The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Similar documents
Wireless Fire & Security Solutions. Fire Product Showcase

Wireless Fire & Security Solutions. Fire Product Showcase

ZITON RADIO LOOP MODULE

Maintenance Guide EMS Security Group Ltd. All rights reserved. MK154 Iss5 18/11/15 AJM

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Consultant Specification AGILE Wireless Fire Detection System

Solution F2. Fire Alarm Control Panels one step ahead.

Intelligent addressable fire alarm control panel

5000 INSTALLATION GUIDE

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Product Guide MAN7030-2

The EN54 Part 2 & 4 Fire System

>WIRELESS> ALARM SYSTEM CR200

System 800 Addressable Fire Detection & Alarm System

The EN54 Part 2, 4 and 13 Fire System

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

The Kentec driver connects to the Kentec Syncro range of fire detection panels. Available for Commander and ObSys.

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

Sita200plus. 200detectors. Single loop analogue addressable System

Addressable and Conventional Fire Protection

Touch Screen 1 loop Addressable Fire Alarm Panel

ACP10 & ACP50 Security Systems

Intelligent 2 & 4 Loop Fire Alarm Control Panels

ID50series. intelligent fire alarm panels

SMS GSM Alarm Messenger

Excel-EN Conventional Fire Control Panel

DS7400Xi Addressable Control/ Communicator

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

IGD.CO.UK

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

ZXSe Range Data Sheet

An introduction to... Sigma

SYSTEM 5000 USER MANUAL

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Fire control panels FC726 FC726-XA

OPERATION AND INSTALLATION MANUAL

Advanced FireAlarm Panel 1-4Loop

APPLICATION DATA SHEET

EFBW series - BiWire Ultra control panel

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

Intelligent Single Loop Fire Alarm Control Panel

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Fire Detection - Addressable

TrueAlarm Fire Alarm Controls

Xenex Conventional Fire Detection & Alarm System

FIRElux Emergency Lighting

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

Reliably Advanced Extinguishing Control

Installation, Operating and Maintenance Manual

Intelligent Addressable Fire Alarm System

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Industrial Grade Gas Detection Detecting The Difference

FIRE DETECTION SYSTEMS. Product Guide

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Syncro AS. Analogue Addressable Fire Control Panel. Product Manual

Industrial Grade Gas Detection

Product Data Sheet. Remote Terminals. Features:

Conventional Fire Detection

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Fire Alarm System. The Intelligent Solution. Leading global technology Safe guarding lives and properties

IQ8Control C Fire Alarm Panel

Added password for IP setup page : Password must be in IP format!

APPLICATION DATA SHEET

For Complete Fire and Gas Solutions

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Fire detection and alarm

Security Alarm Systems

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

July 14, 1999 DF C-100.

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

IC60 Sintony 60 Intrusion Control Panel

Solution F1. Fire Control Panels the new generation

SUPREMATouch. Modular Fire & Gas Detection System

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Radio fire warning panel SRC 3000

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

XP95/Series 90 Test Set

Reliably Advanced Extinguishing Control

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

MINERVA MX. 800 Series Ancillary Equipment

Integrated Security Solutions

intelligent fire alarm ID60series panels

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

CODESEC FIRE ALARM SYSTEMS. security technologies

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

SOLO Single Loop Addressable Fire Control Panel

Industrial Grade Gas Detection

Touchpoint Plus. A whole new control experience

Transcription:

FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001 Radio Hub is designed as the loop interface node for up to 64 RCC s. These then give information via the loop to any CIE using the XP95 protocol. The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. The cluster network is designed to send and receive information via multiple hops to ensure that a single point of failure does not lose more than 32 devices. Designed and manufactured using the latest techniques and surface-mount technology ensures component count is kept to a minimum, thereby maximising reliability. One, two and four loop versions of the Radio Hub are available.

