MONO & MULTI SPLIT AIR CONDITIONERS

Similar documents
Just feel well. 2017/2018 Air conditioning

Now with WiFi as standard Find out more at

Attractive, slim, versatile & WITHOUT OUTDOOR UNIT

HEAT PUMPS SiOS SYSTEM TERMINAL UNITS UNICO FIXED AIR CONDITIONERS PORTABLE AIR CONDITIONER AIR COOLER VMC DEHUMIDIFIERS HUMIDIFIERS

2017/2018 Air conditioning

Inverter Ducted XPower 42QSS

A2A, A2W & DHW HEAT PUMP & AIR COND

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

Ducted inverter reverse cycle air conditioning

All you can do with iseries

Comfort. Health Clean. Saving. The new era in air conditioning. Multi-Split Systems

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

Comfort. Health Clean. Saving. The new era in air conditioning. Multi-Split Systems

2017 LINE UP MINI SPLITS CATALOG

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Minisplit Inverter Systems

PRODUCT LINE-UP Residential & Light Commercial air conditioners

A more comfortable, safe and sustainable world

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

Inverter Ducted Air Conditioners

2017 LINE UP MINI SPLITS CATALOG

Contents. Wall Mounted Nemesis Aria Passion Pro Omnia Life Portable Magic...

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Residential Air Conditioners 2013 CATALOGUE / B

AIR CONDITIONERS SPLIT TROPICAL RANGE. FLAT SPLIT - Heat & Cool T1 R410a AMD K BTU EAN: AMD K BTU EAN:

Inverter Ducted Air Conditioners

InverterFlex SerIeS InverterFlex Systems condition up to five rooms

2 &3-4 Head Multi System

Ductless Mini-Split Air Conditioners and Heat Pumps. Residential/Light Commercial Catalog 2015

SPLIT SYSTEM AND VRF SYSTEMS PRODUCT GUIDE

THE WORLD S MOST EFFICIENT HEAT PUMP

The future is in the air

Product Brochure Smart Power. Low Profile Ducted

InverterFlex SERIES InverterFlex Systems condition up to five rooms

Cozy Hi Wall Inverter Air conditioner

Product Brochure 2017

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard.

Cozy Hi Wall Inverter Air conditioner

HEAT PUMPS. Efficient Comfort For Every Season

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Mini-Split and Multi-Zone Air Conditioners and Heat Pumps. Residential/Light Commercial Catalog 2016

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

Smart Wi-Fi Technology. Control your room temperature easily from wherever you are Enjoy ideal conditions and great energy savings.

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

American Brand with Global Reach. Heat Pump Decorative Wall Mount Split Unit

Inverter console UFV system. Compact design and personalised air flow selection

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

Cozy Hi Wall Inverter Air Conditioner

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

Braemar superior range of reverse cycle air conditioning

The latest innovation in cool 7 YEAR 1 YEAR WARRANTY ON PARTS WARRANTY ON COMPRESSORS

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Hi - Wall Split Systems 12K - 18K - 24K

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Samsung Free Joint Multi Air Conditioning System

Ductless Split Systems Concealed Duct Heat Pumps

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

RESIDENTIAL MONO&MULTI 2015

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Technology DC Inverter = performance, comfort and saving R 410 A. >Several possible combinations : 3 outdoor units and 15 indoor units

Hansol Hi Wall Inverter Air Conditioner

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

COOLING, COMFORT AND CONVENIENCE

Pure Efficiency Meets Healthy Living NEW 2013

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

air-conditioner SPLIT SYSTEMS / FLooR STANDING / MoBILE / MoNo BLoCS

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

years Just feel well 2017/2018 Air conditioning

Mini-Split Single-Zone and Multi-Zone Air Conditioners and Heat Pumps. Residential Catalog 2018

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

Air Conditioners Heating & Cooling

Mini-Split and Multi-Zone Air Conditioners and Heat Pumps. Residential/Light Commercial Catalog 2016

Ductless Split Systems Ceiling Cassette Heat Pumps

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Heat Pump Air Conditioning Systems

Samsung Room Air Conditioning

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Residential and Light Commercial Ductless Systems Catalog

2016/2017. Air conditioning

Product Line Introduction. Karl Zhang Technical support engineer

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

AIR CONDITIONERS PROFESSIONAL CATALOGUE

Air to air heat pump range. Why Vaillant? because there is something in the air.

