PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

Similar documents
PLXSID1605. Warning HEAD OFFICE :

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

Inverter Wall Mounted

Floor Standing. FV Series PLXSPH1502. COOLING ONLY [60Hz]

Inverter Wall Mounted

Ceiling Mounted Cassette Unit

Ceiling Mounted Cassette Unit

RC-0219-A. Single-Split Non Inverter Series

Inverter Wall Mounted Series

Inverter Wall Mounted

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

OPERATING MANUAL. Operating Manual Handset Wireless. English. OM-GS (0)-DAIKIN Part No.: R MODE TURBO TIMER CANCEL

OPERATING MANUAL. Before using your air conditioner, please read this operating manual carefully and keep it for future reference.

Fan Coil Unit. Product Catalogue. Chilled Water PRODUCT SYSTEM PCXF14. Wall Mounted. Ceiling Cassette. Ceiling Convertible. Ducted

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

Fan Coil Unit. Product Catalogue. Chilled Water PRODUCT SYSTEM PCXF14. Wall Mounted. Ceiling Cassette. Ceiling Convertible. Ducted

Hi - Wall Split Systems 12K - 18K - 24K

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

PCXGA13. Air-Cooled PRODUCT SYSTEM. Residential. Light Commercial. All Product. Commercial / Industrial. Catalogue. For internal reference only R22

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

CHI NHAÙNH HAØ NOÄI Taàng 12, toøa nhaø Ocean Park Tower, 1 Ñaøo Duy Anh, Quaän Ñoáng Ña, Haø Noäi

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

Si REMOVAL PROCEDURE. 2.5/3.2/3.5 kw Class. Outdoor Unit Inverter Pair Type

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

DESIGN & TECHNICAL MANUAL

Ultimate VRF System R410A, 50Hz

Heat Pump Air Conditioning Systems

DAIKIN Modular Inverter Air Cooled Chiller

Buttons on remote controller

Residential and Light Commercial Ductless Systems Catalog

Owner's Manual TABLE OF CONTENTS

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Inverter Ducted Air Conditioners

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

CASSETTE DUCT TYPE FLOOR CEILING. Light Commercial 18K BTU - 48K BTU

Owner's Manual TABLE OF CONTENTS

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

Air conditioners Cooling only

C&H NORDIC Commercial 4 SERVICE MANUAL

Si REMOVAL PROCEDURE. 4.0/5.0/5.2/5.8/6.8/7.5 kw Class. Outdoor Unit Inverter Multi Type

Up to SEER 26.1 Wall Mount Heat Pump

LV Series. SEER 15+ Concealed Built in Heat Pump

Product Brochure 2017

USER S MANUAL. Remote Controller 88-MACC007-1A-EN

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

Owner s Manual TABLE OF CONTENTS

LV Series. SEER 20+ Wall Mount Heat Pump

Inverter console UFV system. Compact design and personalised air flow selection

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

Product Brochure Smart Power. Low Profile Ducted

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

PCR0709A. Options. Indoor unit

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

Energy-saving operation

DESIGN & TECHNICAL MANUAL

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

FWC02AAFNMV1 FWC03AAFNMV1 FWC04AAFNMV1 FWC05AAFNMV1 FWC06AAFNMV1

Owner s Manual TABLE OF CONTENTS

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

DUCTED AIR CONDITIONING SOLUTIONS

Just feel well. 2017/2018 Air conditioning

AIR CONDITIONERS, HEATING & COOLING for your home

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

for your home FLXS-B Flexi type unit air to air heat pumps

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Owner s Manual TABLE OF CONTENTS

A wider lineup of DC Inverter and Non-Inverter air conditioners with 19 models is currently available. You can choose whichever that fits your

FBQ. DC Duct Heat Pump or Cooling Only

Inventor of the Inverter Digital Inverter System

Wireless R.C. ALL ALL CLASS DC AUYF24LB

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

A more comfortable, safe and sustainable world

DESIGN & TECHNICAL MANUAL

Daikin air conditioners for your home, shops, restaurants and offices

FAN COILS wall mounted

Wired Controller XK60

DESIGN & TECHNICAL MANUAL

DAIKIN FCQ SERIES HEATING & COOLING SYSTEMS. ROUNDFLOW CEILING-MOUNTED CASSETTE Up to 18.6 SEER / Up to 10.2 HSPF Up to 13.0 EER

