VX51 and VX55 with Munters Drive 51 and 55 Exhaust Fan

Similar documents
MD Munters Drive. Instruction Manual. Munters Drive * Motor and Controller Replacement Kit. Motor & Controller Replacement kit for AX and VX Fans

RC Series Discharge Cones

FM Munters Drive. Instruction Manual. Munters Drive * Motor Replacement Kit. Motor Replacement Kit for AX and VX Fans

Flatsided Discharge Cone Models: 54GC & 54GCX

AX51 with Munters Drive

BA2702-P Linear Actuator

Motor Kit for SW Shutter. Instruction Manual. Motor Kit for SW Shutter. Models: FA2685. Munters Corporation, November 2013 QM1017r6

BA4000 Series Curtain Machine

BI28SP Ceiling Inlet. Instruction Manual. BI28SP Ceiling Inlet. Bi-Flow, Spring Actuated. Models: BI28SP BI28SP-01

14" - 24" CLASSIC Direct Drive Fans

IA Inlet Actuator. Instruction Manual. IA Inlet Actuator Models: IA0090 IA0090P. Munters Corporation, March 2017 QM1235r1

INLET DAMPER WALL FAN UNIT

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

User Manual Box Exhaust Fan Series (Belt Drive)

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

Panel Fan Series Operators Manual (Galvanized and Polymer)

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

57" Fiberglass Exhaust Fan with Cone

Manual for use and maintenance. + CE Declaration of conformity. TU600 - TU800 Chimney fan. Ag/MIT/UmGB /14 rev 1.0

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

Installation & Maintenance Instructions

Positive Pressure Filtered Swine Facilities

AIR HEATING PRODUCTS

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

Panel Fan Series Operators Manual (Galvanized and Polymer)

92 RAILWAY ST. SEAFORTH, ONTARIO CANADA, N0K 1W0 TEL: ABSOLUTE AIR INSTALLATION MANUAL

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

MFS. Manual for use and maintenance. + CE Declaration of conformity MFS. Air circulation fan. Models: MFS36 - MFS52. Ag/MIT/UmGB /13 rev1.

WDP. Installation manual WDP. Gutter system. Ag/MIT/UmEN /14 rev 1.0

LEAVE THIS MANUAL WITH HOMEOWNER

INSTALLATION and OPERATION BALL WASHER MODEL NO: BW-022

T-Series Air Conditioner T15 Model

e Bath Fan with Light User s Guide

LOKPRINT. Industrial Apparel Label Station. Operation / Maintenance And Parts List. Users Manual AVERY DENNISON. Manual Edition 5.0.

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL

e Bath Fan with Light User s Guide

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

CEILING FAN OWNER'S MANUAL

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

READ AND SAVE THESE INSTRUCTIONS

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

The Zonix OWNER S MANUAL. Ceiling Fan. Model No. FP4620** READ AND SAVE THESE INSTRUCTIONS. Net Weight 9.07 kg (20 lbs)

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

Installation, Operation, and Maintenance Information

INSTALLATION and OPERATION BALL WASHER, HIGH CAPACITY MODEL NO: BW-022AN

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

CEILING FAN OWNER'S MANUAL

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

CEILING FAN OWNER'S MANUAL

T-Series Air Conditioner T20 Model

AMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL

Camarillo 52 Ceiling Fan

CEILING FAN OWNER S MANUAL

SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount.

FLCH4R Garage and Utility Electric Heater

THE DAVENPORT CEILING FAN INSTALLATION INSTRUCTIONS

CEILING FAN OWNER'S MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

52 CEILING FAN. Owner s Manual Models #50336, 50337

Manual for MC91 SETUP INSTRUCTIONS

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

THE GUSTO CEILING FAN INSTALLATION INSTRUCTIONS

CELEBRITY DELUXE 52" indoor fans

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

Manual update 2016 MC37/MFC3600

CEILING FAN OWNER'S MANUAL

Manual for MC37/MFC3600

Operating Instructions & Parts Manual Models 99533, 99532

Torrena 42 Ceiling Fan

15-Year Limited Warranty

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

Model H1011.8/H1011.8HPS Water Cooler

CEILING FAN OWNER'S MANUAL

Product catalogue. Solutions for the Dairy segment

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

CPL Series Pedestal Convection Heater

(The chances are you re never going to read me) Owner s Manual. Model S10E.

