Moisture Separator.

Similar documents
AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

The Role of Air Handling Units in Combating the Spread of Infectious Disease

DIVISION 15 MECHANICAL

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

1.1 This section applies to air handling units for HVAC Systems.

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

SECTION ELECTRIC WATER HEATERS

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

University of Delaware

FAN SEPARATOR. Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream.

High Profile Evaporator

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

VSA/VSB & KSA/KSB Series Air Doors

INSTALLATION, OPERATION AND MAINTENANCE MANUAL IFB HEATING COILS

SECTION AIR HANDLING UNIT

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

Reliability is a beautiful thing TM CUBELET ICE DISPENSER DCM-500BAF DCM-500BWF DCM-750BAF DCM-750BWF INSTRUCTION MANUAL

TYPICAL CPA SPECIFICATIONS

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Model No. Serial No. Original Purchaser. Address. City and State Zip. Dealer. Address. City and State Zip. Installation Date Name Signature

SECTION CUSTOM INDOOR CENTRAL-STATION AIR-HANDLING UNITS For large systems, 50,000 cfm or more.

A. This Section includes air-handling units with coils for indoor installations.

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

SECTION AIR COILS

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Custom Duct Heaters. Special Applications

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

Direct Fired Heater Model AD Specification

Custom Duct Heaters. Special Applications

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Kitchen Exhaust Air Cleaning Systems

Modular Supply Make-Up Air Unit

SECTION DOMESTIC WATER HEATERS

Commercial Packaged Rooftop Systems

VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Coil Unit with Enhanced Humidity Control

Vertical Stack Fan Coil Units Models: TVA, TVE, TVS

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

ENGINEERING & SERVICE

CAT-SIUH-2000(3) SUPERSEDES CAT-SIUH-98(2) SARAVEL INDUSTRIAL UNIT HEATERS

Contents INDEX. TDM Series Indirect Fired Heaters

ACT Cartridge Dust Collector

5.0 Installation Instructions

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

SUNCOURT RADON FAN MODEL: RDN04 & RDN04-3, RDK04 & RDK04-3 INSTALLATION INSTRUCTIONS

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

PRODUCT CATALOG BLOWER COILS.

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

Operation & Maintenance Manual

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Installation, Operation, and Maintenance Information

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

TEMSPEC INC. VERTICAL FAN COIL UNIT MODELS TVA, TVE, TVS

INSTALLATION, OPERATION & MAINTENANCE MANUAL WING FRESH AIR SUPPLY UNIT Steam & Hot Water

Double Skin Casing Air Handling Units

READ AND SAVE THESE INSTRUCTIONS. Air Boss Model T5200 Custom Packaged Electronic Air Cleaner. TRION

Please Read and Save These Instructions.

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Advance Release September 2009

INDOOR, SUSPENDED, STEAM OR HOT WATER HYDRONIC UNIT HEATER FOR VERTICAL OR HORIZONTAL CONFIGURATION

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

TABLE OF CONTENTS HOW AIRBORNE CONTAMINATION IS REMOVED 3 DIMENSIONS 4 SPECIFICATIONS 6 PLANNING THE INSTALLATION 7 ASSEMBLY & INSTALLATION 10

May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

15900 HVAC INSTRUMENTATION AND CONTROLS

T1001 Module T2002 Module T1300 T2600. Air Boss T-Series Custom Packaged Electronic Air Cleaner READ AND SAVE THESE INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

SECTION (15820) - AIR DUCT ACCESSORIES

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

EHH SERIES DRAW THROUGH FAN COILS CFM

SECTION DUCTWORK

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

INSTY-PAC EXTERNAL MOUNT MULTIPLE TUBE ASSEMBLY

Shipboard Electric Water Heater

installation, operation & Maintenance manual Floor-mounted Induction units

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

Transcription:

