System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

Similar documents
55 years of know how on flame monitoring systems from Leipzig

Flame Monitors BROCHURE

COMPACT FLAME CONTROLLER CFC 2000

COMPACT FLAME CONTROLLER CFC 1000

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Symphony Plus Combustion instruments

Products Catalog. Flame Monitoring & Evaluation Systems

ABB. Measure IT Uvisor System Dual sensor flame scanner. UR460 Mod. UVIR /ER/EF/DV Flame Scanner Product Data Sheet (rev B)

Gas Controller Module GC-06

Dräger Polytron 7000 Fixed gas detector

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

SUPREMATouch Modular Fire & Gas Detection System

Product Overview Combustion Technology

COMPACT FLAME CONTROLLER CFC 100

Engineering Guideline. pac- Carriers Type Universal

Technical Data. Dimensions

Chemical Processes in the Combustion

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

Dräger Flame 2350 (UV&IR) Flame Detection

ABB. Measure IT Uvisor System Flame scanner for gas and oil burners. UR450 Mod UV flame scanner Product Data Sheet (Rev. B)

Products Catalog. Flame Monitoring & Evaluation Systems

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

Product Overview Combustion Technology

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

Dräger Flame 2370 (UV&IR) Flame Detection

Panel Mounted Fault Annunciator Series

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Industrial fire alarm systems

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Dräger REGARD 3900 Series Control System

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Dräger Polytron 8310 IR Detection of flammable gases and vapour

On the job around the clock 24/7: Fire detection systems

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

ABB. Measure IT Uvisor System Flame scanner for fuel oil and coal flame. UR600 IR Mod flame scanner Product Data Sheet (rev.

Burner control unit BCU 370

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

UV - flame detector dual fuel burners for intermittent burner operations

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Process Alarm Solutions

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

Technical Data. Dimensions

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations

Burner control unit PFU 780

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Annex to: IECEx ULD U Issue. No. 2 Manufacturer: Detector Electronics Corporation Electrical apparatus: Eagle Quantum Premier system Modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Fire and Gas Monitoring Panel ST7-HV

Burner control unit BCU 370

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger Flame 2100 (UV) Flame Detection

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Panel Mounted Fault Annunciator Series

Power Flame Incorporated

Dräger Polytron 8000 Stationary gas detector (EC)

IFD-E Flame Detector User Manual

FLAME AMPLIFIER MODULE 3001D

Danfoss gas detection units

Dräger Flame 2100 Flame Detection

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

MBCE-110/230UV Flame Sensor Module

Dräger Flame 2500 (IR3) Flame Detection

Dräger Polytron 8100 EC Detection of toxic gases and vapors

FLAME AMPLIFIER MODULE 3001

Dräger Flame 2500 Flame Detection

Honeywell SLATE ICM Platform

Dräger Flame 2700 (Multi-IR) Flame Detection

Danfoss gas detection units

FIRERAY 5000 range USER GUIDE

For Complete Fire and Gas Solutions

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Dräger Polytron 8720 IR Detection of carbon dioxide

IFD-E Flame Detector User Manual

Detection, Protection, Innovation

Dräger PointGard 2100 Detection of toxic gases and vapours

ECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys

Level gauges Series LS Level indicator, switch and transmitter for liquids

Burner control units BCU 480

Model D12-IR. Digital Gas Transmitter...

Technical Data. General specifications. Rated operating distance s n 5 mm

Burner control units BCU 480

Dependable Solutions for Gas Detection

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

MSA Fixed Gas & Flame Detection for the Automotive Industry

W-FLAME IR/UV FLAME DETECTOR

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

GMA200-MW4. User Manual. Gas detection controller for wall mounting

GasGard 100 Control System

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

Transcription:

System Overview F300K Compact Flame Scanner Sensors and systems for combustion engineering www.lamtec.de

LAMTEC F300K Compact Flame Scanner Approvals. 0085 Gas Appliances Directive 2009/142/EC, CE0085 0036 Pressure Equipment Directive 2014/68/EU, CE0036 SIL-3 SIL 3 Confirmation, DIN EN 61508 Parts 1-7 CSA-C22.2 No. 199 Class I, Division 2, Group A, B, C, D, Hazardous Locations EN 60079, Ex Device Group II Device Category 3, IBExU12ATEX Ex na nc ic IIC T5 (T6) Gc X (Zone 2) 2