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

CEILING FAN OWNER'S MANUAL

R Series B & T2 Model

THE VALOR CEILING FAN INSTALLATION INSTRUCTIONS

52 BERKSHIRE CEILING FAN

2 Installation Instructions For Vari-Fan Ceiling Fans Installation Instructions For Vari-Fan Ceiling Fans 11

Bathroom Exhaust Fan

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

User s Manual and Operating Instructions

Transcription:

Instruction Manual Aerotech VX51 & VX55 with RC Cone and Munters Drive* *Protected by U.S. Patent No. 6,386,828, 6616404; 6953320 and other Patents Pending VX51 and VX55 with Munters Drive 51 and 55 Exhaust Fan Models: VX51DFxxCT-Hx VX51DFxxCP-Hx VX55DFxxCT-Hx VX55DFxxCP-Hx Munters Corporation, August 2018 QM1190r7 1

VX51 and VX55 Fans with RC Cone and Munters Drive Instructions for Use and Maintenance Thank You: Thank you for purchasing a Munters VX51 and VX55 Fan with RC Cone and Munters Drive. Munters equipment is designed to be the highest performing, highest quality equipment you can buy. With the proper installation and maintenance it will provide many years of service. Please Note: To achieve maximum performance and insure long life from your Munters product it is essential that it be installed and maintained properly. Please read all instructions carefully before beginning installation. Warranty: For Warranty claims information see the Warranty Claims and Return Policy form QM1021 available from the Munters Corporation office at 1-800-227-2376 or by e-mail at aghort.info@munters.com. Conditions and Limitations: Products and Systems involved in a warranty claim under the Warranty Claims and Return Policy shall have been properly installed, maintained and operated under competent supervision, according to the instructions provided by Munters Corporation. Malfunction or failure resulting from misuse, abuse, negligence, alteration, accident or lack of proper installation or maintenance shall not be considered a defect under the Warranty. 2 QM1190r7 Munters Corporation, August 2018

Index Chapters Page 1. Unpacking the Equipment 4 1.1 Parts List 4 1.2 Fan Dimensions 4 2. Installation Instructions 5 2.1 Fan Installation 5 2.2 PT Style Shutter 10 2.3 PV Style Shutter 11 3. Electrical Wiring 12 3.1 Recommended Wire Routing 12 3.2 Electrical Wiring 14 3.3 Recommended Wiring 15 4. Operation and Maintenance 20 4.1 Operation 20 4.2 Maintenance 20 5. Troubleshooting 21 6. Winterizing 22 6.1 Winterizing 22 6.2 Winter Weather Protection 22 7. Exploded View and Parts List 23-24 Munters Corporation, August 2018 QM1190r7 3

Unpacking the Equipment 1. 1.1 Parts List Before beginning installation, check the overall condition of the equipment. Remove packing materials, and examine all components for signs of shipping damage. Any shipping damage is the customer's responsibility and should be reported immediately to your freight carrier. Fan is shipped complete with all accessories. Remove shutter, guard and cone sections before proceeding with installation. Each Fan includes: 1 Belt Drive Fan 1 Cone 1 Guard 1 Shutter 1 Hardware Package as follows: HP1156 51 /55 Fan, One Piece Cone, PT/PV Shutter ID Qty. Cat. No. Description [A] 12 KS2105 #14 x 1.5 Lag Screw, SS [B] 8 KS0650 1 4-20 x 7 8 Truss Head Bolt, SS [C] 8 KN1717 1 4-20 Hex Flange, Nylock Nut, SS [D] 8 KW3012 1 4 x 1 O.D. Flat Washer, SS [A] [B] [C] [D] 1.2 Fan Dimensions J I H G A B E A C2 D K - Dia. D C F1 F2 C1 K - Dia. Fan Specifications: 60Hz shown (50Hz available) Power: 230 VAC or 230/460 VAC Phase: 1 or 3 Fan Dia. A B C1* C2* D E F1* F2* G H I J K-Dia. 51" 7" 29 1 2" 7 1 2" 8" 60 1 2" 59" 30 1 4" 26 1 2" 54 3 16" 23 3 16" 11" 2 5 16" 65" 55" 7 3 8" 31 3 8" 7 3 4" 7 3 4" 63 5 8" 62 3 4" 27 7 8" 31 7 8" 58 9 16" 25 15 16" 11 3 4" 2 5 16" 70" *Dimensions Plus/Minus 1 4", Field Verify WALL OPENING (I.D., framed) 56 1 4"W. x 57 3 4"H. 60" W. x 61 1 4" H. 4 QM1190r7 Munters Corporation, August 2018

