover Units

5.0 ALARMS & TROUBLESHOOTING

ADF/ADFH 300 and 500

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

Equipment Specifications

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

LFL Series Burner Flame Safeguard Control

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

MODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

Distributed By: M&M Control Service, Inc Building Technologies

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

HAUCK STARJET BURNER SJ075 SJ980

INDITHERM. Low temperature gas burners

DIVISION FINNED WATER-TUBE WATER HEATERS

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

Flame Safeguard Fault Code Diagnostics

Model 601CRD Oil Burner

Installation and Service Manual

NMG NOZZLE MIX GAS BURNERS

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

FLAT FLAME AND EXCESS AIR BURNERS

Directflow SBDR/SBD SERIES

8+* Bulletin No November 1997

Directflow SBDR/SBD SERIES

mith Mills 3500A Smith Mills 3500A 3500A-3 OIL, GAS OR COMBINATION GAS/LIGHT OIL COMMERCIAL BOILER/BURNER CAST IRON

Direct Fired Heater Model AD Specification

Chemical Processes in the Combustion

BETTER HOME COMFORT AND PEACE OF MIND STARTS WITH THE BEST SERVICE PLANS.

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

Indirect gas-fired air heater

HCLEARFIRE. High-efficiency, modular steam boiler HP

Revitalize Building Mechanical Systems (4619)

SUBMITTAL SCHEDULE & DATA

Gas and dual fuel burners Burner sizes 50 and 90

Weishaupt WG10 and WG20 gas burners LN (Low NO x ) version 2/2002 CA

RL 28/2-38/2-50/2 Low - High Operation

Transcription:

The H/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A backward curved impeller mounted in a machined housing provides combustion air for various furnace pressures or high altitude applications. HG gas burners burn gas under a controlled gas/air pressure mix. Gas is emitted from jets surrounding the air stream, producing a turbulent mixture which burns quietly and efficiently. HL oil burners incorporate a high pressure atomizing design using simplex nozzles. A directly driven fuel oil pump is burner mounted. Consistent fuel/air ratio is maintained regardless of firing rate. A. CONTROLS 1. 120/1/60 control circuit 2. Burner mounted control panel 3. Motor starter(s) 4. Panel signal lights (4) (See Note 5) 5. Low-High-Off firing 6. Fuel changeover switch (combination gas/oil models) 7. Flame safeguard controls (See Note 1) 8. Combustion air proving switch 9. Ignition transformer B. OIL SYSTEM 1. Two stage fuel unit, directly driven 2. Simplex oil nozzle 3. Oil solenoid valve 4. S.S.O. oil solenoid valve 5. Oil metering valve 6. Fuel oil strainer (shipped loose) C. MAIN GAS SYSTEM (See Note 2) 1. Butterfly rate control valves 2. One motorized valve and one solenoid valve 3. Gas shutoff cocks (2) 4. Main gas regulator D. GAS PILOT SYSTEM 1. Gas-electric interrupted pilot (HG, HLG) 2. Shutoff cock 3. Separate pilot regulator and valve 4. Direct spark ignition (HL) E. OTHER EQUIPMENT 1. 3450 rpm blower motor 2. Burner mounting flange 3. Gas manifold is standard on all oil burners for future gas firing GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT IC-1271-07/08 Page 1 of 2 Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 HLG combination gas/oil burners change from one fuel to the other by simply flipping a switch. No burner modifications or readjustments are required when changing from one fuel to the other. Listed by Underwriters Laboratory. CSD-1, GE Gap, F.M. and other regulatory agency control options are available. Every burner is assembled, wired and tested at the factory. F. OPTIONAL EQUIPMENT 1. Control circuit transformer 2. Separately driven remote oil pump set 3. Low-High-Low or full modulation 4. Inverted housing arrangement NOTES 1. U.V. scanner standard 2. All main gas line valves and accessories upstream of butterfly valve are shipped loose 3. Standard motor voltages are 208-230-460/3/60 4. Totally enclosed and 50 cycle motors are optional 5. Signal lights: Power On, Main Fuel, Ignition, and Flame Failure ORDERING INFORMATION (SPECIFY) 1. Burner voltage, phase and cycle (See Note 3) 2. Control Circuit Voltage (120/1/60) 3. Burner model and actual firing rate 4. Flame Safeguard Control 5. Special Code and/or Insurance Requirements 6. Available Gas Pressure Type of fuel determines the model designation Model Fuel HG Gas HL Oil HLG No. 2 Oil / Gas

