Photovoltaic Mercury Cadmium Telluride Detectors

Similar documents
Indium Gallium Arsenide Detectors

The J22 and J23 series are high performance InGaAs detectors operating over the spectral range

Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions

Instruction Manual ID-442 Infrared Detector 442-1A Temperature Controller Preamplifier

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

Room Temperature MWIR FPAs: Return of the Lead Salts?

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

Catalogue Photonic Solutions Ltd

818 Series Low-Power Detectors

IR detectors user's guide

TECHNICAL INFORMATION SD-12 Characteristics and use of infrared detectors

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

Optical Sensor (2A) Optical Sensor Type Optical Sensor Characteristics. Young Won Lim 9/12/09

MicroSL Silicon Photomultiplier Detectors

APPLICATION NOTE. 1. Introduction Application Considerations

XPIN -XT X-ray Detector Operation Manual

Cooled Butterfly 980nm Pump Laser Module

Temperature dependent Components within the Pyroelectric Detector

INFRARED COMPONENTS.

Spectrum Detector, Inc.

The new generation Teledyne NIR detectors for the SNAP/JDEM mission spectrograph.

The Art and Science of Being Cool

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

Customization of Optoelectronic Detectors Part Two in a Six-Part Series

dewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants.

G155PU001S. Pigtailed 14-PIN DIL Laser Diode with TEC. FLMS Min. Typ. Max.

New IR-detectors pig-tailed with IR-fibers

Understanding total measurement uncertainty in power meters and detectors

IR detection module VPAC-1000F user's guide

Measurement of Light. Photosensors

Selection guide - September Covering a broad spectral range in the infrared region HAMAMATSU PHOTONICS K.K.

Technical Data Sheet 5mm Infrared LED, T-1

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 1

Electro Optical Components, Inc Skylane Boulevard, Santa Rosa, CA Toll Free: 855-EOC

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

Date: Wednesday, January 31, 2018 Time: 8:30 am 5:00 pm Location: Moscone West (Room 2018, Level 2)

On-chip optical detectors in Standard CMOS SOI

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

HOA0880-T51. Representative photograph, actual product appearance may vary.

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Dated 15-Dec-2000; J. Schilz, subject to change

Lasers Technical Seminar at Bruno Events Center on March 27 th, Next generation of SPADs - Single Photon Avalanche Detectors

Technical Data Sheet 1.5mm Side Face Infrared LED

LECTURE 11. Dr. Teresa D. Golden University of North Texas Department of Chemistry

NIDS Dust sensor ED-N-DS-1408

NX7363JB-BC. Data Sheet R08DS0009EJ0200 Rev.2.00 LASER DIODE. Sep 19, 2010 DESCRIPTION FEATURES

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

The FEL Facility Optical Diagnostics and FEL Characterization

Product Specification

Models S310 & S310D Laser Power and Energy Meters Setup and Operating Procedures

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

COMPACTNESS 34.1 PERFORMANCE ANTICIPATION

High Throughput Large Area Silicon Drift Detectors

arxiv:astro-ph/ v1 17 Aug 2000

SOLAR CELL PRODUCTION REQUIRES EFFECTIVE METROLOGY

Dust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12

Power Meters Energy Meters

Instruction Manual. gray Housed Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Fiber Optics and Liquid Level Sensors Line Guide

COMPACTNESS 34.1 PERFORMANCE ANTICIPATION

to get there. together. Infrared Sources Swiss made

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

MULTI-FUNCTION InGaAs DETECTOR FOR SWIR IMAGING

Medipix PCBs and mechanics

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

MEAS EMITTER ASSEMBLY ELM-4000 SERIES

Speed and Frequency Seite 1 von 7

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Instruments Designed for POF & Fibre Optic Cable Testing

2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web:

Autonomous Vehicles. Pushing the Boundaries of Sensors and Emitters Reader Issue Beacons of the Industry Annual Reader Poll

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

Defense Technical Information Center Compilation Part Notice

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Chemistry Instrumental Analysis Lecture 4. Chem 4631

Catalog Pyroelectric & Multispectral Detectors uncooled highly stable high performance highest quality. multi color.

