ASSEMBLY INSTRUCTIONS FOR THE PUMP AND CONTROL UNIT ZPS 18a-01

Similar documents
8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN.

Operating and assembly manual: Electric instantaneous flow heater Admiral

1.1 Controller General Information

PORTABLE AIR CONDITIONER

E U R O V E N T CERTIFIED PERFORMANCE

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

User Manual for model

GH10PA USER MANUAL. Program version 01 MANUAL FOR CONTROLLER FOR CONTROLLING CENTRAL HEATING BOILERS FIRED WITH PELLETS AND OATS

pod Installation, Operation & Maintenance viridian Pod-PV, Pod-ST solar v

PORTABLE AIR CONDITIONER

Congratulations! You've just purchased a new Marey ECO tankless water heater and will soon begin to enjoy the benefits of going tankless.

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

User manual. Dishwasher ZDT15002

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

DC200 Digital Dispenser Operating Manual

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N

Instruction Manual Model: IM03A

HR 601 C A AUS. ENGLISH Instructions for use Page 2

IMPORTANT SAFEGUARDS Danger! Danger of burns!! Important!

Installation and instruction manual SOLAR STATION

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

Tankless Electric Water Heater MS-C2PSU Series

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N

WHA 3000P Hot Air Station

RND Soldering Station. RND W Temperature Controlled Soldering Station Instruction Manual

Operation and Maintenance Haskris LX-Series, R-Series, WW-Series, OPC-Series

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat

User manual. Dishwasher ZDI12001

TH100 Three in One Instant Hot Water Tap

SCHWAN INSTALLATION GUIDE

OPERATION AND INSTALLATION

/04.14_00. De Longhi Appliances via Seitz, Treviso Italia

aura-t TP536/EU ventilation systems

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Controller PCSol 300 FOR SOLAR COLLECTORS. INSTALLATION AND OPERATION MANUAL 62.X.2 REVISION SOFTWARE

ONX908MTW-0/24V MULTI STAGE THERMOSTAT

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Components for solar heating systems

/ De Longhi Appliances via Seitz, Treviso Italia

INSTRUCTION MANUAL PORTABLE FRIDGE/FREEZER. Models: RVX-35 / RVX-45 / RVX-50 RVX-55 / RVX-65 / RVX-75

EDD61 & EDD91 Extractors

Read the operation instruction carefully before use. Ensure good storage of the operation instruction for late consultation.

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Operating principle. Bolero XL (2008)

AIR COOLER OPERATING INSTRUCTIONS MODEL NO: ARC-30 ARC-30. Instruction Manual

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

FAVORIT 34502VI0. EN User manual

Operating principle. Quinto

/ De Longhi Appliances via Seitz, Treviso Italia

E U R O V E N T CERTIFIED PERFORMANCE

SCHWAN INSTALLATION GUIDE

User Manual. Dishwasher ZDM17301SA ZDM17301WA

WHA 3000V Hot Air Station

user manual Dishwasher ESL 46510

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Friwa Compact. Operating instructions EN

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

FAVORIT VI DISHWASHER USER MANUAL

Smart Temp. Model

MTDPC. (also known as MTPC) INSTALLATION AND OPERATION MANUAL MultiTrode Pump Controller

User manual. Dishwasher ZDT15010FA

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

INSTALLATION & TECHNICAL MANUAL

Contents. 1 Important 4 Power failure backup function 7 Electromagnetic fields (EMF) 7

Read this manual carefully before installing and using the appliance. This will ensure optimum results and maximum safety.

MODEL NO: MC02 BATCH NO: PR3547

DIGITAL MODULATING BOILERS

L A B K C D E F G H M* I J N*

Tools Required Small, flat-head screwdriver Phillips screwdriver (for mounting hardware) Wire stripper and cutter

Dual-Hose Portable Air Conditioner User Manual

hc9620 Ceramic Hob Manual for Installation, Use and Maintenance

ST 53.1 User s manual

Autofill counter top water boiler

* depending on model.

