SD Series Optoschmitt Detector, TO-46 Metal Can Package

Similar documents
HOA Series IR Opaque Optoschmitt Sensor, Transistor Output, Two Mounting Tabs, Plastic Package

Infrared Sensors Line Guide

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

Fiber Optics and Liquid Level Sensors Line Guide

HOA0880-T51. Representative photograph, actual product appearance may vary.

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

Pressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

2 General Application Photoelectric Sensors

Extreme High-Intensity Sensors Thru-Beam and Fiberoptic Penetrates Many Packaging Materials for Content Verification

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

Optical Sensor (2A) Optical Sensor Type Optical Sensor Characteristics. Young Won Lim 9/12/09

An Ambient-Light-Ignoring Infrared Active Motion Detector

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

General Purpose Photoelectric Sensor

2 General Application Photoelectric Sensors

Measurement of Light. Photosensors

2 Specialty Application Photoelectric Sensors

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

onlinecomponents.com

Automatic Self-Adjusting General Purpose Sensor

Reverse Package Infrared LED IR25-21C/TR8

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

Technical Data Sheet 5mm Infrared LED, T-1

Quadrature Speed and Direction Sensors

Datasheet: K-22 LO Sensor

The Affordable, All-Purpose Sensor That's EZ To Use!

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

HOA6480 Series Barcode Sensor Infrared Products

E PIR Motion Detector. Features. General Description. Applications. Single Sensor Application Circuit

BASIC-Tiger Application Note No. 029 Rev Waking up sleeping tigers. Gunther Zielosko. 1. Basics Real Time Clock

Issue 4. Bipolar Hall-Effect Digital Position Sensor ICs: SS40F, SS40AF. Sensing and Internet of Things. Datasheet

Exercise 1: IR Transmission and Reception

Web Site: Forums: forums.parallax.com Sales: Technical:

AUTOMATIC STREET LIGHT CONTROL SYSTEM USING MICROCONTROLLER

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

A5364. Ionization Smoke Detector with Interconnect

C-Bus Four Channel General Input Unit Installation Instructions

2 General Application Photoelectric Sensors

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

Installation Instructions for the 600 Series Optical Encoders

Synchronous Detector

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

Infrared Ceiling Mount Sensor

2 General Application Photoelectric Sensors

Issue B. Bipolar Hall-Effect Digital Position Sensor ICs: SS41, SS41-L, SS41-T2, SS41-T3, SS41-S, SS41-SP. Sensing and Internet of Things

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

FIRERAY 5000 range USER GUIDE

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

Class 1 laser beam sensor safe for your eyes

Web Site: Forums: forums.parallax.com Sales: Technical:

Design of Microwave Anti-theft Alarm Based on Microcontroller

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

LCZ Series Hall-effect Zero Speed Sensors

Interactive Catalog Replaces Catalog Pages

S3F8S28. Smoke Detector. Revision 0.00 February Samsung Electronics Co., Ltd. All rights reserved.

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. The Intelligent Solution CONTENTS

Series 65 Product Guide MAN 3036

GENERAL APPLICATION SENSORS NEW! MINI-EYE. General Application Photoelectric Sensors. Small, Rugged and Powerful... yet Low in Price MINI-EYE 2-55

FF-ST4 Series. Type 4 Safety Light Curtains. Potential Applications. Features

Micropower Omnipolar Digital Hall-Effect Sensor ICs

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

English. Series. Installation and Use Manual

2 General Application Photoelectric Sensors

TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.