Hansol Hi Wall Inverter Heat Pump

Q Series. Inverter Split Systems

NEW FREE MULTI SYSTEM E Up to 5 indoor units with a single outdoor unit FREE MULTI SYSTEM E R410A GAS

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

Transcription:

MONO & MULTI SPLIT AIR CONDITIONERS

SINGLE SPLIT DCI INVERTER TECHNOLOGY Low Consumption Low Noise Level Precise temperature set ENERGY CLASS IR REMOTE Standby 0,5W 3 Sleep Curve Comfortable Cold Air Prevention Led Display Timer Intelligent Defrosting Auto Clean Turbo Button Self-Diagnosis Dehumidification Auto Restart Cold Plasma ifeel Energy Saving -15 C Cooling -20 C Heating X3 DC inverter series is highly efficient and provides immediate and continuous comfort with low energy consumption. Moreover, some technological features are designed to reduce peak consumption to improve the functioning at low temperatures. Inverter technology: low consumption, low noise, more precise temperature control ERP compliant; just 0.5 watt consumption in stand-by Compact & Linear Design, high-gloss pure white finishing Central very discreet display on the front panel Digital remote control with LCD display Different airflow settings; 4 fan speeds Programmable timer I feel: ensures the desired temperature in the precise place where you place the remote control Turbo Function Cold plasma air purification system Air sterilization with removing over 90% of bacteria Odors removal Improved air quality thanks to negative ions increasing Memory Function Comfortable Sleep mode Auto clean of the indoor heat exchanger Intelligent defrost: defrost process is not activated unnecessarily, allowing significant energy saving Cold draft prevention: it prevents cold air entering during the heating function Low Voltage start-up: low consumption at start-up, no impact on the use of other electrical appliances Self-diagnosis Optimized airflow in cooling and heating 2