Specification Dimensions: Operating Temperature: Humidity: Supply: IP Rating: Operating Frequencies: Output Transmitter Power: Standards: 270 x 205 x 75mm. Weight 0.95Kg -10 to 70 C Up to 95% non-condensing Loop powered 24v with a maximum current draw of 50mA IP54 868 MHz 14dBm Third party approved to; EN54 part 18 EN54 part 25 ENTSI 300:220 Ordering Information 1 loop radio hub: 2 loop radio hub: 4 loop radio hub: Part Number FCX- 500-001 Part Number FCX- 500-002 Part Number FCX- 500-004 An ISO9001:2008 approved company Dealer Information: EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: enquiries@emsgroup.co.uk www.emsgroup.co.uk Part No: Firecell 1, v1.5 The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written.

FireCell Optical Smoke Detector Wireless activation Third party approved (EN54) 2-way radio communication Protected sensing chamber 5 year battery life at normal conditions Universal transmitter module Detector / transmitter tamper Range in excess of 150 metres Overview The model FCX-100-001 Optical Smoke Detector is bayonet fitted to a radio address/transmitter module, incorporating alkaline batteries and supplied with a surface-mount base unit. Removal of the detector or address/transmitter module will indicate a fault condition. The detector is manufactured by Apollo and complies with EN54 Part 7 and EN54 part 25. The detector incorporates a selectable automatic lock, which, if enabled locks it into its base when plugged in, preventing unauthorised removal. Each unit has a unique address configured during manufacture and is individually addressable by the system controller. The radio address module is programmed to report at regular intervals of less than 300 seconds. Designed and manufactured using the latest techniques and surface-mount technology ensures component count is kept to a minimum, thereby maximising reliability. The address/transmitter module is powered by a low-voltage dual supply alkaline battery pack. The battery pack condition is continually monitored. The battery pack has been tested to provide a 5 year life at normal conditions (15-35 C). The system indicates remaining battery capacity and a low battery condition is indicated to the controller as a fault, allowing 30 days for the battery pack to be changed before unit failure.

Specification Dimensions: Operating Temperature: Humidity: Supply: IP Rating: 106x75 mm with transmitter/address module Weight.0.35Kg -10 to 70 C Up to 95% non-condensing 6 x AA cell Duracell Alkaline batteries IP23 Operating Frequencies: Output Transmitter Power: Standards: 868 MHz Variable 0-14dBm Third party certified to; EN54 part 7 EN54 part 25 ENTSI 300:220 Ordering Information Detector/address module complete Head only Detector base Part Number FCX-100-001 Part Number FCX-177-001 Part Number FCX-170-001 An ISO9001:2008 approved company Dealer Information: EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: enquiries@emsgroup.co.uk www.emsgroup.co.uk Part No: Firecell 2, v1.4 The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written.

FireCell Radio Cluster Communicator (RCC) Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication 72 hours battery backup Diagnostics port Overview The model FC-555-001 RCC is designed as the remote transceiver node for up to 32 detection devices or sounders. These then gives information back to the master node to be indicated via the loop to the CIE. The RCC can talk directly to the Radio Hub, or via another RCC (up to 4 hops). This enables easy expansion of the system where direct signal paths are not possible. Designed and manufactured using the latest techniques and surface-mount technology ensures component count is kept to a minimum, thereby maximising reliability.

Specification Dimensions: Operating Temperature: Humidity: Supply: 270 x 205 x 75mm Weight 1.80Kg -10 to 70 C Up to 95% non-condensing Mains powered 230Vac Battery backup 72 hours 6V 4Ahr IP Rating Operating Frequencies: Output Transmitter Power: IP rating Standards: IP54 868 MHz 14dBm IP54 Third party approved to; EN54 part 4 EN54 part 18 EN54 part 25 ENTSI 300:220 Ordering Information FireCell Radio Cluster Communicator includes PSU & Standby battery: Part Number FC-555-001 FireCell Radio Cluster Communicator with remote aerial facility includes PSU, Standby battery & 3 x FC-868-D00 aerials: Part Number FC-555-331 An ISO9001:2008 approved company Dealer Information: EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: enquiries@emsgroup.co.uk www.emsgroup.co.uk Part No: Firecell 3, v1.5 The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written.