Class 1 laser beam sensor safe for your eyes

Pyroelectric Infrared Sensor PIR

Laser Collimated Beam Sensor

A5348 Ionization Smoke Detector with Interconnect and Timer

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

Laser Distance Sensor Type M Analog-Output

D6T. Contactless measurement creating energy-efficient and comfortable living spaces. MEMS Thermal Sensors

Contents. Photoelectric Sensors / Standard Sensors...4. Safety Sensors Photoelectric Sensors / Miniature Sensors... 12

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

Linear Current Sensors

Commercial Series TriTech Motion Detector. Reference Guide

Smoke Detector - NEW. page 1

Class 1 laser beam sensor safe for your eyes

Infrared Detectors. Special-Sensors for. Automation

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Characteristics of different sensors used for Distance Measurement

Beam Detectors. The 6500 Series

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Fire & Security Products. Siemens Building Technologies Group

1Hz,16Hz, S2 S3 S4 S5 S6 S7 S8 ALARM REGISTER COMPARATOR WEEK SECONDS MINUTES HOURS DAYS MONTHS YEARS /12 1 /24 1 /7 /28-1 /31

F 2 MC-8FX FAMILY MB95200 SERIES SMOKE DETECTOR DEMO REFERENCE SOLUTION 8-BITMICROCONTROLLER APPLICATION NOTE

WARNING MISUSE OF DOCUMENTATION

FEATURES AND BENEFITS

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

Smoke Detector Demo Reference Solution

Increased safety and reducing energy consumption with the motion control RPI 01

FCX-11AB5-3XX-XX 155Mbps BIDI SFP TRANSCEIVER(100Km)

Emerald 3000 MK3 GJD010 Lighting Controller

Transcription:

Representative photograph, actual product appearance may vary. Due to regional agency approval requirements, some products may not be available in your area. Please contact your regional Honeywell office regarding your product of choice. Features TO-46 metal can package 6 (nominal) acceptance angle High noise immunity output TTL/LSTTL/CMOS compatible Buffer (SD5600) or inverting (SD5610) logic available Mechanically and spectrally matched to SE3450/5450, SE3455/5455 and SE3470/5470 infrared emitting diodes Description The SD5600/5610 series is a family of single chip Optoschmitt IC detectors mounted in a TO-46 metal can package. The photodetector consists of a photodiode, amplifier, voltage regulator, Schmitt trigger and an NPN output transistor with 10 kohm (nominal) pull-up resistor. Output rise and fall times are independent of the rate of change of incident light. Detector sensitivity has been internally temperature compensated. The TO- 46 package is ideally suited for operating in hostile environments. Device Polarity: Buffer - Output is HI when incident light intensity is above the turnon threshold level. Inverter - Output is LO when incident light intensity is above the turn-on threshold level. file:///c /Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%20.htm (1 of 5)14/03/2005 11:27:59 Õ

Product Type Product Specifications Angular Response (Degree) 12 Turn-on Threshold Irradiance Output Output Logic Package Style Package Components Operating Temperature Range Dark Current IR Component 2.5 mw/cm² maximum 10 kohm Pull-up Buffer T0-46, Dome Lensed Metal -40 C to 100 C [-40 F to 212 F] 250 na Hysteresis (H) 5% to 30% Operating Supply Voltage Supply Voltage High Level Output Voltage Low Level Output Voltage Operating Point Temperature Coeffient Internal Pull-up Resistor Output Rise Time Output Fall Time Clock Frequency Duration of Output Short Vcc or Ground Comment Availability Product Name 4.5 V to 16.0 V 16.0 Vdc 2.4 V minimum 0.4 V maximum -0.76 %/ C 5.0 kohm min., 10.0 kohm typ., 20.0 kohm max. 60 ns 15 ns 100 khz 1.0 second Output is HI when incident light intensity is above the turn-on threshold level. Global Optoschmitt Detector Supply Current max. 12.0-15.0 ma @ 25 C Output Current max. 18 ma file:///c /Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%20.htm (2 of 5)14/03/2005 11:27:59 Õ

file:///c /Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%20.htm (3 of 5)14/03/2005 11:27:59 Õ

PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices, or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. file:///c /Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%20.htm (4 of 5)14/03/2005 11:27:59 Õ

MISUSE OF DOCUMENTATION The information presented in this product sheet (or catalog) is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Copyright Honeywell Inc.1998-2004 All rights reserved. file:///c /Documents%20and%20Settings/rabab/Desktop/Datasheet%20--%20.htm (5 of 5)14/03/2005 11:27:59 Õ