Technical data MODEL (Indoor unit / Outdoor unit) X3I 27 (X3I 27 HL / X3I 27 SH) X3I 35 (X3I 35 HL / X3I 35 SH) kw 2,6 (0,45-3,23) 2,8 (0,45-4,1) 3,5 (0,6-3,96) 3,67 (0,6-5,13) BTU/h EER/COP (EN14511) 3,23 3,71 3,23 3,71 kw 2,6 2,6/2,8/2,6 3,5 3,0/3,8/3,0 (Average/Warmer/Colder) (EN14825) 6,1 4,0/5,1/3,2 6,1 4,0/5,1/3,2 Energy efficiency class A++ A+/A+++/B A++ A+/A+++/B Annual energy consumption C/H(Avarage/Warmer/Colder) kwh/annum 149 910/769/1706 201 1050/1043/1969 Air flowrate Indoor (sh.-h.-m.-l.) m³/h 560-490-430-330 660-540-460-330 Dehumidification l/h 0,8 1,4 Fan speeds (Indoor / Outdoor) n 4/2 4/2 Sound pressure Indoor (sh.-h.-m.-l.) db(a) 39-36-32-26 42-39-33-26 Sound pressure Outdoor (h.) db(a) 52 53 Sound power Indoor (sh.-h.-m.-l.) db(a) 55-52-44-38 57/53/45/42 Sound power Outdoor (h.) db(a) 61 62 Power supply V/Ph/Hz 230/1/50 230/1/50 Power input kw 0,805 0,755 1,084 0,989 Compressor type Rotary DC Inverter Rotary DC Inverter Refrigerant type R410A R410A Refrigerant charge kg/t.co2 eq. 0,7/1,46 0,85/1,77 Liquid pipe diameter mm (") 6,35(1/4") 6,35(1/4") Gas pipe diameter mm (") 9,52(3/8") 9,52(3/8") Max. pipe lenght with gas standard charge m 5 5 Max. pipe lenght m 15 20 Additional refrigerant charge g/m 20 20 Max. height between units (Outdoor on top) m 10 10 Max. height between units (Indoor on top) m 10 10 Net dimension Indoor (H./W./D.) mm 275x790x200 289x845x209 Net dimension Outdoor (H./W./D.) mm 540x776x320 540x776x320 Net weight Indoor / Outdoor Kg 9/28 10/29 MODEL (Indoor unit / Outdoor unit) X3I 52 (X3I 52 HL / X3I 52 SH) X3I 64 (X3I 64 HL / X3I 64 SH) kw 5,13 (1,26-6,6) 5,28 (1,12-6,8) 6,7 (2,0-8,2) 7,25 (2,0-8,5) BTU/h 18000 18000 24000 24000 EER/COP (EN14511) 3,25 3,74 3,25 3,74 kw 5,1 4,1/5,3/6,2 6,7 6,4/7,1/6,4 (Average/Warmer/Colder) (EN14825) 6,1 4,0/5,4/3,1 6,3 4,0/5,1/2,8 Energy efficiency class A++ A+/A+++/B A++ A+/A+++/C Annual energy consumption kwh/annum 293 1435/1374/4200 373 2240/1949/4800 Air flowrate Indoor (sh.-h.-m.-l.) m³/h 800-720-610-520 1150-1050-950-850 Dehumidification l/h 1,8 2,4 Fan speeds (Indoor / Outdoor) n 4/2 4/2 Sound pressure Indoor (sh.-h.-m.-l.) db(a) 46-42-39-36 48-45-42-39 Sound pressure Outdoor (h.) db(a) 56 60 Sound power Indoor (sh.-h.-m.-l.) db(a) 58-54-51-48 64-59-56-53 Sound power Outdoor (h.) db(a) 63 68 Power supply V/Ph/Hz 230/1/50 230/1/50 Power input kw 1,58 1,41 1,875 1,945 Compressor type Rotary DC Inverter Rotary DC Inverter Refrigerant type R410A R410A Refrigerant charge kg/t.co2 eq. 1,3/2,71 1,9/3,97 Liquid pipe diameter mm (") 6,35(1/4") 6,35(1/4") Gas pipe diameter mm (") 12,7(1/2") 15,88 (5/8") Max. pipe lenght with gas standard charge m 5 5 Max. pipe lenght m 25 25 Additional refrigerant charge g/m 20 20 Max. height between units (Outdoor on top) m 10 10 Max. height between units (Indoor on top) m 10 10 Net dimension Indoor (H./W./D.) mm 300x970x224 325x1078x246 Net dimension Outdoor (H./W./D.) mm 700x955x396 700x955x396 Net weight Indoor / Outdoor Kg 13,5/45 17/53 Data declared in compliance with EU Regulation no. 206/2012, as regards to Ecodesign requirements for air conditioners and comfort fans, and EU Regulation no. 626/2011, concerning the energy labelling of air conditioners, and tested according to standard EN14825. OPERATING RANGE (outdoor temperature) Cooling mode: from -15 C to +43 C Heating mode: from -20 C to +24 C Temperature setting range: 16-30 C 3