DESIGN & TECHNICAL MANUAL

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

Daikin air conditioners for your home

McQuay HydroflexTM Residential and Light Commercial Chilled Water System

Operating Functions Temperature Parameters

40KMC KMQ

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

Air conditioners, heating & cooling for shops,restaurants and offices

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Air Conditioner CONTENTS

Transcription:

Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. Use only those parts and accessories supplied or specified by Daikin. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. PCXSPH1732A 6 Dealer Lot 60334, Persiaran Bukit Rahman Putra 3, Taman Perindustrian Bukit Rahman Putra, 47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia www.daikinmalaysia.com Head office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan. Specifications, designs and other content appearing in this brochure are current as of August 2017 but subject to change without notice. c All rights reserved

The solution for light commercial sector Providing the ideal solution for all kinds of small commercial space such as shops, restaurant and small offices. The Sky Air series offers a complete comfort solution that puts you in total control. Capacity kw 50 60 71 100 125 140 Ceiling Cassette Type (3x3) FCRN50AXVL RR50AGXVL FCRN60AXVL RR60AGXVL FCRN71AXVL RR71AGXVL FCRN100AXVL FCRN125AXVL9 RR125AGXTL9 Duct Connection Standard Static Pressure Type FDMRN50AXVL RR50AGXVL FDMRN60AXVL RR60AGXVL FDMRN71AXVL RR71AGXVL FDMRN100AXVL FDMRN125AXVL9 RR125AGXTL9 FDMRN140AXVL9 RR140AGXTL9 Ceiling Suspended Type FDMRN50DXV1 RN50CAXV1 FDMRN60DXV1 RN60CAXV1 FHRN100AXVL FHRN140AXVL RR140AGXVL FHRN140AXVL9 RR140AGXTL9 Floor Standing Type FHRN50DXV1 RN50CAXV1 FHRN60DXV1 RN60CAXV1 FVRN71AXVL RR71AGXVL FVRN100AXVL FVRN125AXVL9 RR125AGXTL9 FVRN140AXVL9 RR140AGXTL9 Unit Unit RR50AGXVL RR60AGXVL RR71AGXVL RR125AGXTL9 RR140AGXTL9 01 02

Ceiling Cassette Type 4-way air flow This promotes even air distribution covering every corner of the room by combining 4-ways air discharge and large discharge area. Compact body and quiet operation s as an aerodynamically designed Diffuser Turbo Fan. 3x3: FCRN50/60/71/100AXVL, 125AXVL9 Fine square panels Panel size is same for all models. It is easy to maintain a neat appearance when multiple s are installed. Draft resistance has been reduced by incorporating into a single, an impeller and a diffuser to control air flow inside the. The Diffuser Turbo Fan is both quiet during operation and compact. 3x3: 950mm 950mm Wired controller: BRC51A62 Wireless controller: BRC52A62 * optional * supplied with panel Optimal comfort and convenience assured by air discharge modes (FCRN series only) To increase the comfort level of the air conditioned area, the system is built-in with 3 different types of air flow pattern to suit different requirements. 1 Air direction in standard setting For gentle drafts. 2 Air direction in draft prevention setting Select this setting to eliminate direct drafts which can lead to discomfort. 3 Air direction in ceiling soiling prevention setting Recommended for location with light colour ceiling that must be kept spotless. Auto swing Swing pattern COMFORT CLEANLINESS WORK & SERVICING CONTROL FEATURES OPTIONS OTHERS Programme Dry Two selectable temperature sensor Weekly scheduled timer *1 *1 *1 Applicable when wired controller is used. Washable saranet filter Drain pump mechanism Pre-charged for up to 7.5m Self diagnosis Auto random restart Group control by Network Interface Module (NIM) External command control using BAG Fresh-air intake kit Anti corrosion treated heat exchangers The default setting for air swing pattern is 1. The air swing pattern can be selected through the wireless remote control. Two selectable temperature sensors Both indoor and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set at the or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians. * Temperature-sensor on indoor must be used when the air conditioner is controlled from another room. ** Wireless remote controller does not have a temperature-sensor. 03 04

