Installation Instructions For

Similar documents
Installation Instructions For

Installation Instructions for. WaterMatic Fountains

Installation Instructions for. DairyFount Series Fountains

Installation Instructions for. WaterMaster Series Fountains

Installation Instructions for. WaterMaster Series Fountains

Instruction Manual for. WaterMatic

Installation Instructions for. OmniFount

Installation Instructions for. CattleMaster Series Fountains

Installation Instructions for. OmniFount

Installation Instructions for. OmniFount

READ CAREFULLY INSTALLATION INSTRUCTIONS AND SPECIFICATIONS FOR MODEL 3345-E

Energy-Free Waterers SF-2C, SF-4C, EF-2C, EF-4C

READ ALL DIRECTIONS CAREFULLY BEFORE BEGINNING INSTALLATION

OPERATIONS MANUAL & PARTS LIST. BX2 Fastracts Extractor. IPC Eagle 3650 Dodd Rd, Eagan MN


FiberPRO 2.5 H. Heated Spot Extractor. Operator and Parts Manual E

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Oahu Showerspa Model #1035 Owner's Manual

READ CAREFULLY INSTALLATION INSTRUCTIONS AND SPECIFICATIONS FOR MODEL 3465

Xaact Spot. Xaact Hot Spot

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Operator s Manual. Stripping Solution Applicator

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Liberty-Classic. Operator s Manual

Installation & Operation Manual

HOTSPOT. Two Gallon Pump Up Spotter OPERATING & MAINTENANCE

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

INSTALLATION MANUAL LITTLE BUTLER HOT WATER AND DRINKING WATER FILTRATION FAUCETS LB13250 LB13150 DW13050

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

SERIES WATERERS INSTALLATION INSTRUCTIONS

B.I.C.A Built-In Coffee Appliance

Installation IMPORTANT! Bradley Multi-Station Wall Sink

Parts and Service Manual BURNISHER MODEL: MR , MR , MR , MR

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION and OPERATION BALL WASHER MODEL NO: BW-022

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

600 Floor Stripper Applicator

Pump Out Vacuums Polyethylene & Steel

C-Box 100, H-Box 200 & H-Box 500

WATERER OPTIONS. WATER TROUGH Available in galvanized and stainless steel sizes HEATED LIVESTOCK WATERER POLY WATERER

18 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers the EC18DVS MaxxAir Portable Evaporative Cooler.

INSTALLATION and OPERATION BALL WASHER, HIGH CAPACITY MODEL NO: BW-022AN

OUTDOOR DRINKING FOUNTAINS OPERATIONS MANUAL

READ ALL DIRECTIONS CAREFULLY BEFORE BEGINNING INSTALLATION

Parts and Instruction Manual ET Extraction Tool

SSS Intrepid 16 FMS. Manual

A112408B/S-VR-UBL TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Technical Assistance Fax:

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use.

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

FLCH4R Garage and Utility Electric Heater

Industrial Vacuums, Inc

COBRA -H EXTRACTOR 120V

MC MC MC MC MC833130

MERIDIAN MODEL# 3793

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

475 PRO SERIES Reverse Osmosis System Installation & Operation Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.

User s Manual and Operating Instructions

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

ADVANTAGE-100H-SC EXTRACTOR

48 MaxxAir Portable Evaporative Cooler Owner s Manual


MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

READ CAREFULLY INSTALLATION INSTRUCTIONS AND SPECIFICATIONS FOR MODEL 3345

Installation Manual Universal Side-of-Pole Mount UNI-SP/01A

INSTRUCTIONS REPAIR PARTS LIST AND WARRANTY INFORMATION

Installation Instructions

WATERER OPTIONS. WATER TROUGH Available in stainless steel sizes HEATED LIVESTOCK WATERER POLY WATERER AQUA BOWL SSH20 SINGLE HEAD WATERER

Installation Manual Universal Side-of-Pole Mount UNI-SP/02A

Model: PS-2 ProSense II Item # OPERATION SERVICE PARTS CARE

HP310-C EXTRACTOR 120V

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

FiberPRO. 15 Series. High Pressure Carpet Extractors. Operator and Parts Manual E E E

HotLine Internal Sewer Pipe Heater Installation Manual

MRS-6 Maxi-Guard II. Model: C , 12, 13, 14 OPERATION SERVICE PARTS CARE. Revised 2/02

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

GULPER 16SV 16 GALLON WET/DRY VACUUM WITH FRONT MOUNT SQUEEGEE

ST. KITTS CEILING FAN

WAIMEA. Waimea Showerspa Model #1034 Owner's Manual

RIO. Rio ShowerSpa Model #1049B-BN Owner s Manual

6-Gallon Carpet Extractor Series

Fountain Classic. Installation and Owner s Manual. Page 16

MAXUM Gallon Box Extractor

SAVE THESE INSTRUCTIONS

HE220, HE260 Humidifier Installation Kit

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

HE360 Humidifier Installation Kit

Wet/Dry Vacuums Polyethylene, Polypropylene, & Steel

Installation Manual Universal Top-of-Pole Mount UNI-TP/08LL

BURWELL BIDET TOILET SEAT INSTALLATION

READ ALL DIRECTIONS CAREFULLY BEFORE BEGINNING INSTALLATION

COBRA -300H EXTRACTOR

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

INSTALLATION INSTRUCTIONS

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

Prime Tower. Inline Chiller. Instructions for Models #2645,2646

Transcription:

Installation Instructions For AUTOFOUNT Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly installed and maintained. Please follow instructions carefully. Read and understand all instructions before installing Part # 24075 13 Aug, 2014

Fountain Installation Instructions A. Location - Installing the fountain in a location that offers protection from the wind will enhance the performance of the unit. Livestock will tend to gather in a protected area, enticing them to drink more. If possible, the side with the access panel should be opposite of prevailing winds for additional protection to the supply line. B. Mounting Platform A concrete platform (see above) should be provided for all fountains. It should be at least 4 thick and large enough to accommodate the fountain. An additional 4 high step 18 out from each side of the unit will protect the unit from manure handling equipment, as well as discouraging animals from defecating in the fountain. Extending the platform provides animals a place to stand while drinking, consider the size of your animals when determining the dimensions of your platform. Slope the platform away from the fountain for drainage. A rough broom finish on the concrete surface provides better footing for animals. C. Water Supply Line The horizontal underground water line (#1) should be sized to account for pressure drop, relating to distance, at least 3/4 diameter and 1 below normal frost depth. A 3/4 vertical supply pipe (#2) is recommended. A shut-off valve (#3) may be installed under the fountain for servicing. For optimum serviceability a stop and waste valve can be installed below frost level to drain water back when the unit is not in use. This can be obtained from your local plumber. Flush water supply line before connecting to fountain. Water supplies with material such as sand, rust, etc. may require a filter to keep valve working properly. D. Riser Tube Install a riser tube (#4) to provide room for plumbing Ritchie Thermal Tubes and to accommodate optional shut-off valve. Ensure that the water supply 18158 1 top section line is centered in the riser tube. For optimum water line protection, use 16417 2 top section the recommended insulated Ritchie Thermal Tube. Use a combination of 16612 4 top section Thermal Tubes to reach at the required depth of 1 below your frost depth. 16416 2 extension NOTE: The supply line touching the riser tube is the most common cause of the supply line freezing. Do not surround the supply line with insulation, wood, or other foreign material. Any foreign material in the tube may cause frost to migrate to the supply line causing it to freeze. AUTO-Fount Instruction Manual 1 08/13/2014

E. Preparing the Bottom - Apply the provided foam weather stripping to the bottom of the fountain, following along the outside edge of the fountain. Note: Sealing the bottom of the unit from cold air is an important aspect of the unit's thermal performance. F. Hold-Downs - Your fountain has either three or four built-in hold-down locations to anchor your unit securely to the concrete pad. The use of 3/8 x 5 stainless steel expansion anchor bolts (not included) is recommended for concrete installations. Anchor bolts are available from Ritchie in a two pack, part # 16555. Fender washers are supplied for use with anchors. G. Hose Connection Connect hose to customer supplied shutoff valve at the top of the concrete. Cut hose to proper length and slip onto the barb fitting of the valve assembly. Clamps and fittings are furnished to secure the connection. H. Drain Plug Install pre-assembled drain plugs from inside of trough. Plugs should be pushed in flush to prevent accidental removal by animals. Wetting the plug can aid proper installation. I. Float Adjustment Adjust float for a water depth of 2 inches below top of trough using the thumbscrew or wing nut. J. Electrical Connection In many areas, supplemental heat is required, it is easiest to run the electrical line at the same time you lay the waterline for your fountain. Any electrical service must be installed and maintained by a qualified electrician. K. Supplemental Heat - Incoming water Immersion Heaters Self-Regulating Heat Cable temperature and pressure will vary, and will affect Part # Volts Watts Part # Volts Watts the performance of your fountain. Well water will 16311 120 250 16276 120 30 be between 45 o and 50 o, but rural water from a 17960 240 250 16713 240 30 water tower may be substantially cooler. Supplemental heaters and alternate valves are available for these variations. Both the valve chamber and the water supply line should be protected from freezing. To protect the valve chamber, immersion heaters should be placed flat on the bottom of the chamber. Ensure the heater and power cable does not interfere with the motion of the float. Self-regulating heat cables protect the supply line from freezing. Heat cables should wrap around the valve, and follow the supply line down into the riser tube. You may use nylon ties to anchor the cable to the supply line. Both immersion heaters and supply line heaters are thermostatically controlled, using power only when needed. Neither heater will get hot enough to melt the plastic of the fountain. L. High Water Pressure - If water pressure is very high, and the valve does not shut off, a pressure-reducing valve may be needed. Your individual situations may require a change from the standard valve supplied with your fountain. M. Cleaning Your Fountain To clean your watering fountain you will need a good stiff brush. Open the cover and brush the tank to remove any build-up. Remove the drain plug(s) to drain dirty water and debris out. After trough has been cleaned and drained reinstall the plug(s) and let the tank refill. Now is a good time readjust the float if needed. Close cover and you are done. AUTO-Fount Instruction Manual 2 08/13/2014