MULTISPLIT DCI WIDE RANGE SEVERAL MATCHINGS ENERGY CLASS Capacity range from 14 to 42000 BTU/h Widely used in residential houses, hotel, Possibility of choice among different DC INVERTER TECHNOLOGY Low Consumption Low Noise Level Precise temperature control LOW AMBIENT COOLING types of indoor units, meeting any need business offices (105 Model) All models can work up to -15 C in FREE MATCH cooling mode, except only for model 105 (-5 C) TURBO W Timer 24h Weekly Timer R410A Easy Maintenance Turbo function High Efficiency Auto-diagnosis Intelligent Defrosting Auto Restart Memory V Child Lock Btu/h 9000 Energy Saving 12000 Wide Voltage Low voltage Start-up 18000 24000 HI-WALL X3I HL CASSETTE X3I AS DUCTED X3I SD FLOORCEILING X3I FC CONSOLE X3I AF 4 INDOOR UNIT MODELS Btu/h X3I 27 HL - X3I FC27HL - X3I AF27HL 9000 X3I 35 HL - X3I AS35HL - X3I SD35HL X3I FC52HL - X3I AF35HL 12000 X3I 52 HL - X3I AS52HL - X3I SD52HL X3I FC52HL - X3I AF52HL 18000 X3I 64 HL 24000

Controllers INDOOR UNIT TYPES CONTROLLERS HI-WALL DUCTED CASSETTE FLOOR/ CEILING CONSOLE DUAL/TRIAL SPLIT Type IU IU X3MI 41SH Type IU IU X3MI 52SH Type IU IU IU X3MI 61SH 9000 18000 12000 18000 9000 12000 12000 Type IU IU IU 9000 18000 12000 18000 X3MI 71SH 18000 18000 9000 12000 18000 12000 12000 QUADRI SPLIT Matchings Type IU IU IU IU X3MI 80SH 9000 18000 12000 18000 18000 18000 9000 12000 18000 18000 12000 18000 18000 18000 12000 5

Matchings QUADRI SPLIT Type IU IU IU IU X3MI 105SH 9000 18000 9000 24000 12000 18000 12000 24000 18000 18000 18000 24000 24000 24000 9000 12000 18000 24000 12000 18000 24000 9000 18000 18000 9000 18000 24000 12000 18000 24000 12000 18000 18000 12000 18000 24000 9000 18000 9000 24000 12000 18000 18000 18000 12000 18000 PENTA SPLIT Type IU IU IU IU IU X3MI 120SH 9000 18000 9000 24000 12000 18000 12000 24000 18000 18000 18000 24000 24000 24000 9000 12000 18000 24000 12000 18000 24000 9000 18000 18000 9000 18000 24000 12000 18000 24000 12000 18000 18000 12000 18000 24000 12000 24000 24000 18000 18000 18000 18000 18000 24000 9000 18000 9000 24000 12000 24000 18000 18000 18000 18000 12000 18000 12000 18000 9000 12000 18000 12000 12000 6

