TECHNICAL SPECIFICATIONS

Similar documents
TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

TECHNICAL SPECIFICATIONS

FG7T (C and L Series)

RG7D 1-Stage Heat Series

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Comfort, Quality and Efficiency.

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

MERIT SERIES Downflow

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Energy Saving. Space Saving.

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

Multi-Position Gas Furnaces

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Rheem Classic Plus Series Multi position Gas Furnaces

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

MULTI POSITION GAS FURNACE

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

Rheem Classic Series Multi-position Gas Furnaces

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

Ruud Achiever Plus Series Multi-position Gas Furnaces

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

MULTI POSITION GAS FURNACE

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

Ruud Acheiver Series Upflow Gas Furnaces

ELITE SERIES Downflow - High Efficiency Blower Motor

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

Ruud Achiever Series Multi position Gas Furnaces

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

80% A.F.U.E. DOWNFLOW GAS FURNACES

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES. Visit taxcredit for complete details.

Wt. Lbs Model Number (BTUH) Hz

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2. System

8+* Bulletin No November 1997

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

Cooling Capacity CFM in. w.c. (125 Pa)

GMS9/GCS9 SERIES 93% AFUE

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Cooling Capacity CFM in. w.c. (125 Pa)

Multi-Position Gas Furnaces

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

GAS FURNACES 90 PLUS COMMUNICATING MODULATING DOWNFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

G34M Bulletin #69/ August 2003

13 GEP A L P - 1 A

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

TECHNICAL SPECIFICATIONS

HIGH-EFFICIENCY FURNACES

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

Cooling Capacity CFM range

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

Transcription:

TECHNICAL SPECIFICATIONS Model PGF1TA 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 80+ Upflow/Horizontal 2 Stage Gas Furnace with Variable Speed Blower

2

10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY PROMISE The high efficiency 2-Stage gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The extended flush jacket provides a pleasing appliance appearance. Design certified by the Canadian Standards Association (CSA) International. The product is truly designed with the contractor and the consumer in mind. Features and Benefits Best warranty in the business A 20 year warranty on the heat exchanger 10 Year Parts and Labor Warranty and 5 Year Dependability Promise. 100% fired and tested All units and each component (both mechanical and electrical) are tested on the manufacturing line. Best packaging in the industry Unique design assures product will arrive to the homeowner dent free. Clean, quiet and efficient operation Due to the unique design of inshot burners, location of inducer and use of insulation. Operation at low fire uses less fuel than single capacity furnaces. Fixed 30 second blower delay at burner start-up assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 120, 160 and 180 seconds). Fixed 30-second post purge increases life of heat exchanger. SmartStart TM Control Board Provides extended life to ignitors in furnaces using hot surface ignition technology. Programmed to learn the heat-up characteristics of the ignitor, then adapt the ignition time to the characteristics of the furnace so the ignitor is energized appropriately. Dependable, hot surface igniter Innovative application of an appliance type ignitor with a 20-year history of reliability, assures no call-backs because of handling. Color coded wire harness Designed to fit the components, all with quick-connect fittings for ease of service and replacement. Tubular primary heat exchanger Heavy gauge aluminized steel heat exchanger assures a long life. Fixed cooling cycle blower-off delay (TDR) increases cooling performance when matched with a Maytag coil. Approved for category I and III venting systems May be common, dedicated, or horizontal vented for maximum flexibility in installation. Fully insulated blower cabinet for quiet operation. Variable speed blower Maximizes air conditioner and heat pump efficiencies. On selected units, SEER ratings up to 14 and HSPF ratings up to 8.5 are ARI listed. LP convertible Simple burner orifice and regulator spring change for ease of convertibility. Diagnostic light flashes identify limit failure, pressure switch failure and improper ground and polarization for easy troubleshooting. Incorporates integrated control board with connections for electronic air cleaner, humidifier and twinning. Two piece door design enhances furnace appearance and uses screw fasteners for great fit and accessibility. 3 amp fuse protection against low voltage shorts; protects transformer and control board. Low voltage terminal board for easy field wiring. 3

High Efficiency Upflow/Horizontal 80+ Two Stage Gas Furnace Burner Assembly Ignitor Flame Roll-out switch(s) Flame Sensor Pressure Switch Supply Air Limit Switch Gas Valve Vent Assembly Solid state integrated control monitors the burner flame and limit circuit continuously. Low voltage transformer Induced draft blower provides quiet and reliable operation. Blower Door Switch Variable speed motor/blower provides quiet airflow, reliable operation, and is installed on a slide out track. 4

DIMENSIONS Upflow/Horizontal Furnace UPFLOW/HORIZONTAL FURNACE MODELS FURNACE DIMENSIONS AND SHIPPING WEIGHTS Dimensions High Low Flue Shipping Model No Fire Fire A B C D Outlet Weight Input Input Btuh Btuh In. In. In. In. In. Lbs *TA 072C-VB 72,000 50,000 19 3/4 18 1/4 3 3/4 17 1/4 4 152 *TA 096C-VB 96,000 67,000 19 3/4 18 1/4 3 3/4 17 1/4 4 174 *TA 120C-VC 120,000 84,000 22 1/2 21 3 3/4 20 4 182 3/4 3/4 23 3/ 4 19 3/ 4 FLUE OUTLET B C 3/4 3/4 A Unit Shown in Upflow Position Rotate 90 Clockwise or Counter Clockwise for Horizontal Application 25 1/ 8 1 1/ 2 X 3 1/ 2 Cut-out for Gas Connection 1 1/ 2 X 3 1/ 2 Cut-out for Gas Connection 43 7/ 8 Cut-out for Electric Connection 25 1 /4 33 30 1/ 4 7/8 Cut-out for Electric Connection 25 5/ 8 25 1/ 4 Return 15 Air Opening 20 1/ 2 (Side) 7/8 1 1/ 4 23 27 5 /8 1 1/4 D Return Air Opening 1 1/4 23 (Bottom) 5