PRODUCT DATA SERIES 12MS PD-AL12MS-03A JANUARY 2003 HVAC ACCESSORY EQUIPMENT SERIES 12MS 12" MOISTURE SEPARATOR SECTION Moisture Separator The Series 12MS is a Moisture Separator Section designed for those applications where removal of excessive water, oil mist, fog or water-like elements from a saturated air stream is necessary. It is particularly useful in systems where saturated air is allowed to condense out, such as downstream of DX, chilled water coils, steam or mist humidifiers. How It Works... CONSTRUCTION FEATURES 16 GAUGE ALUMINIZED STEEL CONSTRUCTION FACTORY ASSEMBLED 2 LIFT-OFF ACCESS DOORS VERTICAL DRAIN SYSTEM 4" TRACK SYSTEM FOR THE CELLS DRAIN HOLES IN TRACK The housing utilizes 4" deep FILTER-LINE TM Moisture Separator Cells which capture and then separate moisture from the air stream. Applying a compact series of flat, dense, aluminum screening materials, each cell creates over 64 square feet of surface area in the 2" media pack. This enormous amount of surface area forces moisture to condense, bead and accumulate on one of the more than 2,200,000 individual filament intersects. Once collected, the accumulated moisture begins to weep or drip downward where the fluent is pooled and released through a series of drain holes that channel the moisture onto an aluminum extruded slide track. Once collected in the track, the run-off is funneled into a central vertical drain system that brings it directly to a collection pan at the base of the unit. This crossbroke drain pan has at its center and bottom a factory installed pipe coupling, easily accessible for field piping and installation, which completes the collection process in an effective and efficient manner. Rugged Construction The ACCESS-LINE Series 12MS is manufactured from 16 gauge aluminized steel and equipped with two fully gasketed, lift-off access doors to prevent air or moisture bypass. Complete with extruded aluminum tracks, drain holes, a vertical drain system and a drain pan, this section can also be fabricated from 304 stainless steel. Corporate Headquarters P.O. Box 14187, Louisville, Kentucky 40214 Phone: (502) 366-6002 Fax: (502) 366-6255 E-Mail: askus@blcind.com www.blcind.com BLC-WEST Phone: (480) 839-5333 Fax: (480) 839-1584 We reserve the right to make changes in product design and product specifications without prior notice or obligation. Breathe Easy, We Have The Line On Air Filtration.

Moisture Separator Section: Options Double Wall Insulation isolates the 12MS Section, combating vibration, noise and condensation. Weatherproof units for outside installations, Flange Adapters for all commercial and custom air handling units, Epoxy Coating and High Pressure (14 gauge aluminized) constructions are also available as needed. It is important to note that BLC highly recommends using 304 Stainless Steel construction for both Moisture Separator Sections and Cells. Stainless Steel construction ensures unit and system integrity in the most corrosive environments. EQUIPMENT OPTIONS... DOUBLE WALL INSULATION WEATHERPROOFING HIGH PRESSURE FLANGE ADAPTERS SUPPORT LEGS HANGER BRACKETS STATIC TAPS STAINLESS STEEL These and other specialty options are available, please contact factory for further information. More than 2,200,000 individual filament intersects force moisture to accumulate in the Moisture Separator Cell Dimensional Data HEIGHT ACTUAL CODE HEIGHT (Nominal) 07 85 3/4" 06 74 1/16" 05 62 1/16" 04 50 3/8" 03 38 3/8" 02 26 11/16" 01 14 11/16" MODEL EXT. WIDTH CODE (Nominal) 01 02 03 04 05 06 07 08 09 10 ACTUAL WIDTH 11 1/2" 3/8" 23 1/2" 3/8" 3435" 7/8" 4647" 7/8" 58 3/8" 1/2" 70 3/8" 1/2" 8182" 7/8" 9394" 7/8 7/8" 105 3/8" 1/2" 117 3/8" 1/2" 02X07 03X07 04X07 05X07 06X07 07X07 08X07 09X07 10X07 7000 10000 14000 17000 21000 24000 28000 31000 35000 1H 3F 4H 3F 2H 6F 5H 6F 3H 9F 6H 9F 4H 12F 7H 12F 5H 15F 01X06 02X06 03X06 04X06 05X06 06X06 07X06 08X06 09X06 10X06 3000 6000 9000 12000 15000 18000 21000 24000 27000 30000 3H 3F 3H 3F 6F 3H 6F 9F 3H 9F 12F 3H 12F 15F 01X04 2000 2H 01X02 1000 1H 02X05 5000 1H 2F 02X04 4000 2F 02X03 3000 1H 1F 02X02 2000 1F 02X01 1000 1H 03X05 7000 3H 2F 03X04 6000 2H 2F 03X03 4000 2H 1F 03X02 3000 1H 1F 04X05 10000 2H 4F 04X04 8000 4F 04X03 6000 2H 2F 04X02 4000 2F 04X01 2000 2H 05X05 12000 4H 4F 05X04 10000 2H 4F 05X03 7000 3H 2F 05X02 5000 1H 2F 06X05 15000 3H 6F 06X04 12000 6F 06X03 9000 3H 3F 06X02 6000 3F 06X01 3000 3H 07X05 17000 5H 6F 07X04 14000 2H 6F 07X03 10000 4H 3F 07X02 7000 1H 3F 08X05 20000 4H 8F 08X04 16000 8F 08X03 12000 4H 4F 08X02 8000 4F 08X01 4000 4H 09X05 22000 6H 8F 09X04 18000 2H 8F 09X03 13000 5H 4F 09X02 9000 1H 4F 10X05 25000 5H 10F 10X04 20000 10F 10X03 15000 5H 5F 10X02 10000 5F 10X01 5000 5H 1. 2. 3. 4. H denotes half size filter - 11 3/8 x 23 3/8. F denotes full size filter - 23 3/8 x 23 3/8. denotes unit requires an 11 3/8 x 11 3/8 blank-off panel, which is supplied. Unit depth is 12". MODEL NUMBER KEY 12MS10x04 Insert model number extension to complete model number. 12- MS- 10-04- 12" Depth Moisture Separator Unit Width Unit Height