Technical data - Outdoor units TDOOR MODEL - DUAL SPLIT X3MI 41SH X3MI 52SH kw 4,1 (2,05-4,40) 4,4 (2,49-5,42) 5,2 (2,14-5,84) 5,4 (2,58-5,51) BTU/h 14000 15000 17750 18430 EER/COP (EN14511) 3,42 3,73 3,59 3,48 kw 4,1 3,8 5,2 5,0 (Average/Warmer/Colder) 6,1 4,0 6,3 4,0 Energy efficiency class A++ A+ A++ A+ Annual energy consumption C/H(Avarage/Warmer/Colder) kwh/annum 235 1330 288 1750 Numero minimo-max unità interne collegabili no. 2 2 Air flowrate m³/h 2600 3200 Fan speeds Outdoor n 2 2 Sound pressure Outdoor (sh.-h.-m.-l.) db(a) 55 56 Sound power Outdoor (h.) db(a) 62 62 Power supply V/Ph/Hz 230/1/50 230/1/50 Power input kw 1,2 1,18 1,45 1,55 Compressor type Rotary DC Inverter Rotary DC Inverter Refrigerant type R410A R410A Refrigerant charge kg/t.co 2 eq. 1,4/2,92 1,6/3,34 Liquid pipe diameter mm (") 6,35(1/4") 6,35(1/4") Gas pipe diameter mm (") 9,52(3/8") 9,52(3/8") Min./Max. pipe lenght with gas standard charge m 3-10 3-10 Max. pipe lenght with additional charge m 20 20 Additional refrigerant charge g/m 20 20 Max. height between units (Outdoor on top) m 5 5 Max. height between units (Indoor on top) m 5 5 Net dimension Outdoor (H./W./D.) mm 596x899x378 700x955x396 Net weight Kg 43 51 TDOOR MODEL - TRIAL SPLIT X3MI 61SH X3MI 71SH kw 6,1 (2,2-7,33) 6,5 (3,61-8,5) 7,1(2,29-8,5) 8,5 (3,66-8,79) BTU/h 20820 22180 24230 29000 EER/COP (EN14511) 3,19 3,76 3,26 3,73 kw 6,1 5,8 7,1 7,0 (Average/Warmer/Colder) 6,1 4,0 6,1 4,0 Energy efficiency class A++ A+ A++ A+ Annual energy consumption C/H(Avarage/Warmer/Colder) kwh/annum 350 2030 407 2450 Numero minimo-max unità interne collegabili no. 2-3 2-3 Air flowrate m³/h 3200 4000 Fan speeds Outdoor n 2 2 Sound pressure Outdoor (sh.-h.-m.-l.) db(a) 56 58 Sound power Outdoor (h.) db(a) 65 65 Power supply V/Ph/Hz 230/1/50 230/1/50 Power input kw 1,91 1,73 2,18 2,28 Compressor type Rotary DC Inverter Rotary DC Inverter Refrigerant type R410A R410A Refrigerant charge kg/t.co 2 eq. 2,2/4,59 2,2/4,59 Liquid pipe diameter mm (") 6,35(1/4") 6,35(1/4") Gas pipe diameter mm (") 9,52(3/8") 9,52(3/8") Min./Max. pipe lenght with gas standard charge m 3-30 3-30 Max. pipe lenght with additional charge m 60 60 Additional refrigerant charge g/m 20 20 Max. height between units (Outdoor on top) m 10 10 Max. height between units (Indoor on top) m 10 10 Net dimension Outdoor (H./W./D.) mm 700x955x396 790x980x427 Net weight Kg 62 68 Data declared in compliance with EU Regulation no. 206/2012, as regards to Ecodesign requirements for air conditioners and comfort fans, and EU Regulation no. 626/2011, concerning the energy labelling of air conditioners, and tested according to standard EN14825. OPERATING RANGE mod. 41-52-61-71 (outdoor temperature) Cooling mode: from -15 C to +43 C Heating mode: from -20 C to +24 C Temperature setting range: 16-30 C 7

