DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

Similar documents
SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

HEAT RECOVERY AIR HANDLING UNIT

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

HEAT RECOVERY VENTILATOR

Air handling unit. BlauAir RH USER S MANUAL

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

USER S MANUAL. VKP Series INLINE FAN

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

HEAT RECOVERY AIR HANDLING UNITS

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

AXIAL FANS USER S MANUAL

Turbo. Service Instructions

Wind. Service instruction

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

USER S MANUAL DN-2. Drain pump

AIR HANDLING UNIT WITH HEAT RECOVERY

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

CENTRIFUGAL CEILING EXTRACT FAN

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

CENTRIFUGAL CEILING EXTRACT FAN

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

NKW. Heater series HEATERS

Centrifugal inline fans

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

Aero. Service Instructions

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

Calm. Service Instructions

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

USER'S MANUAL PS

PGDX Rectangular duct coolers with DX coil

USER S OPERATION MANUAL HL-RD 2000 E EC HL-RD 3000 E ЕС

Bar Fridge USER MANUAL MB46W

Axial intelligent fan USER S MANUAL

EH0554 Indoor Climate Control

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

AXIAL FANS user's manual. model Quiet

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

USER MANUAL TPS-M5/M55/M555

General safety precautions English

CENTRIFUGAL FANS user's manual. model VENTS VK.

INTELLIGENT AXIAL FAN user's manual

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

Operation Manual. Automatic Control System for Air Supply Ventilation Unit with Hydronic Coil Heat Exchanger

PC20-AMFII / PC40-AMF USER MANUAL

Ireland Australia New Zealand

General safety precautions English

Double Door - Dual Zone Wine Cooler

ISCG90SS _03 ISCG90SS

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual

MeacoCool MC Series Portable Air Conditioner

Split Portable Air Conditioner

EH0533 Indoor Climate Control

Installation instructions. and User guide. Designer wall glass canopy NZ AU. HC90CGX1 & HC60CGX1 models

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

Niles Steel Tank Hot Water Generator Installation and Operation Manual

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

13-1. Temperature Regulator

Portable Air Conditioner USER MANUAL

20L Electronic Dehumidifier

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

MeacoDry ABC Range Dehumidifiers

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

EBAC MODEL PD120 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

PORTABLE AIR CONDITIONER (LOCAL)

Meaco 10L small home dehumidifier Instructional Manual

Installation manual Mini Comfort 50 S/L 07/ V EN

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

INVERTER SPLIT - TYPE

39 HQ Air Handling Units AiroVision

Installation and Service Manual

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

MOBILE AIR CONDITIONER. User Manual PC15/20/26-BCB

Service Manual & Installation Manual

Please read all these instructions carefully before using this product.

ENTROPIE boiler TT300

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

Pump WaterVISE, FloVISE

Transcription:

DUCT COOLERS KWK KFK EN OPERATION MANUAL KWK_KFK_v2(4)_EN.indd 1 13.06.2016 13:35:29

CONTENTS 3 Introduction 3 General 3 Safety rules 3 Transportation and storage regulations 3 Manufacturer s warranty 3 Delivery set 4 Design 4 Technical data 5 Mounting 6 Condensate drainage 6 Technical maintenance 6 Troubleshooting and fault handling 7 Acceptance certificate 7 Connection certificate 7 Warranty card 2 KWK_KFK_v2(4)_EN.indd 2 13.06.2016 13:35:29

BLAUBERG Ventilatoren GmbH is happy to offer your attention the duct coolers. INTRODUCTION The present operation manual contains a technical description, technical data sheets, operation and mounting guidelines, safety precautions and warnings for safe and correct operation of the unit. Read carefully and understand the operation manual, especially the safety requirements, before the unit mounting and start up. Keep the operation manual available as long as you use the unit. GENERAL The duct coolers are designed for supply air cooling in supply or air handling units integrated into rectangular ventilation systems. The cooler is a component part and is not designed for independent operation. Each cooler is subjected to a pressure and a tightness test. The cooler is designed for operation in the cold and moderate climatic zones. The unit design is regularly improved, so some models can slightly differ from those ones described in this service instruction. SAFETY RULES While mounting and operating the cooler fulfil the user s manual requirements as well as the provisions of all the applicable local and national construction, electrical and technical norms and standards. Prior to turning the cooler on make sure that it is not damaged and does not contain any foreign objects inside. Make sure of no leakages in the connection points. Mounting and connecting of the cooler is allowed by a qualified electrician with a work permit for this type of operations. The cooled air must not contain solid, fibrous, sticky, aggressive substances that may provoke aluminium, copper and zinc corrosion. Fulfil the operation manual requirements to ensure a trouble-free and long service life of the unit. TRANSPORTATION AND STORAGE REGULATIONS Transportation of the unit is allowed by any vehicle provided the unit is transported in the original package and is protected against weather and mechanical damages. Use hoist machinery for handling and transportation to prevent possible mechanical damages of the unit. Fulfil the requirements for transportation of the specified cargo type during cargo-handling operations. Store the unit in a dry and cool place in the original packing. The storage environment must not be subjected to any aggressive and/ or chemical evaporation, admixtures, foreign objects that may provoke corrosion and damage connection tightness. Store the unit in an environment with minimized risk of mechanical damages, temperature and humidity fluctuations. Do not expose the unit to the temperatures below +10 C and above +40 C. MANUFACTURER S WARRANTY The unit complies with the requirements according to the EU norms and directives. The manufacturer hereby warrants normal operation of the unit over the period of two years from the retail sale date provided observance of the installation and operation regulations. In case of a failure due to a manufacturing fault during the warranty period the consumer has the right to exchange it. The replacement is offered by the Seller. If case of no confirmation of the purchase date, the warranty period shall be calculated from the manufacturing date. The MANUFACTURER is not responsible for any damage resulting from any misuse of or gross mechanical interference with the unit. The MANUFACTURER is not responsible for the damages resulted due to the use of third party equipment or to third party equipment.! WARNING The unit may not be operated by children or persons with reduced physical, mental or sensory capacities, or lacking the appropriate training. Supervise the children and do not let them play with the product. WARNING Do not dispose in domestic waste. The unit contains in part materials that can be recycled and in part substances that should not end up as domestic waste. Dispose of the unit once it has reached the end of its working life according to the regulations valid in your country. DELIVERY SET Cooler - 1 item; Operation manual - 1 item; Packing box - 1 item.! ATTENTION Make sure the unit has no visible transport damages while accepting the goods. Check the ordered and the delivered goods for compliance. 3 KWK_KFK_v2(4)_EN.indd 3 13.06.2016 13:35:30