T2SL technology for Mid-IR detectors

Characterization of High Speed Optical Detectors for Purpose of OM4 Fibre Qualification: Selective Mode Detection

UNCOOLED MICROBOLOMETER DETECTOR : RECENT DEVELOPMENTS AT ULIS

Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs

Advantages / Characteristics

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

HM1520LF Relative Humidity Module

Design of Classroom Intelligent Lighting System Based on SCM. Jiale Zheng1, a

LM-80V , h V LM-30V h V

II-VI SUWTECH INC.

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Technical Data Sheet 1.6mm Side Looking Phototransistor

OPERATOR S MANUAL. Infinity Series Ceramic CO2 Laser: Models 15XXSB

ICS Integrated Cryocooling System

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

THE PLACE TO BE FOR AUVERGNE RHÔNE-ALPES COMMITTED FRENCH TECH MEMBER

Transcription:

Photovoltaic Mercury Cadmium Telluride s Teledyne Judson Technologies LLC Commerce Drive Montgomeryville, PA 89 USA Tel: -8-9 Fax: --7 Visit us on the web. ISO 9 Certified www.teledynejudson.com /

J9 PV MCT Operating Notes (. to. µm) General.E+.E+ -9C D* (Jones) J9 series detectors are high-quality HgCdTe (MCT) photodiodes for use in the nm to.µm spectral range. The equivalent circuit is a photon-generated current source Iph with parallel capacitance CD, shunt resistance RD, and series resistance RS. (Figure ) Figure ical D* vs Wavelength for room temperature and TE-, PV MCT,.8µm cutoff, mm, 8 FOV; FOV at -9C Figure Photodiode Equivalent Circuit -8C.E+ -C -C -C.E+ C.E+9.... Wavelength (um) Responsivity Cooling an MCT photodiode increases its shunt resistance which results in reduced noise and improved detectivity. Figures and show the relationship between detector temperature and detectivity (D*) as a function of wavelength. The D* plots in Figure are for a detector with an active size of mm, % cutoff wavelength at µm and operating from -C to -9C. The detectors are mounted on thermoelectric coolers (TEC) where one-stage (TE) is used for -C operation and subsequent stages (TE, TE and TE) are used to achieve lower temperatures. Similarly, Figure shows a series of plots for D* vs. wavelength for a detector with an active size of mm, % cutoff wavelength at.8µm and operating from room temperature (+C) to -9C. The field of view (FOV) is 8 except at -9C where the FOV is. Figure ical Spectral Response, PV MCT, µm cutoff, mm, TE-, 8 FOV..7. Responsivity (A/W) Temperature Effects Figures and show a typical spectral response for mm size, µm and.8µm cutoff, respectively. Please refer to Tables, and for further detector specifications for.8µm, µm and.µm wavelength cutoffs, respectively...8...9... Wavelength Figure ical D* vs Wavelength for TE-, PV MCT, µm cutoff, mm, 8 FOV, FOV @ -9C Figure ical Spectral Response, PV MCT,.8µm cutoff, mm, 8 FOV.E+.. Responsivity (A/W) D* (Jones) -9C -8C.E+ -C.9. -C. -C.E+9 Wavelength..... Wavelength (um) /