Technical data - Outdoor units TDOOR MODEL - QUADRI SPLIT X3MI 80SH X3MI 105SH kw 8,0 (2,29-10,26) 9,30 (3,66-10,26) 10,5 (2,1-11) 11(2,6-13) BTU/h 27300 31730 35830 37530 EER/COP (EN14511) 3,23 3,71 3,00 2,93 kw 8,0 7,0 10,5 10,5 (Average/Warmer/Colder) 6,1 4,0 5,50 3,80 Energy efficiency class A++ A+ A+ A Annual energy consumption C/H(Avarage/Warmer/Colder) kwh/annum 459 2450 668 3876 Numero minimo-max unità interne collegabili no. 2-4 2-4 Air flowrate m³/h 4000 5200 Fan speeds Outdoor n 2 2 Sound pressure Outdoor (sh.-h.-m.-l.) db(a) 58 57 Sound power Outdoor (h.) db(a) 65 67 Power supply V/Ph/Hz 230/1/50 230/1/50 Power input kw 2,54 2,49 3,50 3,75 Compressor type Rotary DC Inverter Rotary DC Inverter Refrigerant type R410A R410A Refrigerant charge kg/t.co 2 eq. 2,4/5,01 4,3/8,98 Liquid pipe diameter mm (") 6,35(1/4") 6,35(1/4") Gas pipe diameter mm (") 9,52(3/8") 9,52(3/8") Min./Max. pipe lenght with gas standard charge m 3-40 3-40 Max. pipe lenght with additional charge m 70 70 Additional refrigerant charge g/m 20 22 Max. height between units (Outdoor on top) m 10 15 Max. height between units (Indoor on top) m 10 15 Net dimension Outdoor (H./W./D.) mm 790x980x427 1103x1015x440 Net weight Kg 69 94 TDOOR MODEL - PENTA SPLIT X3MI 120SH Units Cooling Heating kw 12,1 (2,1-13,6 13 (2,6-14) BTU/h 41300 44360 EER/COP (EN14511) 3,37 3,66 kw nd>12kw nd>12kw (Average/Warmer/Colder) nd>12kw nd>12kw Energy efficiency class nd>12kw nd>12kw Annual energy consumption C/H(Avarage/Warmer/Colder) kwh/annum nd>12kw nd>12kw Numero minimo-max unità interne collegabili no. 2-5 Air flowrate m³/h 5500 Fan speeds Outdoor n 2 Sound pressure Outdoor (sh.-h.-m.-l.) db(a) 54 Sound power Outdoor (h.) db(a) 64 Power supply V/Ph/Hz 230/1/50 Power input kw 3,59 3,55 Compressor type Rotary DC Inverter Refrigerant type R410A Refrigerant charge kg/t.co 2 eq. 4,8/10,02 Liquid pipe diameter mm (") 6,35(1/4") Gas pipe diameter mm (") 9,52(3/8") Min./Max. pipe lenght with gas standard charge m 3-40 Max. pipe lenght with additional charge m 70 Additional refrigerant charge g/m 22 Max. height between units (Outdoor on top) m 15 Max. height between units (Indoor on top) m 15 Net dimension Outdoor (H./W./D.) mm 1103x1015x440 Net weight Kg 102 Data declared in compliance with EU Regulation no. 206/2012, as regards to Ecodesign requirements for air conditioners and comfort fans, and EU Regulation no. 626/2011, concerning the energy labelling of air conditioners, and tested according to standard EN14825. OPERATING RANGE mod. 80 (outdoor temperature) Cooling mode: from -15 C to +43 C Heating mode: from -20 C to +24 C Temperature setting range: 16-30 C 8 OPERATING RANGE mod. 105/120 (outdoor temperature) Cooling mode: from -5 C to +48 C Heating mode: from -15 C to +24 C Temperature setting range: 16-30 C

