Installation Instructions Remote Blowers

Similar documents
Downdraft Raised Vent

Integrated Ventilation System

Installation Instructions Preference Wall Mount Range Hood

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

Installation Instructions Induction Cooktop

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

Integrated Hood Liner

Installation Instructions. Discovery Wall Oven. EO, MOH and MOV Series. Part No Rev. M

Integrated Hood Liner

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

Installation Instructions Millennia Cooktops

Installation Instructions Renaissance Integrated Hood Liner


Installation Instructions. Discovery Wall Oven. Preliminary - For Review Only No Scheduled Release Date. For use with models EO, MO and PO

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365

Installation Instructions Outdoor Refrigerator

Installation Instructions. Warming Drawer

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

Installation Instructions Wall Ovens

Installation Instructions. Discovery Wall Oven. Preliminary - For Review Only No Scheduled Release Date. For use with models: EO, MO and PO

Ins t a l l a t i o n In s t r u c t i o n s Wa r m i n g Ov e n For use with models: EW, EWO MW, MWO PW, PWO IWO, IOWO

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

Modernist Warming Drawer

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

Installation Instructions. Warming Drawer. Models: EWD24, EWD27, EWD30, EWD36, IWD24, IWD27, IWD30, MWDV27, MWDH27, MWDV30, MWDH30 PWD27, PWD30

Installation Instructions Built-In Wine Coolers, Beverage Centers

Installation Instructions Dual Fuel Ranges

Installation Instructions Preference. Cooktop. Models: SGM304, SGM365, SGM466. Part No Rev. K

Use, Care, and Installation Guide

ERV3015, ERV3615. Renaissance 30, 36 Wide, High Extension Slim Raised Vents. Top cap with vent down

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Distinctive TM Electric Cooktop

Humidity and Thermostat control box for Attic Fan

Operating and Installation Instructions

Installation Instructions Distinctive. Series Cooktop. Models DCT305, DCT365. Part No Rev. L

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

READ AND SAVE THESE INSTRUCTIONS

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind Professional Series Liners

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER, PRV30, PRV36, PRV48

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

Installation Instructions

Installation Instructions. Warming Drawer

IVI WARNINGS: Must be followed carefully to avoid personal injury. [VL

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Cooktop Chimney Ventilation Hoods

e Bath Fan with Light User s Guide

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

Installation Instructions Renaissance Built-in Dishwasher

Installation Instructions

Table of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

breeze easytm model # F100-1W

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

e Bath Fan with Light User s Guide

INSTALLATION GUIDE Dual Fuel Ranges

Installation Instructions Epicure. Cooktop. Models: ESG366, ESG486. Part No Rev. K

Installation. Professional Built-in Hoods

e Bath Fan with Light User s Guide

CAUTION signals a situation where minor injury or product damage may occur if you do not follow instructions.

Installation Instructions

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS

Installation Instructions. Discovery Gas Cooktop. Models DYCT304G, DYCT365G. Part No Rev. A

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

Use, Care, and Installation Guide

Downdraft Ventilation

Installation Instructions

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Bathroom Exhaust Fan

e Heater/Exhaust Fan/Light User s Guide

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Installation Instructions 30 French Door Built-in Wall Ovens

UNDER CABINET RANGE HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Installation Instructions

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Multi-Function Cooktop

Transcription:

Installation Instructions Remote Blowers Models: REMP3, REMP16 Suitable for use in a household cooking area. Suitable for use with solid state controls. To complete this blower, a Dacor hood assembly or Dacor raised vent must be purchased separately. See the hood or raised vent installation instructions to determine suitability. Part No. 65265 Rev. G

Important Safety Instructions... 1 Important Information About Safety Instructions... 1 Safety Symbols and Labels... 1 General Safety Precautions... 2 Product Specifications... 3 Product Dimensions... 3 Installation Planning and Preparation... 4 Electrical Supply Requirements... 4 Installation Planning... 4 Installation Preparation... 5 Important: Table of Contents Before You Begin... Installation Instructions... 6 Parts List... 6 Installation... 6 Verifying Proper Operation... 7 Technical Data... 8 Installer: In the interest of safety and to minimize problems, read these installation instructions completely and carefully before you begin the installation process. Leave these installation instructions with the customer. Customer: Keep these installation instructions for future reference and the local electrical inspector s use. If You Need Help... Customer Service Information Model Identification If you have questions or problems with installation, contact your Dacor dealer or the Dacor Customer Service Team. For repairs to Dacor appliances under warranty call the Dacor Distinctive Service line. Dacor Customer Service Phone: (800) 793-0093 Monday Friday 6:00 a.m. to 5:00 p.m. Pacific Time Web site: www.dacor.com Dacor Distinctive Service (for repairs under warranty only) Phone: (877) 337-3226 Monday Friday 6:00 a.m. to 4:00 p.m. Pacific Time REMP3 = Remote blower with 8-inch diameter intake REMP16 = Remote blower with 10-inch diameter intake All specifications subject to change without notice. Dacor assumes no liability for changes to specifications. 2008 Dacor, all rights reserved.