Installation Instructions 2. 2.1 Fan Installation Step 1 Construct framed opening to correct size according to the Wall Opening listed in chart A below. See Figure 1A and 1B Chart A Fan Dia. Wall Opening (W. x H.) Minimum Spacing 'Z' Center To Center Dimension 51 56 1 4 W. x 57 3 4 H. 12 recommended; 10 minimum 66 Minimum 55 60 W. x 61 1 4 H. 12 recommended; 10 minimum 70 Minimum Ceiling 12" See minimum spacing notes in Chart A Z W (see chart A) H (see chart A) Framing Figure 1A Frame Construction Top of Post Wall 6 x 6 Post - 6'O.C. 'Z' W. (see Chart A) H. (see Chart A) Figure 1B Post Construction Munters Corporation, August 2018 QM1190r7 5

Chapter 2 Installation Instructions Step 2A Insert fan into the framed opening from the inside. While lifting fan up tight to framing, fasten top of fan with (3) Lag Screw [A]. See Figure 2A and 2B. Next, fasten bottom of fan, then both sides with remaining (9) Lag Screw [A]. Install flashing around opening tight to fan and caulk around fan to seal. 2 x 8 Header Boards Post #14 x 1.5" Lag Screws [A] #14 x 1.5" Lag Screws [A] OUTSIDE INSIDE OUTSIDE INSIDE 2 x 4 Framing Figure 2A Frame Construction Figure 2B Post Construction Wall Framing 4" Minimum Framing for fan, Top and Sides 2 x 8 Banner Boards Step 2B If fan needs to be mounted, so that shutter does not stick into building then frame fan as shown in Figure 3. Top and sides require 4" minimum and bottom requires 2" minimum. Wall Opening (See Chart A, Page 4) 2" Minimum Framing for fan, Bottom Wall Framing Figure 3 6 QM1190r7 Munters Corporation, August 2018

Chapter 2 Installation Instructions Step 3 Installing the one piece cone may require 2 people. If temperature is above 50 F then proceed to Step 5. If temperature is below 50 F then proceed to Step 4. Step 4 Using Locking Sheet Metal Pliers bend the cone tabs outward to allow the cone to slide onto the fan easier. See Figure 4. 51/55RC Cone Cone Tabs Locking Sheet Metal Pliers Cone Tab Figure 4 Step 5 Look for the TOP label on the Polycone and set the top of the Polycone on top of the fan orifice and install (2) Truss Head Bolts [B] through holes in fan outlet through the slots in the cone at about the 10 and 2 o clock positions and fasten with Washers [C] and Flange Nuts [D]. Truss head of each bolt must be on the inside of the fan outlet; washers and flange nuts must be on outside of cone. See Figure 5A and 5B. Finger tighten nuts only at this time. Top Cone Tab 51/55 RC Cone Flange Nut [D] Hole at 10 O'clock Washer [C] 51/55RC Cone (outside) Fan Outlet (inside) Truss Head Bolt [B] Figure 5B Figure 5A Munters Corporation, August 2018 QM1190r7 7

Chapter 2 Installation Instructions Step 6 Work down the sides of the cone, sliding the cone tabs onto the fan until the bottom tab is in place. Keep pressure on the cone to make sure tabs stay on the fan. Install (6) Truss Head Bolts [B], Washers [C] and Flange Nuts [D] in the remaining holes in the fan outlet and slots in the cone to finish securing cone to fan. See Figure 5B and Figure 6. Tighten all nuts at this time, making sure not to over tighten. 51/55 RC Cone Remaining Holes Figure 6 Note: If installing your existing guard in the new Polycone, then proceed to Step 9. If installing the new snap-in guard then proceed to Step 7. Step 7 The snap-in guard has a slight conical shape to it so, when installed the center of the guard should protrude out slightly. See Figure 7A. 51/55 RC Cone Guard Figure 7A 8 QM1190r7 Munters Corporation, August 2018

