TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Similar documents
LF /2. Fire Alarm Control Panel. Features:

Intelligent Single Loop Fire Alarm Control Panel

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Intelligent addressable fire alarm control panel

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

Advanced FireAlarm Panel 1-4Loop

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Different types of Fire Alarm System

NETWORK FIRE ALARM CONTROL PANEL. Features

SUPREMATouch. Modular Fire & Gas Detection System

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Fire control panel detect 3004 plus and accessories

Sita200plus. 200detectors. Single loop analogue addressable System

INTELLIGENT FIRE ALARM CONTROL PANEL

intelligent fire alarm ID60series panels

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Conventional Releasing Control Panel

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

SUPREMATouch. Modular Fire & Gas Detection System

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

ID3000 intelligent. fire alarm panel

Addressable Fire Alarm Control Panel

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Cover Inside Front & Back

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

ID3000 intelligent. fire alarm panel

ID50series. intelligent fire alarm panels

Addressable Fire Alarm Control System 2100 series

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Product Data Sheet. Remote Terminals. Features:

600 Range Dialer Installation Manual. Version 1.0

561-MB256 plus. Intruder alarm control panel. Performance features

DCS-100. intelligent damper control & monitoring system

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Solution F2. Fire Alarm Control Panels one step ahead.

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Industrial Grade Gas Detection Detecting The Difference

Intelligent Addressable Fire Alarm System

Why Hart XL Aspirating Smoke Detection?

The EN54 Part 2, 4 and 13 Fire System

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

SALES SUPPORT DOCUMENT

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

REPEATER FS5200R INSTRUCTION MANUAL

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

Reliably Advanced Extinguishing Control

Laptop / PC Programming Manual

Desigo TM Fire Safety System A comprehensive fire-protection system

APPLICATION DATA SHEET

30.45 Electric Release PDRP-2001

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

CODESEC FIRE ALARM SYSTEMS. security technologies

YOUR PARTNER IN FIRE & GAS DETECTION

Industrial Grade Gas Detection

Cerberus PRO A comprehensive fire-protection system

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

Fire Alarm System Fundamentals

XC10 Extinguishing control panels

HRX3000. Technical Manual

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

On the job around the clock 24/7: Fire detection systems

Product Information. PipeMonitor District Heating Monitoring with Leak Localisation

FireNET Plus Wiring Instructions

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Bionics Instrument. Alarm Handling. Gas Alarm Systems

Touch Screen 1 loop Addressable Fire Alarm Panel

ID2000. intelligent fire alarm panel

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

MCS 4000 Control Panel

For Complete Fire and Gas Solutions

OPEN SPRINKLER SYSTEM

Desigo TM Fire Safety System A comprehensive fire-protection system

HRX Technical Manual. Version 1.2

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

Fire Control Panel FS5100

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

561-MB48. Intruder Alarm Control Panel

Solution F1. Fire Control Panels the new generation

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

Orion ISS. Intrusion and Fire Alarm Panel. Signal-10. User s Manual

CATALOG NUMBER. Features. Description

Multiple Input and Output Modules

WASTEWATER Online UV%Transmission Analyzer

FW106 Fire Alarm Control Panel

IGD.CO.UK

Transcription:

FEATURES: Closed Loop Design (Class A Wiring) Microprocessor Based System Intelligent Distributed System Structure Quick Response Time Fire Alarm in <1 Second Capacity of 25 Addressable Devices 1-2 Intelligent Detection Circuits Up to 127 Devices per Loop Dynamic Supervision Fully Field Programmable 5 LCD Display 20x20DPI Resolution 21 Key User Friendly Control Switches 15 LED Status Indicators Menu Driven Functions Up to 5 Secure and Independent Module Control Function RS85 Communication for Fire Repeater Display Panel and CRT System. CAN Bus Communication for networking Laptop Programming Level System Password Protection Logic Controlled Output Functions Circular History Event Flash Memory Storage Graphic Workstation Interface Up to 80 Network Nodes on a Single Graphic Workstation Data Transfer Speed and Reliability High Performance at Low Cost Wall Mount Enclosures