FireCell Heat Detector Wireless activation 2-way radio communication Protected sensing chamber 5 year battery life at normal conditions Universal transmitter module Detector/transmitter tamper Range in excess of 150 metres Overview The model FCX-120-001 radio heat detector is bayonet fitted to a radio address/transmitter module, incorporating alkaline batteries and supplied with a surface-mount base unit. Removal of the detector or address/transmitter module will indicate a fault condition. The detector is manufactured by Apollo and complies with EN54 Part 5 and EN54 Part 25. The heat detector operates on a highly sensitive thermistor, which measures actual temperature and the rate of temperature rise change. At regular intervals, the detector carries out a self test that checks and verifies every function, including the thermistor and sensitivity to temperature. Any failure is automatically reported to the control panel. The detector incorporates a selectable automatic lock, which, if enabled locks it into its base when plugged in, preventing unauthorised removal. Each unit has a unique address configured during manufacture and is individually addressable by the system controller. The radio address module is programmed to report at regular intervals-every 300 seconds. Designed and manufactured using the latest techniques and surface-mount technology ensures component count is kept to a minimum, thereby maximising reliability. The address/transmitter module is powered by a low-voltage dual supply alkaline battery pack. The battery pack condition is continually monitored. The battery pack has been tested to provide a 5 year battery life at normal conditions (15-35 C). The system indicates remaining battery capacity and a low battery condition is indicated to the controller as a fault, leaving approximately 30 days for the battery pack to be changed.

Specification Dimensions: 106 x 75 mm with transmitter/address module Weight 0.35Kg Operating Temperature: Humidity: Supply: IP Rating: Operating Frequencies: Output Transmitter Power: Standards: -10 to 70 C Up to 95% non-condensing 6 x AA cell Duracell Alkaline batteries IP23 868 MHz Variable 0-14dBm EN54 part 5 EN54 part 25 ENTSI 300:220 Ordering Information Detector/address module complete Heat Head only (Class CS) Heat Head only (Class A1R) Detector base Part Number FCX-120-001 Part Number FCX-176-001 Part Number FCX-175-001 Part Number FCX-170-001 An ISO9001:2008 approved company Dealer Information: EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: enquiries@emsgroup.co.uk www.emsgroup.co.uk Part No: Firecell 4, v1.4 The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written.

FireCell Callpoint Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication 5 year battery life at normal conditions Universal transmitter module Transmitter tamper Range in excess of 150 metres Overview The model FC-200-002 Radio Callpoint is battery operated incorporated in a radio address module, thereby eliminating the need for wiring back to the fire alarm control panel. The callpoint is designed to meet EN54 part 11 and is designed to comply with EN 54 part 25. The callpoint is fitted into an industry standard ABS moulding which allows for testing by insertion of a test key. When the glass is broken the micro-switch is released, triggering an alarm transmission by radio, to the alarm panel. Designed and manufactured using the latest techniques and surface-mount technology ensures component count is kept to a minimum, thereby maximising reliability. The Callpoint is powered by a low-voltage dual supply alkaline battery pack. The battery pack condition is continually monitored. The battery board has been tested to provide a five year battery life at normal conditions. The system indicates remaining battery capacity and a low battery condition is indicated to the controller as a fault, allowing 30 days for the battery pack to be replaced before unit failure.