Chapter 2 Installation Instructions Step 8 Starting at the bottom of the cone, locate one of the guard tabs and put the guard tab through the guard slot in the cone. See Figure 7B. Then work up around the guard and install each of the other guard tabs in each of the corresponding guard slots. Some force may be required to snap the last tab into the last slot, pull out on the center of the cone while pushing in on the guard tab until it snaps into place. Cone Guard Guard Tab Guard Tab Figure 7B Step 9 If installing your existing guard into the new cone, locate the flat guard mounting pads on the cone and drill a 9 32 dia. hole in the center of each pad. Then insert existing guard into cone with the guard eyelets facing away from you. Line up each eyelet with a hole in the guard pads. Secure guard to cone using (8) existing Bolts and Nuts. See Figure 8A and 8B. Tighten all nuts at this time. Fan Outlet Guard Slot in cone Guard Mounting Pad Nut Bolt Guard Guard Mounting Pad Figure 8A Guard eyelet Figure 8B Munters Corporation, August 2018 QM1190r7 9

Chapter 2 Installation Instructions 2.2 PT Style Shutter Step 10 Insert PT Shutter into fan by sliding the bottom flange of shutter into bottom shutter clips and pressing shutter inward. See Figure 9. Note: PT Shutter extends into room 2 5 16 from back of fan. PT Shutter Figure 9 Fixed Bottom Shutter Clip Step 11 Fasten shutter in place by rotating the side and top shutter clips over the shutter flanges. See Figure 10. Installation is now complete, proceed to Electrical Wiring Section. Figure 10 10 QM1190r7 Munters Corporation, August 2018

Chapter 2 Installation Instructions 2.3 PZ Style Shutter Step 12 Insert PZ shutter into fan by sliding the bottom flange of shutter into bottom shutter clips and pressing shutter inward, See Figure 11A. Fasten shutter in place by rotating the side and top shutter clips over the shutter flanges, See Figure 11B. Installation is now complete, proceed to electrical wiring section. PV Shutter Figure 11A Fixed Bottom Shutter Clip Figure 11B Munters Corporation, August 2018 QM1190r7 11

Electrical Wiring 3. 3.1 Recommended Wire Routing: The Munters Drive Fan comes with a coil of electrical cable that is pre-wired to motor. Find the end of the cable and route it outside the fan and connect it to the incoming power supply and/or the safety cut-off switch. (Safety cut-off switch by others). See Figure 12A. Junction Box Electrical Cable Figure 12A WARNING: Fan is designed to be operated with shutter in place. Do not apply power to fan without shutter being installed. 12 QM1190r7 Munters Corporation, August 2018

Chapter 3 Electrical Wiring 3.2 Electrical Wiring! WARNING All wiring should be installed in accordance with National, State, and Local electrical codes. Fans used to ventilate livestock buildings or other rooms where continuous air movement is essential should be connected to individual electrical circuits, with a minimum of two circuits per room. For electrical connection requirements, refer to diagram on motor nameplate and to information enclosed with the environmental control to be used. High Voltage, disconnect power before servicing. Single Phase and Three Phase Munters Drives: Power supply for fans to have Circuit Breaker or Fuse Protection. The installer must refer to NEC and local codes to ensure safety and compliance. See Figure 12B & 12C. If recommended lightning protection was purchased, wire it to the fan power supply as shown and secure the lightning protection unit near the disconnect or the bus panel. See Figure 12B & 12C. NOTE: A safety cut-off switch should be located adjacent to each fan. 240 VAC Power Supply for Fan L1 L2 G Safety Cut-Off Switch T1 T2 G 240 VAC Power Out to Fan Recommended Lightning Protection FC2003, 230V, 1 Phase Figure 12B Single Phase Safety Cut-Off Switch Three Phase Power Supply for Fan L1 L2 L3 G T1 T2 T3 G Three Phase Power Out to Fan Motor KEY: L1=Line 1 L2=Line 2 L3=Line 3 H=Hot N=Neutral G=Ground Recommended Lightning Protection FC2006, 230V, 3 Phase FC2009, 460V, 3 Phase Figure 12C Three Phase Munters Corporation, August 2018 QM1190r7 13

Chapter 3 Electrical Wiring 3.3 Recommended Wiring The Munters Drive fan ships configured for simple ON/OFF operation. When electrical power is applied to the main cable and the RUN Switch is in the ON Position, the fan will start and run at full speed. See Figure 13A. RUN Switch Circuit Board in Munters Drive Box Figure 13A Default Operation Full Speed ***WARNING*** The Blue Box electrical enclosure must not be removed from mounting bracket. Removing Blue Box from the mounting bracket will void the warranty. Any water or other damage to the controller will not be covered if the Blue Box is removed. ***NOTE*** All Low Voltage wire must be shielded cable. i.e. Belden 8770 or equivalent. 14 QM1190r7 Munters Corporation, August 2018