High/Medium/Low/Quiet High setting provides maximum reach while low setting minimises drafts. Operation starts when the preset time of the on timer elapses and stops when the preset time of the off timer elapses. Powerful operation New powerful operation boosts airflow to maximum volume for a 20-minute period with highest fan speed. After this, the automatically returns to its previous settings. Easy installation on/off switch The can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged. Extra protection This covered with insulation material acts as extra protection when installed under very high humidity environment to prevent condensation. Drain pump is equipped as standard accessory with 700mm lift This comes with a condensate water drain pump which can pump water up to 700mm higher from drain pipe outlet. Safety float is incorporated to monitor water level. Easy maintenance 700mm Quick and easy to install Just 246mm high. Installable in tight ceiling spaces. Panel-hook mechanism This feature enables the installer to work with both hands as the panel can be hung on the. Easier to maintain The condition of the drain pan and drain water can be checked by removing the drain plug and intake grille. Just open the intake grille! *246mm * 246mm high with FCRN50/60/71 * 288mm high with FCRN125/140 All models can be installed without using lifter because of the light weight. Detachable corner For the ease and flexibility of installation, this is designed with 4 detachable corners where installer is able to fit their hand in to adjust hanging hook and perform drain leakage check. Position of connecting pipe and drain hose In order to create more space for installer to work on connection pipe of indoor, the connection pipe of gas and liquid are located further from each other and purposely not align to hanging hook. To enhance the convenience of installation, drain hose location is relocated to another side of cassette (not same side with connection pipe). Easy accessible control box Control box of this can be accessed directly from the intake grille for ease of installation and servicing process. Simple step to change fan motor Without removing panel, it can be easily accessed and service to fan motor Reduced troubleshooting and servicing time Simple steps: control box fan cover blower fan fan motor Options required for specific operating environments Fresh air intake kit Using this kit*, a duct can be fitted to increase the intake of outdoor air. Knock-out hole The built-in knock-out hole are available for fresh air intake or branch duct. Drain plug Self-diagnosis function This intelligent feature helps to detect faults or malfunctioning in the system and give user a warning by blinking of the LED light or display error code on wired controller. Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally. 05 06

Duct Connection Standard Static Pressure Type Thin, lightweight indoor makes delivery and installation easy With a height of only 261mm, installation is possible even in buildings with narrow ceiling spaces. 261mm FDMRN50/60/71/100AXVL, 125/140AXVL9 (standard static) Flexibility in system design The offers fan motor that can operate up to 3 speeds, thus providing choices of external static pressure for designing ducting system. Double protection drainage system The primary drain pan is designed with high thermal insulation material and moulded in gradient for better condensate water drainage. The extra secondary drain pan built in to the standard offers extra protection against possible water leaking problems. Two selectable temperature sensors Both indoor and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set at the or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians. * Temperature-sensor on indoor must be used when the air conditioner is controlled from another room. ** Wireless remote controller does not have a temperature-sensor. High/Medium/Low High setting provides maximum reach while low setting minimises drafts. Primary drain pan Polystyrene (PS) with High Impact Polystyrene (HIPS) cover Secondary drain pan with insulation Wired controller: BRC51A62 * supplied with * optional Wireless controller: BRC52A62 Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening) When air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms. COMFORT CLEANLINESS WORK & SERVICING CONTROL FEATURES OTHERS Programme Dry Two selectable temperature sensor Weekly scheduled timer Washable saranet filter Pre-charged for up to 7.5m Self diagnosis Auto random restart Group control by Network Interface Module (NIM) External command control using BAG Anti corrosion treated heat exchangers *1 *1 *1 Applicable when wired controller is used. 07 08

Ceiling Suspended Type FHRN100AXVL Far and high air flow Far air flow distance with high air flow ensuring the spaces of the room to be cooled down rapidly to the set temperature. Two selectable temperature sensors Both indoor and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set at the or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians. * Temperature-sensor on indoor must be used when the air conditioner is controlled from another room. ** Wireless remote controller does not have a temperature-sensor. High/Medium/Low High setting provides maximum reach while low setting minimises drafts. Operation starts when the preset time of the on timer elapses and stops when the preset time of the off timer elapses. Easy Installation FHRN140AXVL9 Installation flexibility for freedom of design Uniform height and depth. Compact design for small-capacity models to meet tighter dimensional constraints. Easy Maintenance Easy-clean surfaces It is easy to wipe dirt off the surfaces of the. Ease of maintenance For all maintenance tasks, access is from bottom surface. Wired controller: BRC51A62 Wireless controller: BRC52A62 * optional * supplied with COMFORT CLEANLINESS WORK & SERVICING CONTROL FEATURES OTHERS Programme Dry Two selectable temperature sensor Weekly scheduled timer Washable saranet filter Pre-charged for up to 7.5m Self diagnosis Auto random restart Group control by Network Interface Module (NIM) External command control using BAG Anti corrosion treated heat exchangers *1 *1 *1 Applicable when wired controller is used. 09 10