The new generation of flame monitoring. An innovative and versatile flame scanner for a wide range of applications that can address virtually any control task. This is the next generation of flame monitoring. The new F300K compact flame scanner from LAMTEC now offers operators of industrial furnaces and power stations a high-end product that meets the high demands of complex furnaces safely, reliably and effectively. The LAMTEC F300K flame scanner in operation. Advanced Flame Rating (EFA) 5 Flame intensities 3 RMS values of the sensor signal (sum/uv/ir) Output of all signals via gateway Detection of unstable conditions before loss of flame (e.g. high recirculation rate) Advantages: Microprocessor flame monitoring in a compact design Integrated flame sensor, amplifier and flame relay Flame self-learning function ON/OFF Digital flame frequency evaluation in 14 selectable ranges (5 to 210 Hz) Three selectable operating modes Remote software with diagnostics function Standard version certified for Ex Zone II SIL 3-40 C... + 85 C (higher temperatures possible, with the cooling air housing) IP67 Applications: Combustion systems with and without selection tasks Single and multi-fuel burners Combustion chamber monitoring Power plants, heating plants, process furnaces, waste combustion plants, etc. Combustion plants with restricted view of the flame Fuel: Gas Oil Coal Biomass Process waste gases Dust of all kinds Special fuels Chemical residues www.lamtec.de 3

LAMTEC F300K Compact Flame Scanner F300K-FO with Fibre Optic For use on boiler systems with limited view of the flame Use at high temperatures in the normal growing range of a flame monitor and up to 350 C Summary: 3 Operating modes, can be externally preselected, switchable during operation 14 Graduated frequency ranges Available as single or double sensor (IR/UV) Can be operated via four buttons Flame ON/OFF LED, fault, flame intensity, operating modes Can be completely operated without opening the device, which means that the same degree of protection IP67 is retained, even during commissioning Menu-guided configuration and commissioning with Flame ON/OFF self-learning function Alignment assistance by means of a logical graphical display of flame data Switching threshold can be individually adjusted in the entire signal range, 13 pre-selectable amplification levels Easy operation via graphic user interface with status display (optional) Field bus interfaces: MODBUS TCP (client/server) MODBUS RTU (master/slave) Ethernet (Frame) PROFIBUS (Slave) CANopen Indepth analysis via F300K remote software (optional) Read, write and store parameter records from multiple F300K devices via CAN-Bus Analysis via the simulation of different parameterisations Periodical signals, including the network frequency and their harmonic components are identified. No adjustment of countryspecific network frequencies needed Analogue output 0/4... 20 ma, configurable for flame intensity or RMS value of the sensor signal Parameter setting capability of switching threshold, frequency range, etc. based on operating mode Download, back-up and upload of parameter records in the user interface Device selection via menu control Operation and commissioning 2 operating levels for the commissioning: Standard and expert, password-protected Simulation of switching behaviour, What would happen if?, to assist in setting the Flame ON/OFF parameters with optional user interface or PC remote software Extended flame rating (optional) Additional output of: Up to 5 flame intensities Up to 3 RMS values of the sensor signal 4

Product description. The F300K is available in two versions. F300K with LED display. 1 5 2 4 3 F300K with LED display. There are two versions of the F300K; LED display and control unit display. The LED display version offers basic operational visualisation including flame status, operating mode and intensity. The control unit display allows full configuration and parameter setting. The functionality of both units is identical. F300K display unit with LED display. 1 LED in the display bar indicates the intensity of the flame as a dotted display: chain of 2 x yellow and 3 x green; middle LED flashing = warning. 2 LED green = operating mode 3. 3 LED green = operating mode 2. 4 LED green = operating mode 1. 5 LED red = flame OFF/ready for operation flashes in the event of a fault. F300K with user interface (UI). 1 2 7 3 4 6 5 F300K with UI. Integrated graphic user interface for menu-driven configuration, commissioning and operating simulation of the switch response with What would happen if?. Data back-up/download and upload of the configuration and setting. F300K operating and display unit with UI. 1 Display. 2 LED on and red = flame OFF/ready for operation flashing red = fault. 3 LED on and green = flame ON, LED flashing green = fault. 4 ENTER key. 5 UP key. 6 DOWN key. 7 ESC/BACK key. www.lamtec.de 5

LAMTEC F300K Compact Flame Scanner F300K with LED Remote external user interface FSB Remote PC FSB/ USB module FSB- Gateway Field bus: PROFIBUS (Slave) MODBUS TCP MODBUS RTU Ethernet (Frame) CANopen Example: Networking with an F300K. F300K with UI F300K with LED F300K with UI Remote external user interface FSB Remote PC Repeater FSB/ USB module FSB- Gateway Field bus: PROFIBUS (Slave) MODBUS TCP MODBUS RTU Ethernet (Frame) CANopen Example: Networking of multiple F300Ks. Selection criteria The spectral sensitivity of the flame scanners determines their suitability for specific fuels. Overview of suitable flame scanners: The suitability of the device types may differ from that indicated in the table depending on particular circumstances. Typ Spectrum/nm Approx. view angle Preferred applications/fuels F300K UV-4 215... 360 8 Oil Gas Dust Special applications in combination with fibre optics Special gases such as refinery gases, blast furnace gases and hydrogen F300K UV-4.6 215... 360 8 Special applications in combination with fibre optics F300K IR-2 850 1200 20 Combustion space monitoring F300K IR-3 1000 1700 60 Oil, gas, wood, coal and dust-fired furnaces with a high level of flue-gas recirculation Yellowish waste gases without UV radiation or with shielding of the UV spectrum by water vapour and dust F300K IR-4 1000... 2200 60 F300K UVIR-1 215... 360 850... 1700 8 8 UV: Oil, gas, special gases like refi nery gases and furnace gases IR: Oil, gas, wood, coal, dust furnaces with strong FGR Waste gases with yellowish colour without UV radiation or with shielding of UV components using water vapour and dust Special applications in combination with fibre optics 6