Chapter 3 Electrical Wiring When making connections to Munters Drive Box, be sure to use the supplied watertight fittings with only 1 cable per fitting. If watertight fittings are not used or if 2 cables or more are in 1 watertight fitting, equipment failure from water damage will not be covered under warranty. If 2 or more cables are used in 1 watertight fitting, they must be sealed on both sides of Munters Drive Box wall to prevent water infiltration. If you are going to run the Munters Drive with a signal from a control, carefully remove 6 screws and the cover and save to reinstall later. Carefully punch the knock-out from the bottom of the Munters Drive Box and install the Watertight connector as shown. See Figure 13B and 13C. Munters Drive Box Screw Munters Drive Box Cover Knock-out Figure 13B Munters Drive Box Watertight Connector Figure 13C Munters Corporation, August 2018 QM1190r7 15

Chapter 3 Electrical Wiring To operate the Munters Drive On/Off with a control, Slide the RUN switch, located on the circuit board in the Munters Drive Box, to the OFF position. Now wire an ON command from the COMMON terminal to the input relay in the control and from the output of the control relay to the RUN terminal in the Munters Drive Box. See Figure 13A & 13D. RUN Switch Circuit Board in Munters Drive Box Munters Drive Box Munters Drive Box Jumpers Junction Box (By Others) Control Relay Figure 13D On/Off Remotely ***WARNING*** The Blue Box electrical enclosure must not be removed from mounting bracket. Removing Blue Box from the mounting bracket will void the warranty. Any water or other damage to the controller will not be covered if the Blue Box is removed. ***NOTE*** All Low Voltage wire must be shielded cable. i.e. Belden 8770 or equivalent. 16 QM1190r7 Munters Corporation, August 2018

Chapter 3 Electrical Wiring To operate the Munters Drive Off/Low/High with a control, slide the RUN switch, located on the circuit board in the Munters Drive Box, to the OFF position. Now wire an ON command from the COMMON terminal to the input relay in the control and from the output of the relay to the RUN terminal in the Munters Drive Box. Then connect the output of the control relay for LOW to the REDUCED FLOW terminal in the Munters Drive Box. See Figure 13E. RUN Switch Circuit Board in Munters Drive Box Control Relay Munters Drive Box Figure 13E Off/Low/High Remotely ***WARNING*** The Blue Box electrical enclosure must not be removed from mounting bracket. Removing Blue Box from the mounting bracket will void the warranty. Any water or other damage to the controller will not be covered if the Blue Box is removed. ***NOTE*** All Low Voltage wire must be shielded cable. i.e. Belden 8770 or equivalent. Munters Corporation, August 2018 QM1190r7 17

Chapter 3 Electrical Wiring To Operate the Munters Drive variable with a 10-0V Signal, slide the RUN switch, located on the circuit board in the Munters Drive Box, to the ON position. Connect wires from the 0-10V IN and 0-10V COMMON terminals in the Munters Drive Box to the 10-0V output in the control. See Figure 13F. RUN Switch Circuit Board in Munters Drive Box Munters Drive Box Jumper Junction Box (By Others) 10-0V Output In Control Figure 13F Variable Speed Operation ***WARNING*** The Blue Box electrical enclosure must not be removed from mounting bracket. Removing Blue Box from the mounting bracket will void the warranty. Any water or other damage to the controller will not be covered if the Blue Box is removed. ***NOTE*** All Low Voltage wire must be shielded cable. i.e. Belden 8770 or equivalent. 18 QM1190r7 Munters Corporation, August 2018

Chapter 3 Electrical Wiring To operate the Munters Drive Off/Variable with a 10-0V Signal, slide the RUN switch, located on the circuit board in the Munters Drive Box, to the OFF position. Now wire an ON command from the COMMON terminal to the input relay in the control and from the output of the control relay to the RUN terminal in the Munters Drive Box. Also, connect wires from the 0-10V IN and 0-10V COMMON terminals in the Munters Drive Box to the 10-0V output in the control. See Figure 13G. RUN Switch Circuit Board in Munters Drive Box Munters Drive Box Munters Drive Box Control Relay Junction Box (By Others) 10-0V Output In Control Figure 13G On/Off with Variable Speed Operation WARNING: Fan is designed to be operated with shutter in place. Do not apply power to fan without shutter being installed. Munters Corporation, August 2018 QM1190r7 19