Floor Standing Type Auto-swing mode This uses its automatic horizontal swing louver to spread comfortable air flow to cool every corner of the room. Its vertical louvers are adjusted manually to match different interior spaces and partition as well as to avoid direct airflow. Operation starts when the preset time of the on timer elapses and stops when the preset time of the off timer elapses. Powerful operation New powerful operation boosts airflow to maximum volume for a 20-minute period with highest fan speed. After this, the automatically returns to its previous settings. FVRN71/100AXVL, 125/140AXVL9 Auto horizontal swing Manual setting of vertical airflow louvers on/off switch The can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not charged. User-friendly controls The comes with a stylish black control panel with white LED light for clear display. It comes with a keylock function to prevent setting change from unauthorised personnel. Off state On state White display lights up to indicate modes and temperature settings when switched on Easy maintenance Safety clip The safety clip feature allows users to remove the washable saranet filter with ease during maintenance. At the same time, it also acts as a safety feature to prevent the users from reaching into the electrical and mechanical components. Keylock icon displayed when activated Keylock function: Activation / deactivation of keylock by pressing SWING and TURBO together for 5 seconds Safety clip Wired controller: BRC51A62 Wireless controller: BRC52A62 * optional * supplied with Far air flow The Daikin floor standing is able to achieve air flow distance as far as 25m (size 160) which is about the size of a basketball court. V_r (m/s) Global 2.44 1.22 0.00 Additionally, this is incorporated with infrared sensor for usage with wireless controller which is supplied with the. Thus, it can be controlled using wireless controller for greater flexibility. Space for water drain pump There is a space in the below the fan that allows users to install an external condensate water pump. * The condensate water drain pump is separately purchased and field installed. Auto swing Programme Dry COMFORT CLEANLINESS WORK & SERVICING CONTROL FEATURES Two selectable temperature sensor Weekly scheduled timer *1 *1 *1 Applicable when wired controller is used. Washable saranet filter Pre-charged for up to 7.5m Self diagnosis Auto random restart 25m Group control by Network Interface Module (NIM) External command control using BAG OTHERS Anti corrosion treated heat exchangers Two selectable temperature sensors Both indoor and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set at the or, to further improve comfort level, closer to the target area at the wired remote control. This feature must be set during commissioning by the technicians. * Temperature-sensor on indoor must be used when the air conditioner is controlled from another room. ** Wireless remote controller does not have a temperature-sensor High/Medium/Low High setting provides maximum reach while low setting minimizes drafts. Piping Floor standing Condensate water drain pump 11 12

Wireless controller BRC52A62 Controller 6 7 8 9 10 11 1 2 3 4 5 1 2 3 4 5 Glow-in-the-dark on/off switch Fan speed selection: Low, Medium, High, Auto Temperature setting: Up & down Sleep mode function Off timer setting 6 7 8 9 10 11 Vertical auto-swing Selectable mode: Cool, Dry, Fan Turbo function Quiet function On timer setting Real time clock RR50/60AGXVL RR71AGXVL RR125/140AGXTL9 Wired controller BRC51A62 Fitted with wide inlet fan Fully shaped aerodynamic propellers are designed to push air with a large wing surface, providing both high blow volume and quiet operation with turbulence. Pre-charged for up to 7.5 metres Model Max. piping length, m Max. piping elevation, m RR50A RR60A RR71A RR100A RR125A RR140A 30 50 50 15 25 30 7 8 9 10 11 1 2 3 4 5 6 1 2 3 4 5 6 Real time clock and day display Temperature operate in C and F Swing function Quiet function Sleep function On/off switch 7 8 9 10 11 Turbo function Cool, Dry, Fan mode Delay timer (1 or 2 hours) 7-days programmable timer Low, Medium, High, Auto fan speed Wide inlet fan Durability The is covered with corrosion-proof galvanized steel to enhance its durability. Heat exchange fins are provided with anti-corrosion treatment. Wired controller BRC51A62 can directly be connected to the s main board to start operating without extra setting or modification. It also has a built-in temperature sensor that enables temperature sensing closer to target area for improved comfort (no settings required to activate the handset temperature sensor). IR receiver on wired handset received the signal Signal sent from wireless handset 13 14