Important Information About Safety Instructions Important Safety Instructions The Important Safety Instructions and s in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. Always contact the Dacor Customer Service Team about problems and conditions that you don t understand. See Customer Service Information above. Safety Symbols and Labels DANGER Immediate hazards that WILL result in severe personal injury or death. Hazards or unsafe practices that COULD result in severe personal injury or death. caution Hazards or unsafe practices that COULD result in minor personal injury or property damage. DANGER IMPORTANT: Do not store or use combustible, flammable or explosive vapors and liquids (such as gasoline) inside or in the vicinity of this or any other appliance. Also keep items that could explode, such as aerosol cans, away from the range or cooktop. Do not store flammable or explosive materials in adjacent cabinets or areas. TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. b. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent device, such as a tag, to the service panel. WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. b. c. d. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Ducted fans must always be vented to the outdoors. CAUTION For general ventilating use only. Do not use to exhaust hazardous or explosive materials or vapors. READ AND SAVE THESE INSTRUCTIONS 1

General Safety Precautions Important Safety Instructions To reduce the risk of fire, electric shock, serious injury or death when using this blower, follow basic safety precautions, including the following: Do not install or operate this unit if it has been damaged, dropped, has damaged electrical wiring or is not working properly. If the product is damaged when received, immediately contact the dealer or builder. Install or locate this appliance only in accordance with these installation instructions and the Dacor hood or downdraft vent installation instructions. Improper installation, adjustment, alteration, service or maintenance can cause serious personal injury or property damage. Before installing or servicing the in-line blower, make sure that power to the wiring is turned off at the circuit breaker or fuse box. Make sure that the service panel is locked or tagged to prevent power from being switched on accidently. To reduce the risk of electric shock or fire, the total combined current draw of the in-line blower and the hood or downdraft vent must not exceed the maximum rated input current of the hood or downdraft vent. A minimum of two people are required to safely install this appliance. Never allow the filters or vent openings on the hood or downdraft vent to become blocked or clogged. Do not allow foreign objects, such as cigarettes or napkins, to be sucked into the vent holes. Tape all duct joints securely to prevent combustion by-products, smoke or odors from entering the home. Doing so will also improve system efficiency. Do not route electrical wiring near hot surfaces. Do not ground the appliance with the neutral (white) house supply wire. A separate ground wire must be utilized. To prevent a damaged or non-functional system, complete electrical connections properly. Follow the wiring diagrams carefully in the hood or in-line blower installation instructions to ensure a proper installation. After installation or service, make sure that all blower wires are tightly connected to their respective terminals. The installer must show the customer the location of the fuse or circuit breaker panel so that the customer knows where and how to turn the power off. 2

Product Dimensions Product Specifications All tolerances: +1/16, -0, (1.6 mm,0) unless otherwise noted. 19" (483mm) 17 3/8" (441mm) 9 1/2" (241mm) 7 1/2" (191mm) 7 15/16" (202mm) 5 13/16" (148mm) Power Supply Conduit Hole C L C L 3 5/8" (92mm) 9 1/4" (235mm) 24 1/4" (616mm) C L 8" Nom. (203mm) 25 1/2" (648mm) Intake Collar Mounting Flange Intake Collar REMP3 26" (660mm) 24 1/4" (616mm) 13 1/8" (333mm) 9 1/2" (241mm) 11 1/2" (292mm) 9 9/16" (243mm) Power Supply Conduit Location C L C L 3 5/8" (92mm) 12 1/4" (311mm) 10" Nom. (254mm) 32 1/4" (819mm) C L Intake Collar 33 1/2" (851mm) Intake Collar Mounting Flange REMP16 3