BURNER SIZE CAPACITIES & SPECIFICATIONS 10 13 15 17 20 21 25 GAS INPUT (Mbtu/hr) (See Note 1) 1,000 1,300 1,500 1,700 2,000 2,100 2,500 OIL INPUT (U.S. GPH) (See Note 2) 7.1 9 10.7 12 14.2 15.0 17.8 BOILER HP @ 80% EFF. (See Note 3) 24 30 36 40 48 50 60 GAS MANIFOLD HP ( w.c.) (See Note 4) 0.9 1.5 1.9 2.4 3.2 3.5 4.7 BLOWER MOTOR HP (See Note 5) 1/3 1/3 1/2 1/2 1/2 1/2 3/4 APPROX. SHIPPING WEIGHT (lbs.) 450 450 450 450 450 450 450 Notes: 1. Gas input based on natural gas at 1,000 Btu/cu.ft. and 0.60 gravity 2. Oil input based on No. 2 oil at 140,000 Btu/gal. 3. Boiler overall efficiency of 80% estimated 4. Gas pressure based on zero furnace pressure. For total pressure at manifold, add furance pressure. 5. Impeller and motor HP is based on altitude up to 2,000 ft. above sea level. For higher altitude or 50 Hz. applications, consult factory NOTE: THESE DIMENSIONS ARE FOR REFERENCE ONLY. SPECIFICATIONS AND DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. DIMENSION DIAGRAM H-SERIES 10, 15, 20 & 25 MODEL HL & HLG - SIZE 1 LOW-HIGH-LOW, LOW-HGIH-OFF 557-0021 Page 2 of 2 IC-1271-07/08

The H/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A backward curved impeller mounted in a machined housing provides combustion air for various furnace pressures or high altitude applications. HG gas burners burn gas under a controlled gas/air pressure mix. Gas is emitted from jets surrounding the air stream, producing a turbulent mixture which burns quietly and efficiently. HL oil burners incorporate a high pressure atomizing design using simplex nozzles. A directly driven fuel oil pump is burner mounted. Consistent fuel/air ratio is maintained regardless of firing rate. A. CONTROLS 1. 120/1/60 control circuit 2. Burner mounted control panel 3. Motor starter(s) 4. Panel signal lights (4) (See Note 5) 5. Low-High-Off firing 6. Fuel changeover switch (combination gas/oil models) 7. Flame safeguard controls (See Note 1) 8. Combustion air proving switch 9. Ignition transformer B. OIL SYSTEM 1. Two stage fuel unit, directly driven 2. Simplex oil nozzle 3. Oil solenoid valve 4. S.S.O. oil solenoid valve 5. Oil metering valve 6. Fuel oil strainer (shipped loose) C. MAIN GAS SYSTEM (See Note 2) 1. Butterfly rate control valves 2. One motorized valve and one solenoid valve 3. Gas shutoff cocks (2) 4. Main gas regulator D. GAS PILOT SYSTEM 1. Gas-electric interrupted pilot (HG, HLG) 2. Shutoff cock 3. Separate pilot regulator and valve 4. Direct spark ignition (HL) E. OTHER EQUIPMENT 1. 3450 rpm blower motor 2. Burner mounting flange 3. Gas manifold is standard on all oil burners for future gas firing GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT IC-1272-07/08 Page 1 of 2 Model: HG, HL, HLG Burner Sizes: 30, 34, 35, 40, 42, 45 HLG combination gas/oil burners change from one fuel to the other by simply flipping a switch. No burner modifications or readjustments are required when changing from one fuel to the other. Listed by Underwriters Laboratory. CSD-1, GE Gap, F.M. and other regulatory agency control options are available. Every burner is assembled, wired and tested at the factory. F. OPTIONAL EQUIPMENT 1. Control circuit transformer 2. Separately driven remote oil pump set 3. Low-High-Low or full modulation 4. Inverted housing arrangement NOTES 1. U.V. scanner standard 2. All main gas line valves and accessories upstream of butterfly valve are shipped loose 3. Standard motor voltages are 208-230-460/3/60 4. Totally enclosed and 50 cycle motors are optional 5. Signal lights: Power On, Main Fuel, Ignition, and Flame Failure ORDERING INFORMATION (SPECIFY) 1. Burner voltage, phase and cycle (See Note 3) 2. Control Circuit Voltage (120/1/60) 3. Burner model and actual firing rate 4. Flame Safeguard Control 5. Special Code and/or Insurance Requirements 6. Available Gas Pressure Type of fuel determines the model designation Model Fuel HG Gas HL Oil HLG No. 2 Oil / Gas