Network controls Network controls Simple system that provides flexibility of controls Sequential control by Sequential Network Interface Module () Group control by Network Interface module (NIM) Control Pattern For simultaneous control of up to 16 indoor s NIM NIM Remote Controls NIM NIM Control two s of air conditioner in a master and slave system, operating at alternate sequence of preset hours (3/4/5/7/9/11/12 hours), controlled by a single BRC51A62 controller. The controls consist of: Mainboard Control panel (BRC51A62) controller Communication bus The is suitable in environment requiring 24-hours air conditioning, such as server room, room containing critical electronics equipment, laboratories, telecommunication towers, railway switching centre and 24-hours shoplets. It also extends the operating lifetime of existing air conditioning s. Preset Switching Time: 3 hours Sequential control by Sequential Network Interface Module () For sequential control of 2 indoor s at alternate sequence of pre-set hour ON OFF Control by external command using BAG Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room. BAG BAG BAG BMS Group control by Network Interface Module (NIM) After 3 hours The NIM group controls consist of: Mainboard Mainboard Control panel (BRC51A62) NIM controller Communication bus OFF ON NIM controller NIM utilizes master-slave configurations. One master can control up to 15 slave s in a group. The master operates in conjunction with a control panel. Any settings done via the control panel connected to the master overwrite the settings of its slave s. Slave s can be operated with or without control panel. If a slave is operating with a control panel, its settings can be changed without following its master s. DIP switch setting for group and address Automatic detection of control panel Error codes and error s ID indication on control panel Supported configurations of NIM: Master Slave BRC51A62 BRC52A62 When the operating is faulty, the standby automatically takes over. Other features of : Auto restart feature with last state settings. Error indication via error code display on the control panel. Pre-set operation hours via DIP switch. Maximum point to point distance of 1000m. 15 16