Installation Planning and Preparation Electrical Supply Requirements The power for this blower is supplied via 1/2 3-wire wiring/conduit (not included) by an approved Dacor hood or raised vent. The wiring/conduit is installed between the hood or raised vent and the blower and shall be terminated on each end by a 1/2 UL certified strain relief. The power is turned on and off by the power switch on the approved ventilation device. The correct voltage, frequency and amperage must be supplied to the hood or raised vent and the blower from a grounded, single phase circuit that is protected by a properly sized circuit breaker or time-delay fuse. The circuit must have the capacity to supply the combined power requirements for the hood or raised vent and the in-line blower. See the installation instructions for the hood or raised vent to determine total power requirements in combination with the blower electrical specifications. Model Number* REMP3 REMP16 Power Requirements** 120 Vac, 60 Hz, 3.8 Amp 120 Vac, 60 Hz, 2.7 Amp * All models are thermally protected. ** In addition to the hood or raised vent Blower Rating*** 600 CFM 1000 CFM Nominal rating at 0 inches static pressure. See *** Technical Data section for actual ratings. The above specifications are for reference only, See the data label on the blower for exact specifications. If the above specifications vary from the label on the blower, use the data on the blower label. It is the owner s responsibility to ensure that the power supply is installed by a licensed electrician. The electrical installation must comply with the latest revision of the National Electric Code ANSI/NFPA 70 (latest revision) and local codes and ordinances. A copy of the specification may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101 If the electrical service provided does not meet all product specifications, or does not conform to the NEC or local standards, do not proceed with the installation. Call a licensed electrician to correct the electrical service before proceeding. Installation Planning System Layout To avoid the risk of fire due to the unit overheating: DO NOT install this blower with a hood or raised vent that has an internal blower. DO NOT install more than one blower to increase the length of the duct run. Even small differences between blower air flow rates can greatly reduce the air draw by the hood or raised vent. Consult the installation instructions for the raised vent or hood for complete layout and duct system planning instructions. Observe all location and duct system design instructions. The remote blower needs to be wired to turn on when the raised vent or hood is turned on by routing wiring/ conduit parallel to the duct work. Connect the wiring/ conduit to the raised vent or hood on one end and the remote blower on the other. There is a 7/8 electrical access hole on the bottom of the blower. Blower Location and Mounting Install the blower in a location that allows it to be accessed for service if necessary. There must be enough room to remove the top cover of the unit and enough room to access the power terminals and mounting holes located inside. The mounting location needs to allow for a cutout under the unit for the duct and wiring/conduit to pass through the wall or roof into the blower assembly. See Figure 1. The mounting location must allow for a clearance of at least 15 (381mm) between the blower air discharge and any obstructions (vents, pipes, etc.) See below. Blower Roof Duct and wiring passing through cutout, no obstructions within 15 inches Wall Blower Example of Roof Installation Example of Wall Installation 4

Installation Planning and Preparation Blower Location and Mounting (cont.) Select a location that can properly support or can be reinforced to support the weight of the blower (see weight table below). The unit requires a mounting surface around the perimeter of the base of the unit 2 in width and thick enough to accommodate the 8, 2 1/2 long mounting screws that are provided with the unit. All contact surfaces between the blower and any mounting surfaces must be solid and at right angles. See Figure 1 for the required mounting surface dimensions. B Model Number REMP3 REMP16 Approximate Shipping Weight Weight Table A E 35 lbs. 55 lbs. C F D The blower must also be mounted vertically or at a pitch of 2:12 or greater. If the pitch of the mounting surface is less than 2:12, construct a roof curb to mount the blower. See Installation Preparation for exact dimensions. When mounted in a exposed location shield it to prevent the accumulation of water in the chassis. On horizontal installations, point the discharge in the same direction as prevailing winds. When mounted vertically, the discharge must point down. Blower Installation Preparation 1. 2. 3. Prevailing Wind Roof Curb Figure 2: Installation with Roof Curb (for flat roofs) Prepare the mounting surface and reinforce it if necessary according to the Blower Location and Mounting specifications starting on page 4. Make a cutout in the center of the mounting location according to Figure 1. On roofs with a pitch of 2:12 or less, construct a roof curb according to the specifications below. Attach it to the mounting surface and seal it around the base. Duct and Conduit Cutout Reinforced Mounting Surface Figure 3 25 1/2" (648mm) 2" (51mm) 2" (51mm) around entire perimeter 6" (152mm) Side Figure 1: Required Mounting Surface Dimensions 2" (51mm) REMP3 Roof Curb 19" (483mm) 23 1/4" (591mm) Dimension REMP3 REMP16 A 19 (483mm) 26 (660mm) B 25 1/2 (648mm) 33 1/2 (851mm) C 4 (102mm) 4 (102mm) D 2 1/8 (92mm) 2 1/8 (92mm) E 11 (279mm) 13 (330mm) F 12 5/8 (321mm) 16 5/8 (422mm) The base of the remote blower needs to be sealed with mastic or the equivalent to prevent leaks. 2" (51mm) REMP16 Roof Curb 33 1/2" (851mm) 26" (660mm) 2" (51mm) 30 1/2" (776mm) 6" (152mm) 5

