REACH-IN INCUBATOR MODEL: RI28/RI40 2/ INSTALLATION AND OPERATIONAL MANUAL

Similar documents
INCUBATORS MODELS: 1525, 1535, 1545, 1555, 1565 GENERAL PURPOSE INCUBATORS INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL

VACUUM OVENS MODEL: 1410MS,1430MS, 1450MS INSTALLATION AND OPERATIONAL MANUAL

INSTALLATION AND OPERATION MANUAL

BOD INCUBATORS MODELS: LI20 Installation And Operations Manual REV 05/

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

VACUUM OVENS MODEL: , , INSTALLATION AND OPERATIONAL MANUAL

VACUUM OVEN MODEL: 1425, 1445 & idealvac.com (505)

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

SHC10R-2 SHC28-2 SHC28R-2 INSTALLATION AND OPERATION INSTRUCTIONS SHC10R SHC28 SHC28R HUMIDITY CHAMBER. Revised March 19,

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Revised 01/

HORIZONTAL AIR FLOW CLEAN ROOM OVEN

INSTALLATION AND OPERATION MANUAL

FS Series Forced Air Ovens. Operation and Service Manual

ECONOMY OVENS MODELS: 1310, 1320, 1321F, 1324, 1325F, 1326, 1327F INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL

LOW TEMPERATURE INCUBATOR MODEL: 2005 INSTALLATION AND OPERATIONAL MANUAL. Revised 1/

BOD INCUBATORS MODELS: LI6P/LI6P-2 LI20P/LI20P-2 Installation and Operations Manual /12

HUMIDITY CHAMBER MODELS: 9005 / 9010 / 9005L / 9010L WITH MICRO PROCESSOR CONTROL INSTALLATION AND OPERATION INSTRUCTIONS REV.

WATER BATHS GENERAL PURPOSE MODELS: 1265PC, 1275PC, 1285PC MICROPROCESSOR CONTROLLED INSTALLATION AND OPERATION MANUAL

BEAD BATH. MODELS: , , & , , & V/ V Models INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL

ENVIRONMENTAL HUMIDITY CHAMBER MODEL: HC6-2 INSTALLATION AND OPERATIONAL MANUAL REV. 11/

Connection Instructions: Welch 2042 Vacuum Pump To TVO-2 Vacuum Oven

HORIZONTAL AIR FLOW OVENS MODEL: 1601, 1602, 1605, 1670, 1675, 1680, 1685, 1690

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

AWR-460DB 46 Bottle Built-In Compressor Wine Cooler

DROSOPHILA SPECIFIC INCUBATORS MODEL: LIFLY & LIFLY-VIEW Installation and operations manual

DROSOPHILA SPECIFIC INCUBATORS SRI21F SRI21F-2 Previously designated LIFLY LIFLY-2 Installation and operations manual. Revised 4/

InstructIon Manual KrEs EQuIPMEnt stands

Models: SSI5 SSI5-2 SSI5R SSI5R-2

Reacti-Therm I and III Heating Modules

Reacti-Therm I and III Heating/Stirring Modules

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

OPERATING INSTRUCTIONS

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Mobile Hot Food Merchandiser Series. Series: MHB Operation Manual

INSTRUCTION MANUAL. UNDERCOUNTER WINE & BEVERAGE COOLER (32 bottles capacity) MODEL:WC-30U

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

TTT Digital Incubator

Spa Control System OWNER S MANUAL

Corning LSE 6L Digital Water Bath

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

INSTRUCTIONS FOR OPERATION AND CARE OF

LOW TEMPERATURE DIURNAL ILLUMINATION INCUBATOR MODEL: INSTALLATION AND OPERATION MANUAL Revised 11/

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

Isotemp Plus General Purpose Laboratory Freezers

THE ALTON CEILING FAN INSTALLATION INSTRUCTIONS

CONVEYOR TOASTER MODEL QCS QCS Installation and Operation Instructions 2M-HG0657 Rev. D 6/13/05

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Instruction Manual Item No.: V~, 60Hz

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

Thermostats. Digital Non-Programmable. GEAppliances.com. Owner s Manual & Installation Instructions RAK148D2 RAK164D2

Instruction Manual Item No.: V~, 60Hz

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

Wax Base Heater & Dispenser

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

1585/1585R Orbital Shaking Incubator Operational Manual Sheldon Manufacturing Inc. INTERNET:

ELECTRIC FIREPLACE OWNER S MANUAL

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

THE NIKKO CEILING FAN INSTALLATION INSTRUCTIONS

Operating Instructions

OPERATING INSTRUCTIONS

Ui REFRIGERATOR SPEC SHEET

OWNER S MANUAL. Important: Read carefully before assembly and use. PORTABLE CANISTER U #961A00007 ID111867

PORTABLE AIR CONDITIONER OWNER S MANUAL

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

B.I.C.A Built-In Coffee Appliance

OPERATIONS MAINTENANCE MANUAL

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

BioZone Scientific International contact information

XC Portable Air Conditioning

Refrigerated Incubator Model and Operating Instructions

Whynter Portable Ice Maker 33 lb capacity - White

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

23-IN Electric Logset

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

VACUUM OVEN MODEL: 1425, , , /

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

HB CDA SERIES WITH TEMPERATURE SETBACK

INSTRUCTION MANUAL. T-SERIES Air Conditioner. T29 Model Pentair Equipment Protection P/N McLean Parts 5736 N. Michigan Rd.

PORTABLE AIR CONDITIONER OWNER S MANUAL

EOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #

THE VALOR CEILING FAN INSTALLATION INSTRUCTIONS

OmniDry 2.9 Amp Centrifugal Air Mover

5) Do not start or stop the unit by inserting or pulling out the power plug.

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Model NT20e Installation Guide

USER S OPERATING AND INSTRUCTION MANUAL

AB-WINE18S Thermoelectric Wine Cooler OWNER S MANUAL Read and save these instructions.

Transcription:

REACH-IN INCUBATOR MODEL: RI28/RI40 2/13 4861573-1 INSTALLATION AND OPERATIONAL MANUAL Sheldon Manufacturing Inc. P.O. Box 627 Cornelius, Oregon 97113 EMAIL: tech@shellab.com INTERNET: http://www.shellab.com/~shellab 1-800-322-4897 (503) 640-3000 FAX (503) 640-1366

TABLE OF CONTENTS SECTION 1.0 SECTION 2.0 SECTION 3.0 SECTION 4.0 SECTION 5.0 SECTION 6.0 SECTION 7.0 SECTION 8.0 SECTION 9.0 RECEIVING AND INSPECTION INSTALLATION GRAPHIC SYMBOLS CONTROL OVERVIEW OPERATION CHART RECORDER INSTALLATION MAINTENANCE TROUBLESHOOTING PARTS LIST UNIT SPECIFICATIONS SCHEMATICS These units are general purpose incubators for professional, industrial or educational use where the preparation or testing of materials is done at approximately atmospheric pressure and no flammable, volatile or combustible materials are being heated. These units are not intended for hazardous or household locations or use. 2

RECEIVING AND INSPECTION Section 1 Your satisfaction and safety require a complete understanding of this unit. Read the instructions thoroughly and be sure all operators are given adequate training before attempting to put the unit in service. NOTE: This equipment must be used only for its intended application; any alterations or modifications will VOID your warranty. 1.1 Inspection: The carrier, when accepting shipment, also accepts responsibility for safe delivery and is liable for loss or damage. On delivery, inspect for visible exterior damage, note and describe on the freight bill any damage found, and enter your claim on the form supplied by the carrier. 1.2 Inspect for concealed loss or damage on the unit itself, both interior and exterior. If necessary, the carrier will arrange for official inspection to substantiate your claim. 1.3 Return Shipment: Save the shipping crate until you are sure all is well. If for any reason you must return the unit, first contact your customer representative for authorization. Supply nameplate data, including model number and serial number. Please see the manual cover for information on where to contact customer service. 1.4 Accessories: Verify that all of the equipment indicated on the packing slip is included with the unit. Carefully check all packaging before discarding. These units are equipped with 6 shelves, 24 shelf clips and 4 leveling feet. 3