Thermoelectric Cooler Operation Advantages of Photovoltaic MCT Teledyne Judson offers a variety of convenient packages for room temperature and thermoelectrically (TE) cooled operation. ical power requirements for the TE, TE and TE coolers are shown in Figures 8, 9 and on page. The built in thermistor can be used to monitor or control the temperature. Figure shows typical thermistor resistance vs. temperature values. Sensitivity and cutoff wavelength are functions of temperature. temperature should be optimized for a particular application. Unlike the MCT photoconductors commonly used in the 7nm to.µm region, MCT photodiodes operate in the photovoltaic mode and can operate at zero bias. J9 detectors are a better choice for DC and low-frequency applications as they exhibit low /F noise characteristics as compared to PbS, PbSe and HgCdTe photoconductors. J9 detectors also offer superior pulse response for applications in monitoring and detecting high-speed pulsed lasers. They do not require a chopper and exhibit better linearity than photoconductive detectors. Figure ical Thermistor Curve Accessories Thermistor Resistance (K ) A thermoelectrically cooled detector requires a heat sink to dissipate the heat generated by the cooler, an amplifier to amplify the detector signal to a usable level and a temperature controller to hold the detector at a constant temperature. Teledyne Judson TE cooler accessories are designed to provide solutions for our customers. The CMAMP series is designed for customers that would like a fully integrated detector module. It includes heatsinking, detector signal amplification and temperature control. We also offer heat sink assemblies without preamps or temperature controllers. Please ask customer service for Product Bulletin PB for more information. Operating Circuit The recommended operating circuit for most applications is an operational amplifier in a negative-feedback transimpedance configuration (Figure 7) with up to.v reverse bias put across the detector. This reverse bias will increase the effective shunt impedance of the detector but will also increase the detector /F noise. Figure 7 ical Operating Circuit RF < V IDARK IS - Cooler / Preamplifier Recommendations Shunt Impedance Recommended Cooler Module Part to K CMAMP-TO-PA-LZ CMAMP-CN-PA-LZ 9 9 > K CMAMP-TO-PA-HZ CMAMP-CN-PA-HZ 99 99 CMAMP assembly includes heat sink, temperature controller and transimpedance amplifier for the J9TE packages. Vo = IS RF + Isc Vos /

