PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

Similar documents
Inverter Wall Mounted

Inverter Wall Mounted

Floor Standing. FV Series PLXSPH1502. COOLING ONLY [60Hz]

Inverter Wall Mounted

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

Inverter Wall Mounted Series

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

OPERATING MANUAL. Operating Manual Handset Wireless. English. OM-GS (0)-DAIKIN Part No.: R MODE TURBO TIMER CANCEL

PLXSID1605. Warning HEAD OFFICE :

CHI NHAÙNH HAØ NOÄI Taàng 12, toøa nhaø Ocean Park Tower, 1 Ñaøo Duy Anh, Quaän Ñoáng Ña, Haø Noäi

OPERATING MANUAL. Before using your air conditioner, please read this operating manual carefully and keep it for future reference.

DAIKIN Modular Inverter Air Cooled Chiller

PCR0709A. Options. Indoor unit

Air conditioners Cooling only

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

A wider lineup of DC Inverter and Non-Inverter air conditioners with 19 models is currently available. You can choose whichever that fits your

Si REMOVAL PROCEDURE. 2.5/3.2/3.5 kw Class. Outdoor Unit Inverter Pair Type

Brief exposure to greenery in urban environments can relieve stress levels and your well-being.

Non Inverter Wall Mounted Series

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Si REMOVAL PROCEDURE. 4.0/5.0/5.2/5.8/6.8/7.5 kw Class. Outdoor Unit Inverter Multi Type

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

AIR CONDITIONER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Ceiling Mounted Cassette Unit

Up to SEER 26.1 Wall Mount Heat Pump

Hi - Wall Split Systems 12K - 18K - 24K

Fan Coil Unit. Product Catalogue. Chilled Water PRODUCT SYSTEM PCXF14. Wall Mounted. Ceiling Cassette. Ceiling Convertible. Ducted

LV Series. SEER 20+ Wall Mount Heat Pump

Split Type Air Conditioners

Fan Coil Unit. Product Catalogue. Chilled Water PRODUCT SYSTEM PCXF14. Wall Mounted. Ceiling Cassette. Ceiling Convertible. Ducted

Service Manual. Inverter Pair Floor Standing Type K-Series. Draft. SiBE [Applied Models] Inverter Pair : Heat Pump

RC-0219-A. Single-Split Non Inverter Series

Operating Functions Temperature Parameters

SERVICE MANUAL. Inverter Wall Mounted Single Split. MODELS Cooling Only. Heatpump SM-5WM-Y-NA-B1

Ceiling Mounted Cassette Unit

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

PCXGA13. Air-Cooled PRODUCT SYSTEM. Residential. Light Commercial. All Product. Commercial / Industrial. Catalogue. For internal reference only R22

Wall Mounted Split Systems G-Series AP - MWM - G - 06A

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

Single - Zone Systems

AIR CONDITIONERS SPLIT TROPICAL RANGE. FLAT SPLIT - Heat & Cool T1 R410a AMD K BTU EAN: AMD K BTU EAN:

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Inverter Y Series.

LV Series. SEER 15+ Concealed Built in Heat Pump

Buttons on remote controller

DESIGN & TECHNICAL MANUAL

RG57F3(B)/BGEFU1 Wireless Remote Controller. Service Manual

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

DESIGN & TECHNICAL MANUAL

Specifications, Performance & Submittal

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

LIFESTYLE RANGE STYLISH, SLIM AND ELEGANT HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

Daikin air conditioners for your home

Owner's Manual TABLE OF CONTENTS

C&H NORDIC Commercial 4 SERVICE MANUAL

DAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

TM: MCCKCM - W B. Fan Coil Units. Models: MWM-FW Series MCM-DW Series MCK-AW/BW Series MCC-CW Series MDB-BW Series

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

DLFEHA. OWNER S MANUAL High Wall Ductless System Sizes 09 to 24 TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS

ART الرفاهية تكنولوچيا بلمسة فنية

DESIGN & TECHNICAL MANUAL

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

DESIGN & TECHNICAL MANUAL

Pure Efficiency Meets Healthy Living NEW 2013

DESIGN & TECHNICAL MANUAL

DAIKIN FAQ SERIES HEATING & COOLING SYSTEMS. INDOOR WALL-MOUNTED UNITS Up to 18.6 SEER / Up to 9.4 HSPF Up to 12.7 EER

Model: Ceiling Cassette V 9k-24k

FAQ. Wall Mount Heat Pump or Cooling Only

The Comfort and Luxury You Deserve

Air Conditioners Heating & Cooling

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

Wired Controller XK60

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

Single and Multi-Zone Ductless Split Systems

AIR CONDITIONING REVERSE-CYCLE INVERTER

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

Owner s Manual TABLE OF CONTENTS

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

w w w. d a i k i n. e u ATXS-E

DESIGN & TECHNICAL MANUAL

Owner s Manual TABLE OF CONTENTS

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

AIR CONDITIONERS, HEATING & COOLING for your home

Multi - Zone Systems. Specification and Performance. 208V-230V 18k-36k. Presents

DAIKIN FCQ SERIES HEATING & COOLING SYSTEMS. ROUNDFLOW CEILING-MOUNTED CASSETTE Up to 18.6 SEER / Up to 10.2 HSPF Up to 13.0 EER

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

SAMSUNG SPLIT AIR CONDITIONER MAX PLUS

Operating Instructions

WALL MOUNTED UNITS SDH W SDH W SDH W SDH W

Transcription:

PLXRMM1606B Wall Mounted FTN-A Series COOLING ONLY [50Hz] 220-240V

ELEGANT, EFFICIENT 1

Daikin s FTN-A series wall mounted air conditioner that not only saves energy but also ozone friendly. Stylish Flat Panel An ideal blend of style and functionality. The front panel is designed for contemporary style without compromising on function. Air intake volume. Sleep Mode Pressing the Sleep button activates the Sleep Mode. This function prevents excessive cooling for a pleasant sleep. Cooling + + + Auto Random Restart with Last- State-Memory In the event of a sudden power failure during operation, unit restarts automatically in 64 different recovery timing patterns (within 180 seconds to 244 seconds) and the unit will operate based on the previous setting (operating mode, temperature setting and fan speed). This ensures that air conditioners in the same building resume randomly instead of all units resuming at the same time, preventing power surge after a blackout. Power failure Power returns Set temp. before Sleep mode begins to operate 30 mins 30 mins 60 mins Operation Stop Restart Time E 2 PROM Sleep mode turns on Cooling operation: 1) After 30 minutes, room temperature is raised by 0.5 C. 2) After 60 minutes, room temperature is raised by 0.5 C. 3) After 120 minutes, room temperature is raised by 1 C. Settings stored before power failure Lower Sound Level users are given more choices. By selecting Quiet mode, the sound pressure level can be reduced down to an unobtrusive 25dBA. 20 Rustling of leaves 30 Pendulum of a wall clock 25dBA for FTN25AXV1 Comparison of noise level 40 Library 50 Normal office (dba) Powerful Operation Powerful Operation is activated by pressing the Turbo button. Once activated, the air conditioner will run on full power with indoor fan running at maximum speed for 20 minutes. This enables the set temperature to be achieved faster. If Turbo and Sleep are activated at the same time, the Sleep mode timer will be reset, it will resume after Turbo function is cleared. T room Compact & Easy-to-Use BRC52A Handset Prominent 40mm LCD display. Real time clock display. Dedicated buttons for Quiet and Turbo functions. T set Start 20min 30min 2