Views of the Moisture Separator Section Options Front view with 2 Cells only (") Side view showing Cells in tracks (#) Back view with all 4 Cells (") Extruded Tracks and Vertical Drain (#)

The Moisture Separator Cells Used in conjunction with the Moisture Separator Section, the BLC FILTER-LINE Moisture Separator Cell (MSC) loads quickly and efficiently into it. Particularly convenient when accessing for cleaning, these sturdy 4" cells can either be immersed and wet soaked or pressure washed, provided they are not subjected to extraordinarily high pressure flow rates. Fabricated from 16 gauge aluminized steel, the Moisture Separator Cells are available in full (24 x 24) and half (12 x 24) nominal sizes. The 4" Moisture Separator Cell is equipped with a primary 2" moisture arrestor and a secondary 2" channel collector for the accumulating fluent. Once pooled, the water or fluid is transferred to the equipment section via a series of drain holes that channel the moisture. PERFORMANCE DATA When operated at 500, the MSC is over 99% efficient on droplet sizes of 20 microns or greater. The cell is 91% efficient on droplet sizes of 10 microns or larger, and 58% effective on moistures sized at 4 microns or bigger. Consult FILTER-LINE Series MSC for additional information and performance data on these cells. MODEL NUMBER KEY FLMSCG42424 Insert model number extension to complete model number. Notes: FL- MSC- G- 4-24- 24- FILTER-LINE TM Moisture Separator Cell Side Sealing Gasket Cell Depth Cell Width Cell Height Moisture Separator Cells for use in 12" Moisture Separators are supplied with side sealing gasket. See FILTER-LINE TM Series for more Product Data information about Moisture Separator Cells. PERFORMANCE DATA INITIAL RESISTANCE SERIES @300 @350 @400 @450 @500 @550 @600 MSC.08.12.17.21.25.29.34 1.5 13% FILTER-LINE SERIES TM SERIES MSC MSC MOISTURE SEPARATOR CELLS FOR USE FOR IN 12" SIDE-ACCESS MOISTURE SEPARATOR HOUSINGS MODEL NUMBER NOMINAL SIZE ACTUAL SIZE FLMSCG41224 12 x 24 x 4 11 3/8 x 23 3/8 x 3 7/8 FLMSCG41620 16 x 20 x 4 15 1/2 x 19 1/2 x 3 7/8 FLMSCG41625 16 x 25 x 4 15 1/2 x 24 1/2 x 3 7/8 FLMSCG42020 20 x 20 x 4 19 1/2 x 19 1/2 x 3 7/8 FLMSCG42025 20 x 25 x 4 19 1/2 x 24 1/2 x 3 7/8 FLMSCG42412 24 x 12 x 4 23 3/8 x 11 3/8 x 3 7/8 FLMSCG42424 24 x 24 x 4 23 3/8 x 23 3/8 x 3 7/8 EFFICIENCY VERSUS DROPLET SIZE MICRON SIZE OF DROPLETS 2.0 25% 1. 2. 4.0 58% 6.0 76% EFFICIENCY RATING 8.0 10.0 12.0 86% 91% 96% 14.0 97% 16.0 98% 18.0 99% 20.0 100% One Year All Parts Warranty BLC Industries, Inc. guarantees the ACCESS-LINE 12" Moisture Separator Section to be free from defects in materials of construction or workmanship for a period of one (1) year from the date of shipment, when installed in accordance with equipment instructions and when Moisture Separator Cells are supplied by none other than BLC Industries, Inc. Within that time, any defective part will be replaced on a NO CHARGE basis. Provided the defective part is returned to the factory (freight prepaid by the customer). Replacement parts are F.O.B. Louisville, Kentucky. All returned parts must be accompanied by a Return of Goods Authorization. Please notify BLC Industries, Inc. of intent to return goods.