Specification Specification Ceiling cassette 3x3 Model Decorative panel Nominal cooling capacity Nominal total input power Nominal running current EER Power Supply Airflow (H/M/L/Q) Sound pressure level (H/M/L/Q) Indoor Piping connections Sound pressure level Max. Inter piping length Max. Installation level difference 50 60 71 100 125 FCRN50AXVL FCRN60AXVL FCRN71AXVL FCRN100AXVL FCRN125AXVL9 RR50AGXVL RR60AGXVL RR71AGXVL RR125AGXTL9 BC50F2XWA Btu/hr 18500 24000 29500 36000 48000 kw 5.42 7.03 8.65 10.55 14.07 W 1730 2400 3130 3700 5100 A 7.9 11.0 14.3 16.8 14.8 W/W 3.13 2.93 2.76 2.85 2.76 V/Ph/Hz 220/1/60 220/1/60 220/1/60 220/1/60 220/3/60 cfm 730/620/510/360 840/700/560/440 890/760/620/490 1120/1030/890/760 1120/1030/890/760 db(a) 39/35/33/30 41/38/36/34 43/40/38/37 48/45/41/37 49/46/42/38 Unit mm 246x840x840 246x840x840 246x840x840 288x840x840 288x840x840 With decoration panel mm 301x950x950 301x950x950 301x950x950 343x950x950 343x950x950 Unit kg 22 22 22 25 25 Decoration panel kg 27 27 27 30 30 db(a) 50 50 57 61 66 mm 651x855x328 651x855x328 753x855x328 852x1030x400 852x1030x400 kg 43 43 57 71 87 Liquid (Flare) Inch ø1/4" ø1/4" ø3/8" ø3/8" ø3/8" Gas (Flare) Inch ø1/2" ø5/8" ø5/8" ø5/8" ø5/8" m 30 30 50 50 50 m 15 15 25 30 30 Floor standing Model Nominal cooling capacity Nominal total input power Nominal running current EER Power Supply Indoor Airflow (H/M/L/Q) Sound pressure level (H/M/L) Sound pressure level Piping connections Max. Inter piping length Max. Installation level difference 71 100 125 140 FVRN71AXVL FVRN100AXVL FVRN125AXVL9 FVRN140AXVL9 RR71AGXVL RR125AGXTL9 RR140AGXTL9 Btu/hr 29000 36000 48000 56000 kw 8.50 10.55 14.07 16.41 W 3130 3800 5000 6240 A 13.7 17.3 14.5 18.8 W/W 2.72 2.78 2.81 2.63 V/Ph/Hz 220/1/60 220/1/60 220/3/60 220/3/60 cfm 675/625/530 1035/945/845 1035/935/835 1170/1085/985 db(a) 44/42/39 49/47/44 50/48/46 54/53/51 mm 1850x600x270 1850x600x350 1850x600x350 1850x600x350 kg 42 45 48 51 db(a) 57 61 66 66 mm 753x855x328 852x1030x400 852x1030x400 852x1030x400 kg 57 71 87 101 Liquid (Flare) Inch ø3/8" ø3/8" ø3/8" ø3/8" Gas (Flare) Inch ø5/8" ø5/8" ø5/8" ø3/4" m 50 50 50 50 m 25 30 30 30 Duct connection standard static pressure type Model Nominal cooling capacity Nominal total input power Nominal running current EER Power Supply Indoor Airflow (H/M/L/Q) External static pressure (H/M/L) Sound pressure level (H/M/L) Sound pressure level Piping connections Max. Inter piping length Max. Installation level difference 50 60 71 100 125 140 FDMRN50AXVL FDMRN60AXVL FDMRN71AXVL FDMRN100AXVL FDMRN125AXVL9 FDMRN140AXVL9 RR50AGXVL RR60AGXVL RR71AGXVL RR125AGXTL9 RR140AGXTL9 Btu/hr 18500 23500 29000 36000 48000 56000 kw 5.42 6.89 8.50 10.55 14.07 16.41 W 1730 2400 3330 4000 5520 6590 A 7.9 11.0 15.3 18.2 15.6 19.5 W/W 3.13 2.87 2.55 2.64 2.55 2.49 V/Ph/Hz 220/1/60 220/1/60 220/1/60 220/1/60 220/3/60 220/3/60 cfm 590/520/320 690/570/440 900/830/640 1250/980/780 1540/1280/1100 1580/1330/1180 Pa 50 50 100 100 100 100 db(a) 40/38/33 42/40/39 47/45/42 50/47/43 51/48/46 52/50/47 mm 261x1065x411 261x1200x411 378x929x541 378x1045x541 378x1299x541 378x1499x541 kg 24 26 42 44 50 56 db(a) 50 50 57 61 66 66 mm 651x855x328 651x855x328 753x855x328 852x1030x400 852x1030x400 852x1030x400 kg 43 43 57 71 87 101 Liquid (Flare) Inch ø1/4" ø1/4" ø3/8" ø3/8" ø3/8" ø3/8" Gas (Flare) Inch ø1/2" ø5/8" ø5/8" ø5/8" ø5/8" ø3/4" m 30 30 50 50 50 50 m 15 15 25 30 30 30 Ceiling suspended 100 125 140160 Indoor FHRN100AXVL FHRN125AXVL FHRN140AXVL9 Model FHRN160AXVL RR125AGXVL RR140AGXTL9 RR160AGXTL Btu/hr 35000 56000 Nominal cooling capacity Btu/hr 35000 56000 kw 10.26 16.41 kw 10,26 16,41 Nominal total input power W 3800 6240 Nominal total input power 3800 6240 Nominal running current A 17.3 18.8 Nominal running current 17,3 18,8 EER W/W 2.70 2.63 EER Power Supply V/Ph/Hz W/W 220/1/60 2,70 220/3/60 2,63 Power Supply Airflow (H/M/L) V/Ph/Hz cfm 1107/999/751 220/1/60 1550/1380/1000 220/3/60 Indoor Sound pressure level (H/M/L) db(a) 49/46/43 56/54/51 Dimensions Airflow (H/M/L) (HxWxD) mm cfm 235x1903x680 1107/999/751 285x1903x680 1550/1380/1000 Machine Sound pressure weight level (H/M/L) db(a) kg 49/46/43 52 56/54/51 70 Sound Dimensions pressure (HxWxD) level db(a) mm 235x1903x680 61 285x1903x680 66 Dimensions (HxWxD) mm kg 852x1030x400 852x1030x400 70 Machine Sound pressure weight level db(a) kg 71 61 10166 Liquid (Flare) Inch mm 852x1030x400 ø3/8" 852x1030x400 ø3/8" Piping connections Gas (Flare) Inch kg ø5/8" 71 ø3/4" 101 Max. Inter piping length Liquid (Flare) Inch m ø3/8" 50 50 ø3/8" Piping connections Max. Installation level difference Gas (Flare) Inch m ø5/8" 30 30 ø3/4" Max. Inter piping length m 50 50 Max. Installation level difference m 30 30 Rated cooling capacities are based on the following conditions: Indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length: 7.5m 17 18