Operation and Maintenance 4. 4.1 Operation 1) INITIAL START-UP: With electrical power off, verify that the fan propeller turns freely and that all fasteners are secure. With shutter in place, turn on electrical power and confirm that the fan operates smoothly.! WARNING 2) TEMPERATURE ADJUSTMENTS: Set the fan control to the temperature shown on your Munters ventilation system drawing, or to a value which will provide the desired environmental conditions. 4.2 Maintenance The following inspection and cleaning procedures should be performed monthly: 1) INSPECT PROPELLER: Check that propeller is secure on drive hub and that there are no signs of damage. The blades are of a self-cleaning design and should not require maintenance. 2) CLEAN regularly for best results: FAN MOTOR: Remove any dust accumulation from motor using a brush or cloth. (DO NOT use a pressure washer). A clean motor will run cooler and last longer. At the same time, verify that the motor is secure in its mount. SHUTTER: Carefully clean dust from shutter and frame so that shutter opens and closes freely. A brush or cloth should be used. GUARD: Clean any dust or feathers from fan guards using a brush. Dirty guards can reduce airflow. Moving parts, disconnect power before servicing.! WARNING High Voltage, disconnect power before servicing.!! WARNING Do not power wash electrical devices. WARNING 3) CHECK FASTENERS: For safety, all fasteners should be inspected. Tighten any loose connections. 4) INSPECT FAN CONTROL: With power disconnected, inspect all electrical connections. Wiring should be secure and in good condition. Remove any dust build-up from control case and sensor using a soft brush or cloth. Do not apply power with shutter out. NEVER CLEAN ELECTRICAL EQUIPMENT WITH A PRESSURE WASHER! 20 QM1190r7 Munters Corporation, August 2018

Troubleshooting 5. 5.1 Troubleshooting! WARNING! WARNING High Voltage, disconnect power before servicing. Moving parts, disconnect power before servicing. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Fan Not Operating Fan control set above room temperature Blown Fuse or open circuit breaker Propeller blade contacting fan housing Fan control defective (i.e. Farm Premium, etc.) Fan Does Not Start Caution: There is a 10 second delay for the fan to start when an 'On' command is present. Fan Operating - Insuffi cient Airfl ow Excessive Noise Excessive Vibration Munters Drive motor/controller issue Shutter or Damper door jammed Guard dirty/clogged 10-0V signal set incorrectly Propeller blade contacting fan housing Motor loose on mount Propeller damaged Set to a lower temperature Replace fuse or reset breaker Realign motor in fan housing Repair or replace control 1. Verify AC voltage is present at fan. 2. Turn AC power off to fan for 1 minute 3. Verify Prop turns freely a. If not contact Munters Product Support b. If it turns freely go to next step 4. Turn AC power back on to fan a. If starts up and runs, fan OK Periodically observe fan to verify it is still running If it continues to run, fan is OK If fan stops, look through clear window in drive cover to check what drive display reads. Contact Munters Product Support b. If fan tries to start but stops, look through clear window in drive cover to check what drive display reads. Contact Munters Product Support c. If fan doesn't try to start, verify 'On' command signal is present at circuit board. Also, slide the switch on the circuit board to the 'On' position. Clean shutter or damper door Clean guard Check and adjust 10-0V signal Sand fan housing to remove high spot Tighten fasteners Replace propeller Munters Corporation, August 2018 QM1190r7 21

Winterizing 6. 6.1 Winterizing In most climates, it is probable that the ventilation system will never need to operate at a total capacity during the colder winter months. Consequently, it is advisable to winterize those fans which will not be used in cold weather to avoid unnecessary heat loss and condensation. To winterize, turn fan control off. Install the insulated closure panel over the fan intake. If you don t have an insulated closure panel, a piece of rigid insulation material can be used. Remember the insulation panel must be removed before warmer weather returns. NOTE: At least one single speed fan should be left uncovered and with power available to provide air movement in the event of variable speed control difficulties. 6.2 Winter Weather Protection To prevent cone or fan damage from snow or ice sliding off building roof, weather protection must be provided. A weather shelter may be constructed to cover the entire fan, See Figure 14, or snow guards may be placed on the roof, See Figure 15. Provide Weather Shelter Over Fans Snow Guards located per manufacturers recommendations* Building Wall 6" Min. Ceiling Fan with Discharge Cone Fan with Discharge Cone Figure 14 Figure 15 *Snow Guard Suppliers Company Name Phone No. Fax No. Web Site Snojax, Inc. 800-766-5291 717-697-2452 www.snojax.com Polar Blox 800-298-4328 814-629-9090 www.polarblox.com LM Curbs 800-284-1412 903-759-3598 www.lmcurbs.com Alpine Snow Guards 888-766-4273 888-766-9994 www.alpinesnowguards.com! IMPORTANT Munters Product and System Warranties do not cover cone or fan damage from external sources. Note: Snow guards are designed to prevent sudden, dangerous snow and ice slides when attached to the building roof according to manufacturers recommendations. The supplier listing above is given as a reference only. Munters does not endorse any specific snow guard product and no performance warranty is implied. 22 QM1190r7 Munters Corporation, August 2018