Wall Mounted (50Hz) FTN25/35/50/60AXV1 RN25FAXV1 FTN80AXV1 RN35FAXV1 RN50/60CAXV1 > Uniform air distribution > Quiet operation > Powerful operation > Easy maintenance > Wireless handset BRC52A62 as standard RN71CAXV1 Indoor model name FTN25AXV1 FTN35AXV1 FTN50AXV1 FTN60AXV1 FTN80AXV1 Outdoor model name RN25FAXV1 RN35FAXV1 RN50CAXV1 RN60CAXV1 RN71CAXV1 Nominal Cooling Capacity Btu/h 9000 12000 18000 22000 30000 W 2640 3520 5280 6450 8900 Nominal EER W/W 3.03 3.18 3.02 3.22 3.03 CFM 358/342/282/225/209 372/355/298/242/225 594/531/474/422/381 641/614/537/474/418 950/931/760/661/569 Sound pressure level (Turbo/H/M/L/Quiet) dba 39/37/33/27/25 40/39/35/29/28 44/42/39/36/35 48/46/43/39/37 52/51/46/42/39 Dimensions (HxWxD) mm 288x859x209 310x1124x237 310 X 1289 X 240 Net weight kg 9 14 16 Indoor air quality - Saranet Filter Power supply V/ph/Hz 220-240/1/50 (Power from indoor) Sound pressure level dba 46 47 52 52 56 Dimensions (HxWxD) mm 485x566x256 550x658x273 651x855x328 753x855x328 Net weight kg 21 26 47 47 57 Pipe connection - Liquid mm 6.35 9.52 Pipe connection - Gas mm 9.52 12.70 15.88 Maximum piping length m 20 25 30 45 Maximum piping elevation m 12 15 15 25 Indoor Outdoor 1. Rated cooling capacities are based on the following conditions: Indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB. 2. Pre-charged refrigerant amount is based on standard pre-charged piping length of 7.5m. 3

Function Dictionary C omfortable A irflow Worry Free Wide-Angle Louvers The smoothly curved Wide-Angle Louvers provide wide the indoor unit is placed in a room. Vertical Auto-Swing (up and down) to distribute air across a room. Lifestyle Convenience BLINK Auto Random Restart with Last-State-Memory In the event of a sudden power failure during operation, unit restarts automatically in 64 different recovery timing patterns (within 180 seconds to 244 seconds) and the unit will operate based on the previous setting (operating mode, temperature setting and fan speed). Self-Diagnosis Malfunctioning of air conditioner unit by blinking of LED lights for fast and easy maintenance. New Powerful Operation volume for a 20-minute period. After this, the unit automatically returns to its previous settings. Indoor Unit On/Off Switch The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged. C omfort C ontrol Indoor Unit Quiet Operation Indoor unit operating sound levels are decreased by 3dB(A) from the Low setting fan speed using the wireless remote controller. Programme Dry Function This function automatically reduces the level of humidity. Cleanliness Washable Saranet Filter ensures cleaner air supply. Wipe-Clean Flat Panel single pass of a cloth across their smooth surface. The cleaning. Auto Fan Speed The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature. Timers 24-Hour On/Off Timer This timer can be preset to start and stop at any time within a 24-hour period. The air conditioner is started/ stopped simply by pressing the On/Off timer button on the wireless remote controller. Sleep Mode Pressing the Sleep button activates the Sleep Mode. After 30 minutes, room temperature is raised by 0.5 C. After 60 minutes, room temperature is raised by 0.5 C. After 120 minutes, room temperature is raised by 1 C. 4

Wireless controller BRC52A62 Vertical auto-swing Selectable Mode: Cool, Dry, Fan Turbo function Quiet function On timer setting Real time clock Glow-in-the-dark On/Off switch Fan speed selection: Low, Med, High, Auto Temperature setting: Up & down Sleep mode function Off timer setting Options - Control System Wired controller BRC51A62 Real time clock and day display Turbo function Cool, Dry, Fan mode Delay timer (1 or 2 hours) 7-days programmable timer Low, Med, High, Auto fan speed Temperature operate in ºC and ºF Swing function Quiet function Sleep function On/Off switch Please refer to technical manual for wiring to the wall mounted unit. 5

Notes 6

Warning with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can Read the User s Manual carefully before using this product. The User s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Caution Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. Dealer Lot 60334, Persiaran Bukit Rahman Putra 3, Taman Perindustrian Bukit Rahman Putra, 47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia. http://www.daikinmalaysia.com/ Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan. October 2017 All rights reserved.