SPECIFICATION DATA SERIES 12MS SPD-AL12MS-03A JANUARY 2003 HVAC ACCESSORY EQUIPMENT MOISTURE SEPAR ARATOR 12" MOISTURE SEPARATOR SECTION SPECIFICATIONS: Vertical Drain System 4" Track System Completely Factory Assembled 16 Gauge Aluminized Steel Lift-Off Access Doors Drain Holes in Slide Track Depth: 12" SIDE VIEW ---------- THROUGH THE DOOR Track for the Cell 2" Collection Area CLEAN AIR Vertical Drain System Drain Pan Drain 1/2" IPS Coupling 4" Moisture Separator Cell Dimple AIR FLOW 2" Moisture Arrestor TOWARD THE DRAIN Drain Holes OPTIONS: Double Wall Insulation Weatherproofing High Pressure Flange Adapters Support Legs Hanger Brackets Static Taps Stainless Steel Condensed Moisture going down the Cell Corporate Headquarters P.O. Box 14187, Louisville, Kentucky 40214 Phone: (502) 366-6002 Fax: (502) 366-6255 E-Mail: askus@blcind.com BLC-WEST Phone: (480) 839-5333 Fax: (480) 839-1584 www.blcind.com We reserve the right to make changes in product design and product specifications without prior notice or obligation. Breathe Easy, We Have The Line On Air Filtration.