INSTALLATION & USER MANUAL

/2010 US/CA

WSK300 Multifunction Wall Control

VADA - Rain2Main Automatic Rainwater Controller

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4

Instruction Manual for Electric Ovens OO757X OO986X

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

Attention. Please handle this product with care and inspect it regularly to ensure it is in good working order.

Operating instructions Page 12

INSTALLER S & OWNER S MANUAL

FAVORIT34502VIO. EN User Manual

User manual. Dishwasher ZDT12041FA

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

INSTALLATION MANUAL GEO-BOOST GROUND LOOP HEAT EXCHANGER

FWC153, FWC304, FWC604 & FWC624

Product waste disposal - Protection of the environment:

ЭКСПЛУАТАЦИЯ И МОНТАЖ ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ

HOT TAP WATER EXCHANGER with solar pump-group ENSOL IT INSTALLATION AND OPERATION MANUAL WARRANTY CARD

12" Commercial Vacuum Sealer INSTRUCTIONS

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

General System Layout Sketch

OWNERS' GUIDE PRECISION WATER SYSTEMS WATER DISTILLER. Water Systems FOR MODELS: PWS MANUFACTURED BY:

Transcription:

ASSEMBLY INSTRUCTIONS FOR THE PUMP AND CONTROL UNIT ZPS 18a-01 1. Use and construction of the pump and control unit The pump and control unit is designed to work with solar collectors in systems with required flow of the heat transfer fluid up to 18 l/min, depending on the surface of solar collectors installed. The pump and control unit is a compact device, in a foamed polypropylene cover, it contains accessories necessary for correct functioning of the solar collector system. Because of the pump and controller used, the unit is an integral solution without the possibility of replacing these elements with others available on the market. The flow in the solar collector system is fully adjustable in a multi-stage manner, ensuring maximum efficiency of solar energy collection. The pump unit is adapted to support systems with a single set of solar collectors and a single boiler. The guarantee of proper operation of the pump unit is the correct placement of temperature sensors. For this purpose, it is recommended to use the appropriate connection unit for the boiler. 1 2 3 4 5 6 7 8 9 10 11 12 1 Pump and control unit cover 2 G425-P01 Controller 3 Manual vent with hose 4 Release valve top 5 Safety valve 6bar 6 Circulation pump WILO 15 / 6 - PR 7 Ball valve 8 Release valve bottom 9 Thermometer 0 120 C 10 Air separator with a check valve 11 Pressure gauge 0 6bar 12 Power cord Figure 1 Pump and control unit Assembly of the pump and control unit. Steps of the assembly. a. Attach the pump and control unit to the wall using 3 anchor screws. b. Connect the hydraulic connections of the pump and control unit with the solar collectors, the boiler, and the expansion tank, as shown in the schematic diagram of the system (fig. 2). c. Place the temperature sensors in the right places in the system and connect to the controller (fig. 3 and fig. 4)

Diagrams of pump and control unit connections in the solar system T1 Hot water Supply from central heating boiler Circulation T2 Return to central heating boiler T3 Cold water Fig. 2 Filling and starting the system. The system should be filled with a heat transfer fluid, which is a water solution of propylene glycol, with a crystallization temperature of 25 C with an addition of an inhibitor pack, protecting the system from corrosion. Attention!!! The fluid with the freezing temperature stated should not be diluted with water. Fill the system with heat transfer fluid using a turbine-driven pump. Steps of the filling and starting procedure: a. Pump hoses: connect the supply hose to the top release valve (4), the overflow hose to the bottom release valve (8). Fill the pump's tank with the heat transfer fluid, open the bottom release valve (8) and start the turbine-driven pump. b. During the entire time of filling and starting the system, leave the manual vent valve slightly open (3) and also check the venting of the pump (pump unit branch between the lower tee and the check valve in the bottom of the separator) by unscrewing the central screw (6). c. Leave the turbine-driven pump working until completely ventilating the system. d. Close the drain valve (8) and increase the system pressure to about 2.5 bar indicated by the pressure gauge (11). e. Plug the controller into 230V AC mains and turn on the circulation pump in manual mode; leave the circulation pump in manual mode for a period from few to several minutes. f. If the system operates quietly without noise caused by air bubbles circulating with the fluid, close the manual vent valve (3) and possibly increase pressure in the system in accordance with paragraph d. g. Disconnect pump hoses from the valves (4 and 8). h. Switch the controller to automatic mode by pressing again. G425 P01 electronic controller G-425-P01 controller is a device designed and produced to be used with solar collector systems. This product has been created on the basis of a faultless modern microchip technology. The controller has a modern look and is very easy to use, thanks to its user panel which features a simple keyboard and an LCD screen. This controller works with a dedicated pump WILO RS15/ 6-3 - PR providing change of flow in the full range of the pump s operation. The controller cannot be used to work with commonly used pumps for solar systems with a manual change of rotational speed. The only user-adjustable parameter is maximum temperature of water heated by solar panels.