If the electrical service provided does not meet the power requirements for the hood/raised vent and the blower combined, do not continue with the installation. Contact a licensed electrician to correct the situation before continuing. Failure to connect the wiring as specified may result in an electric shock hazard and/or improper blower operation. To avoid the risk of fire or electric shock, turn off power at the circuit breaker panel or fuse box before connecting the blower to the power source. The blower assembly is heavy. Do not attempt to lift or move it without assistance. Parts List Verify Package Contents 2 1/2 wood mounting screws (8) Blower assembly Parts Required 3 conductor wiring/conduit with UL certified strain relief on each end (length is determined by remote blower location). If the blower will be mounted to a surface other than wood, fasteners designed for the material the unit will be mounted to must be provided. The fasteners must be capable of supporting the weight of the blower (see weight table on page 5) and meet local codes and ordinances. Consult the hood or raised vent installation instructions for additional part requirements. Installation 1. Before installing the blower, unpack the unit and check for physical damage to the motor and blower assembly. To do so, reach in through the intake collar and spin the fan blades slowly. They should spin freely and quietly without vibration. Installation Instructions Intake Collar Fan Blades 2. 3. 4. 5. 6. Remove the blower s top cover by removing the screws around the edge that hold it in place. Apply sealant between the blower and the mounting surface where the flange around the edge of the blower will rest. Air Roof Sealant Figure 7 Blower Flange Figure 6 Sealant 45 Adjustable Elbow Round Duct Pick up the blower assembly and center it on the mounting surface inserting the intake collar into the cutout. While holding the blower in place, fasten it to the mounting surface with eight (8) mounting screws. The mounting holes are located inside the blower assembly chassis near the sides. Install the duct work according to the installation instructions for the hood or raised vent. Support the duct weight as necessary to ensure properly sealed joints. Figure 5 Bottom of Blower 6

Electrical Installation 7. 8. 9. Run the wiring used to supply power from the installed raised vent or hood to the blower parallel to the duct work. Make sure that power to the raised vent or hood is disconnected or turned off at the circuit breaker or fuse box. With the UL certified strain relief attached to the end of the wiring/conduit, feed the wires into the electrical access hole on the under side of the blower and attach it. Cutout Blower 10. From inside the blower assembly, strip the three wires. 11. Connect the black (L1) wire to the L2 blower power terminal (see Figure 9). Tighten the terminal screw firmly into place. IMPORTANT: The L2 (hot) terminal on the blower has the BLUE wire from the blower wiring harness connected to it. Installation Instructions Roof Figure 8: Wiring/Conduit Connection Wiring/conduit connected to blower 12. Connect the white (neutral) wire to the N2 blower power terminal (see Figure 9). Tighten the terminal screw firmly into place. IMPORTANT: The neutral (N2) terminal on the blower has the BLACK wire from the blower wiring harness connected to it. 13. Connect the green (GND) wire to the GND blower power terminal (see Figure 9). Tighten the terminal screw firmly into place. 14. Check the wires from the blower wiring harness to make sure that they are firmly attached to the terminal according to Figure 9. Reconnect any wires that are loose. Make sure all terminal screws are tight. 15. Replace the blower s top cover and screws. 16. Secure the other end of the wiring/conduit to the hood or raised vent and connect the wires according to the hood or raised vent installation instructions. Verifying Proper Operation Read the raised vent or hood use and care manual completely before operation. Test the blower operation according to the Verify Proper Operation section of the hood or raised vent installation instructions. If the blower does not work after having been properly installed, contact Dacor Distinctive Service at (877) 337-3226. Do not attempt to repair the unit yourself. Dacor is not responsible for the costs required to correct problems caused by a faulty installation. Black White Green Wires from hood/raised vent L2 N2 GND Blue Black Not Used Green Figure 9: Wiring Diagram To blower wiring harness 7

REMP Series Blower Ratings Technical Data Model Number Nominal Rating* Actual Rating* REMP3 600 CFM 620.5 CFM REMP16 1000 CFM 994.8 CFM * At 0 static pressure Static pressure - inches of water 5.0 4.0 3.0 2.0 1.0 0 REMP3 Blower Performance 100 200 300 400 500 600 700 Airflow CFM (Cubic feet/minute) Static pressure - inches of water REMP16 Blower Performance 2.5 2.0 1.5 1.0 0.5 0 200 400 600 800 1000 Airflow CFM (Cubic feet/minute) 8

Dacor 1440 Bridge Gate Drive, Diamond Bar, CA 91765 Tel: (800) 793-0093 FAX: (626) 403-3130 www.dacor.com