DESIGN The cooler casing is made of polymer coated steel, the tube collectors are made of copper and the heat exchanger surface is made of aluminium plates. The cooler casing has a dismountable design that provides easy access to the heat exchanger and the droplet separator. The cooling coils are available in 3 rows modification. Direct evaporation cooler KFK: maximum operating pressure: 2.8 MPa (28 bar). The internal operating medium of the KFK duct cooler is an evaporating refrigerant, i.e. R123, R134a, R152a, R404a, R407c, R410a, R507, R12, R22. Duct water cooler KWK: maximum operating pressure: 1.5 MPa (15 bar). The internal operating medium of the KWK cooler is water or antifreeze. If necessary change the service side by turning the cooling coil through 180. By default the service side is on the right in the direction of the air flow. To attain the maximum cooling capacity the cooler must be connected on counter-flow basis. Counterflow connection Direct flow connection TECHNICAL DATA Table 1. Overall dimensions of the KWK cooler Model Dimensions [mm] B B1 В2 B3 H H1 H2 H3 H4 L K KWK 40х20-3 400 420 440 470 200 220 240 295 124 56 G 3/4 10.4 KWK 50х25-3 500 520 540 570 250 270 290 345 188 45 G 3/4 12.8 KWK 50х30-3 500 520 540 570 300 320 340 395 252 56 G 3/4 14.3 KWK 60х30-3 600 620 640 670 300 320 340 395 252 56 G 3/4 16 KWK 60х35-3 600 620 640 670 350 370 390 445 268 56 G 3/4 17.7 KWK 70х40-3 700 720 740 770 400 420 440 495 314 56 G 3/4 21.9 KWK 80х50-3 800 820 840 870 500 520 540 595 442 56 G 3/4 26.9 KWK 90х50-3 900 920 940 970 500 520 540 595 442 56 G 3/4 31.5 KWK 100х50-3 1000 1020 1040 1070 500 520 540 595 442 56 G 1 32 Weight [kg] 425 385 B3 80 113 H3 H2 H1 H ø9 8 holes K H4 B B1 B2 K L 129 Fig. 1. Overall dimensions of the KWK cooler 4 KWK_KFK_v2(4)_EN.indd 4 13.06.2016 13:35:30

Table 2. Overall dimensions of the KFK cooler Model Dimensions [mm] B B1 В2 B3 H H1 H2 H3 H4 L D1 D2 KFK 40х20-3 400 420 440 470 200 220 240 295 103 44 12 22 10.4 KFK 50х25-3 500 520 540 570 250 270 290 345 155 44 12 22 12.8 KFK 50х30-3 500 520 540 570 300 320 340 395 210 33 12 22 14.3 KFK 60х30-3 600 620 640 670 300 320 340 395 199 44 18 28 16 KFK 60х35-3 600 620 640 670 350 370 390 445 199 44 18 28 17.7 KFK 70х40-3 700 720 740 770 400 420 440 495 224 44 22 28 21.9 KFK 80х50-3 800 820 840 870 500 520 540 595 340 44 22 28 26.9 KFK 90х50-3 900 920 940 970 500 520 540 595 340 44 22 28 31.5 KFK 100х50-3 1000 1020 1040 1070 500 520 540 595 325 44 22 28 32 Weight [kg] 425 385 B3 80 115 H3 H2 H1 H ø9 8 holes ød1 H4 B B1 B2 ød2 L 135 Fig. 2. Overall dimensions of the KFK cooler MOUNTING The cooler is connected to the air duct with a flange connection. Outdoor installation of the cooler is allowed only if the refrigerant is antifreeze (ethylene glycol solution). During mounting consider the operating characteristics of the mixing unit actuator. While mounting the cooler provide quick and easy dismantling of the heat exchanger, drain pan and the drain pipe. The cooler can be installed only horizontally to enable condensate drainage. While mounting the cooler provide enough access for servicing and repair operations. The duct cooler may be installed upstream and downstream of the fan. If the cooler is installed downstream of the fan, provide at least 1-1.5 m air duct between the cooler and the fan for air flow stabilization. Prior to starting mounting check the tube, plates and the tube collector condition. Flanges of the system components are mounted with galvanized bolts and M8 nuts. Prior to starting operation and after a long downtime fill the U-trap with water. Negative pressure coolers can be equipped with a U-trap and a ball valve. Such U-trap must not be filled with water. 5 KWK_KFK_v2(4)_EN.indd 5 13.06.2016 13:35:31