INSTALLATION Section 2 Local city, county or other ordinances may govern the use of this equipment. If you have any questions about local requirements, please contact the appropriate local agency. Installation may be performed by the end user. Under normal circumstances this unit is intended for use indoors, at room temperatures between 5 and 40 C, at no greater than 80% Relative Humidity (at 25 C) and with a supply voltage that does not vary by more than 10%. Customer service should be contacted for operating conditions outside of these limits. 2.1 Power Source: The electrical supply circuit to the incubator must conform to all national and local electrical codes. Consult the incubator s serial data plate for the voltage and ampere requirements before making connection. VOLTAGE SHOULD NOT VARY MORE THAN 10% FROM THE SERIAL PLATE RATING. This unit is intended for 50/60 Hz application. A separate circuit is recommended to prevent possible loss of product due to overloading or failure of other equipment on the same circuit. 2.2 Location: When selecting a site for the incubator, consider all conditions which may affect performance, such as extreme heat from steam radiators, stoves, ovens autoclaves, etc. Avoid direct sun, fast-moving air currents, heating/cooling ducts, and high traffic areas. To ensure air circulation around the unit allow a minimum of 10cm between the unit and any walls or partitions which might obstruct free airflow. 2.3 Lifting / Handling: These units are heavy and care should be taken to use appropriate lifting devices that are sufficiently rated for these loads. Units should only be lifted from their bottom surfaces. Doors, handles and knobs are not adequate for lifting or stabilization. The unit should be completely restrained from tipping during lifting or transport. All moving parts, such as shelves and trays should be removed and doors need to be positively locked in the closed position during transfer to prevent shifting and damage. 2.4 Leveling: The unit must sit level and solidly. Leveling feet (supplied) are to be installed in the holes at the base of the incubator. Turn the leveling feet counterclockwise to raise level. If the unit must be moved, turn the leveling feet in all the way to prevent bending of the feet. 2.5 Cleaning: The incubator was cleaned at the factory, but not sterilized. Remove all interior parts, including shelves and shelf clips and clean all parts and the chamber with a disinfectant that is appropriate for your application. A thorough periodic cleaning is strongly recommended. WARNING: Never clean the unit with alcohol or flammable cleaners with the unit connected to the electrical supply. Always disconnect the unit from the electrical service when cleaning and assure all volatile or flammable cleaners are evaporated and dry before reattaching the unit to the power supply. 4

2.6 Place shelves into chamber at desired position. See Figure 1. Figure 1 5

GRAPHIC SYMBOLS Section 3 Your incubator is provided with a display of graphic symbols on the control panel which are designed to help identify the use and function of the adjustable components. 1. Indicates that you should consult your manual for further description and discussion of a control or user item. 2. Indicates Temperature 3. Indicates Overtemperature 4. C Indicates Degrees Centigrade 5. Indicates AC Power 6. Indicates Manual Adjustment 7. Indicates Potential Shock Hazard behind partition 8. Indicates Earth Ground 9. Indicates Unit should be recycled (Not disposed of in land-fill) 6

CONTROL PANEL OVERVIEW Section 4 4.1 Power Switch: The main power I/O (on/off) switch controls all power to the unit and must be in the I/ON position before any systems are operational. 4.2 Main Temperature Control: The Main Temperature Control consists of the digital display and UP/DOWN arrow pads for inputting set point temperatures and calibration. 4.3 HEATING Lamp: This green pilot lamp in ON when the unit is heating up to set point and is blinking when controlling temperature at set point. 4.4 Overtemperature Thermostat: Marked SET OVERTEMPERATURE, the Thermostat is a completely independent control that acts as an override in the event that the Main control fails in the ON position. The Thermostat will regulate chamber temperature at approximately 1 C above the set point of the Main controller. 4.5 OVER TEMP Lamp: This red pilot lamp is On when the Overtemperature Thermostat has taken control of the unit. Under normal operating conditions this lamp should never be on. 4.6 Circuit Breaker: (Non-CE units) Located adjacent to the power cord, the circuit breaker is an added measure of protection against power source variations that, if tripped, can be reset by pushing in the button once the reason for the interruption has been cleared. 4.7 Fuse: (CE units) Located adjacent to the power cord in place of the circuit breaker. The fuse is an added measure of protection against power source variations, and if blown must be replace once the source of the interruption has been cleared. 7