STANDARD EQUIPMENT Direct vent; draft inducer; pressure switch; redundant main gas control; hot-surface ignition; timed ON/OFF blower controls (TDR); 40VA transformer for air conditioner application; limit controls; direct drive motor; all models can be converted to use L.P. (propane) gas. Factory approved kits only must be used and are available as an optional accessory from your Maytag distributor. SPECIFICATIONS MODEL NUMBER PGF1TA 072( )VB 096( )VB 120( )VC High Fire Rated Input(Btu/h) (a) 72,000 96,000 120,000 High Fire Heating Capacity(Btu/h) 58,000 77,000 96,000 Low Fire Rated Input(Btu/h) (a) 50,000 67,000 84,000 Low Fire Heating Capacity(Btu/h) 40,000 54,000 67,000 AFUE 80+ 80+ 80+ Maximum Heating Ext. St. Press.(in WC) 1.0 1.0 1.0 Blower Wheel D x W 11 x 10 11 x 10 11 x 10 Motor H.P. -Type 3/4 - Variable 3/4 - Variable 3/4 - Variable Motor FLA 9.6 9.6 9.6 High Fire Temperature Rise Range(F) 35-75 40-70 40-70 Low Fire Temperature Rise Range(F) 40-70 45-75 35-65 IDENTIFICATION CODE P G F 1 T A 092 C V B A P = Premier G = Gas F = Full Size Design Series Residential, 2-Stage Heating Input - Btuh (high Fire) 2-Stage Cooling Enabled Cabinet Width B = 19 3/4 C = 22 1/2 Variable Speed C = U.S. / Canada N = Low NOx A = Upflow 80+ AFUE 6

VENTING All models, with the exception of the reduced NOx models, are approved for vertical and horizontal venting applications. All models may be common vented with a gas water heater. Type B gas vent materials may be used when connected to a vertical vent system. The installation must be in accordance with the venting instructions supplied with the furnace. Furnace Model Number Pipe Reducer Maximum Max. Feet PGF1TA Size Needed # Elbows Vent Pipe 072( )VB 3" 4" to 3" 4 35 096( )VB 3" 4" to 3" 4 35 120( )VC 3" 4" to 3" 4 35 ACCESSORIES Kit Order Number U.S. LP Conversion Kit (0 to 10,000 ft.) 904404 Canadian LP Gas Conversion Kit (0 to 4,500 ft.) 904405 Fossil Fuel Kit 914762 Side Return Filter Kit 541036 Bottom Return B Cabinet 903089 Filter (20/Box) C Cabinet 903090 Internal Side Return Filter Wire 903152 Downflow "B" Combustion Floor Base 902677 Downflow "C" Combustion Floor Base 904108 7

CAPACITIES Furnace Airflow Data NOTE: 0 = OFF 1 = ON # Switch not used - Can be 0 or 1. Cooling/Heat Pump Airflow Settings CFM SWITCH NUMBER Nominal A/C and HP Capacity LOW HIGH 1 2 3 4 5 6 7 500 720 0 0 0 1 550 800 0 0 0 0 610 880 0 0 1 0 650 945 1 0 0 1 720 1050 1 0 0 0 800 1155 1 0 1 0 900 1305 0 1 0 1 1000 1450 0 1 0 0 1060 1530 1 1 0 1 1100 1595 0 1 1 0 1170 1700 1 1 0 0 1290 1870 1 1 1 0 Heating Airflow Settings Nominal Airflow Rates (CFM) and Temperature Rises (Degree F) *TA 072-VB Models *TA 096-VB Models *TA 120-VC(B) Models Switches Low Fire Input High Fire Input Low Fire Input High Fire Input Low Fire Input High Fire Input 5 6 7 50,000 72,000 67,000 96,000 84,000 120,000 0 0 # 660 54 1090 50 660 73 1090 63 660 92 1090 84 1 0 # 750 48 1240 44 750 64 1240 58 750 80 1240 74 0 1 # 1220 30 1680 33 1220 40 1680 41 1220 50 1680 55 1 1 # 1300 28 1880 29 1300 37 1880 36 1300 47 1880 49 Notes: 1. Recommended temperature rises are highlighted in bold. 2. Airflow rates of 1800 CFM or more require two return air connections. Data is for operation with filter(s). 3. Temperature rises in the table are approximate. Actual temperature rises may vary. 4. Temperature rises that are shaded grey are for reference only. These conditions are not recommended. 5. For single stage cooling, the indoor blower will operate at the CFM listed in the high column. 5 TON 4 TON 3.5 TON 3 TON 2.5 TON 2 TON Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Maytag is a registered trademark of the Maytag Corporation and is used under license to NORDYNE Inc. 470B-0606 (Replaces 470B-0305) Printed in U.S.A. (06/06)