FRL 10 Centrifugal blowers

Similar documents
Pentz EF5 Installation Guide

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

INLET DAMPER WALL FAN UNIT

CHAPTER 7 PARTS LISTS, SCHEMATIC DIAGRAMS AND WARRANTY

Dyna-Star HP or HF Pump 35# Pail Kit and Follower Plate

Installation Instructions

English BT3600

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

Engine Block Heater Service Kits (Tank Type) 30RZ/33RZ/45RZ (CSG 649 Ford Powered) Standby Generator Sets

Workman 3, 6, & 10-Gallon Wet/Dry Vacuums. Technical Information & Safety Page 3, 4

Workman 3, 6, & 10-Gallon Wet/Dry Vacuums. Technical Information & Safety Page 3, 4

Installation Instructions

Dean Pump High Temperature Chemical Process Inline Pumps

User s Manual and Operating Instructions

Installation Instructions

An ibuy Stores Company

User Manual Box Exhaust Fan Series (Belt Drive)

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

Installation Instructions Part No , Part No Part No

PACER 30 VACUUM IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE OPERATING OR SERVICING MACHINE

MIST MAX MODEL MM800. Important: Installation and Operation Manual

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

24 & 30 Quiet Design Oscillating Wall Mount Fan

SuperKlean Washdown Products

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

User s Manual and Operating Instructions

HORIZONTAL AGITATOR ASSEMBLY

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.

IB 835. Installation Manual. Integrated Bidet Toilet TABLE OF CONTENTS

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

TCUT10UL 2.5 HP 10 Tile Saw Assembly & Operating Instructions

MK-1080 PAVER SAW OWNER S MANUAL & PARTS MANUAL

AVANI Grinding Booth

BG6UL. 6 Inch Bench Grinder Assembly & Operating Instructions

Dayton Belt Drive Whole House Ventilating Fans

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

MK-1605 Electric Concrete Saw EXPLODED VIEW & PARTS LIST

Hustler Z Bac Vac Parts Manual ,

690 and Power Fishing Systems

150MM ELECTRIC EARTH BORER

SAN JUAN FRESH WATER COOLING SYSTEMS

568X, 587X, 588X Series

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Used with: Pre NT, 3P605NT Pre , 1006 Native Grass Pre PNG12, 3PNG15, 2SNG24, 2SNG30, NG12 Grass Seeder

Bead Roller Operating, Servicing, and Safety Instruction Manual

READ AND SAVE THESE INSTRUCTIONS

Group 13 Cooling System

Installation Instructions

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

LEAVE THIS MANUAL WITH HOMEOWNER

Rotary XL (558 Series) and Classic (548 Series)

MLG35 Parts Manual Phase 8

Marley Ultra Quiet Fan

Group 7 COOLING SYSTEM CONTENTS

Cable Drum Machine. Operation Manual 40 SERIES. Cleans 2" to 4" lines up to 75' N O T F O R R O O T S

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Series P. Installation & Maintenance. Materials: A - CPVC B - Polypropylene C - PVDF

Revised 9/05. Model X-750 Subassembly Parts List

MODEL X-150D SUB-ASSEMBLY PARTS LIST REV. 02/27/04

1600 Series Rotating Suction Screen

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

MK-100 JCS Tile Saw TILE SAW OWNER S MANUAL & OPERATING INSTRUCTIONS SERIAL NUMBER:

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

CHAPTER 7 PARTS LISTS, SCHEMATIC DIAGRAMS AND WARRANTY

Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627**

7165 Dust Collector Owner s Manual

DA-9270 TWIN NEEDLE (THREE NEEDLE) FEED OFF THE ARM DOUBLE CHAIN STITCHER. English

17" PRO BUFFERS. Operation l Care l Service. Caution! Read Safety and General Instructions carefully before using for the first time. REV.

ASTRO ENVELOPE FEEDER AMC FOR HEIDELBERG PRINTMASTER INSTALLATION AND OPERATING INSTRUCTIONS

CL & CLG Clamp Mount Mixers

NON-SUBMERSIBLE WATER PUMP

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

Table of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company.

INSTALLATION INSTRUCTIONS

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP)

INSTALLATION, OPERATION & MAINTENANCE MANUAL

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

TOOLS AND MATERIALS REQUIRED

Kongskilde Suction Blowers a Flexible and Dependable Conveying System

This label warns for risk of electrical shock when failing to observe.

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

Panel Fan Series Operators Manual (Galvanized and Polymer)

EdcoParts.com An ibuy Stores Company

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

JOHN DEERE X465, X475, X485, X495, X575, X585

Instructions for Installing the MMD Rear Window Louvers

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

Operating Instructions (ENG) MODEL: 115 V UL LISTING FOR 1/2 HP MODELS ONLY. Read instructions before operating the machine J 07/05/07

Flat Pack - Pioneer Platform. Important!