OPERATION Section 5 5.1 Check power supply against unit data plate, they must match. Plug service cord into the grounded electrical outlet, and turn the unit on. 5.2 Turn the Overtemperature Thermostat to its maximum position, clockwise, using a coin or a flat edged tool. 5.3 There are four (4) electrical outlets inside the chamber for use with electrical equipment not exceeding 1 amp. 5.4 Operating Electrical Apparatus Inside Chamber: Place the shaker, roller, spinner, etc. inside the incubator chamber. Plug apparatus into 1 amp outlet at rear of chamber. Be sure apparatus draws 1 amp or less (the power switch turns power on & off to outlets inside chamber). 5.5 Set Main Temperature Controller: Enter desired set point temperature. To enter set point mode on the controller, press either the Up or Down arrow pad one time. The digital display will start to blink, going from bright to dim. While blinking, the digital display is showing the set point. To change the set point, use the Up and Down arrow pads. If the arrow pads are not pressed for five (5) seconds, the display will stop blinking and will read the chamber temperature. Note that the Overtemperature Thermostat should be turned to its maximum position, (clockwise) until the unit has stabilized at desired set point temperature. Allow the incubator at least 24 hours to stabilize. 5.6 Calibration: It is recommended that calibration is done once the unit is installed in its working environment and has been stabile at set point for several hours. Place a certified reference thermometer in the chamber where it can be easily viewed through the window. Be certain the thermometer is not touching any shelving. Allow the temperature to stabilize again until the thermometer reads a constant value for one hour. Compare the digital display with the reference thermometer. If there is an unacceptable difference, put the display into calibration mode by pressing both the Up and Down arrow pads at the same time for five (5) seconds until the two outside decimal points begin to flash. While the decimal points are flashing the display can be calibrated by pressing the Up or Down arrow pads until the display reads the correct value. Allow the incubator temperature to stabilize again, and recalibrate if necessary. 5.7 Set Overtemperature Thermostat: As mentioned in step 5.2, the Overtemperature Thermostat should be initially set to its maximum position, to allow the unit to stabilize. Once the incubator is stabile at the desired set point, turn the Thermostat counterclockwise until the OVER TEMP light turns on. Next, turn the Thermostat clockwise just until the light turns off. Then turn the Thermostat clockwise two of the smallest divisions on its scale past the point where the light went out. This will set the Overtemperature Thermostat at approximately 1 C above Main temperature set point. 8

6 CHART RECORDER INSTALLATION Please note that the following information is a general guide for installation. Chart recorders are available from your dealer. Before attempting installation please read the instructions provided with your chart recorder thoroughly for specific installation instructions. Note: Unplug unit from the power supply before installing the Chart Recorder. 6.1 Remove cover for Chart Recorder, located on the right side of control panel. 6.2 Remove steel plate from the back of the Chart Recorder. Section 6.3 Open the front glass door on the Chart Recorder and loosen the two screws on the face of the recorder. (Screws are on the top and bottom right of the face.) 6.4 Inside the unit, behind the cover plate, you will see two wires that say Recorder Power. Cut off the butt connectors and strip the wires about 3/8 inch. 6.5 Put the Recorder Power wires through the hole in back of your Chart Recorder and connect the Recorder power wires to the terminal inside. 6.6 Run the Chart Recorder probe through the probe hole and slide into probe clips provided inside the chamber of the unit. 6.7 Inside the Chart Recorder you will see a piece of masking tape and a metal clip; remove these; screw face bolts back in; screw in Chart Recorder; shut the glass door on the Chart Recorder; plug unit into power supply; then turn on the unit. 6.8 In moving or mounting a chart, the pen arm and stylus must be raised by pressing on the tab at the uppermost end of the arm. Even if the recorder is not to be used, a fresh chart should be mounted or some sort of padding placed under the stylus to protect the sapphire tip. 6.9 To remove and replace a chart, unscrew the hub knob and swing it 90 clockwise, or to the 3 o clock position. Press the upper tab on the pen arm; lift the chart forward off the hub and slide down and away. DO NOT release the pen arm, but install a new chart. 6.10 Now the pen arm may be gently released and the chart knob rotated counterclockwise back to the hub. Align the proper chart time with the chart plate index. 9