Electrical system and rules for connecting. Electrical system (regardless of its type) must be ended with a plug socket equipped with a safety contact. The use of a socket without the protective conductor terminal is a risk of electric shock!!! The crimp connectors used are approved for continuous load of 16A!!! They feature a fine thread and special plates to prevent crossing of wires, and therefore only a slight tightening of the cable creates a maximally good contact and the use of greater force may lead to breaking the thread. After connecting the device to power, dangerous 230VAC voltage can occur on the cables and connectors, regardless of whether the controller is switched on or off, therefore ANY WIRING REPAIRS AND CHANGES can be made only with a completely disconnected power supply!!! System diagram and connection of the controller. The G-425-P01 controller is equipped with 3 inputs allowing connecting 3 temperature sensors NTC10ktype (T1, T2, T3) and 4 outputs for connecting one 3-speed collector pump (P). Fig. 3 Schematic diagram of the system. Using the controller. Fig. 4 Electrical connection of the controller. Switching the controller on and calibration of the touch keyboard. When connected to a power source, the controller calibrates the touch keyboard for about 6 seconds. During the calibration, do not place your hands close to the sensors, which would cause incorrect calibration and, consequently, keyboard malfunction. After the keyboard calibration process, the controller goes into standby mode (if it was in standby move before switching it off), or into operation mode (if it was in operation move before switching it off). If the keyboard is not working properly, rerun the calibration process. To do this, disconnect and then reconnect the controller to a power source and wait for the touch keyboard to recalibrate, remembering not to place your hands near the sensors. Standby. In this mode, the LED display shows the symbol "- -".