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

MFE400 SERVICE PARTS

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Universal Pioneer Platform (Flat Pack) 42114B/42115B

Transcription:

FRL 10 Centrifugal blowers User instructions

2

Kongskilde Blower model FRL10. Motor mounting instructions Motor Specifications: Model FRL 10 Blower/Aspirator fans are designed to be driven by Single or 3 phase, TEFC Electric Motors with a Horse Power Rating of 1.5 HP at 3500 RPM. and with a Frame Spec. of NEMA 56C Flange. (Shaft Dia. = 5/8", Shaft Length = 1 7/8", Key Size 3/16"sq. x 1 1/8" long). (Kongskilde FRL 10 Blowers are also available fully assembled with motors, see dealer for details and motor options). Motor Shaft Drilling. Note: Prior to assembling the blower housing and rotor to the motor, the motor shaft must be drilled and tapped to accept a 5/16"-18 UNC x 3/4" bolt and washers. (In some instances, motors supplied by the factory may have the shafts pre-drilled and tapped for an M8 x 20 mm Metric Bolt). Please refer to assembly instructions and diagram Detail A. Note: It is very important to drill and tap the motor shaft and to secure the rotor to the shaft with the bolt and washers as described in the assembly instructions. Assembly Instructions. Refer to assembly diagram. 1 Place the half housing on to the motor flange and rotate the housing to align the bolt holes. Note: Take care to consider what position is best for access to the motor wiring box when the blower is installed. 2 Mount the half housing to the motor with four 3/8" x 3/4" bolts and 3/8" lockwashers and tighten the bolts. 3 Install the fan rotor all the way on the motor shaft and insert the key. Do not tighten the set screw on the key at this time. 4 If the motor shaft extends beyond the end of the rotor, install a 5/8" x 1 1/4" x 1/4" spacer bushing over the end of the shaft. If the motor shaft does not extend past the rotor the spacer will not be needed. Note: In some cases you may need to shorten the key in order to allow the spacer to sit flush against the rotor busing. 5 Install the 5/16" (or M8) bolt, with both a large washer and lockwasher, in the end of the motor shaft and tighten. 6 Tighten the rotor set screw on the key. 7 Install the outer half housing over the rotor and attach the blower housings together with two M6 x 12 mm screws, serrated washers and nuts. Place one bolt in the hole nearest to the blower outlet on each side of the housing. 8 Install the bolt tightener bracket on the bottom side of the blower housing with the M6 x 16 mm screw, serrated washer and nut. 9 Install the housing clamp with the M6 x 16 mm screw, serrated washer and nut. Start at the fixed end on the top side of the fan housing, and carefully wrap the clamp around the seam to seal the housings together. 10 Insert the M8 x 70 mm tightener bolt with 1 washer, through the tightener bracket and the end of the housing clamp. Install a second washer and secure with nut. 11 Slowly draw the clamp around the housing with the tightener bolt. Note: Lightly tap the clamp with a rubber mallet along the edge of the seam to firmly seal the housings together and secure the bolt and nut. 12 If the fan inlet will be exposed during operation install the finger guard grill with the OK160 bolt clamp provided. Note: If optional stand is used - attach stand to blower then install finger guard grill to the stand with OK160 clamp provided. 3

4

Safety precautions. Warning! Operating the blower without the finger guard in place may result in serious injury. Keep hands, fingers and loose clothing away from the blower inlet and outlet at all times! Never look or place hands into the airstream, blower outlet or other air/material discharge points to check for restrictions! Never insert anything into the blower inlet or outlet to clean or dislodge foreign material from the fan rotor. Always disconnect the blower from the power supply and check to insure that the rotor has come to a complete stop before cleaning or servicing the unit! 5

6

Fig. Part no. Pieces Notes 1 100 551 011 1.5HP-1PH-56C-3500RPM-115/230V 100 551 046 1.5HP-3PH-56C-3450RPM-230/460V 100 551 047 1.5HP-3PH-56C-3450RPM-575V 1A Motor key 3/16" x 1 1/8" 2 100 382 051 3/8" lock washer 3 100 356 025 3/8" x 3/4" bolt - GR.5 4 100 315 028 Nut M6 5 100 332 002 Star washer M6 6 131 013 016 FRL10 half housing - motor side for 56C flange 7 131 011 088 FRL10 half housing - air intake side 8 100 321 014 Posi-drive screw M6 x 12 mm 9 100 322 000 Stop screw M6 x 6 mm 10 131 012 013 Rotor - FRL10 high output: D=305 mm, d=5/8" bore 11 131 013 018 Rotor - Standard FRL10: D=265 mm, d=5/8" bore 12 131 011 049 Bolt bracket plated 13 100 323 002 Round head screw M8 x 70 mm 14 100 315 012 Nut M8 15 131 011 011 Housing clamp 16 100 321 015 Screw M6 x 15 mm 17 121 220 256 Spacer bushing 5/8" I.D. x 1 1/4" O.D. x 1/4" THK. (Not always used) 18 100 331 005 Washer M8 19 100 332 003 Star washer M8 20 100 304 012 Set screw M8 x 20 mm 100 356 108 Set screw 5/16" x 3/4" 21 131 010 129 Air intake screen - Finger guard 22 122 000 599 Bolt clamp OK160 - Grey 23 122 000 824 Quick release clamp OK160 - Grey 24 100 316 000 Wing nut M6 25 100 331 013 Washer M6 26 100 311 001 Coach bolt with nut M6 x 20 mm 27 122 000 689 OK160 air regulator for FRL10. (Items 24-27) 28 131 011 035 FLR10 floor stand 7

121 220 270 You can always find the latest version of the manuals at 30.05.2018 www.kongskilde-industries.com Kongskilde Industries A/S Tel. +45 33 68 35 00 mail@kongskilde-industries.com www.kongskilde-industries.com