CONDENSATE DRAINAGE A drain pan with a drain pipe connected to a sewage system is designed for condensate drainage. While selecting the U-trap dimension type consider the total fan pressure. The U-trap must ensure correct operation of the ventilation system. Connect the drain pipe, the U-trap (not included in the standard delivery set) and the sewage system with metal, plastic or rubber pipes. The pipe slope downwards must be at least 3. Before starting the cooler fill the system with water and check that the U-trap is always filled with water. Make sure that the water drainage is correct. Wrong connection to sewage system may result in condensate accumulation inside the cooler. The condensate drainage system is designed for operation at the ambient temperature above 0 C! If the ambient temperature is below 0 C, the condensate drainage system must be heat insulated and pre-heated. H, mm К, mm Р, Pa 100 55 600 200 105 1100 260 140 1400 H - U-trap height K - drain height P - total pressure in the fan TECHNICAL MAINTENANCE WARNING While cleaning the ribbed battery be careful not to damage the ribbed surface. Maintenance means regular preventive measures during operation. The aluminium ribs and the droplet separator must be cleaned at least once per year by vacuum cleaner or pressure water flushing. The cleaning periodicity depends on air pollution degree and maintenance quality of the filters and equipment. If the internal environment is clean enough, the cleaning may be performed more seldom, as required. The U-trap maintenance includes regular control of water level and sufficient U-trap and drain pipes clearance. TROUBLESHOOTING AND FAULT HANDLING Table 3. Faults and fault handling Fault Possible reason Troubleshooting Refrigerant leakage The tube collectors are damaged. Pipe connection is loose. Contact the Seller. Low air flow The heat exchanger and/or the droplet separator are soiled. Clean the heat exchanger and the droplet separator. Water leakage The drainage system is soiled, damaged or arranged not correctly. Clean the drain line. Check the drain line slope angle. Make sure that the U-trap is filled with water and the drain pipes are frost protected. 6 KWK_KFK_v2(4)_EN.indd 6 13.06.2016 13:35:31

ACCEPTANCE CERTIFICATE Duct cooler KFK 40х20-3 KFK 70х40-3 KWK 40х20-3 KWK 70х40-3 KFK 50х25-3 KFK 80х50-3 KWK 50х25-3 KWK 80х50-3 KFK 50х30-3 KFK 90х50-3 KWK 50х30-3 KWK 90х50-3 KFK 60х30-3 KFK 100х50-3 KWK 60х30-3 KWK 100х50-3 KFK 60х35-3 KWK 60х35-3 is recognized as serviceable. The unit complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU-Directives on Electromagnetic Compatibility. Approval mark Manufacturing date INSTALLATION CERTIFICATE Duct cooler KFK 40х20-3 KFK 70х40-3 KWK 40х20-3 KWK 70х40-3 KFK 50х25-3 KFK 80х50-3 KWK 50х25-3 KWK 80х50-3 KFK 50х30-3 KFK 90х50-3 KWK 50х30-3 KWK 90х50-3 KFK 60х30-3 KFK 100х50-3 KWK 60х30-3 KWK 100х50-3 KFK 60х35-3 KWK 60х35-3 Company is connected in compliance with the operation manual requirements by the professional: Name Date Signature WARRANTY CARD KFK 40х20-3 KFK 70х40-3 KWK 40х20-3 KWK 70х40-3 KFK 50х25-3 KFK 80х50-3 KWK 50х25-3 KWK 80х50-3 KFK 50х30-3 KFK 90х50-3 KWK 50х30-3 KWK 90х50-3 KFK 60х30-3 KFK 100х50-3 KWK 60х30-3 KWK 100х50-3 KFK 60х35-3 KWK 60х35-3 SALLER SALES DATE REPRESENTATIVE IN EU BLAUBERG Ventilatoren GmbH Aidenbachstr. 52a, D-81379 Munich, Germany 7 KWK_KFK_v2(4)_EN.indd 7 13.06.2016 13:35:31

KWK_KFK_v.2(4) / EN KWK_KFK_v2(4)_EN.indd 8 13.06.2016 13:35:31