Technical data - Indoor units HI-WALL INDOOR UNITS X3I 27 HL X3I 35 HL X3I 52 HL X3I 64 HL Cooling Heating Cooling Heating Capacity kw 2,6 2,8 3,5 3,7 5,13 5,28 6,7 7,25 Air flowrate m³/h 560-490-430-330 660-540-460-330 800-720-610-520 1150-1050-950-850 Dehumidification l/h 0,8 1,4 1,8 2,4 Fan speeds n 4 4 4 4 Sound pressure (sh.-h.-m.-l.) db(a) 39-36-32-26 42-39-33-26 46-42-39-36 48-45-42-39 Sound power U.I. (sh.-h.-m.-l.) db(a) 53-49-45-39 57-53-45-42 58-54-51-48 64-59-56-53 Liquid pipe diameter mm(inch") 6,35(1/4") 6,35(1/4") 6,35(1/4") 6,35(1/4") Gas pipe diameter mm(inch") 9,52(3/8") 9,52(3/8") 12,7(1/2") 15,88 (5/8") Net dimension (H./W./D.) mm 275/790/200 289/845/209 300/970/224 325/1078/246 Net weight kg 9 10 13,5 17 CASSETTE INDOOR UNITS X3I AS35HL X3I AS52HL Capacity kw 3,5 4,0 4,5 5,0 Air flowrate m³/h 600 600 Dehumidification l/h 1,4 1,8 Fan speeds n 3+auto 3+auto Sound pressure (sh.-h.-m.-l.) db(a) 46-44-42 46-44-42 Sound power U.I. (sh.-h.-m.-l.) db(a) 56-54-52 56-54-52 Liquid pipe diameter mm(inch") 6,35(1/4") 6,35(1/4") Gas pipe diameter mm(inch") 9,52(3/8") 12,7 (1/2") Unit net dimension without panel (H./W./D.) mm 230/570/570 230/570/570 Panel net dimension (H./W./D.) mm 50/650/650 50/650/650 Unit net weight without panel kg 18 18 Panel net weight kg 2,5 2,5 DUCTED INDOOR UNITS X3I SD27HL X3I SD35HL X3I SD52HL Cooling Heating Capacity kw 2,50 2,80 3,5 3,85 5,0 5,5 Air flowrate m³/h 450 500 700 Static pressure min-max Pa 0-10 0-10 0-10 Dehumidification l/h 0,8 1,4 1,8 Fan speeds n 3+auto 3+auto 3+auto Sound pressure (sh.-h.-m.-l.) db(a) 37-34-31 39-35-32 41-36-33 Sound power U.I. (sh.-h.-m.-l.) db(a) 47-44-41 49-45-42 50-46-43 Liquid pipe diameter mm(inch") 6,35(1/4") 6,35(1/4") 6,35(1/4") Gas pipe diameter mm(inch") 9,52(3/8") 9,52(3/8") 12,7 (1/2") Net dimension (H./W./D.) mm 200/700/615 200/700/615 200/900/615 Net weight kg 22 23 27 FLOOR/CEILING INDOOR UNITS X3I FC27HL X3I FC35HL X3 FC52HL Cooling Heating Capacity kw 2,5 2,8 3,5 3,85 5,0 5,5 Air flowrate m³/h 650-550-450 650-550-450 950-700-500 Dehumidification l/h 0,8 1,4 1,8 Fan speeds n 7 7 7 Sound pressure (sh.-h.-m.-l.) db(a) 40-38-36 40-38-36 45-42-40 Sound power U.I. (sh.-h.-m.-l.) db(a) 50-48-46 50-48-46 55-52-50 Liquid pipe diameter mm(inch") 6,35(1/4") 6,35(1/4") 6,35(1/4") Gas pipe diameter mm(inch") 9,52(3/8") 9,52(3/8") 12,7 (1/2") Net dimension (H./W./D.) mm 225/1220/700 225/1220/700 225/1220/700 Net weight kg 40 40 40 CONSOLE INDOOR UNITS X3I AF27HL X3I AF35HL X3I AF52HL Cooling Heating Capacity kw 2,5 2,8 3,5 3,85 5,3 5,8 Air flowrate m³/h 500-430-410-370-330-280-250 600-520-480-440-400-360-280 650-620-550-500-450-410-320 Dehumidification l/h 0,8 1,4 1,8 Fan speeds n 7 7 7 Sound pressure (sh.-h.-m.-l.) db(a) 40-38-36-33-30-27-25 42-40-38-37-35-32-27 48-46-44-41-37-35-32 Sound power U.I. (sh.-h.-m.-l.) db(a) 55-53-51-48-45-42-40 57-55-53-52-50-47-42 62-59-57-55-52-50-47 Liquid pipe diameter mm(inch") 6,35(1/4") 6,35(1/4") 6,35(1/4") Gas pipe diameter mm(inch") 9,52(3/8") 9,52(3/8") 12,7 (1/2") Net dimension (H./W./D.) mm 600/700/215 600/700/215 600/700/215 Net weight kg 15 15 15 9

702017003-03/2017 Head office Via Alfeno Varo, 35 25020 Alfianello (BS) ITALY Tel: + 39 0331 755111 Fax: + 39 0331 775501 N.B. The manufacturer assumes no responsability for any errors or inaccuracies regarding the contents of this catalogue, and reserves the right to make any necessary changes to its products, at any time and without prior notice, for technical or commercial reasons. Argo is a brand of, a leading European company in Air Conditioning, Heating and Air Treatment.