DESCRIPTION: The 1/2 distributed intelligent fire alarm control panel is a microprocessor based advanced detection and protection system. With its flexibility, unique design and ability to utilize both intelligent and conventional devices, makes it a very reliable system for life safety use. It adopts the use of a multi-line LCD screen for ease of viewing of events and controls, RTOS (Real Time Operating System), for real time monitoring and display of events, and a graphical display for user-friendly menu and control operation as well as ease of identifying information being sent by field devices to the Fire Alarm Controller. The LF-6100 s design widely applies to all kinds of industrial and commercial constructions with its high resistance to humidity, wide operating temperature range, high reliability and ease of installation and configuration. With its user-friendly interface, the controller also adopts easy to identify function switches and status LED s that even untrained operators can understand and properly respond to the event that occurred (switches and LED s explained further on the succeeding page). History recording is also an integral part of the system. All data is stored inside the system s flash memory and can be viewed or printed at any time using the event browser. A stored history event adopts the circular type storage wherein the oldest data gets deleted in replacement of new incoming data when memory buffer is full. Maximum capacity of history memory is approximated at 999 events. The controller can accommodate up to 2 loops - 500 addressable points at the most which is adequate enough for small to medium sized life safety applications. Each device has a code that is to be set using the LF-DP-6190 Device Programmer. An Auto-Learn feature for devices is also present in the system. The controller analyzes the environment on which the detection devices are installed and adjust the detector s actuation level accordingly. It also utilizes a specialized loop circuit design, in which the device s transmitted data is sorted out based on its priority. The information with the highest priority would transfer first. Other information from the field devices up to the controller shall be processed accordingly which ensures a rapid and efficient response of the system. Fire Alarm from a field device is transmitted in less than 1 second. A secure direct link control panel can also be installed for up to 5 critical facilities which are mainly used to start or stop an exterior device independently even upon failure of the main fire alarm controller. It is used for critical elements such as fire pumps, smoke control fans or other facilities which requires direct control even upon failure of the system s processor. It is totally independent from the main controller but has the same functionality for monitoring alarm and line faults. The direct link control panel is secured with a lock and key for access restriction.

WIRING: Minimum Wiring Requirements: - Detection Loop and Module Control Loop 2 x 1.5mm² - 2V DC Power 2 x 2.5 wire 2V GND 2V DC Output (0.5A) NAC+ NAC- Notification Alarm Circuit (Conventional Type) C1+ C1- Control Output 1 CH CL CAN Bus (Networking) C2+ C2- Control Output 2 MA MB PC Programming Port C+ C- Control Output FA FB RS85 Communication Line (Fire Repeater, CRT Graphics) C+ C- Control Output YA1 YA2 Fault Voltage-Free Output Contact (0V DC, 5A) C5+ C5- Control Output 5 KA1 KA2 Fire Voltage-Free Output Contact (0V DC, 5A) T1+ T1- Loop 1 "OUT" T2+ T2- Loop 2 "OUT" T+ T- Loop 1 "IN" T+ T- Loop 2 "IN" DIMENSIONAL DETAILS: 80 External Wiring Terminals 80 190 50 R R5 290 297 8 25 100 75 R11 80 80 50 70 95 80 R5 R15 Fire Alarm Control Panel Note: All dimensions are in millimeters 5

TYPICAL NETWORKING DIAGRAM: RS-22 RS-85 CAN Bus...up to 20 FACP (Max km) 1 2 CRT Graphics Worksation RS-22 RS-85 CAN Bus...up to 20 FACP (Max km) NETWORK USING RS-22 WITH CRT GRAPHICS RS-22 RS-85 RS-85...up to 20 FACP (Max. 1.5km) 1 2 Lichfield Fire & Safety Equipment Co., Ltd. U.K. LF-6100 / CRT Graphics Worksation RS-22 RS-85 RS-85...up to 20 FACP (Max. 1.5km) LF-6100 / 6

TECHNICAL SPECIFICATION: Detector Loops 1-2 Loops Loop Capacity 127 address points for each loop Max Capacity 25 addresses points Main Power Supply AC 220V (+10%~-15%), 50Hz Back-up Power Supply DC 2V, 7AH (built-in) Power Consumption Supervising status: <W; alarm status: <10W (all 25 units fire detectors are in fire alarm status) External Control Unit 5 External Control Unit Contact DC 0V, 1A Capacity Polling Cycle 10 seconds (single point continues searching in abnormal situation) Signal Transmission Distance 1000m (2x1.5mm²); 1500m (2x2.5mm²) Alarm Line Wiring Method 2 wire loop Voltage in Alarm Bus 2V (18V~26V) Operating Temperature 0 C ~ +55 C Relative Humidity 95% Event Storage Capacity Up to 999 events Associated Operation Programmable 100 including OR1, OR2 & AND logic. Number Fire Alarm Output Relay 1 set (KA1, KA2) voltage free contact, normally open Fault Output Relay 1 set (YA1, YA2) voltage free contact, normally open Network Interface CAN Bus, RS-85 Dimensions 80 x 80 x 100mm ORDERING INFORMATION Model Number / 1 / 2 Description 1 Loop - 127 Devices Fire Alarm Control Panel 2 Loops - 25 Devices Fire Alarm Control Panel 7