Accessories. Power supplies FN30-00, FN30-10, FN30-20, FN30-30 The FN30 power supply is available in four different versions. Versions FN30-20 and FN30-30 are equipped with output/coupling relay and fulfil the requirements of EN298 and conform to SIL 2 in accordance with EN61508. Cooling air housing and adjustment bracket FK41 You will find a complete overview of the holders and cooling-air housings (also with extended air outlet) for LAMTEC flame scanners in the document Flame Monitoring Systems and Accessories (DLT7660). Alternatively, a standard power supply with an output voltage of 24 V that meets the protective separation requirements can be used. Power supply FN30 is designed for top rail mounting, but is also available in an integrated housing. Cooling air housing and adjustment bracket FN30-00 for top rail mounting. Connection cable Connecting cables are available in 3, 5 and 10 metre lengths. Standard LiYcY cable, temperature range of -40... +80 C (inactive) silicone cable, temperature range -40... +150 C For special ambient conditions, the silicone cable can also be supplied with a stainless steel metal protected tube IP67 Flame-scanner testing device You can use the FFP30 to test that your flame scanner is working properly. The testing device simulates a variable flame frequency. The testing device is screwed onto the flame scanner, and the IR or UV beam activated via a rocker switch. The F200K must be set to an adequate sensitivity to detect the flame simulation. It is designed to test all flame scanners from LAMTEC. Flame-scanner testing device www.lamtec.de 7

LAMTEC F300K Compact Flame Scanner FG30-00 and FG30-20 connection housings LAMTEC offers two versions of the FG30 connection housing: FG30-00 with four cable glands and an M12 circular connector for FSB FG30-20 Ex II for use in explosion-hazard areas with four cable glands and an M12 circular connector for FSB II 3G EX na II T4 Gc X IP66 Externes User Interface (UI) FB30 Functions as for the integrated user interface A control unit can be coupled simultaneously with one or more F300K devices The control unit can be connected directly via the connection housing Power supply from the supply to the F300K (24 VDC) FG30-00 & FG30-20 Ex housing Fibre Optic Available versions: Rigid Protective Housing - FOR Flexible Protective Housing - FOF Available lengths: UI FB30 FSB adapter If there is no option for connecting the FSB, e.g. via a connection housing, the FSB adapter can be integrated between the F300K and connection cable. FOR 1.0 m to 10 m / 0.5 m graduation FOF 1.5 m to 10 m / 0.5 m graduation FSB adapter Fiber Optik Systeme 8

FSB gateway Via the FSB-Gateway an interface to the control technology can be implemented Data from one or from up to F300K devices can easily be sent via a control technology field bus F300K Remote Software Connection to the PC via FSB/USB module and adapter cables The F300K remote so ware permits the full parameter setting of an F300K. In addition, it also offers analysis, data backup and recording functions In addition to the F300K data, you can also connect up and record external, analogue and/or digital data by means of FSB modules. All of the data is synchronised FSB gateway FSB gateway is available for the following field buses: PROFIBUS (slave) MODBUS TCP (client/server) MODBUS RTU (master/slave) Ethernet (Frame) CANopen F300K Remote Software Repeater One repeater is required for a total FSB line length of over 80 m By the use of multiple repeaters, up to 32 flame scanners with a line length of several 100 m can be coupled via a bus system. Advanced Flame Rating Software + Module 5 Flame intensities 3 RMS values of the sensor signal (sum/uv/ir) Output of all signals via gateway Analog output of all signals RMS value output Repeater Advanced Flame Rating Software and Module www.lamtec.de 9

LAMTEC F300K Compact Flame Scanner Notes. 10

Notes. www.lamtec.de 11

LAMTEC Kompakt-Flammenwächter F300K LAMTEC Meß- und Regeltechnik für Feuerungen GmbH & Co. KG Wiesenstraße 6 D-69190 Walldorf Telefon: +49 (0) 6227 6052-0 Telefax: +49 (0) 6227 6052-57 info@lamtec.de www.lamtec.de Publication no. DLT7651-18-aEN-010 Printed in Germany I Copyright 2018 LAMTEC