Installation, Operation and Maintenance Instructions Electric Flow Heater OM009

Similar documents
Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Installation, Operation and Maintenance Instructions for PlantPac Steam Plate Heat Exchanger Package

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013

Installation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010

Rycroft Storage & Non-Storage Calorifiers. Installation, Operation & Maintenance Manual

BOILER HOUSE PRODUCTS GMS

Installation, Operation and Maintenance Instructions for ThermaFlex Brazed Plate Heat Exchangers

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Multi-Elec COMPACTE BOILER

Installation, operating and servicing instructions

Instruction Manual. Pharma-line ESE02198-EN Original manual

Powerstock Storage Tank

REG NO FM BS EN ISO HEADER TANK HEAT EXCHANGER. Installation, Operation & Maintenance Guide

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

HYDRAULIC OIL COOLER Installation, Operation & Maintenance Guide

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

HYDRAULIC OIL COOLER. Installation, Operation & Maintenance Guide

OPERATING AND MAINTENANCE MANUAL FOR VERTICAL IMMERSION HEATED STEAM BOILERS. Technical Control Systems Limited MODELS "VIHS"

ADVANCE ECB ELECTRIC COMBINATION BOILER

4 route 147, C.P.33 Coaticook, Qc J1A 2S8

MULTI ELEC. Electric Boilers TECHNICAL MANUAL

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Assessment Schedule - TS.6

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Fusion 200, 300 & 500

SERVICE MANUAL. For Service & Parts please call APK THERMAL at or SAFETY INSTRUCTION

SEALED THERMAL STORE

Installation instructions

FITTING, OPERATION, INSTALLATION & SERVICING INSTRUCTIONS

Why Vaillant? Because the ecotec delivers day in, day out. Vaillant ecotec boiler range. The TECHNICAL Brochure

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

Installation and Operating Instructions ISH ELECTRIC STEAM SUPERHEATER

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Unvented Electric Water Heater 10/15 litre Undersink

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

Cylinder/Pipe Thermostat Cat. No. TRT044. Operating & Installation Instructions

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Astro 2 circulator models. Installation and operating instructions

STREBEL S-CB + Cascade Kits

Inverted Bucket Steam Traps

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

MAXIMISER Semi-Storage Calorifiers

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

LHE OIL LINE HEATER ELECTRIC TYPE

OWNERS GUIDE TO INSTALLATION AND OPERATION

Powerflow Unvented water heater

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Instruction Manual HWR MODEL RESISTO-FLO ELECTRIC BOILER

VIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and

ADVANCE ELECTRIC THERMAL STORE

Installation and operating instructions. DK energy storage and DK energy buffer

HEAT TRANSFER STORAGE CALORIFIERS EC SERIES SC SERIES BT SERIES

ELECTRIC UNIT HEATER UH SERIES

Understand and apply domestic central heating system installation and maintenance techniques

REG NO FM BS EN ISO EXHAUST GAS HEAT EXCHANGERS. Installation, Operation & Maintenance Guide

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

InterSeptor Centrifugal Separators Operating & Maintenance Manual

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

INFINITY FLUIDS CORPORATION

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

LONGONI ENGINEERING SRL

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

ALLEGHENY BRADFORD CORPORATION

CRU-S Series Stainless Steel Condensate Recovery Unit

TERMO ELECTRIC BOILER INSTALLATION MANUAL OSO TERMO RS -M

THERMflow Thermal Store Cylinders

Akva Lux VX District heating substation for indirect heating and domestic hot water systems

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

Alpha CombiMax 350 and 600

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Quantum. Installation, User and Service Manual. Hot Spring

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

INSTALLATION & MAINTENANCE MANUAL PVI ELECTRIC HOT WATER SUPPLY BOILER

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

Series 1140 and 1141 Temperature Regulators

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

Combined electric boiler and domestic hot water store

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

MEGAFLO HE Iss 1

Schuco SS-TC/SC Cylinders

Friwa Compact. Operating instructions EN

CUBEflow Thermal Store Tank

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

Amptec. Electric flow boiler

Titanium Plate Heat Exchanger. Installation & Operating Manual

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

CPM, CPMSP Cascade header kits Installation, Commissioning and Maintenance Instructions

SECTION DOMESTIC WATER HEATERS

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

Transcription:

Installation, Operation and Maintenance Instructions Electric Flow Heater OM009 Calorifiers Heat Exchangers Pressurisation Units Sales Tel: 01457 835700 Sales Fax: 01457 832700 E-mail: sales@gmsthermal.co.uk Riverside Works, Egmont Street, Mossley Ashton-Under-Lyne, OL5 9NE The operating and maintenance instructions contained within this package are for electric flow heaters. Please note that an electronic version of these instructions is available from our website. Please contact our sales office for further information. Rev Date By Details B 16/09/2015 Lauren Ashmore Updated to new layout Revision Details

Contents Contents... 1 1.0 Standard Unit Information & Description... 2 2.0 PED Information... 3 3.0 Installation... 3 4.0 Commissioning and Operation... 4 5.0 Maintenance... 4 6.0 End of Life Disassembly, Recycling & Disposal... 5 7.0 Recommended Spares... 5 Page 1

1.0 Standard Unit Information & Description GMS flow heaters are used in various applications, their main use being on closed heating systems such as heating radiator circuits or for space heating requirements. They are also ideal for fresh water applications including swimming pool heaters or as a pre-heat or back up for domestic hot water storage calorifiers. They are an ideal back up service for existing boiler plant permitting boilers to be shut down during maintenance programmes or periods of low demand. They can also be used as a back up to main boilers during periods of high demand. The range consists of models ranging from 30 kw to 600 kw. Other applications may also arise with different water temperatures and materials of construction. Shell (Other materials on request) Design Data Maximum Working Pressure Hydraulic Test Pressure Design Code Standard Material Options Schedule Copper (EFHS) Copper-Lined Steel (EFHL) Galvanised Steel (EFHG) Stainless Steel (EFHS) Glass-Lined Steel (EFHP) Shell Side Refer to Vessel Nameplate Refer to Vessel Nameplate Refer to Vessel Nameplate Please refer to our brochure for standard connection and dimensional data. Page 2