MECHANICAL SPECIFICATIONS - MOISTURE SEPARATOR SECTIONS STANDARD UNIT CONSTRUCTION Material of Construction Moisture Separator Section(s) shall be manufactured of 16 gauge aluminized steel. All fasteners shall be corrosion resistant finish. Track System Moisture Separator Section s filter track shall be manufactured from aluminum extrusion and allow for 4 inch nominal Moisture Separator Cell installation. Each track shall seal the cell(s) at top and bottom by use of fin-seal gasket. The track shall be sealed at its ends by use of EPDM gasket. Vertical Drain System Moisture Separator Section(s) are provided with drain connections of 1/2 inch IPS coupling(s) in the bottom drain pan of the section. Internal drain tubes are provided in sections more than one cell high and are completely factory assembled. Drain quantities: unit widths of 01-04, one (1) drain; unit widths of 05-08, two (2) drains; unit widths of 09 and 10, three (3) drains. Operating Static Pressure Moisture Separator Section(s) shall be capable of operating at static pressures of up to 3" W.G. (positive/negative). Access Door(s) Moisture Separator Section(s) shall be provided with pan-type, crossbroke door panel(s) with over-center, positive lock latches. Door(s) shall be sealed at perimeter with EPDM gasket. Door(s) shall be provided with replaceable liftoff hinges. One (1) door or two (2) doors construction per customer specification. Assembly Moisture Separator Section(s) shall be completely factory assembled with 1 1/2 inch mounting flanges provided for field installation. UNIT OPTIONS Double Wall Insulation Moisture Separator Section(s) shall be provided with 1 inch thick double wall insulation in 24 gauge aluminized steel panels. Panel location: interior of door panels, exterior of top/bottom panels and end panel of 1 door units. Insulation may be 1.5 or 3.0 pound density. Weatherproofing Moisture Separator Section(s) shall be provided with 16 gauge aluminized steel pitched rain roof. All seams shall be sealed using a high viscosity, permanent sealer (non-silicon). High Pressure Moisture Separator Section(s) shall be provided to meet operating static pressure of 10" W.G. (positive/negative). Door(s) are provided with full length piano hinges welded in place. Consult factory for other high pressure applications. Mounting Flange Adapters Moisture Separator Section(s) shall be provided with 16 gauge aluminized steel flat adapter flange to match customer equipment/specifications. Flanges may be single-air entering, single-air leaving or double-air entering and air leaving per customer requirements. Support Legs Moisture Separator Section(s) shall be provided with 12 gauge aluminized steel support legs. Maximum height of 5 inches from bottom of flange to floorline. Quantity of support legs: 01-04 wide, 2 support legs; 05-07 wide, 3 support legs; 08-10 wide, 4 support legs. For other applications, consult factory. Hanger Brackets Moisture Separator Section(s) shall be provided with 12 gauge aluminized steel hanger brackets welded to the top panel. Location may be: one (1) pair of brackets-air entering/top corners or one (1) pair of brackets-air leaving/top corners. A 5/8 inch diameter hole is provided for hanger rod. Hanger brackets are for support of the cell section only. Any other equipment or duct connections must be supported independently. Static Taps Moisture Separator Section(s) shall be provided with static pressure fittings for 1/4 inch metal tube connection. Tap location no. 1: before Moisture Separator Cell. Tap location no. 2 : after Moisture Separator Cell. Alternate Material of Construction Moisture Separator Section(s) shall be manufactured of stainless steel (type 304 or 316). Air dried epoxy coated section(s) may be provided, either coated: interior-only, exterior-only, or both interior and exterior.

SUBMITTAL DATA ACCESS-LINE 12MS MOISTURE SEPAR ARATOR SD-AL12MS-03A JANUARY 2003 BLC Order Number Customer Project Name Tag Purchase Order Ship Date BLC Model Number Qty. Width Notes Door Location 2 Doors - All 12MS Units are supplied with (2) Access Doors Standard. Height Moisture Cell Information: 4" Panel Type - All 12MS Units are designed for 4" Cells. Unit Depth Weatherproofing Double Wall Insulation 1.5# 3.0# Stainless Steel Alloy High Pressure POS NEG W.G. Support Legs Hanger Brackets Adapters 12" - 4" Moisture Cells (12" Actual Depth) Custom Air Entering Air Leaving Both Air Filter Monitoring Information Static Taps Air Filter Gage Locations - (See Note 4) 1 3 Model Field Mount AIR FILTER INFORMATION (For each unit shown at left.) By BLC Initial Supply Factory Mount By Others Spare Set *BLC provides no warranty as to the fit or performance of air filters supplied by others. MODEL 01 02 03 04 05 06 07 08 09 10 Number Required - 12 x24 WIDTH 11 1/2 23 1/2 35 47 58 1/2 70 1/2 82 94 105 1/2 117 1/2 Number Required - 24 x24 MODEL 07 06 05 HEIGHT 85 3/4 74 1/16 62 1/16 Plan Air Flow Unit Width Access Door Both Ends 3"-0" Recommended For Service Unit Depth Unit Air Filter Type 12x24 Model Number 24x24 Model Number ASHRAE Efficiency Moisture Separtor Cell FLMSCG41224 FLMSCG42424 100% @ 20 MICRON DROPLET 04 03 02 50 3/8 38 3/8 26 11/16 1 1/2" Perimeter Flange, Undrilled Unit Height Air Flow Initial Pressure Drop Recommended Final.25 @ 500 N/A BLC highly recommends the following: 01 NOTES: 14 11/16 1. MATERIAL OF CONSTRUCTION: 16 GAUGE ALUMINIZED STEEL. 2. UNITS ACCOMMODATE 11 3/8 X 23 3/8 OR 23 3/8 X 23 3/8 INCH FILTERS. 3. FILTER TRACKS ARE EXTRUDED ALUMINUM AND ARE 3 7/8" DEEP FOR 12MS HOUSINGS. 4. OPTIONAL STATIC TAP LOCATION: 1- BEFORE PREFILTER 3- AFTER FINAL FILTER. 5. UNIT EQUIPPED WITH AN INTERNAL VERTICAL DRAIN SYSTEM. 6. 1/2" IPS COUPLING FOR DRAIN CONNECTION. BLC INDUSTRIES, INC. Front Elevation LOUISVILLE, KENTUCKY PHONE: (502) 366-6002 FAX: (502) 366-6255 6" 1/2" IPS Drain Coupling End Elevation www.blcind.com Approved/Date 304 stainless steel construction for Moisture Applications. Factory mounted gage for monitoring these troublesome applications. Breathe Easy, We Have The Line On Air Filtration.