Trouble Shooting Problem Valve won't stop dripping Low Water Flow Solution a) Check float adjustment. Ensure float moves freely. b) Disassemble valve and check for sand or scale in valve rubber c) Turn valve rubber over and re-assemble. See below. d) Check for excessive water system pressure. a) Check that valve inlet is not plugged or supply hose is not kinked. b) Check system pressure from supply hose by installing a tee and pressure gauge in front of the valve to check pressure drop when valve is open. A severe pressure drop indicates a restriction or undersized supply system. c) Check that shut off valves are fully open. 1/2 Valve: Ritchie Limited Warranty Effective September 2012 Ritchie Industries, Inc. warrants its products to be free of defective materials and workmanship. Defective part(s) will be repaired or replaced at the option of Ritchie Industries. This warranty specifically excludes all labor and shipping charges. This warranty does not apply to any appearance items, to any product whose exterior has been damaged or defaced, to any product that has been installed improperly, to any product subjected to misuse, abnormal service or handling, and to any products altered or repaired with other than original equipment or manufacturer s parts. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. All warranty claims must be processed through an Authorized Ritchie Dealer/ Distributor. Proof of purchase is required. This warranty is not transferable. The period of warranty begins at original date of purchase as follows: Poly Units Base, top and ball closures 10 year limited against manufacturing defect. 100% first five years, then declining 20% per year for the remaining five years. Stainless Steel Units Stainless trough and stainless valve chamber frame: Ten years against manufacturing defect or corrosion. 100% all ten years. Casing and cover: 10 year limited against manufacturing defect. 100% first year, then declining 10% per year for the remaining nine years. Component Parts All component parts, such as floats, valves, heating elements: One year from the date of purchase against manufacturing defect, 100%. Hydrants All component parts: One year from the date of purchase against manufacturing defect, 100%. AUTO-Fount Instruction Manual 3 08/13/2014

Classic Equine AUTOFOUNT Part # 18720 10 5 1 4 8 2 3 9 11 7 6 IMMERSION HEATER 16311-120V 250W SELF-LIMITING HEAT CABLE 16276-120V 30W Item Part # Description Qty Item Part # Description Qty 1 18712 AUTOFOUNT Cover 1 9 12836 Float with Long Arm pkg 1 pkg 2 18714 AUTOFOUNT Base 1 10 18752 Bulkhead pkg 1 pkg 3 18470 Drain Plug Ritchie 3" 1 pkg 11 18719 Classic Equine Logo pkg (2/pkg) 1 pkg 4 18716 Classic Equine Hinge Bolt Pkg 1 pkg NS 15930 Hose Clamp 7/8" SS (5/pkg) 1 pkg 5 18718 Cover Latch Hardware pkg 1 pkg NS 18613 Adapter 1/2" x 3/8" HB 1 pkg 6 18753 Access Panel Hardware Pkg 1 pkg NS 18739 AUTOFOUNT Accessory pkg 1 pkg 7 18726 Classic Equine Access Panel 1 NS 14866 Seal Foam 10' Roll 1 8 12575 Red Valve 1/2" pkg 1 pkg AUTO-Fount Instruction Manual 4 08/13/2014

4 Classic Equine AUTOFOUNT 1 Part # 18770 1 10 3 5 8 2 11 9 7 6 IMMERSION HEATER 16311 120V 250W SELF LIMITING HEAT CABLE 16276 120V 30W Item Part # Description Qty Item Part # Description Qty 1 18766 AUTOFOUNT 1 Cover 1 9 12836 Float with Long Arm pkg 1 pkg 2 18768 AUTOFOUNT 1 Base 1 10 11515 Valve Bracket 1/2" w/ Screws pkg 1 pkg 3 18470 Drain Plug Ritchie 3" 1 pkg 11 18719 Classic Equine Logo pkg (2/pkg) 1 pkg 4 18716 Classic Equine Hinge Bolt Pkg 1 pkg NS 15930 Hose Clamp 7/8" SS (5/pkg) 1 pkg 5 18718 Cover Latch Hardware pkg 1 pkg NS 18613 Adapter 1/2" x 3/8" HB 1 pkg 6 18753 Access Panel Hardware Pkg 1 pkg NS 18771 AUTOFOUNT Accessory pkg 1 pkg 7 18726 Classic Equine Access Panel 1 NS 14866 Seal Foam 10' Roll 1 8 12575 Red Valve 1/2" pkg 1 pkg AUTO-Fount Instruction Manual 5 08/13/2014