Table..8µm Cutoff Room Temperature and Thermoelectrically Cooled PV MCT, One Through Four Stages (TE-) Shunt impedence Active Size Operating % Cutoff (Ohm) Diameter Temp. Wavelength Wavelength Responsivity Part (A/W) (mm) ( C) Model J9:.8-8C-RU J9:.8-8C-RM J9TE:.8-C-RU J9TE:.8-C-RM J9TE:.8-C-RU J9TE:.8-C-RM J9TE:.8-C-RU J9TE:.8-C-RM J9TE:.8-CN-RU J9TE:.8-CN-RM J9TE:.8-VN-RU J9TE:.8-VN-RM 8 7 9 TBA TBA............ - - - - - - -8-8 -9-9.8.8.8.8.8.8.8.8.8.8.8.8........................ 7.E+ 7.E+.E+.E+ 7.E+ 7.E+.E+.E+.E+7.E+.E+7.E+.E+.E+.E+.E+.E+.E+ 8.E+ 8.E+.E+7.E+.E+7.E+ Dark Current @ -.V (A) Max.E-.E-.E-7.E-.E-8.E-7.E-9.E-8.E-9.E-8.E-9.E-8.E-.E-.E-.E-.E-7.E-.E-8.E-7.E-8.E-7.E-8.E-7 D* (Jones) @ KHz.E+.E+ 7.7E+ 9.7E+.E+.7E+.7E+.9E+ 7.E+ 9.E+ 8.E+.E+.8E+.E+.E+.E+.9E+.7E+.9E+ 7.E+ 8.E+.E+ 8.E+.E+ All specs are for detector operation at V bias and 8 FOV unless otherwise specified. Maximum reverse bias voltage for all detectors is.v. Table..µm Cutoff Thermoelectrically Cooled PV MCT, One Through Four Stages (TE-) Model J9TE:-C-RU J9TE:-C-RM J9TE:-C-RU J9TE:-C-RM J9TE:-C-RU J9TE:-C-RM J9TE:-CN-RU J9TE:-CN-RM * J9TE:-VN-RU * J9TE:-VN-RM Shunt impedence Active Size Operating % Cutoff (Ohm) Diameter Temp. Wavelength Wavelength Responsivity Part.. (A/W) (mm) ( C) 8 7 8 7.......... - - - - - - -8-8 -9-9.......................7..9......E+.E+.E+.E+.E+.E+.E+.E+.E+.E+.E+.E+.E+.E+.E+.E+ 7.E+ 7.E+.E+.E+ Dark Current @ -.V (A) Max.E-.E-.E-.E-.E-.E-.E-.E-.E-.E-.E-.E- 8.E- 8.E-.E-.E-.E-.E- 8.E- 8.E- D* (Jones) @ KHz.E+9.E+9 7.E+9 7.E+9.E+.7E+.7E+.E+.8E+.8E+.E+9.7E+9.E+.E+.E+.E+.8E+.E+.E+.8E+ All specs are for detector operation at V bias and 8 FOV unless otherwise specified. * FOV. Maximum reverse bias voltage for all detectors is.v. Higher responsivity may be achieved at reverse bias. Table..µm Cutoff Thermoelectrically Cooled PV MCT, One Through Four Stages (TE-) Model Active Size Operating % Cutoff Diameter Temp. Wavelength Wavelength Responsivity Part.. (A/W) (mm) ( C) J9TE:.-C-RU J9TE:.-C-RM J9TE:.-C-RU 8 J9TE:.-C-RM 9 J9TE:.-C-RU J9TE:.-C-RM J9TE:.-CN-RU J9TE:.-CN-RM * J9TE:.-VN-RU * J9TE:.-VN-RM 9 All specs are for detector operation at Maximum reverse bias voltage for all Shunt impedence (Ohm). -...7.E+.E+. -....E+.E+. -...9.E+.E+. -....E+.E+. -... 8.E+.E+. -...8 8.E+.E+. -8....8E+.E+. -8....8E+.E+. -9....E+.E+. -9....E+.E+ V bias and 8 FOV unless otherwise specified. * FOV. detectors is.v. Higher responsivity may be achieved at reverse bias. Dark Current @ -.V (A) Max.E-.E-.E-.E-.E-.E-.E-.E-.E-.E-.E-.E-.E-.E-.8E-.8E-.E-.E-.E-.E- D* (Jones) @ KHz.E+9.8E+9.9E+9.9E+9.E+.E+.E+.E+.9E+.7E+.E+9.E+9 8.E+9 8.E+9.7E+.9E+.E+.E+.E+.E+ /

C/D Package CN Package. Thk AR Coated Sapphire Window. MAX. Top, Sealant. DIA.. Dia.. Clear Aperture Outer, Top Cap C: AR Coated Sapphire Window D: Sapphire Window. SQ.7 DIA. REF. Sealant.7 TYP Top,.. ±. MAX.8 ±..9 ±..9 8. REF. 7 Side View Pin No. Designation Sleeve Color Thermistor Cathode (-) White Yellow Anode (+) Green Cooler (-) Black Cooler (+) Red N/C Clear 7 N/C Clear 8 Thermistor Yellow 7S Package 8C Package Figure 8 Temperature vs TE Cooler Current Figure 9 Temperature vs TE Cooler Current Figure Temperature vs TE Cooler Current /

In addition to our Photovoltaic MCT product line, Teledyne Judson Technologies offers a wide range of high performance standard, custom and space qualified detector products and accessories. Germanium detectors and arrays Indium Arsenide detectors and arrays Indium Antimonide detectors and arrays Mercury Cadmium Telluride detectors and arrays Lead Selenide detectors and arrays Lead Sulfide detectors and arrays Dewars, backfill and vacuum packages Thermoelectric, Joule Thomson and closed cycle linear and rotary coolers Preamplifiers Temperature controllers and readout electronics Please contact us for more information on these products at -8-9 or on the web at www.teledynejudson.com. Commerce Drive Montgomeryville, PA 89 USA Tel: -8-9, Fax: --7 www.teledynejudson.com November, /