Specification Dimensions: Operating Temperature: Humidity: Supply: IP Rating: Operating Frequencies: Output Transmitter Power: Standards: 87 x 87 x 67 mm with transmitter/address module Weight 0.40Kg -10 to 70 C Up to 95% non-condensing 6 x AA cell Duracell Alkaline batteries IP24 868 MHz Variable 0-14dBm Third party certified to; EN54 part 11 EN54 part 25 ENTSI 300:220 Ordering Information Red Radio Callpoint Part Number FC-200-002 An ISO9001:2008 approved company Dealer Information: EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: enquiries@emsgroup.co.uk www.emsgroup.co.uk Part No: Firecell 5, v1.4 The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written.

FireCell Sounder Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication 5 year battery life at normal conditions 32 selectable tones Beacon option Acoustic self test Universal transmitter module Transmitter tamper Range in excess of 150 metres Overview The model FCX-300-002 Radio Sounder is a battery operated sounder remotely activated and monitored by the controller. Each unit has a unique address configured during manufacture and is individually addressable by the system controller. Each unit is controlled individually or by zone, dependant on the system design. The radio sounder is housed in an industry standard, impact resistant ABS moulding. The sounder has 2-way radio communication with the fire system controller using 868MHz wavebands to receive command instructions for auto reporting. Designed and manufactured using the latest techniques and surface-mount technology ensures component count is kept to a minimum, thereby maximising reliability. The sounder is powered by a low-voltage dual supply alkaline battery pack. The battery pack condition is continually monitored. The battery board has been tested to provide a 5 year battery life at normal conditions. The system indicates remaining battery capacity and a low battery condition is indicated to the controller as a fault, leaving approximately 30 days for the battery pack to be changed.

Specification Dimensions: Operating Temperature: Humidity: Supply: IP Rating Sounder Output 120 x 125 mm with transmitter/address module Weight 0.65Kg -10 to 70 C Up to 95% non-condensing 3 x AA & 3 x C cell Duracell Alkaline batteries IP54 99 dba @1m (as dispatched) Operating Frequencies: Output Transmitter Power: Standards: 868 MHz Variable 0-14dBm Third party certified to; EN54 part 3 EN54 part 25 ENTSI 300:220 Ordering Information radio sounder includes base and batteries: radio sounder radio base only: red sounder head: red sounder beacon Part Number FC-300-002 Part Number FC-171-002 Part Number FC-172-002 Part Number FC-173-002 An ISO9001:2008 approved company Dealer Information: EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: enquiries@emsgroup.co.uk www.emsgroup.co.uk Part No: Firecell 6, v1.5 The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written.

FireCell Input / Output Unit Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication IP65 casing 5 year battery life at normal conditions Dual input option Dual output option Universal transmitter module Transmitter tamper Range in excess of 150 metres Overview The model FC-600-001 Input/Output unit is a battery operated device remotely activated and monitored by the node network. Model FC-610-001 has dual inputs and outputs that can be individually operated whilst using only one address on the system. The device is housed in an industry standard, impact resistant ABS moulding and has 2-way radio communication with the fire system controller using 868MHz wavebands to receive command instructions for auto reporting. Designed and manufactured using the latest techniques and surface-mount technology ensures component count is kept to a minimum, thereby maximising reliability. The I/O unit is powered by a low-voltage dual supply alkaline battery pack. The battery pack condition is continually monitored. The battery board has been tested to provide a 5 year battery life at normal conditions. The system indicates remaining battery capacity and a low battery condition is indicated to the controller as a fault, leaving approximately 30 days for the battery pack to be changed.

Specification Dimensions: Operating Temperature: Humidity: Supply: IP Rating: Output Rating: Operating Frequencies: Output Transmitter Power: Standards: 240 x 120 x 50mm Weight 0.60Kg -10 to +55 C Up to 95% non-condensing 6 x AA cell Duracell Alkaline batteries IP65 2A @24V DC. 868 MHz Variable 0-14dBm Third party certified to; EN54 part 18 EN54 part 25 ENTSI 300:220 Ordering Information Single I/O Unit Dual I/O Unit Aux. relay module 2 x 230V 2amp relays Part Number FC-600-001 Part Number FC-610-001 Part Number FC-620-001 An ISO9001:2008 approved company Dealer Information: EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: enquiries@emsgroup.co.uk www.emsgroup.co.uk Part No: Firecell 7, v1.4 The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written.