BURNER SIZE CAPACITIES & SPECIFICATIONS 30 34 35 40 42 45 GAS INPUT (Mbtu/hr) (See Note 1) 3,000 3,400 3,500 4,000 4,200 4,500 OIL INPUT (U.S. GPH) (See Note 2) 21.4 24 25 28.5 30 32.1 BOILER HP @ 80% EFF. (See Note 3) 72 80 84 95 100 108 GAS MANIFOLD HP ( w.c.) (See Note 4) 3.5 4.3 4.5 5.8 6.3 7.1 BLOWER MOTOR HP (See Note 5) 3/4 3/4 1 1 1/2 1 1/2 2 APPROX. SHIPPING WEIGHT (lbs.) 500 500 500 500 500 500 Notes: 1. Gas input based on natural gas at 1,000 Btu/cu.ft. and 0.60 gravity 2. Oil input based on No. 2 oil at 140,000 Btu/gal. 3. Boiler overall efficiency of 80% estimated 4. Gas pressure based on zero furnace pressure. For total pressure at manifold, add furance pressure. 5. Impeller and motor HP is based on altitude up to 2,000 ft. above sea level. For higher altitude or 50 Hz. applications, consult factory NOTE: THESE DIMENSIONS ARE FOR REFERENCE ONLY. SPECIFICATIONS AND DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. DIMENSION DIAGRAM H-SERIES 30, 35, 40 & 45 MODEL HL & HLG - SIZE 2 LOW-HIGH-LOW, LOW-HGIH-OFF 557-0003 Page 2 of 2 IC-1272-07/08