In standby mode, all outputs are disabled and the alarm sound is inactive. Pressing will cause the controller to exit from standby mode and go to automatic mode. Automatic mode. In automatic mode, the collector pump control algorithm is implemented, based on information read from the temperature sensors T1, T2 and T3. During the active automatic mode, the display shows the temperature of one of three temperature sensors (T1, T2 or T3) or the collector pump speed level, but if the temperature displayed is less than -9 C, a "Lo" message is displayed, and the temperature displayed is greater than 99 C, an "UP" message is displayed. Switching between successive points is done using the button in the sequence: temperature T2 temperature T3 collector pump speed level temperature T1 temperature T2... Information about which point is currently displayed is shown by continuous light of one of the four green LEDs, located on the diagram by the symbols of the individual points. If no buttons are pressed for 60 seconds, the controller will revert to displaying temperature T2. For a few seconds after power up, instead of the temperature, symbol of 'un' (uncertain value) will be shown on the display until the controller has completed the first measurement loop. During this time, the collector pump is turned off. Pump operation is signalled by a green LED located by the pump symbol according to the diagram: the LED is not lit - the pump is not operating, the LED blinks - the pump is working, but if the pump is working, and the collector pump speed level is displayed, the LED is lit with continuous light. In addition, the collector pump status is displayed by a dot in the lower right corner of the display: if dot is not lit up - the pump is not working, if the dot is lit up - the pump is working. When displaying information about the collector pump speed level, the left display shows the current gear of the pump, from 0 to 3, where 0 means the pump is stopped, 1 means the slowest gear and 3 the fastest gear of the pump. The right display indicates the collector pump phase speed level, from 0 to 5, where 0 means the pump is stopped, 1 means minimum phase speed level of the pump, and 5 means maximum phase speed level of the pump. In case of sensor failure, and the user selects to display readings from this sensor, the display instead of the temperature value displays the symbol "Er", and the LED on the diagram assigned to this sensor is lit with a continuous light. If another point is currently displayed, the LED on the diagram assigned to the damaged sensor flashes. Additionally, if there is damage to at least one of temperature sensors, acoustic signal is active until the failure is removed or the signal is muted by the user, by pressing any key. Pressing the button Pressing the button By pressing the button causes switching to the menu for viewing and setting of the maximum temperature. will enter the manual mode. the controller will switch to standby. Viewing and setting the maximum temperature. Switching to the menu for viewing and setting the maximum temperature is achieved by pressing when automatic mode is active. After entering this mode the current value of the maximum temperature is displayed (flashing). Repeatedly pressing the will increase the temperature by 1 C, and after crossing 85 C it will be substituted by the value of 40 C. Hold the button longer will activate the auto repetition function. The controller automatically returns to the automatic mode, and the new value of the maximum temperature will be saved, if no buttons are pushed for 5 seconds. Manual mode. Switching to the manual operation mode is achieved by pressing when the automatic mode is active. After entering this mode, the pump is running at the maximum speed level (3, 5), the LED by the pump symbol in the diagram flashes in a cycle of 3 short flashes and a pause, and a short sound signal is generated for about 10 seconds. Similarly as during the active automatic mode, the display shows the temperature of one of three temperature sensors (T1, T2 or T3), but if the temperature displayed is less than -9 C, a "Lo" message is displayed, and the temperature displayed is greater than 99 C, an "UP" message is displayed. Switching between successive points is done using the button in the sequence: temperature T2 temperature T3 temperature T1 temperature T2... Information about which point is currently displayed is shown by continuous light of one of the three green LEDs, located on the diagram by the symbols of the individual points. If no buttons are pressed for 60 seconds,

the controller will revert to displaying temperature T2. For a few seconds after power up, instead of the temperature, symbol of 'un' (uncertain value) will be shown on the display until the controller has completed the first measurement loop. Information about the failure of one of the sensors is displayed the same way as in automatic mode. The controller will return to automatic mode automatically after 10 minutes after activating the manual mode, or after pressing. By pressing the button the controller will switch to standby. Protection To protect the system from high temperature, circulation of steam bubbles and cavitation, if the temperature T 1 120 C, protection will be activated, the pump will be switched off and temperature T1 on the LED display will flash. Protection will be disabled if T 1 118 C. With the introduction of sets in which the collectors have an absorber made entirely of aluminium, an additional protection was introduced. If temperature T 3 70 C, the pump will be switched off, and temperature T3 on the LED display will flash. Protection will be disabled if T 3 68 C. Alarm. If the temperature parameters indicate a no-flow status (e.g. aerated system, pump failure), the controller activates the alarm - FL will be shown on the display and a sound alarm will activate. The alarm will be active until confirmation by the user by pressing any key, or until the state that caused the alarm is changed. Information regarding labelling and disposal of worn out electric and electronic equipment. ATTENTION! The symbol found on the product or its packaging indicates selective disposal of worn out electric and electronic equipment. What this means is that this product should not be thrown away with other household waste. Proper disposal of old and worn out electric and electronic equipment will help avoid potentially unfavourable effects on the environment and human health. The responsibility of selective disposal of worn out equipment lies with the user, who should return it to a proper facility collecting worn out equipment. NOTES This equipment is not intended for use by persons (including children) with reduced physical, sensory or mental ability, or persons who have no experience or knowledge of the equipment, unless it is done under supervision or in accordance with the operating manual for the equipment by a person responsible for their safety. Make sure that children do not to play with the equipment If the non-detachable cord is damaged, it should be replaced by the manufacturer or a specialised repair facility or by a qualified person in order to avoid risks