MAINTENANCE Section 7 NOTE: Disconnect the power cord from the power source before performing any service or maintenance on this unit. 7.1 Cleaning: Clean the incubator interior and remove and clean shelves on a regular basis. Use a disinfectant that is suitable for your application. A thorough periodic cleaning is strongly recommended. Use care when cleaning the door gasket to prevent damage which could impair the positive door seal. WARNING: Never clean the unit with alcohol or flammable cleaners with the unit connected to the electrical supply. Always disconnect the unit from the electrical service when cleaning and assure all volatile or flammable cleaners are evaporated and dry before reattaching the unit to the power supply. 7.2 Storage: To prepare the unit for storage, remove all shelves and shelf clips and disconnect the power supply. Be certain that the chamber is clean and dry and the door is positively locked in the closed position. See Section 2.3, Lifting/Handling, for proper transport procedures. 7.3 No maintenance is required on the electrical components. If electrical or temperature problems occur, please see the Troubleshooting guide, Section 8.0, before calling for service. 10

TROUBLESHOOTING Section 8 FOR PERSONAL SAFETY, ALWAYS DISCONNECT THE POWER BEFORE SERVICING. Always make a visual inspection of the incubator and control panel when troubleshooting. Look for loose or disconnected wires that may be the source of trouble. Temperature too high-display and reference thermometer don t match Display reads "HI" or "400"+ Chamber temperature spikes over set point and then settles to set point TEMPERATURE 1/ Controller set too high-see section 5.5. 2/ Controller failed on call Customer Service. 3/ Wiring error call Customer Service. Probe is unplugged, is broken or wire to sensor is broken trace wire from display to probe; move wire and watch display to see intermittent problems. Temperature too low-display and reference thermometer don t match Display reads "LO" Unit will not heat over a temperature that is below set point Recalibrate see section 5.6. 1/ High limit set too low - see section 5.7 2/ Controller set too low see section 5.5. 3/ Unit not recovered from door opening wait for display to stop changing. 4/ Unit not recovered from power failure or being turned off incubators will need 24 hours to warm up and stabilize. 5/ Element failure see if HEATING light is on; compare current draw to data plate. 6/ Controller failure confirm with front panel lights that controller is calling for heat. 7/ Overtemperature failure confirm with front panel lights that Thermostat is operating correctly. 8/ Wiring problem check all functions and compare wiring to owner s manual especially around any areas recently worked on. 9/ Loose connection call Customer Service. 1/ If ambient temperature is lower than range of unit compare set points and ambient temperature to rated specifications in section 9.0. 2/ Sensor is plugged in backwards call Customer Service. 1/ Confirm that fan moving and that amperage and voltage match data plate check fan motor motion by removing top panel of the unit. 2/ Confirm that set point is set high enough turn Thermostat all the way clockwise and see if HEATING light or OVERTEMP light comes on. 11

Unit will not heat up at all Indicated chamber temperature unstable Will not maintain set point Display and reference thermometer don t match Can't adjust set points or calibration Calibrated at one temperature, but not at another Door not sealing 3/ Check connections to sensor. 4/ Check calibration using independent thermometer, follow instructions in section 5.6. 1/ Verify that controller is asking for heat by looking for HEATING light if pilot light is not on continuously during initial start up, there is a problem with the controller. 2/ Check amperage amperage should be virtually at maximum rated (data plate) amperage. 3/ Do all controller functions work? 4/ Is the Overtemperature set high enough? for diagnostics, should be fully clockwise with the pilot light never on. 5/ Has the fuse/circuit breaker blown? 1/ ±0.1 may be normal. 2/ Is fan working? remove top panel and verify movement of cooling fan. 3/ Is ambient radically changing either door opening or room airflow from heaters or air conditioning? stabilize ambient conditions. 4/ Sensor miss-located, damaged or wires may be damaged - check mounts for control and Overtemperature sensors, then trace wires or tubing between sensors and controls. 5/ Calibration sensitivity call Customer Service. 6/ Overtemperature set too low be sure that its setting is more than 5 degrees over desired set point; check if pilot light is on continuously; turn controller knob completely clockwise to see if problem solved then follow instructions in section 5.7 for correct setting. 7/ Electrical noise remove nearby sources of RFI including motors, arcing relays or radio transmitters. 8/ Bad connection on temperature sensor or faulty sensor check connectors for continuity and mechanical soundness while watching display for erratic behavior; check sensor and wiring for mechanical damage. 9/ Bad connections check connectors for mechanical soundness and look for corrosion around terminals or signs of arcing or other visible deterioration. 1/ Assure that set point is at least 5 degrees over ambient. 2/ See if ambient is fluctuating check for adjacent open doors or HVAC duct openings, stabilize ambient conditions. 1/ Calibration error see section 5.6. 2/ Temperature sensor failure evaluate if pilot light is operating correctly. 3/ Controller failure evaluate if pilot light is operating correctly. 4/ Allow at least 24 hours to stabilize at set point temperature. 5/ Verify that reference thermometer is certified. 1/ Turn entire unit off and on to reset. 2/ If repeatedly happens, call Customer Service. This can be a normal condition when operating temperature varies widely. For maximum accuracy, calibration should be done at or as close to the set point temperature as possible. MECHANICAL 1/ Check physical condition of gasket. 12