FireCell Control Panels 16 zonal LED indicators 2 programmable sounder circuits 5 programmable inputs 3 programmable relays 3A power supply Powerful and versatile cause & effect programming Fully EN54-2 and EN54-4 compliant Compact, stylish enclosure Stores 1000 last events in event log Overview FireCell Syncro and Syncro AS are a versatile range of open protocol fire alarm control panels, compatible with existing Syncro fire alarm panel technology. Available with one, two or four detection loops capable of hosting up to 126 radio devices per loop. FireCell Syncro and Syncro AS use leading edge microprocessor based electronics to provide a flexible control system with high reliability and integrity. FireCell Syncro and Syncro AS control panels can be expanded and networked to become part of much larger systems if the need arises, therefore providing a future proof solution for any installation. With its large graphical display and ergonomic button and indicator layout, the FireCell Syncro and Syncro AS control panels are simple and straight forward to understand for installers, commissioning engineers and end users alike. The control panel is available as a flush mountable version and also has the option for a thermal printer. The enclosure is available in different sizes dependant on loop and option capability but typical dimensions are for one and two loop versions 385 x 310 x 90mm (Surface), 415 x 315 x86mm (Flush), typical four loop panels are 500 x 355 x 117mm (Surface) and 506 x 360 x 130mm (Flush).

Specification Construction: Enclosure finish: Mains voltage supply: Mains supply fuse: Power supply DC rating: Aux 24V supply: Battery (24 hour standby): Fault contact rating: Fire contact rating: Alarm contact rating: Sounder output rating: Detection loop: Detector protocols: Printer port: Serial expansion port: PC port: Network connection: Remote Silence input (SIL): Remote fault input (FLT): Remote reset input (RES): Remote alert input (INT): Remote evacuate input (CNT): Download lead: Configuration: PC graphics: Modem: 1.2mm sheet steel RAL9002 110 or 230V AC 50 or 60 Hz (specify when ordering, default is 230V) 1.6A 250V 24V 3 Amps Fused at 500 milliamps 9Ah 12V (2 per panel) (non-networked) 30V DC 1 Amp 30V DC 1 Amp 30V DC 1 Amp Fused at 1 Amp each 400 milliamp output XP95 Serial RS232 Serial RS485 (Compatible with all Syncro I/O modules) Serial RS232 RS485 - Up to 64 panels via fully fault tolerant optional network card Switched -ve Switched -ve Switched -ve Switched -ve Switched -ve Standard FC-000-Ken Programming Lead Via FireCell CIE Programming Software Via Guide or Guide Net systems Optional dial up modem for remote diagnostics (Can be fitted to M3 size enclosure only) Ordering Information For ordering information please contact EMS with your requirements. An ISO9001:2008 approved company Dealer Information: EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: enquiries@emsgroup.co.uk www.emsgroup.co.uk Part No: Firecell 9, v1.5 The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written.

Combined Detector Sounder Fully Addressable Wire-free activation Third party approved (EN54) 2-way radio communication Upto 5 Year battery life Beacon option Acoustic Self Test Universal transmitter module Transmitter tamper Range in excess of 150 metres Overview The model FCX-191-101 combined radio detector sounder is a battery operated device that is remotely activated and monitored by the controller. Each unit has a unique address configured during manufacture and is individually addressable by the system controller. Each unit is controlled individually or by zone, dependant on the system design. The device is housed in an, impact-resistant ABS moulding. The sounder has 2- way radio communication with the fire system controller using 868MHz wavebands to receive command instructions for auto reporting. The device has a removable head allowing for options for Optical. Heat and multi-sensors. Designed and manufactured using the latest techniques and surface mount technology ensures component count is kept to a minimum, thereby maximising reliability. The Detector sounder is powered by a low-voltage dual supply Alkaline battery pack. The battery pack condition is continually monitored. The battery board has been tested to provide up to 5 years of normal site operations. The system indicates remaining battery capacity and a low battery condition is indicated to the controller as a fault leaving approximately 30 days for the battery pack to be changed.