The H/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A backward curved impeller mounted in a machined housing provides combustion air for various furnace pressures or high altitude applications. HG gas burners burn gas under a controlled gas/air pressure mix. Gas is emitted from jets surrounding the air stream, producing a turbulent mixture which burns quietly and efficiently. HL oil burners incorporate a high pressure atomizing design using simplex nozzles. A directly driven fuel oil pump is burner mounted. Consistent fuel/air ratio is maintained regardless of firing rate. A. CONTROLS 1. 120/1/60 control circuit 2. Burner mounted control panel 3. Motor starter(s) 4. Panel signal lights (4) (See Note 5) 5. Full Modulation 6. Fuel changeover switch (combination gas/oil models) 7. Flame safeguard controls (See Note 1) 8. Combustion air proving switch 9. Ignition transformer B. OIL SYSTEM 1. Two stage fuel unit, directly driven 2. Simplex oil nozzle 3. Oil solenoid valve 4. S.S.O. oil solenoid valve 5. Oil metering valve 6. Fuel oil strainer (shipped loose) C. MAIN GAS SYSTEM (See Note 2) 1. Butterfly rate control valves 2. One motorized valve and one solenoid valve 3. Gas shutoff cocks (2) 4. Main gas regulator D. GAS PILOT SYSTEM 1. Gas-electric interrupted pilot (HG, HLG) 2. Shutoff cock 3. Separate pilot regulator and valve 4. Direct spark ignition (HL) E. OTHER EQUIPMENT 1. 3450 rpm blower motor 2. Burner mounting flange 3. Gas manifold is standard on all oil burners for future gas firing GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT IC-1524-06/08 Page 1 of 2 Model: HG, HL, HLG Burner Sizes: 50, 54, 55, 60, 63, 70, 80, 84, 90 HLG combination gas/oil burners change from one fuel to the other by simply flipping a switch. No burner modifications or readjustments are required when changing from one fuel to the other. Listed by Underwriters Laboratory. CSD-1, GE Gap, F.M. and other regulatory agency control options are available. Every burner is assembled, wired and tested at the factory. F. OPTIONAL EQUIPMENT 1. Control circuit transformer 2. Separately driven remote oil pump set 3. Air atomizing (models HLA or HLAG) system w/separate air compressor 4. Inverted housing arrangement NOTES 1. U.V. scanner standard 2. All main gas line valves and accessories upstream of butterfly valve are shipped loose 3. Standard motor voltages are 208-230-460/3/60 4. Totally enclosed and 50 cycle motors are optional 5. Signal lights: Power On, Main Fuel, Ignition, and Flame Failure ORDERING INFORMATION (SPECIFY) 1. Burner voltage, phase and cycle (See Note 3) 2. Control Circuit Voltage (120/1/60) 3. Burner model and actual firing rate 4. Flame Safeguard Control 5. Special Code and/or Insurance Requirements 6. Available Gas Pressure Type of fuel determines the model designation Model Fuel HG Gas HL Oil HLG No. 2 Oil / Gas

BURNER SIZE CAPACITIES & SPECIFICATIONS 50 54 55 60 63 70 80 84 90 GAS INPUT (Mbtu/hr) (See Note 1) 5,000 5,400 5,500 6,000 6,300 7,000 8,000 8,400 9,000 OIL INPUT (U.S. GPH) (See Note 2) 35.7 37.5 39.2 42.8 45.0 50.0 57.1 60.0 64.2 BOILER HP @ 80% EFF. (See Note 3) 120 125 130 143 150 167 191 200 215 GAS MANIFOLD HP ( w.c.) (See Note 4) 7.3 7.8 8.6 6.5 7.1 8.7 11.2 12.3 14.1 BLOWER MOTOR HP (See Note 5) 2 2 3 3 5 5 5 5 7.5 APPROX. SHIPPING WEIGHT (lbs.) 700 700 700 700 700 700 700 700 700 Notes: 1. Gas input based on natural gas at 1,000 Btu/cu.ft. and 0.60 gravity 2. Oil input based on No. 2 oil at 140,000 Btu/gal. 3. Boiler overall efficiency of 80% estimated 4. Gas pressure based on zero furnace pressure. For total pressure at manifold, add furance pressure. 5. Impeller and motor HP is based on altitude up to 2,000 ft. above sea level. For higher altitude or 50 Hz. applications, consult factory NOTE: THESE DIMENSIONS ARE FOR REFERENCE ONLY. SPECIFICATIONS AND DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. DIMENSION DIAGRAM H-SERIES 50, 55, 60, 70, 80 & 90 MODEL HL & HLG - SIZE 3 557-0001-B Page 2 of 2 IC-1273-07/08