Motor doesn't move Motor makes noise Controller on at all times - "locked-up" Front panel displays are all off Unit or wall fuse/circuit breaker is blown Unit will not turn on Unit is smoking Out of box Contamination in chamber 2/ Assure that gasket is in original location. 3/ Adjust hinge blocks or twist the door. 4/ Confirm that unit has not been damaged and body is square. 1/ If shaft spins freely: check connections to motor and check voltage to motor. 2/ If shaft rubs or is frozen, relieve binding and retest. 1) Make sure that the fan or blower wheel is not contacting its housing. Adjust the motor mounting bracket position to re-center the fan or blower wheel, if necessary. 2) Check the fan or blower wheel for damage or out of balance condition. Replace the fan or blower wheel if it is damaged or out of balance. 3) Turn the motor shaft to make sure that it spins freely. If it binds or the bearings make a rubbing or scrapping sound then replace the motor. OTHER 1/ Turn unit off and on to reset. 2/ If cannot change any condition on the front panel, call Customer Service. Check for wire damage. 1/ Check wall power source. 2/ Compare current draw and compare to specs on data plate. 3/ See what other loads are on the wall circuit. 1/ Check wall power source. 2/ Check fuse/circuit breaker on unit or in wall. 3/ See if unit is on, e.g., fan or heater, and just controller is off. 4/ Check all wiring connections, especially around the on/off switch. This is not an uncommon occurrence when first operating new units. Put unit under vent and run at full power for one hour. smoking is normal during first cycle to temperature. 1/ See cleaning procedure in section 2.5. 2/ Develop and follow standard operating procedure for specific application; include definition of cleaning technique and maintenance schedule. If following these troubleshooting suggestions does not solve the problem call your customer service representative for assistance. Please see the manual cover for information on where to contact customer service. 13

PARTS LIST Section 9 Description 115V 220V Blower Motor 4880548 4880548 Blower Wheel 2600535 2600535 Cooling Fan, Control Panel 4880564 4880563 Cord Set 1800510 1800500 EMI Filter 2800503 2800503 Fuse 10 Amp N/A 3300516 Fuse 16 Amp 3300513 N/A Heating Element, RI28 2350563 2350554 Heating Element, RI40 2350557 2350566 Overtemperature Thermostat 1750982 1750983 I/O (On/Off) Power Switch 7850579 7850579 Moisture Proof Plug 1650530 1650530 Main Control w/sensing Probe 1750582 1750583 Outlet, Interior 1650531 1650531 Pilot Light, Green 4650554 4650554 Pilot Light, Red 4650553 4650553 Shelf, RI28 5400500 5400500 Shelf, RI40 5401146 5401146 14

UNIT SPECIFICATIONS Weight Shipping Net RI28 610 lbs. 500 lbs. RI40 730 lbs. 850 lbs. Dimensions Exterior WxDxH Interior WxDxH RI28 38.5x34.0x75.3 30.5x26x62 RI40 41x34x87 35x26x76.5 RI28 RI40 Capacity 28 Cubic Feet 40 Cubic Feet Temperature Range Uniformity Sensitivity RI28 Amb. +8 to 70 C +.5 C @ 37 +.05 C RI40 Amb. +8 to 70 C +.5 C @ 37 +.05 C 15

WIRE DIAGRAM RI28 120V (9851242) IEC FUSED INLET 4200505 2800503 MAIN POWER SWITCH CHERRY ROUND 7850532 POWER LIGHT ~ 4650554 (G) CHAMBER FAN ~ 4880548 RED BLU ½ TB1 L1 ½ TB1 L2 HOT NEUTRAL TEMPERATURE CONTROL 1750982 GROUND LOAD OTP LIGHT 4650553 (R) 4 1 2 HT HT 0900503 0.47 F / 250 VAC OTP 1750862 DESIGN = 750W / 120V / 19.2 HEAT LIGHT 4650554(G) CONVENIENCE OUTLETS 6100525 x4 CHART RECORDER CONNECTIONS 16

