Gas Pressure Alarm Box SGPA Series. Operation Manual

Similar documents
Alarm Panel Operating Instructions

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

User s Manual. For the SHORE POWER CONNECTION MONITOR MODEL 9151

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

APPLICATION DATA SHEET

DC200 Digital Dispenser Operating Manual

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

SINGLE SPEED SYRINGE PUMP

T a b l e o f C o n t e n t s

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Check It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines

LMA LINE MONITOR ALERT USER S MANUAL

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

Pre-Installation Requirements:

SERIES WM-20(T) & WM-40(T)

QD-ENG-68 Controller for Thermoelectric Thermal Management

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

INSTALLATION INSTRUCTIONS

Installation Instructions. Remanufactured Veeder-Root Overfill Alarm and. Acknowledgement Switch. Overfill Alarm PMP # OEM #

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Vocia VACIE. Reference Guide

Exit Stopper. STI-6400 Series

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

Service Bulletin No. 2930

High Output Vacuum/Pressure Pump

VACIE REFERENCE GUIDE REVISION 1.2.6

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Quick-Start Guide Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input Models and

OPER LV Wheeler Way

PRYCO, INC. FUEL CONTROL

The Remote alarm Panel, TYPE RAPv2

3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

Exit Stopper. STI-6400 Series

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

OPERATION & MAINTENANCE MANUAL TX600

THE GUARDIAN III OWNER S MANUAL. Stops Rangetop Fires Instantly. For Installation, Operation and Maintenance

EG-400 Fire Detection Monitor

FLOW METER KIT #

LifeAlarm Fire Alarm Controls

Addendum for STI-6406 with Dual Access Control

Set-Up Procedures. Before You Start

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

Polypro Acid Wet Bench UCLA Nanolab Yellow Room. Primary contacts: Max Ho, Wilson Lin. PREPARED BY: Steve Franz DATE Rev 2/01/12

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

VetPro Solo Installation

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

CORNELL Emergency Response Systems

STATUS ALARM HISTORY ALARM RESET

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

Platinum Split 4000 & Platinum Split 4000 Fully Ducted COLD WEATHER START KIT Installation Manual

SINGLE CHANNEL SYSTEM TWO CHANNEL SYSTEM

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Elite Control Installation and Operation Instructions

WSK300 Multifunction Wall Control

Endoscope Reprocessor Installation Instructions Endoscope Reprocessing System

Operator s Manual. Commercial Dryer/Air Mover. Standard Models PD350, PD500, PD750. A Tacony Company

Half Inch Round LED Rope Light

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

21-light Remote Annunciator. Owner s Manual

GPC PASTA PRO INSTALLATION & USER OPERATION MANUAL

CryoWiz Liquid Nitrogen Cryogenic Switchover

S150 S300 CONSTRUCTION HEATERS. Rev: August 15, 2008 SERVICE AND MAINTENANCE MANUAL No PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS

Product Manual. The `Safety Shoe (shown below):

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Owner s Guide Installation & Operation

Vess A2000 Series. IO Terminal Board. User Information. Version PROMISE Technology, Inc. All Rights Reserved.

Model 4001 Series Single Channel Controller

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

APPLICATION DATA SHEET

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

Commercial Dryer/Air Mover

Nuclear Associates

Section K CHLORINATION EQUIPMENT

Eldex Column Heater. Operator s Manual

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Model 850 Investigator s Aid Accelerant and Gas Detector Operation and Maintenance

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

DESIGN CLASS FUNCTION

MODEL AV2-C1D1M Hazardous Duty Class I. Div 1, Multitone Alarm Station

INSTALLATION INSTRUCTIONS

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

P R O D U C T D ATA S H E E T

D3000. Installation & Setup Guide

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

PERSONAL COMBUSTIBLE GAS DETECTOR

Checkout Procedure Manual

CO2 Monitoring Frequently Asked Questions for the

OWNERS MANUAL. To Order Parts Call SPEED AIR MOVER

OPERATIONS MANUAL 5 LITER LPG GAS TANKLESS WATER HEATER C AMPER SERIES

GUARDIAN : AUTOGUARD. User Manual

Maintenance & Operating Instructions

30 Misting/Oscillating Fan Model Number 01030

Transcription:

Gas Pressure Alarm Box SGPA Series Operation Manual

Product Description The SGPA Series, Gas Alarm Box, was designed as a method of ensuring the supply of uninterrupted gas, when used in conjunction with a Gentec single or switchover manifold system. Depending on the application and user request, and Indicating Pressure Gauge Switch (IPS) can be placed on high or low pressure sides to activate an alarm. The unit consists of several components: 1. One, Two or Four channel alarm box with audio and visual alarm capability. See Figure 1. 2. The alarm can be operated with voltage of 120vac or 220vac. To change the setting, the back cover must be removed. 3. One Power Cord and Input Connector to connect to dry contact switch wires. 4. Each unit comes complete with GREEN (RUN or IN USE ) indicator lights for each channel to indicate a pressure level above the IPS set point, RED (PRESSURE LOW or REPLACE CYLINDER ) indicator lights for each channel to indicate low pressure or empty status and additionally, a GREEN button at the bottom of the alarm box to ( SILENCE ) the alarm when activated. Installation The enclosure shall be mounted firmly to the wall. It is the installer s responsibility to select the correct mounting hardware, depending on the mounting surface. 1. Remove the five (5) screws from back plate. 2. Measure the alarm box for placement by using the back plate as a template. 3. Insert three flat head screws into the three holes that will hold and firm up the alarm box. See Figure 3. WARNING: The enclosure is not rated, and should not be used in a hazardous area where flammable gases or vapors may be present. NOTE: This enclosure should be mounted within ten feet of a 120 VAC outlet. 4. Mount the alarm box onto the screws to hold firmly. 5. Connect the power cord and the connector cord to tie in the dry contacts (IPS). See Figure 2. 6. Crimp the wires from the gauge switch (IPS) on the regulator or manifold. 7. Connect either the left IPS or right side IPS to the connector cord supplied with the unit. 8. Match the connecting wires per the diagram in the operation manual package.

Operation 1. Push the pinned input connector plug supplied into the alarm box. 2. Push the power cord connector supplied into the alarm box. 3. Plug the power supply into a suitable 120 VAC receptacle. 4. Turn on the power switch - red switch on the right side of alarm box, the front panel should display one of the following states: a. If one or both sides of the manifold or switchover manifold system are below the IPS set point, the red lights will be lit, and the audible alarm should sound. Pressing the SILENCE button will silence the audible alarm, but will not reset the lights to green. b. If both sides of the switchover manifold system are above the IPS set point, the IN USE green button will light, and the audible alarm will not sound. c. If one side of the switchover manifold system is below the IPS set point, the red light on that low side will be lit, and the audible alarm will sound. The other side above the set point will display the green light. Pressing the SILENCE button on the front of the alarm box will silence the audible alarm, but will not reset the light to green. 5. The SGPA lights will reset from red to green only when the pressure is above the set point of the IPS. That is, the reset function will be triggered automatically when the IPS is pressurized above the set point. 6. The audible alarm will not sound for another low pressure red light after the first SILENCE button is pressed and its red light remains on. Thus, a depleted cylinder should be changed when the first alarm sounds to prevent the switchover system from running out of gas completely. SGPA-1-110/220 SGPA-2-110/220 SGPA-4-110/220 Figure 1

Switch and Connectors Four (4) Channel Gas Alarm Box Channel Silence Power Switch Output Connector Power Cord Connector Input Connector Figure 2 Note: See Diagram in the operation manual package for proper wiring configuration scheme.

UHP Medium Flow Regulator HP152T SERIES Alarm Box Dimensions Figure 3 Doc. No.: GR-MAN-SPGGPAB0514 Rev. Level: V1