Specification Dimensions: 146 x 94mm with multi-sensor fitted 146 x 86mm with heat sensor fitted 146 x 84mm with optical sensor fitted Weight. Operating Temperature: Humidity: Supply: Operating Frequencies: Output Transmitter Power: Standards: Ordering Information FCX-191-001 FCX-190-001 FCX-192-011 FCX-192-001 FCX-191-201 FCX-190-201 FCX-192-211 FCX-192-201 0.70kg -10 to 70 degrees C Up to 95% non-condensing Up to 5 year integral energy source 868 MHz Variable 0-14dBm Third party certified to; EN54 part 3 EN54 part 7 EN54 part 5 ENTSI 300:220 FireCell Combined Sounder and Optical Smoke Detector. FireCell Combined Sounder and Multisensor Detector. FireCell Combined Sounder and Heat Detector (Class CS). FireCell Combined Sounder and Heat Detector (Class A1R). FireCell Combined Sounder -Beacon (Red) and Optical Smoke Detector. FireCell Combined Sounder -Beacon (Red) and Multisensor Detector. FireCell Combined Sounder -Beacon (Red) and Heat Detector (Class CS). FireCell Combined Sounder -Beacon (Red) and Heat Detector (Class A1R). Note: Other options are available in our full price List. An ISO9001:2008 approved company Dealer Information: EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: enquiries@emsgroup.co.uk www.emsgroup.co.uk Part No: Firecell 10, v1.3 The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written.

FireCell Voice Sounder Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication 5 year battery life at normal conditions Extensive Message Library Beacon option Acoustic self test Synchronised operation Transmitter tamper Range in excess of 150 metres Overview The model FireCell Wireless Voice Sounders are battery operated sounder devices remotely activated and monitored by the controller. Each unit has a unique address configured during manufacture and is individually addressable by the system controller. Each unit is controlled individually or by zone, dependant on the system design. The Voice sounders are available with pre-programmed messages selected from an extensive message library covering almost any conceivable application. All voice messages are clear and fully synchronised to help reduce confusion and distress during an active alarm. The voice sounders are housed in an industry standard, impact resistant ABS moulding. The sounder has 2-way radio communication with the fire system controller using 868MHz wavebands to receive command instructions for auto reporting. Designed and manufactured using the latest techniques and surface-mount technology ensures component count is kept to a minimum, thereby maximising reliability. The units are powered by a low-voltage dual supply alkaline battery pack. The battery pack condition is continually monitored. The battery board has been tested to provide a 5 year battery life at normal conditions. The system indicates remaining battery capacity and a low battery condition is indicated to the controller as a fault, leaving approximately 30 days for the battery pack to be changed.

Specification Dimensions: Operating Temperature: Humidity: Supply: IP Rating 120 x 125 mm with transmitter/address module Weight 0.65Kg -10 to 70 C Up to 95% non-condensing 3 x AA & 3 x C cell Duracell Alkaline batteries IP54 Operating Frequencies: Output Transmitter Power: Standards: 868 MHz Variable 0-14dBm Third party certified to; EN54 part 25 ENTSI 300:220 Ordering Information Wireless white voice sounder includes white radio base and batteries: Wireless red voice sounder includes red radio base and batteries: Wireless clear voice sounder beacon includes white radio base and batteries: Wireless clear voice sounder beacon includes red radio base and batteries: Wireless red voice sounder beacon includes white radio base and batteries: Wireless red voice sounder beacon includes red radio base and batteries: Part Number FC-345-001 Part Number FC-354-002 Part Number FC-386-011 Part Number FC-386-012 Part Number FC-386-021 Part Number FC-386-022 An ISO9001:2008 approved company Dealer Information: EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: enquiries@emsgroup.co.uk www.emsgroup.co.uk Part No: Firecell 11, v1.1 The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written.