The H/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A backward curved impeller mounted in a machined housing provides combustion air for various furnace pressures or high altitude applications. HG gas burners burn gas under a controlled gas/air pressure mix. Gas is emitted from jets surrounding the air stream, producing a turbulent mixture which burns quietly and efficiently. HL oil burners incorporate a high pressure atomizing design using simplex nozzles. A directly driven fuel oil pump is burner mounted. Consistent fuel/air ratio is maintained regardless of firing rate. A. CONTROLS 1. 120/1/60 control circuit 2. Burner mounted control panel 3. Motor starter(s) 4. Panel signal lights (4) (See Note 5) 5. Full Modulation 6. Fuel changeover switch (combination gas/oil models) 7. Flame safeguard controls (See Note 1) 8. Combustion air proving switch 9. Ignition transformer B. OIL SYSTEM 1. Two stage fuel unit, directly driven 2. Simplex oil nozzle 3. Oil solenoid valve 4. S.S.O. oil solenoid valve 5. Oil metering valve 6. Fuel oil strainer (shipped loose) C. MAIN GAS SYSTEM (See Note 2) 1. Butterfly rate control valves 2. One motorized valve and one solenoid valve 3. Gas shutoff cocks (2) 4. Main gas regulator D. GAS PILOT SYSTEM 1. Gas-electric interrupted pilot (HG, HLG) 2. Shutoff cock 3. Separate pilot regulator and valve 4. Direct spark ignition (HL) E. OTHER EQUIPMENT 1. 3450 rpm blower motor 2. Burner mounting flange 3. Gas manifold is standard on all oil burners for future gas firing GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT IC-1274-07/08 Page 1 of 2 Model: HG, HL, HLG Burner Sizes: 100, 105, 110, 120, 125 HLG combination gas/oil burners change from one fuel to the other by simply flipping a switch. No burner modifications or readjustments are required when changing from one fuel to the other. Listed by Underwriters Laboratory. CSD-1, GE Gap, F.M. and other regulatory agency control options are available. Every burner is assembled, wired and tested at the factory. F. OPTIONAL EQUIPMENT 1. Control circuit transformer 2. Separately driven remote oil pump set 3. Air atomizing (models HLA or HLAG) system w/separate air compressor 4. Inverted housing arrangement NOTES 1. U.V. scanner standard 2. All main gas line valves and accessories upstream of butterfly valve are shipped loose 3. Standard motor voltages are 208-230-460/3/60 4. Totally enclosed and 50 cycle motors are optional 5. Signal lights: Power On, Main Fuel, Ignition, and Flame Failure ORDERING INFORMATION (SPECIFY) 1. Burner voltage, phase and cycle (See Note 3) 2. Control Circuit Voltage (120/1/60) 3. Burner model and actual firing rate 4. Flame Safeguard Control 5. Special Code and/or Insurance Requirements 6. Available Gas Pressure Type of fuel determines the model designation Model Fuel HG Gas HL Oil HLG No. 2 Oil / Gas

BURNER SIZE CAPACITIES & SPECIFICATIONS 100 105 110 120 125 GAS INPUT (Mbtu/hr) (See Note 1) 10,000 10,500 11,000 12,000 12,500 OIL INPUT (U.S. GPH) (See Note 2) 71.4 75.0 78.5 85.7 90.0 BOILER HP @ 80% EFF. (See Note 3) 239 250 263 287 300 GAS MANIFOLD HP ( w.c.) (See Note 4) 14 15.5 17 20 22 BLOWER MOTOR HP (See Note 5) 7 1/2 7 1/2 7 1/2 10 10 APPROX. SHIPPING WEIGHT (lbs.) 1,100 1,100 1,100 1,450 1,450 Notes: 1. Gas input based on natural gas at 1,000 Btu/cu.ft. and 0.60 gravity 2. Oil input based on No. 2 oil at 140,000 Btu/gal. 3. Boiler overall efficiency of 80% estimated 4. Gas pressure based on zero furnace pressure. For total pressure at manifold, add furance pressure. 5. Impeller and motor HP is based on altitude up to 2,000 ft. above sea level. For higher altitude or 50 Hz. applications, consult factory NOTE: THESE DIMENSIONS ARE FOR REFERENCE ONLY. SPECIFICATIONS AND DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. DIMENSION DIAGRAM H-SERIES 100-120 MODEL HL & HLG - SIZE 4 557-0028 Page 2 of 2 IC-1274-07/08