WIRE DIAGRAM RI28-2 230V (9851243) IEC FUSED INLET 4200505 2800503 MAIN POWER SWITCH CHERRY ROUND 7850532 POWER LIGHT ~ 4650554 (G) CHAMBER FAN ~ 4880548 RED ½ TB1 L1 BLU & ½ TB1 L2 HOT NEUTRAL GROUND TEMPERATURE CONTROL 1750983 LOAD 0900503 OTP LIGHT 6540553 (R) 4 1 2 0.47 F / 250 VAC 4 HT HT 2 1 ½ OTP 1750813 DESIGN = 750W 83 HEAT LIGHT 4650554 (G) ½ OTP 1750813 EURO OUTLETS 6100531 x4 CHART RECORDER CONNECTIONS 17

WIRE DIAGRAM RI40 120V (9851244) IEC FUSED INLET 4200505 2800503 MAIN POWER SWITCH CHERRY ROUND 7850532 POWER LIGHT ~ 4650554 (G) CHAMBER FAN ~ 4880548 RED BLU ½ TB1 L1 ½ TB1 L2 HOT NEUTRAL TEMPERATURE CONTROL 1750982 GROUND LOAD OTP LIGHT 4650553 (R) 4 1 2 HT HT 0900503 0.47 F / 250 VAC OTP 1750862 DESIGN = 1000W 12.4 HEAT LIGHT 4650554(G) CONVENIENCE OUTLETS 6100525 x4 CHART RECORDER CONNECTIONS 18

WIRE DIAGRAM RI40-2 230V (9851245) IEC FUSED INLET 4200505 2800503 MAIN POWER SWITCH CHERRY ROUND 7850532 POWER LIGHT ~ 4650554 (G) CHAMBER FAN ~ 4880548 RED ½ TB1 L1 BLU & ½ TB1 L2 HOT NEUTRAL GROUND TEMPERATURE CONTROL 1750983 LOAD 0900503 OTP LIGHT 6540553 (R) 4 1 2 0.47 F / 250 VAC 4 HT HT 2 1 ½ OTP 1750813 DESIGN = 1000W 58.7 HEAT LIGHT 4650554 (G) ½ OTP 1750813 EURO OUTLETS 6100532 x4 CHART RECORDER CONNECTIONS 19

SHELDON MANUFACTURING, INC. LIMITED WARRANTY Sheldon Manufacturing, Inc., ( Manufacturer ) warrants for the original user of this product in the U.S.A. only that this product (parts only if outside of the U.S.A.) will be free from defects in material and workmanship for a period of two years from the date of delivery of this product to the original user (the Warranty Period ). During the Warranty Period, Manufacturer, at its election and expense, will repair or replace the product or parts that are proven to Manufacturer s satisfaction to be defective, or, at Manufacturer s option, refund the price or credit (against the price of future purchases of the product) the price of any products that are proven to Manufacturer s satisfaction to be defective. This warranty does not include any labor charges if outside of the U.S.A. This warranty does not cover any damage due to accident, misuse, negligence, or abnormal use. Use of Manufacturer s product in a system that includes components not manufactured by Manufacturer is not covered by this warranty. This warranty is void in the event that repairs are made by anyone other than Manufacturer without prior authorization from Manufacturer. Any alteration or removal of the serial number on Manufacturer s products will void this warranty. Under no circumstances will Manufacturer be liable for indirect, incidental, consequential, or special damages. The terms of this warranty are governed by the laws of the state of Oregon without regards to the principles of conflicts of laws thereof. If any provision of this limited warranty is held to be unenforceable by any court of competent jurisdiction, the remainder of this limited warranty will remain in full force and effect. This warranty is in lieu of and excludes all other warranties or obligations, either express or implied. Manufacturer expressly disclaims all implied warranties, including without limitation, the warranties of merchantability and fitness for a particular purpose. For fast and efficient support, please have the following information available anytime you request service: Model Serial No. Part No. 20