TECHNICAL DATA SERIES MS TD-ALMSI0I-A JANUARY 2001 HVAC ACCESSORY EQUIPMENT SERIES MS INSTALLATION AND OPERATION INSTRUCTIONS INSTALLATION AND OPERATION INSTRUCTIONS MOISTURE SEPARATOR SECTION ORDER NUMBER: SERIAL NUMBER: Corporate Headquarters P.O. Box 14187 Louisville, Kentucky 40214 Phone: (502) 366-6002 Fax: (502) 366-6255 BLC-West 4816 S. Ash Avenue, Suite 105 Tempe, Arizona 85283 Phone: (480) 839-5333 Fax: (480) 839-1584 We reserve the right to make changes in product design and product specifications without prior notice or obligation. Breathe Easy, We Have The Line On Air Filtration. TD-ALMSIOI-A.PM6

INSTALLATION INSTRUCTIONS MOISTURE SEPARATOR SECTION I. II. III. IV. V. READ ENTIRE INSTALLATION INSTRUCTIONS BEFORE INSTALLING UNIT. PRELIMINARY INSTALLATION OPERATIONS A. B. C. D. E. Separate all cartons marked Filters from material received. Store Filters in clean, dry place until system is ready to be operated. DO NOT OPEN CARTONS AT THIS TIME. Distribute filter units as required to system locations. (See markings on each housing.) Carefully uncrate filter housings. Systems must allow for proper access to filters for routine servicing. General rule is to use housing depth. System must provide for firm, level and plumb installation for filter housing. DO NOT DISTORT FILTER HOUSING. INSTALLATION OF FILTER HOUSING A. B. C. Installation of housing can be attained by anchoring duct work to and from housing flange. Housing flange(s) should be caulked to deter air by-pass. Housing is supplied with an air flow label to ensure proper orientation. Connection to 1/2 IPS drain(s) from bottom pan to be made at this time. FILTER INSTALLATION A. B. C. D. Open access door. Slide appropriate filter into housing tracks. Quantities and Model Numbers of filters are listed on unit ID nameplate. Secure access door. The use of a manometer is recommended to check pressure drop of final filter for determining when renewal of filter should be made. CAREFULLY REVIEW ABOVE INSTRUCTIONS. CLEANING/MAINTENANCE OF MOISTURE SEPARATOR CELLS A. B. C. D. E. Remove Filter(s) from unit. Wash with hot soapy water, rinse and flush with clean water. Can be steam cleaned. Remove excess water by blowing out with air hose if necessary. Replace filter(s) in unit.