2.0 PED Information The standard range of electric flow heaters are designed in accordance with the requirements of the Pressure Equipment Directive 97/23/EC. Units classed as SEP in the PED category are not supplied with a CE mark. Units in category 1 and above are CE marked and appropriate markings and certification is supplied with each unit. It is the responsibility of the user and/or installer to ensure that the unit is installed and operated safely, and in accordance with the instructions supplied within this manual. 3.0 Installation Lifting: Use lifting eyes where fitted. Do not lift a Calorifier using the insulation (if fitted). Straps may crush the insulation. Siting: Unless specifically ordered for outside siting, the heater must be sited indoors. Foundations must be firm and level to prevent settling, pipe strain or distortion of the Calorifier. Unless specifically ordered differently, the Calorifier should be installed in a level position. Ensuring that enough room exists to withdraw the immersion heater from the shell. Installation: Protective covers/plugs may be fitted to connections to protect them in transit. These must be removed prior to use. If a connection is not required seal it appropriately. Check for and remove any foreign material which may have got into the connections. Pipe-work connected to the Calorifier should be supported to prevent loads being transmitted to the Calorifier. Provide for thermal expansion with bends and expansion joints. To avoid corrosion, ensure that pipe-work materials are compatible with Calorifier materials. Fit isolation valves prior to Calorifier connections to facilitate servicing. For flanged connections tighten bolts in a diametrically opposite sequence to load the flanges evenly onto the gasket. For screwed connections use a thread sealant approved for use with potable water by the local water authority. Ensure adequate venting for air removal during filling and operation. Pressure relief valves (and bursting discs if fitted) should have their outlets piped away to a safe disposal point. Allowance must be made for thermal expansion and contraction of the fluids. Immersion Heaters The immersion heaters are tested before leaving the factory and are ready for installation. The immersion heaters are thoroughly dried prior to despatch but moisture may collect in the heater during transit or site storage. It is important that prior to connecting the heaters to the mains, an insulation test must be made across each element to earth. If the insulation resistance is less than 50,000 Ohms, the heaters must be dried out prior to connection. This can be done by placing the heaters in a low temperature oven or by passing a low voltage (maximum of 25% of the working voltage) through the elements in open air to a maximum temperature of 60 C. The heaters should be switched off at regular intervals to prevent overheating. For further instructions on the immersion heater, refer to separate literature Control Panel Prior to commissioning and wiring to the immersion heaters, check all the control circuitry and main circuit connections are tight using the appropriate tools. Remove all loose items from inside the panel and other items that may be fastened to the cables. Page 3

4.0 Commissioning and Operation Do not operate the equipment at pressures or temperatures in excess of those specified on the GMS nameplate attached to the vessel. Flowrates should not exceed design values specified for the Calorifier. Test the control system with the mains live and the main isolator switched to ON. Connect the thermostats and switch ON the main isolator switch. As the system is cold, the contactor should close and the heater ON lamp should light. Remove one wire from the control thermostat and the contactor should open switching OFF the heater lamp. Replace the wire to the control thermostat and repeat the process for the safety thermostat. It is assumed here that the secondary pipework is already full Start with primary, secondary flow and return valves closed and secondary re-circulation pump is off. Close the drain valve. Slowly fill the heater. Carefully open the secondary flow and return valves Switch secondary re-circulation pump on Reconnect the immersion heater. With the control thermostat disconnected, operate the contactor with the TEST switch. This will give manual control of the heater stages. If satisfactory, reconnect the thermostat. Check that the heater switches off by reducing the temperature on the control thermostat. Check that all gaskets are effective when the unit is operating - some bolt tightening may be necessary after the unit has been first heated and subsequently from time to time. Following installation and commissioning it is advisable to remove, clean and re-assemble any strainers. All fluids must be drained when the unit is out of operation to prevent freezing or possible corrosion. 5.0 Maintenance To drain the Calorifier down (secondary side) Obtain a complete set of replacement gaskets from GMS Thermal Products Ltd. It is assumed here that all isolation valves (except drain) are open at the start. Switch off electrical power to the immersion heater. Switch off the secondary system pump and isolate secondary return to heater. Let the heater cool to a safe temperature Isolate the secondary flow If the heater shares a vent with other heater, isolate it from the common vent using the 3-way valve (it will now vent to atmosphere). If the heater has no vent it may be necessary to remove a fitting above the Calorifier to let air in during draining. Pipe the drain to a drain point and open the drain valve. The heater shell internal condition can be inspected by removing the immersion heater allow visual examination Re-fit new gaskets and re-fill the heater according to the commissioning instructions above. Check the thermostats every 12 months by removing and testing the contact resistance and comparing the switch point by immersion in hot water using a separate thermostat. Page 4

6.0 End of Life Disassembly, Recycling & Disposal Please consult the general assembly drawing and product data sheets of the supplied unit for specific information regarding the materials used. Dispose of all material responsibly and in accordance with all local regulations. For further information, please contact the GMS Technical Team on 01457 835 700. 7.0 Recommended Spares The recommended spares for the Direct Storage Cylinder are; - Immersion Heater Gaskets - Immersion Heater Elements (if applicable) Please contact our sales department for recommended spares prices and availability. Page 5