Exploded View 7. 10 8 12 13 Munters Corporation, August 2018 QM1190r7 23

Chapter 7 Parts List Catalog No. Item VX51 VX55 Part Name/Description 1 FH3751 FH4755 Guard Kit, cone, PVC CTD 1 2 FH3551 FH3555 Discharge cone, Plastic, (1) Piece 1 3 FP1151SS FP1155SS Propeller, 3-blade w/set screws, Aluminum 1 4 FH2352 FH2356 Fan housing w/clips, FG 1 5 FH1968 FH1968 Pivoting Shutter clip, PL 4 6 FH3723 FH3756 Strut, right, VX, Munters Drive ver2, w/inserts, Aluminum 1 7 FP2064 FP2064 Hub, Prop adapter, 1" DIA ODx4.5"L shaft, STL 1 8 Various* Various* Motor for Munters Drive, less controller 1 9 KE2535 KE2535 Cable, Power, 1ph Munters Drive controller, 16/3,144"L 1 KE2536 KE2536 Cable, Power, 3ph Munters Drive controller, 16/4,144"L 1 10 Various* Various* Controller, VX Munters Drive 1 11 FH3722 FH3755 Strut, Left, VX, Munters Drive ver2, w/inserts, Aluminum 1 12 FH1967 FH1967 Fixed Shutter clip, PL 2 13 PT51 PT553 Shutter, belled inlet, plastic 1 14 PV51 PV553 Shutter, all plastic 1 * Contact offi ce for replacement part numbers for your fan confi guration. VX Munters Drive Fans are developed and produced by Munters Corporation, Lansing, Michigan U.S.A. 1-800-227-2376 Munters Europe AB, Isafjordsgatan 1, P.O. Box 1150, SE-164 26 Kista, Sweden. Phone +46 08 626 63 00, Fax +46 8 754 56 66. Munters Corporation 2691 Ena Drive Lansing, MI 48917 U.S.A. Phone +1 800-227-2376, Fax +1 517-676-7078 www.munters.us Australia Munters Pty Limited, Phone +61 2 6025 6422, Brazil Munters Brasil Industria e Comercio Ltda, Phone +55 41 3317 5050, Canada/US Munters Corporation Lansing, MI Phone +1 517 676 7070, China Munters Air Treatment Equipment (Beijing) Co. Ltd, Phone +86 10 80 481 121, Denmark Munters A/S, Phone +45 9862 3311, India Munters India, Phone +91 20 3052 2520, Indonesia Munters, Phone +62 818 739 235, Italy Munters Italy S.p.A., Chiusavecchia, Phone +39 0183 52 11, Japan Munters K.K., Phone +81 3 5970 0021, Korea Munters Korea Co. Ltd., Phone +82 2 761 8701, Mexico Munters Mexico, Phone +52 818 262 54 00, Russia Munters AB, Phone +7 812 448 5740, Singapore Munters Pte Ltd., Phone +65 744 6828, South Africa and Sub-Sahara Countries Munters (Pty) Ltd., Phone +27 11 997 2000, Spain Munters Spain S.A., Phone +34 91 640 09 02, Sweden Munters AB, Phone +46 8 626 63 00, Thailand Munters Co. Ltd., Phone +66 2 642 2670, Turkey Munters Form Endüstri Sistemleri A.Ş, Phone +90 322 231 1338, USA Munters Corporation Lansing, MI Phone +1 517 676 7070, Vietnam Munters Vietnam, Phone +84 8 3825 6838, Export & Other countries Munters Italy S.p.A., Chiusavecchia Phone +39 0183 52 11 24 QM1190r7 Munters Corporation, August 2018