Radio Network Communicator 24V Powered Range in excess of 500 metres Low current consumption Fully monitored 8 Networkable communicators per system Bi-direction Communication 32 selectable Channels Minimal programming required Range extension capability LED indication of communication LCD programming display Overview The model FCX-430-001 Radio Network Communicator is a 24V powered module that allows FireCell Control panels to have Wireless network capability The communicator is housed in a metal enclosure using 458MHz wavebands to receive command instructions for auto reporting. The radio network is configured in a mesh network topology. In a mesh network all nodes in the system are responsible for analysing and processing all radio data traffic allowing for any system network configuration. Mesh networks require no pre-configured structure or hierarchy in order for them to operate successfully. Mesh networks require simply that every communicator be in range of at least one other communicator in the network. This allows greater flexibility in the size and shape of mesh networks and proximity of communicators to one another within their maximum achievable range. Designed and manufactured using the latest techniques and surface-mount technology ensures component count is kept to a minimum, thereby maximising reliability.

Specification Dimensions: 156mm x 228mm x 48mm Weight 0.65Kg Operating Temperature: Humidity: Supply: IP Rating -10 to 70 C Up to 95% non-condensing 24Vdc 75mA IP54 Operating Frequencies: 458 MHz Output Transmitter Power: Standards: 500mW Third party certified to; ENTSI 300:220 Ordering Information Radio Network Communicator Part Number FCX-430-001 An ISO9001:2008 approved company Dealer Information: EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: enquiries@emsgroup.co.uk www.emsgroup.co.uk Part No: Firecell 12, v1.1 The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written.

FireCell Multisensor Detector Wireless activation Third party approved (EN54) 2-way radio communication Protected sensing chamber 5 year battery life at normal conditions Universal transmitter module Detector / transmitter tamper Range in excess of 150 metres Overview The model FCX-130-001 is a thermically enhanced optical Detector and is bayonet fitted to a radio address/transmitter module, incorporating alkaline batteries and supplied with a surface-mount base unit. Removal of the detector or address/transmitter module will indicate a fault condition. The detector is manufactured by Apollo and complies with EN54 Part 7 and EN54 part 25. The detector incorporates a selectable automatic lock, which, if enabled locks it into its base when plugged in, preventing unauthorised removal. Each unit has a unique address configured during manufacture and is individually addressable by the system controller. The radio address module is programmed to report at regular intervals of less than 300 seconds. Designed and manufactured using the latest techniques and surface-mount technology ensures component count is kept to a minimum, thereby maximising reliability. The address/transmitter module is powered by a low-voltage dual supply alkaline battery pack. The battery pack condition is continually monitored. The battery pack has been tested to provide a 5 year life at normal conditions (15-35 C). The system indicates remaining battery capacity and a low battery condition is indicated to the controller as a fault, allowing 30 days for the battery pack to be changed before unit failure.

Specification Dimensions: Operating Temperature: Humidity: Supply: IP Rating: 106x75 mm with transmitter/address module Weight.0.35Kg -10 to 70 C Up to 95% non-condensing 6 x AA cell Duracell Alkaline batteries IP23 Operating Frequencies: Output Transmitter Power: Standards: 868 MHz Variable 0-14dBm Third party certified to; EN54 part 7 EN54 part 25 ENTSI 300:220 Ordering Information Detector/address module complete Head only Detector base Part Number FCX-130-001 Part Number FCX-174-001 Part Number FCX-170-001 An ISO9001:2008 approved company Dealer Information: EMS Group Head Office Technology House Sea Street Herne Bay Kent CT6 8JZ England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: enquiries@emsgroup.co.uk www.emsgroup.co.uk Part No: Firecell 13, v1.0 The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written.